HomeMy WebLinkAboutCYLINDER DIAGRAMr
RECEIVED
SEP 2 0 -m
ST. Lucie County, Permitting
100gal LP gas tank
ASME
tanks manifolded together
100gal LP gas tank
11 ASME
twin stage reg
11" we
generator permitted
and installed by others
350000 btu
15' of 3/4" galy pipe y
attached to wall �O ti rn III
oZAE
r"Z3—
�o o'TTr4
COm �mfi
0 oc
y CO
rn v
t r�
zv
m? m&
tCMD
p
CD W
DIVERSIFIED SERVICES
DIVERSIFIED LEADER IN THE GAS INDUSTRY
Project Name:
Driver
12451 Piper Cub Terrace
Port St Lucie, FL
Date Drawn:
9/20/18
TABLES:
402.4 (25)
402.4 (28)
*LP Gas
*11" we del pres based on a
10 psi system
*BTU ext=350000
*BTU int=0
*longest int run=0
*longest ext run=15'
*shut off valves installed within 6'
of each appliance
*make up air by others if required