Loading...
HomeMy WebLinkAboutPRODUCT INFORMATION.i (912) 490-72(8 FAX: (912)490-7276 SOLD TO: F. deral Emergency M Plp Box 800 Berryville, VA 22611 SHIPTO: ,iIILLE/SELMA CUSTOMER: illl STOCK r� SCO"r=kT HOMES, Sales/Production Order Date: 11123/2009 SHINGLE: 11 WHITE DELX SHUTT#RS: NONE TILE: IN ROLL LINOLEUM THROUGH OUT IA/C - HEAT III ELECTRIC CENTRAL UNIT . I c[Ep ', 4 W'jl SERIAL NO. .R OM. I 146023SOUTHUFAS-FEM 14X64 3+1 N UNIT - UFAS ORDER BY: I g61•Fh9r' hF88'nty, Permitting J PO# HSFEHQ-09-D-1501 TASK# HSFEHQ-09-J-0001 SALES REP: HOUSE Draw Bar - Painted Red DECOR: COUNTERTOPS ALUMINUM KIT BACKSPLASH ALUMINUM KIT EDGING ALUMINUM BATH BACKSPLASH ALUMINUM BATH EDGING ALUMINUM TILE ENTRY NIA 11 STANDARD FEATURES IND ZONE 3 CONSTRUCTION IERMAL ZONE 2 - ROOF LOAD SOUTH ID CODE PER DAP/A VEW BRAKE AXLES W/NEW TIRES & 2 NEW IDLER AXLES ;8 FLOOR JOIST 16" O. C. w12X8 RIM JOIST 132" T&G NON -EMITTING PLYWOOD FLOOR DECKING .00R INSULATION. R-19 UNBACKED .00R COVER: LINOLEUM ROLL GOODS WEXTERIOR WALL STUDS 16" O.C. (WZ3) ALL INSULATION: R-19 BATT TALL 2X3 INTERIOR WALL STUDS 16" O.C. WIDE HALLWAYS .AT CEILINGS THROUGH OUT ESIDENTIAL CEILINGS - SEASPRAY FILING BOARD FASTENED W/FOAM SEAL TO TRUSSES 6" PLYWOOD ROOF SHEATHING, TRUSSES @ 16" O.C. ;LB ROOF UNDELAYMENT, SINGLE LAYER V500 ROOF VENTS 70F INSULATION: R-19 10 AMP MAIN PANEL LIGHT OVERHEAD LIGHTING-BRS HALL,KIT, LR, DR,BATH, INH BOX ETAL.EXT LIGHT AT EXT DOORS - NON -GLASS EXTERIOR RECEPT W/GFCI ELEC. SMOKE ALARMS W/BATTERY & STROBE " NOAA WEATHER RADIO W/STROBE W/BATTERY LUMB FOR WASHERIWIRE FOR ELEC DRYER INYL SIDING (WHITE) - DOUBLE DUTCH 4.5 8"'PLYWOOD EXT WALL SHEATHING i"INTERIOR PASSAGE DOORS, 24" CLOSET DOORS HINGES EACH DOOR EVER CHROME/NICKEL DOOR KNOBS RIVACY LOCK ON BATH DOOR LOOR.MOUNTED DOOR STOPS EXTERIOR DOORS - OUTSW/NG 36X80 WIDEADBOLTS ALUMINUM COUNTERTOPS & EDGING & BACKSPLASH 32":HEIGHT CABINETS - KIT & BATH KNOBS -ON CABINET DOORS SUI WHOLE ,HOUSE WATER CUTOFF /N UTILITY � l PEXWATER SYSTEM I+ 1 WATER CUTOFF THROUGH OUT at L,�. we BREAKER LOCKOUT - WATER HEATER 111VINYL DOUBLE GLAZE LOW-E WINDOWS WATERWEATER W/P&T RELIEF VALVE PIPED SINGLE -BATH LAV W/PORCELAIN BOWL TWO HANDLE CENTERSET ELEVATED, ELONGATED COMMODE 1.6 GALLON 607AADA:ROLL IN SHOWER w/SECURED FOLD DOWN SEAT DUALrSTA/NLESS STEEL KIT SINK W/TWO HANDLE CHROME METAL BASKET STRAINERS