Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE 6-11-051 y P -4 177,3y ,4 `I!I ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs • EnergyGauge F1aCom v1.22 FORM 40OA-2001 Whole Building Performance Method for Commercial Buildings urisdiction: FORT PIERCE, ST LUCIE COUNTY, FL (661100) Short Desc: SSI 2733 Project: SSI 2733 Owner: SSI Address: FT PIERCE FT PIERCE o r NP City: FT PIERCE State: FL PermitNo: 0 sly Zip: 0 Storeys: 1 a Lucie County Type: Office Bu YP (Business) GrossArea: 1639 Class: New Finished building Net Area: 1639 Max Tonnage: 7 (if (Efferent, write.in) Compliance Summary. omponent Design Criteria Result Toss Energy Use 81.35 100.00 PASSES I ther Envelope Requirements - A PASSES I IILIGHTING CONTROLS PASSES EXTERNAL LIGHTING PASSES AC SYSTEM PASSES PLANT PASSES ATER HEATING SYSTEMS PASSES P. PING SYSTEMS PASSES N. et all required compliance from Check List? Yes/No/NA MPOR • TANT NOTE: An input report Pram -Out from EnergyGauge FlaCom'of - 11 this design building must be submitted along with this -Compliance Report. 5 y , 61111 5 EnergyGauge FlaCom FLCCSB v1.22 1 ,i COMPLIANCE CERTIFICATION: hereby certify that the plans and Review of the plans and specifications covered by this pecifications covered by this calculation are calculation indicates compliance with the Florida Energy compliance- with the Florida Energy Code. Before construction is completed, this building will be fficiency Code. inspected for compliance in accordance with Section 553.908, F.S. REPARED BY: GEORGE E FINK _ BUILDING OFFICIAL: pp DATE: io— i C�J� DATE: hereby certify that this building is in compliance' ' ith the Florida Energy Efficiency Code. MINER AGENT: =® -•. DATE: I required .by Florida law, I hereby certify (*) that the system design is in .. ompliance with the Florida Energy Code. REGISTRATION No. CIMECT �ECTRICAL SYSTEM DESIGNER: GHTING SYSTEM: DESIGNER:. --, `C� jZ C _ j `7 b 6 7' ECHANICAL SYSTEM DESIGNER:. i u << P II UMBING SYSTEM DESIGNER: (*) • ignature is required where Florida Law requires design to be performed by registered design professionals. Tyr 6d names and registration numbers may be used where all relevant information is contained on signed/sealed Planq 6111105 EnergyG'auge F1aCom FLCCSB v1.22 2 ect: SSI 2733 SSI 2733 Office (Business) ition: FORT PIERCE, ST LUCIE COUNTY, FL (661100) A File: DAYTONABEACH.TMY) Whole Building Compliance Design Total 81.35 Reference 100.00 ELECTRICITY 81.35 100.00 AREA LIGHTS 14.65 25.40 MISC EQUIPMT 18.15 18.15 PUMPS & MISC 0.08 0.08 SPACE COOL 18.57 26.48 VENT FANS 29.89 29.89 edits & Penalties (if any): Modified Pints: = 81.35' PASSES ject: SSI2733 SSI 2733 e: Office (Business) i ition: FORT PIERCE, ST LUCIE COUNTY, FL (661100) F :A File: DAYTONABEACH.TMY), Other Envelope. Requirements m Zone Description Design Limit Meet Req. �o1Rf1 PrOZol Exterior Roof - Max Uo Limit 0.05 0.09 Yes -ets Other Envelope Requirements d 6/11/ 5 EnergyGauge F1aCom FLCCSB 'v1.22 3 I Project- SSI2733 SSI2733 i,itle: Hype: Office (Business) iiocation: FORT PIERCE, ST LUCIE COUNTY, FL (661100) i, EA File: DAYTONABEACH.TMY) External Lighting Compliance escription Category Allowance Area or Length ELPA CLP 4 (W/Unit) or No. of Units (W) (W) (Sgft or ft). xt Light 1 Exit (with or without Canopy) 25.00 3.0 75 75 xt Light 2 Exit (with or without Canopy) 25.00 3.0 75 75 esign: 150 (W) PASSES lowance: 150 (W) Pgoject: SSI2733' Ti le: SSI 2733 Ty e: Office (Business) Lc nation: FORT PIERCE, ST LUCIE COUNTY, FL (661100) A File: DAYTONABEACH.TMY) ..Lighting Controls Compliance �Acronym Ashrae Description Area.- - No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance P OZo1Sp1 36 Common Activity Areas - 1,639 1 12 2 PASSES Computer/Office Equipment PASSES Pr 1 ject: SSI 2133 Ti le: SSI2733 e: Office (Business) Lo ation: FORT PIERCE, ST LUCIE COUNTY, FL (661100) A File: DAYTONABEACH.TMY) System .Report Compliance Pr Syl° System 1 Constant Volume Packaged No. of Units System 1 omponent Category Capacity Design- . Eff Design. IPLV Comp- i Eff Criteria 1PLV Criteria -liance C 'poling System Air Cooled 65000 to 135000 9.70 _ . " 8.90 8.33 8.30 PASSES Btu/h Cooling Capacity . A' Handling Air Handler (Supply) - 0.80 0.80 PASSES Sy 'Item -Supply Constant Volume , PASSES I A l/05 EnergyGauge F1aCom FLCCSB v1.22 4 dill, 1 Plant Compliance I Description Installed Size Design Min Design Min Category Comp No Eff Eff' IPLV IPLV liance I . None joject: SSI2733. ide: SSI2733 �pe: Office.(Business) m cation: FORT PIERCE,. ST LUCIE COUNTY, FL (661100) A File: DAYTONABEACH.TMY) Water Heater Compliance escription Type Category Design . Min Design Max Comp Eff Eff Loss Loss liance l ater Heater 3 _ .. -- Storage Water Heater - <=120 [gal] & <= 0.93 0.92 PASSES Electric 12 [kW] I I - PASSES Piping System Compliance ategory Pipe Dia . Is Operating Ins Cond, Ins Req Ins Compliance [inches],, Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] .SF.F] II . ., None 6/11A r EnergyGauge F1aCom FLCCSB v1.22 5 6/11 'roject: SSI2733 Title: SSI2733 Iype: Office (Business) ,ocation: FORT PIERCE, ST LUCIE COUNTY, Other Required Compliance Category Section, Requirement (write N/A in bog if not applicable) Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation a 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Electrical 413.1 Metering criteria have been met Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 4.04.1 IR-19 for Roof Deck with supply plenutns'beneath it Report 101 Input Report Print -Out from EnergyGauge F1aCom attached? A EnergyGauge F1aCom FLCCSB v1.22 Check