Loading...
HomeMy WebLinkAboutNOAARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) ,RD AND CODE ADMINISTRATION DIVISION DTICE OF ACCEPTANCE (NO. P¢'lyglass USA, Inc. 1 II 1 W. Newport Center Drive D�erfield Beach, FL 33442 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.gov/economy SCARNNEID 51 Lucie CoUnly NOA is being issued under the applicable rules and regulations governing the use of construction materials. The mentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). s NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this duct or material tested for quality assurance purposes. If this product or material fails to perform in the accepted finer, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or pend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, is determined by Miami -Dade County Product Control Section that this product or material fails to meet the uirements of the applicable building code. s product is approved as described herein, and has been designed to comply with the Florida Building Code luding the High Velocity Hurricane Zone of the Florida Building Code. : Polyglass Modified Bitumen Roof System Over Wood Decks TG: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following "Miami -Dade County Product Control Approved", unless otherwise noted herein. ENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change the applicable building code negatively affecting the performance of this product. ERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the aerials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section this -NOA shall be cause for termination and removal of NOA. DVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the piration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done its entirety. 'ECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and be available for inspection at the job site at the request of the Building Official. NOA renews NOA415-0928.05 and consists of pages 1 through 63. submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0824.09 Expiration Date: 09/13/22 Approval Date: 09/14/17 Page 1 of 63 brane Type: SBS/APP Type 1: Wood, Non- Insulated Description: Min. 19/32" plywood or wood plank attached to structural supports at a maximum of 24" o.c. with #8 screws at 6" o.c. m Type E(1): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. General and System Limitations apply. Sheet: One ply of Elastobase. Polyglass APP Base*, Polyglass G2 Base, Polyglass HT Base 650, XtraFlex SBS Glass Base, XtraFlex SBS HT Base 650 fastened to the deck as described below: *Requires torch -applied ply or cap sheet. #1: (Polyglass APP Base or Polyglass G2 Base only) Attach base sheet using 11 ga. annular ring shank and 1-5/8" diameter tin caps spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the center of the sheet #2: Attach base sheet using OMG #14 Roofgrip fasteners with Flat Bottom Metal Plates, Dekfast 14 with Dekfast Galvalume Steel Hex Plates, Polygrip Fasteners #14 with Polygrip Hex Plates or Trufast #14 HD Fastener with Trufast 3" Metal Insulation Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet. Sheet: One or more plies of Elastobase, Elastobase P, Elastoflex S6, Elastoflex V, Elastoflex V 2.5, tional) Polyglass HT Base 650, XtraFlex SBS Glass Base, XtraFlex SBS Glass Interply, XtraFlex SBS HT Base 650, XtraFlex SBS Poly Base, one or more plies of Type IV or VI ply sheet adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Or One ply of Elastoflex SA V*, Elastoflex SA V FR*, Elastoflex SA V PLUS*, Elastoflex SA V PLUS FR* or XtraFlex SBS Base SA* self -adhered. *Requires torch -applied ply or cap sheet. nbrane: One ply of Polybond, P, oollybonndd Gam, Polyflex, Polyflex G, Polyflex G FR, Polyfresko G, Polyfresko G FR, XtraFlex APP G, XtraFlex APP S, XtraFlex Kool APP G torch ap In i ed. Or One ply of Elastoflex S6 G, Elastoflex S6 G FR, Elastoflex VG, Elastoflex VG FR, Elastoshield TSG, Elastoshield TSG FR, Polyfresko G SBS, Polyfresko G SBS FR or XtraFlex SBS Poly G torch or hot asphalt applied. Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. DesignO f; (See General Limitation #7) NOA No.: 17-0824.09 Expiration Date: 09/13/22 Approval Date: 09/14/17 Page 47 of 63 DECK SYSTEM LIMITATIONS: 1. 11 A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or mechanically attached using the fastening pattern of the top layer. 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. s 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 121bs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 2751bf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchorlbase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 11 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 17-0824.09 Expiration Date: 09/13/22 Approval Date: 09/14/17 Page 63 of 63 T FU.R14571 - Roofing Systems _ Page 8 of 17 Ply Sheet (Optional): — One or more layers "DUFLEX", "Xtraflex APP S" or "POLYFLEX" (heat fused), "ELASTOBASE", 'XtraFlex SBS GLASS Base", "ELASTOFLEX V", "Xtraflex SBS Glass Interply", "ELASTOFLEX V-C" or Type G2 base sheet (hot mopped or mechanically fastened). Membrane: — "Polyflex G FR", "XtraFlex APP G HP", heat fused. 4 . Deck: C-15/32 Incline: 1/2 Barrier Board: — Minimum 1/2 in. thick gypsum board or minimum 1/4 in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard:' Roofboard" or minmum 1/4-in. thickUnited States Gypsum Co. "SECUROCKTM Roof Board Type FRX-G" are used directly over the combustible roof deck with all buttjoints staggered a minimum of 6-in. from plywood roof deck joints. Base Sheet (Optional): — Type G2 Base sheet, mechanically fastened. Ply Sheet: — "Elastoflex SA V FR Base", (self -adhered). Membrane: — "Polykool SA R" or "Polyreflect", (self -adhered). 46. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocya nu rate, glass fiber, perlite/polyisocyanurate composite, perlite/urethane composite, any thickness. Base Sheet: — One or more layers "DUFLEX", "Xtraflex APP S" or "POLYFLEX", heat fused or mechanically fastened; or one or more layers "ELASTOBASE", "Elastobase Vented Base", "XtraFlex SBS GLASS Base", "ELASTOFLEX V", "Xtraflex SBS Glass Interply" or Type G2, hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more layers "DUFLEX", "Xtraflex APP S" or "POLYFLEX", heat fused; or one or more plies "ELASTOBASE", "Elastobase Vented Base", "XtraFlex SBS GLASS Base", "ELASTOFLEX V", "Xtraflex SBS Glass Interply", "ELASTOFLEX V-C" or Type G2, hot mopped or mechanically fastened. Membrane: — "Polyflex G FR" or "XtraFlex APP G HP", heat fused. Deck: C-15/32 Incline: 1/2 Insulation: — Polyisocyanurate (2-in. thick minimum), glass fiber (15/16-in. thick minimum), perl ite/polyisocya n u rate composite, perlite/urethane composite (2-in. thick minimum). Barrier Board: — Minimum 1/4 in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard'" Roofboard", United States Gypsum Co. "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX), National Gypsum "DEXcell Glass Mat Roof Board" or "DEXcell FV Glass Mat Roof Board" mechanically fastened with all butt joints staggered a minimum of 6-in. from the plywood roof deck joints. Base Sheet: — "ELASTOFLEX S6", "XtraFlex SBS POLY Base", "ELASTOFLEX P-C" (heat fused or mechanically fastened). Ply Sheet: — "ELASTOFLEX S6", "XtraFlex SBS POLY Base", "ELASTOFLEX P-C" (heat fused or mechanically fastened). Membrane: — "ELASTOFLEX S6 G FR", "ELASTOFLEX S6 G-C FR" or "POLYFRESKO G SBS FR", (heat fused). Deck: NC Incline: 1 Insulation (Optional): — Polyisocyanurate, perlite, wood fiber or polyisocyanurate/perlite board, any thickness. Base Sheet: — "ELASTOBASE", "XtraFlex SBS GLASS Base" (poly/sand), mechanically fastened or "Polyflex SA Base", "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT" (self -adhered) Ply Sheet (Optional): — "ELASTOBASE", "XtraFlex SBS GLASS Base" (poly/sand), heat fused or mechanically fastened, or "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", (self -adhered). Membrane: — "POLYFLEX SA P FR", "POLYFRESKO G SA P FR", "ELASTOFLEX SA P FR", "POLYFRESKO G SBS SA P FR", "ELASTOFLEX SA' FR HT", (self -adhered) or "POLYFLEX G FP "XtraFlex APP G HP", "Xtraflex APP G FR", "POLYFRESKO G FR", "DUFLEX G FR", "XtraFlex APP Dual", "ELASTOFLEX S6 G FR", "POLYFRESKO G SBS FR", "ELASTOFLEX VG FR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY G T", "XtraFlex SBS GLASS G", "XtraFlex SBS GLASS GT" or "ELASTOSHIELD TS G FR", heat fused. Deck: C-15/32 Incline: 2 Insulation (Optional): — Polyisocya n u rate, perlite, wood fiber or polyisocyanurate/perlite board, any thickness. Base Sheet: — "ELASTOBASE" or "Elastobase Vented Base", mechanically fastened; or "ELASTOFLEX SA V FR", self -adhered. Ply Sheet (Optional): — "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", self -adhered. Membrane: — "POLYFLEX SA P FR", "POLYFRESKO G SA P FR", "ELASTOFLEX SA P FR" or "POLYFRESKO G SBS SA P FR", self -adhered; or "DUFLEX G FR", "XtraFlex APP Dual", "POLYFLEX G FR", "XtraFlex APP G HP", "Xtraflex APP G FR", "ELASTOFLEX S6 G FR", "POLYFRESKO G SBS FR", "ELASTOFLEX VG FR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY G T", "XtraFlex SBS GLASS G", "XtraFlex SBS GLASS GT" or "ELASTOSHIELD TS G FR", heat fused. Deck: NC Incline: 1/2 Insulation: —Polyisocyanurate (2 in. thick minimum), glass fiber (15/16 in. thick minimum), perl ite/po lyisocya n u rate composite, perlite/urethane composite (2 in. min). Barrier Board (optional): — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard'" Roofboard", "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard'" Roofboard" or 1/4 in. min United States Gypsum Co. SECUROCK@ Glass -Mat Roof Board (Type SGMRX), National Gypsum "DEXcell Glass Mat Roof Board" or "DEXcell FV Glass Mat R, mechanically fastened. Base Sheet: — "ELASTOFLEX V", "ELASTOSHIELD HT", "ELASTOSHIELD TS", "ELASTOFLEX S6", "XtraFlex SBS POLY Base", "ELASTOFLEX P-C" (heat fused or mechanically fastened). Membrane: — "ELASTOFLEX V G", ELASTOFLEX V G FR", "ELASTOSHIELD TS G FR", "ELASTOFLEX S6 G", "ELASTOFLEX S6 G FR", "ELASTOFLEX S6 G-C" or "POLYFRESKO G SBS", (heat fused). Deck: C-15/32 Incline: 1/2 Insulation: — Polyisocya n u rate (2 in. thick minimum), glass fiber (15/16 in. thick minimum), perlite/polyisocyanurate composite, perlite/urethane composite (2 in. min). Mechanically attached, hot asphalt adhered or foam adhered. Barrier Board: — Minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard'" Roofboard, DensDeck Prime@, or -minimum 1/4-in, thick United States Gypsum Co. "SECUROCK@ Roof Board" (Type FRX-G)" or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX) hot asphalt adhered or foam adhered. Base Sheet: — "ELASTOFLEX V", "ELASTOSHIELD HT" ,"ELASTOSHIELD TS", "ELASTOFLEX S61', "XtraFlex SBS POLY Base", "ELASTOFLEX P-C" hot mopped or torch applied. Membrane: — "ELASTOFLEX V G", ELASTOFLEX V G FR", "ELASTOSHIELD TS G FR", "ELASTOFLEX S6 G", "ELASTOFLEX S6 G FR", "ELASTOFLEX S6 G-C" or "POLYFRESKO G SBS", (heat fused). ://database.ul.com/cgi-bin/XYV/template/LISEXT/l FRAME/showpage.html?name=T... 9/18/2018