niciRIC 2.5 TON HEAT/COOL UNIT WICRV -15KW OVERHEAD SUPPLYDUCTS CABLE,JACK IN LR, PHONE JACKS LR & MST BR 18CF FROST FREE REFRIGERATOR W/FREEZER 30".SELFCLEANING ELEC RANGE - CONTROLS ON FRONT 307STDVERTICAL RANGE HOOD VENTED J S .CF`MICROWAVE, COUNTER TOP WICHILDLOCK 41 GALDUAL-ELEMENT WATER HEATER - 5#ABC. TYPE FIRE EXTINGUISHER 1"MINI:BLINDS, CHILD RESISTANT 170ATTEN STRIPS TO MATCH WALLBOARD 1"BATTEN CROWN & FLOOR MOULDING 1.";BATTEN MOULDING @ DOORS & WINDOWS 24=30"DOUBLE STRENGTH MIRRORS CENTERED AT LAV & CHEST/DRAWERS VAPOR -BARRIER TO EXTERIOR P-TRAP: GUARD @ SINKS FURNITURE ,PACKAGE LIVING ROOM: DINING AREA: BEDROOMS: (EACH) SLEEPER SOFA & ARM CHAIR 36"X60" METAL DR TABLE FULL SIZE BEDDING METAL COFFEE TABLE (6) METAL CHAIRS METAL CHEST OF DRAWERS ONE METAL END TABLE (2) METAL NIGHT STANDS IBARCODEJ 1702 '. a •; ' e _ Ofu1NGREQUIREMEUT-S;--F_EMA_UFAS-SDUT -- --- ROOF LOAD ZONE: SOUTH (20 PSF) THERMAL (U/0) ZONE: 2 WIND ZONE: 3 UNIT IDENTIFICATION: PAINTED RED DRAW BAR TYPE: MODEL: FEMA ALL -ELECTRIC MANUFACTURED HOME EXTERIOR LENGTH: 60 ft (box length) EXTERIOR WIDTH: 14 ft (maximum box width) ELECTRICAL SYSTEM - AMPS: 200A ELECTRICAL SYSTEM - VOLTS: 120/240 V RI a LLJ AUG -4 2009 O LL G C" QRome Fedml Mlnursctumd Construction Fn v And Safety SWdtrdt SaatBE HOMES, INC. P.O. BOX 1189 WAYCROSS. GA 31503 --€KAGE_CONTENS- - -- - ----- UFAS-S-1 COVER SHEET (THIS PAGE) UFAS-5-2 ELEVATIONS UFAS-S-3 FLOOR PLAN UFAS-S-4 ELECTRICAL PLAN UFAS-S-5 WATER DISTRIBUTION UFAS-S-6 DRAIN LINE UFAS-S-7 CROSS SECTION UFAS-S-8 HVAC UFAS-S-9 EXT WALL FRAMING UFAS-S-10 INT WALL FRAMING UFAS-5-11 TRUSS PLAN UFAS-S-12 SHEARWALL LAYOUT UFAS-S-13 BLOCKING PLAN UFAS-S-14 OPTIONAL SPRINKLER PLAN (n r � C) v� fD f-TT X o 0 c M � ® C cwa M CD �3 Lo P.S.O. "" 1464 (820 sq.ft.) 07/29/2009 BEDROOMS: 3 07/29/2009 1 BATHS: 1 146023FEM-UFAS-S N.T.S. NO.: F SHEET 146023FEM No.: UFAS-S-1 4 WALL #1 WALL #2 -0 ? C3 AUG -4 1009 Q a � n m WALL #3 And secery slenaera+ _ �Btlt DATE: N BY: P.S.O. HOMES, [NC. 07/29/2009 WAY ROgq GAS]1501 REV: 07/29/2009 1464 (820 sq.ft.) lees: 3 1 WALL #4 N.T.S. _... LFRAMING 3 NOWALAS-S-9 UFAS-S-9 14602 3 F E M rr< ■tA� ■ WALL #5 WALL #6 AI. ■'1- -' . 