Loading...
HomeMy WebLinkAboutMOBILE HOME INSPECTION REPORTAll r com All u PLANNING & DEVELOPMENT SERVICE DEPARTMENT BUILDING & CODE REGULATIONS DIVISION 2300 Virginia Ave RECEIVED Fort Pierce, FL 34982 (772) 462-1557 S E P 06 20118 Mobile Home Inspection Report ST. Lucfe County, Permitting for permits to place or replace used Mobile / Manufactured homes must be accompanied by this Inspection Report and copies of both sides of the Title to the home. Mobile homes must be Wind Zone II certified. Year 41Manufacturer C = I0,1 Compliance (Print or type) c Date: Serial # HUD Plate # ��A�`v� i Length 0 Single Double Wind Zone N = Not in Compliance Fire Safety / Electrical. 1. Smoke Detector: installed Missing 2. Electrical System Checked: Exposed Wiring Other 3. Distribution Panel: Missing Loose Main Missing Breaker Missing Unplugged Opening Other 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire G CI receptacles not where required 5. Electrical Groun . ass' Main Panel Gas Pipe 0 Page 1 File copy Construction Exit Doors Operable: Front Back Other Exit Door Locks: Missing Inoperable Egress windows: Missing Inoperable Windows: Broken Glass Inoperable Screens: Missing Damaged Floor System: Joist Deecck_ina- Area Damaged Interior Paneling: Missing .. Loose Damaged Rodent Proofing: Bottom Board Pipe openings Other Leaks Apparent: Ceiling Doors Floor Roof 0. Vertical tie -down straps: Missing . Short Damaged 1. Structural modifications since manufactured: YES NO 2. Walls: Structurally Unsound Loose Weather tight Plumbing Trap: Missing Not connected Other . Plumbing fixtures: Missing Not installed Not Vented Relief Valve: Missing . Inoperable Other Drain Waste and Venting Piping: Missing Not supported Clean outs Use of fittings Not capped Heating and Air Conditioning Heating Appliances: Missing. Not Connected Other Deleted Heating/AC syste installed _ Other Thermostat: Missing Inoperable Air registers: Missing Inoperable . Ducts: Not sealed Missing Collapsed Gas furnace Water heater vent: Missing Loose Page 2 7. Return Air: To Furnace o A/ From rooms 8. Ranger Vent 600d TLI �: p9. Gas Valve: Accessible installed improperly f� 1' Ifs 10. Gas lines: Not capped _Not supported Kinked Notbonded 1. �s subject structure found to: be fifty.p%) or more damaged or deteriorated? YES 2. ill a remodelingNO permit be required? YES N0 The, provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent thanjthose standards required to be met in -the manufacture oIf mobile homes. Such provisions shall include, but not be limiti'Id to, standards for structural adequacy, plumbing,, heating, electrical systems, and'fire and life safety. FS 320.8232 IF ANY Y RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO' P BE 6FORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY A SE i�ARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS ' MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOICATED WITHIN ST. LUCIE COUNTY UNTIL THE.REQUIRED DOCUMEN TS HAVE BEEN SUP,IITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A JGISTEREDFLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX Date i By: *S19natureEngineer THEIR SEAL. �17� License #: v Revised 08/24/2010 Page 3