11 1 11 ■ rr■ � N N ■ W �■ ■ pr WALL #7 WALL #8 WALL #9 Ail ■ t'l W. 1/% WALL #10 WALL #11 WALL ##12 WALL #13 WALL #14 WALL #15 WALL #16 NM 1RTY APPROVAL-- ENGINEERING APPROVAL• (IF APPLICABLE) ® ' n ■ IY r, ■ • N ■ Uf 1■ NI4 tlN ■ tlil'1 ■U'I ■ r■ tY■ . UJI 'c -0 WALL #17 WALL #18 WALL #19 WALL #20 AUG -a zoos Cam. Federal Manufutured m 146023FEM-UFAS-S Home ContWedon O . And Safely Standards DRAWN BY: SIZE: SCALE: P.S.O. 14x64 (820 sq.it.) DRAWING NUMBER: N.T.S. DATE: HOMES, INC. BEDROOMS: TITLE: 07/29/2009 3 INT WALL FRAMING 146023 F E M P.O. BOX 1189 pEV: WAYCROSS, GA 31503 BATHS: DRAWING NO.: 07/29/2009 1 UFAS-S-10 O zwQ- D W -0 AUG -4 2009 0 C" Federal Manufactured M Home Construction v And Safety Standards 5aortBilt HOMES, INC. P.O. BOX 1189 FOOTING PAD P.S.O. "'; 1464 (820 07/29/2009 1 BEDROOMS: 3 07/29/2009 BATHS: 1 146023FEM-UFAS-S N.T.S. ....,.� .. ., BLOCKING PLAN 14 6 0 2 3 F E M 3 No.: UFAS-5-13 10'-0" CLOSET E•PB 213 s BEDROOM#1 � s c 6 5 db W '0 3 "C7 AUG -4 2009 Q' QHome Federal Manufactured Coashucdon m v And Safety Standards 60'-0" 28'-7 1 /2" 11'-5 1 /2" 6 6 P Hf WP 6 GFI UT 1TY 6 2 6 LIVING ROOM lqp CLOSET 7 DRYER WlSHE0. ' s 6 BEDROOM #2##22 7 BEDROOM #3 I4TH#1 v KITCHEN s 1 A D 7 a • 5 1 n 6 �♦ s z D 6 8 GFl DINING AREA 1 6, _ D r N gFl 14 7 O O GFl 7 3 SA 7 '1 ® swP I 9'-6" 8'-1 w 22'-4" 9'-11" ELECTRICAL CIRCUIT SCHEDULE CIRCUIT DESCRIPTION BREAKER (AMP) GA. WIRE VOLTS 1 PORTABLE APPLIANCE 20 12 120 2 PORTABLE APPLIANCE 20 12 120 3 PORTABLE APPLIANCE 20 12 120 4 PORTABLE APPLIANCE 20 12 120 5 GENERALLIGHTING 15 14 120 6 GENERALLIGHTING 35 14 120 7 GENERALLIGHTING 15 14 120 8 GENERALLIGHTING 15 14 120 9 GENERAL LIGHTING . 15 14 120 10 GENERAL LIGHTING 15 14 120 11 GFCI CIRCUIT 15 14 120 12 FURNACE (ELECTRIC) SEE MFG INSTALLATION INSTRUCTIONS. 13 FURNACE (GAS) SEE MFG INSTALLATION INSTRUCTIONS. 14 WATER HEATER SEE MFG INSTALLATION INSTRUCTIONS. 15 WASHER RECEPTACLE 20 12 120 16 DRYER RECEPTACLE 30 10 240 17 RANGE (ELECTRIC) 40 8 240 18 DISHWASHER 15 14 120 19 GARBAGE DISPOSAL 15 14 120 20 SMOKE ALARM SEE MFG INSTALLATION INSTRUCTIONS. 21 BATHROOM 20 12 120 22 UNASSIGNED 23 UNASSIGNED 2 A55 G ED P.O. BOX 1189 (CROSS, GA 3 FLOOR PLAN SYMBOL SCHEDULE SYMBOL DESCRIPTION ® ELECTRICAL PANEL BOX - T THERMOSTAT SA SMOKE ALARM LIGHTING FIXTURE WP EXTERIOR LIGHTING FIXTURE STD. 15 AMP RECEPTACLE STD. 20 AMP RECEPTACLE WP EXTERIOR 1S AMP RECEPTACLE GFI STD. 20 AMP GFCI RECEPTACLE GFI STD. 15 AMP GFCI RECEPTACLE RECEPTACLE ON 240 VOLTS CIRCUIT SWITCH EXHAUSTFAN RANGE HOOD _ 146023FEM-UFAS-S P.S.O. SIZE: 14%64 (820 sq.ft.) SCALE: N T.S. DRAWING NUMBER: BEDROOMS: TITLE: 146023 F E M 07/29/2009 3 ELECTRICAL PLAN 07/29/2009 BATHS: 1 DRAWING NO.- UFAS-S-4 Do I V/wl 250 PLF / 300" L. MIN. O jffw4w . D W ro � ro AUG -4 2009 00 G IL G n. Federal Mautecmred m QHome Conmuctim v And Sdety Stmdardi 60,-0• WIND ZONE3 SHEARWALL LAYOUT MAXIMUM WALL HEIGHT= 8'-0" ROOF PITCH LESS THAN 20" P.O. BOX 1189 (CROSS. GA 3 �W-1 ) PLF / 112" L. MIN. 146023FEM-UFAS-S P.S.O. SIZE: 14X64 (820 Sq.ft.) SCALE: N.T.S. DRAWING NUMBER: BEDROOMS: TITLE: 146023 F E M 07/29/2009 3 SHEARWALL LAYOUT 07/29/2009 BATHS: 1 DRAWING NO.: UFAS-S-12 WATER HEATER EXTERIOR ACCESS STEPS NOT —� PROVIDED BY FACTORY FACTORY INSTALLED A/C HEATING UNIT WINDOW SCHEDULE FRONT ENDWALL END) SYMBOL WIDTH xHEIGHT TYPE(.) AREA LIGHT VENT (HITCH A 30"x1 VS 11.2 9.7 1 S ELEVATION DOOR SCHEDULE SYMBOL WIDTH x HEIGHT ROUGH OPENING UGHT VENT AP 1 36"W x 76"H VS N/A I I N/A Ltj O AUG -4 2009 CC O a dc d. Federal Manufactured Hook Conshuc*n m v And Safety Standarda SOME HOMES, INC. P.O. BOX 1189 WAYCROSS, GA 31503 PROVIDED BY FACTORY FRONT SIDEWALL ELEVATION VINYL SIDING OR SIMILAR (COLOR: WHITE OR OFF-WHITE) K SIDEWALL -EVATI ON VINYL SIDING OR SIMILAR (COL R: WHITE OROOFF-WHITE) REAR ENDWALL (COLOR: VINYL SIDING SIMILAR (NON -HITCH END) °OLOR:W WHITE P.S.O. — 14x64 (820 07/29/2009 BEDROOMS: 3 07/29/2009 1 BATHS: 1 ELEVATION / OR OFF-WHITE) I ; 146023FEM-UFAS-S N.T.S. DRAWING NUMBER: ELEVATIONS 146023 F E M 40 ° UFAS-S-2 EXTERIOR WALL OF UNIT I INN) I ALLtL) PAN DRAIN LINES THROUGH FLOOR SYSTEM SITE INSTALLED PAN DRAIN LINE. DRAIN SLOPE PER FOOT STRAPPED 4'—O" O.C. Ed jOR I I PICAL DOR SYSTEM lu 0 MAY 16 2666 m a PedantManrad llama Cootbacli6velion And !n Safely Sualdmb swtNS DRAWING No. z °PL-11 M,1�f DAIEI ATER IIEATER GRAIN PANTALLATION 0. .. LAST MODEL REVISION DATE: N/A REFER TO DAPIA DESIGN DRAWINGS FOR 3/8" STRUCTURAL RATED SPECIFIC REQUIREMENTS. SHEATING 2x6 EXTERIOR WALLS AT 16" O.C. (DOUBLED IN END ZONES) 3/8" MINIMUM STRUCTURAL RATED SHEATHING ELIXIR S-20F AT SHEARWALL LOCATIONS WHERE REQUIRED (IDENTIFIED WITH GREEN PAINT) Q RINI. W 'O AUG -4 2009 G n- C CL Fed.&I Mmufaatued m v MdSdely Stm&ftb 2x6 TOP PLATE ALL EXTERIOR WALLS FINISH Sx6 BOTTOM PLATE ALL EXTERIOR WALLS swtollt HOMES, INC. P.O. BOX 1189 CEILING BOARD 2x3 INTERIOR WALLS AT 16" O.C. P.S.O. 07/29/2009 07/29/2009 (DOUBLED IN END ZONES) 20 PSF LL 146023FEM-UFAS-S 14x64 (820 SQ.ft.) SCALE: N.T.S. DRAWING NUMBER: )MS: 3 TITLE: CROSS SECTION 1 DRAWING NO.: UFAS-S-7 146023 F E M ALL RISERS TO BE 3/8" I.D. TYPE "L" COPPER WITH BRASS CONNECTORS 7= 11;) °V/ rr; uj C3 AUG -4 2009 0"CL C CX F".c ufecnaed omc oamve6on rTl And Sddy Slnndud3 EXTERIOR FAUCET 3/4" MASTER �\ SHUT-OFF VALVE / \ KIT. SINK. " INLET FULL 3/4" / REUEF 3/4" WASHER 3/4" � 3/4" \ 3/4" I W/r I \ 3/4" v SHOWER \ I� W.C. FRESH WATER SUPPLY SYSTEM ALL WATER PIPES ARE 1/2" DIA. UNLESS WHERE NOTED COLD ---------4 HOT 146023FEM-UFAS-S �BJLLP.S.O. DRAWN BY: SIZE: 14x64 (820 sq.ft.) SCALE: N.T.S. DRAWING NUMBER: C. 1189 14 60 2 3 F E M DATE: 07/29/2009 BEDROOMS: 3 TITLE: DISTRIBUTION O BWATE OX WAYCROSS. GA 31503 R� 07/29/2009 BATHS: 1 DRAWING NOR UFAS-S-5 AV- WASHER VTR 1j S o. TUB 2x, jx1 I ST , i LTL 2 LTV I LTTY , LTL 1J-45' EL WASTE & DRAIN SYSTEM 2X1�X7� ,A-45' EL AVSINK 14 S 1 j" PIPE 2 LTL LTTY 1 -45'. EL 0. 2° PIPE 3X3X2 1J-45' EL Av. LAV. 1j LTL 3 LTL LTTY ' S 3" PIPE 3 45' EL -= 0• 14 LTL 3X3X7 LTTY 45' G,� 0 4x3 CLOSET EL THREADED END Mq-I LOCATED NOT LESS THAN 2'0" BUT NOT MORE THAN 3'-0" BEHIND REAR AXLE THIRD PARTY APPROVAL: ENGINEERING APPROVAL' (IF APPLICABLE) ' Lu AUG -4 2009 C IL IL Fede�IMNura<a.�a m 146023FEM-UFAS-S QHome Commotion Ands rdy Sundu& C3 scatoilt DRAWN BY: P.S.O. SIZE: SCALE: 14x64 (820 sq.it.) DRAWING NUMBER: N.T.S. P.O. BOX INC. DATE: 07/29/2009 07/29/2009 BEDROOMS: TITLE: 3 LINE 146023 F E M WAYCROSS. GA 31503 REV• 07/29/2009 BATHS: DRAWIN13NO.: 1 UFAS-S-6 Y U�- 1� O. coI I 1 n li A co I 77 I 259 PLF J IDO" L, latl lf, m• I T : 1t3'_0" y TS. r-- 0 co T O N N m Lu t] N , . 0 AUG -4 2009 N d � � _ rdml LWde6q� ,gOiY ATd 8aP'U 6�M L � N U 0 H efl'—on 28'-7 t/2' 1451 PLF 1 112° t, Nrlfl. d-S" M INI D ZO VE7 SHEARWALL LAYOUT FRAXIMUM WALL IIEIGILT • 8'-U` Ror)F PITCH LESS TI INN 20' INC. .ILA Ua 250 PLF / 112" L, MIN. 515 PLF / I.Oo' L. MIN, 146023FEWU FAS-& P's n,ne��n�1920sqqit.) no f603FcBATHS: 1 FASSd2 co To: Cathy Page 12 of 12 PPROvE pD�1�jy� . O GIAG dd 2018-09-12 13:11:33 (GMT) 18132001123 From: Rocky Creek Retirement s] .] N. ;enf 1 ,IIG 46 .Ptl D9 0 6 L' d dZZ:ZO "86 L idac a) � I 0) U 28'-7 I/2" O LY U iD CA CD iJ w s r F O CLUBL•'f N a L'i Ty T J 0 ...Alm N co OD r jTEDR901f l l� r KITCIIE N TEiNI ; U" CC):� ,� EI 41 O CD o N .. 1dVIN(] ROOM MA)SET nom0 e T ` RI:DAOOM 03 ' s 9IiVIlUU3r162 1G ATLF.A 1 CIP.CUR CESRLL?7iON I+a FLOOR PLAN SYMBOL SSCHEDULE aT>dRa of EX T. THERMU$TAT SA 6MVKE hlAFth] ---- UMW.NGFIKWSE EKi_.RIVRiiGIiTING MIME STD. 15 AMP RECEPTACLE STO. 20 ANIP RECEPTACLE EKTERIOR INAPAP RECERACLE WP ST0.20AL1PGFCIRECE?TACLE CFI S7U..L5 AMP GFCIHELEPTACLC CFI AECEPiACLE OR24a VOLTSCIRCUT sPAT6! [YIIAUST FAN �. RANGE FLOW 146023FERA• R-JAM-0 SCALE DnAwttlG IIVIABGRt P,5.0. site T4xGa+A9Dsq.R.) N�T3.^^ B> onoo+Iei q 1411Et EIECTRICAt PLAN 14 602 3 F E ill D7719/2D09 , _{I nWnnnnnn IBx;l1l: 1 DRAWiNOT� UTAS-S-4 60'-0" 10'-0" 28'-7 1 /2" 11'-5 1 /2" 23'— ' j1'8'�1' ® I ® ® I 2 OEGRESS CLOSET GTIun I : AREA: S.J. 27 � 0 0 3680 AREA: T."o R• 1 2480 MIN. LIGHT: 0.0 R• I� 1J I LIVING ROOM CLOSET n 1 MIN. VENT: 0.0 R• J._ 10'•7.5' a 9'-1• 2480 51 1p PPEA: 96.9 R• 18 MIN. DGHT: 7.72 R• � BED SOOB #02 a B9 D SOOM B3 MIN. VENT: J.66 R• _ KITCHEN MIN. LtGxrB9714 rt• MINA.�LIGHT07B.57 R• BEDROOM #1 3680 Tao• ■ 9'-5• LIVING ROOM, KITCHEN, 71IN. VEHT: J.S] R• 36 AREA: 7J.9 ft- . 7 9•-4s•. Ix'-e• AND DINING AREA COMBINED - BATH ., MIN. LIEN: .0 R• u AREA: 109.1 R• 9••5• • T-x' MIN. VENT: 0.0 R• COMPLY WITH 3280.109(a) 11 2 �•- MIN. LIGHT: 8.77 R• AREA: 67.5 R• ARTIRCIAL LIGHT/ i° 7 2 71IN. VENT: 4.J6 ft• le MIN. LIGHT: 0.OR• • VENT ASSIST. LLpp MIN. VENT: 0.0 R• pm A 3680 Lp ARTIFlOAL LIGHT/ 14 I SIST. •HALLWAY 24806 R•'S••3'-7' 3680 in T .1 ft• RA GRILL I! O p p N [MIARESA."41 N.LIG: 0.0 R• TN DOOR I MIN. VENT• 0.0 ft• 0 3 EGRESS O EGRESS ® 53'-10' ® 2Y-6' 21'-6- ® 3'-4' 10'-0" 9'-8" 8'-1" 22'-4" THIRD PARTY APPROVAL• ENGINEERING APPROVAL, (IF APPLICABLE) WINDOW SCHEDULE SYMBOL I WIDTH xHEIGHT TYPE(') AREA LIGHT VENT A 30" x 53" VS 11.2 9.7 5 DOOR SCHEDULE SYMBOL WIDTH It HEIGHT ROUGHOPENING LIGHT VENT Lu 1 I 36"W x 76"H VS N/A N/A a AUG -4 2009 G a" C 146023FEM-UFAS-S Q Fedow Mmur9crxw m NO=C6GSWCbOR And SafetyStanduds ��� DRAWN BY: SIZE: SCALE: DRAWING NUMBER: P.S.O. 14x64 (820 sq.ft.) N.T.S. DATE: BEDROOMS: TITLE: 146023 F E M HOMES, INC. 07/29/2009 3 FLOOR PLAN P.O. BOX 1189 REV: 07/29/2009 BATHS: 1 DRAWING NO.: UFAS-5-3 WAYCROSS GA 31503 LICATION ENGINEERING . HEATING AND COOLING lilt Homes, Inc. Fulford Road ross, GA 31503 MAG nufacturer's Model #: 146023FEM System Type: OVERHEAD STRAIGHT D.B. FOR WALL MOUNT UNIT Prepared By LaSalle Air Systems 8/3/2009 (Method & output C 20081 All rights reserved: this information proprietary to LaSalle Bristol Co. & clients. Calculations on this page are based on design parameters set forth in ASHRAE and ACCA Manuals J and D. Design calculations are based on worst case orientation. Room loads may vary based on actual conditions. ENTIRE HOUSE VALUES - DESIGN ZONE: 3 (HUD) COOLING LOAD: 15,446 Btuh based on outside temp of 97 ° F with inside temp reduced to 75 F. HEATING LOAD: 34,187 Btuh based on outside temp of -10 ° F with inside temp raised to 70 ° F. OVERALL HEAT LOSS COEFFICIENT: 0.073 CONSTRUCTION DETAILS & U FACTORS (19-19-19) TOTAL FLOOR AREA: 820.00 s.f. TRUE OUTSIDE PERIMETER: 147.33 ft LOW CEILING HEIGHT: 96 in. HIGH CEILING HEIGHT: 96 in. NET WALL AREA: 1071.17 s.f. ROOF: 0.052 FLOOR DUCTS (U): 0 TOTAL Low-E window 67.50 s.f. WALLS: 0.059 ATTIC DUCTS (U): 0.238 TOTAL S.G.O. 0.00 s.f. FLOOR: 0.054 EXT. DUCTS (U): 0.238 TOTAL Glass Block 0.00 s.f. Low-E wh 0.360 ATTIC DUCT AREA: 113.06 s.f exposed TOTAL WINDOW4 0.00 s.f. S.G.D. 0.790 EXT. DUCT AREA: 0 s.f exposed TOTAL DOOR1 AREA: 40.00 s.f. Glass Bic 0.790 PEOPLE: 4 TOTAL DOOR2 AREA: 0.00 s.f. WINDOVI 0.790 FIREPLACES: 0 WINDOW % OF FLOOR 8.23 % DOOR1: 0.280 DUCT GAIN: 2157 Btuh WINDOW % OF WALL 5.73 % DOOR2: 0.670 DUCT LOSS: 3597 Btuh Mach. Ventilation per 0.5 exchange/hour: 52 ofm SUMMER INFILTR: 54.8 cfm LATENT GAIN: 2735 Btuh WINTER INFILTR: 131.5 cfm ROOM BY ROOM VALUES 862.1 FPM, max velocity in trunk# 2 Requirements based on actual house loads Cooling Air Heating Air Maximum A/C capacity Without incorporating duct friction losses. Values for Values for 48 15 KW per MHCSS 3280.715 HEATING COOLING CFM 3 ton unit Gas Elec Calibrated Blower Test ROOM NAME LOSS (Btu) GAIN (Btu) DIST CFM Btuh CFM Btuh Btuh Btuh Living/Dining Room 6,237 3,082 108 267 8,760 267 10,687 11,765 9,035 Kitchen 5,553 2,571 90 191 6,260 191 7,637 8,407 6,445 Bath#1 2,760 1,177 39 137 4,503 137 5,493 6,04E . 4,686 Utility 2,278 829 40 - - - - _ _ Bedroom #1 5,793 2,576 92 212 6,951 212 8,481 9,336 7,148 Bedroom #2 4,163 2.027 70 136 4,468 136 5,451 6,001 4,650 Bedroom#3 5,847 2,616 92 136 4,468 136 5,451 6,0D1 4,650 Hall 1,555 568 31 - - - TOTALS 34,187 15,446 563 1,081 35,410 1,081 43,200 47,558 36,615 Im NW4 LU AUG -4 2009 C a a M M SaW Stdu&v 146023FEM-UFAS-S