HomeMy WebLinkAboutSELF ADHERING MODIFIED BITUMENProduct
Information
Compliances
FLINTLASTICO SA
Self -Adhering SBS Modified Bitumen .Mid 'Ply,and Cap Sheet acid glu
SBS Modified Bitumen Base Sheet for SA Roof:Systems: tieC�qt� ,
Flintlastic SA roofing membrane is a premium, self -adhering SBS modified bitumen roll roofing
material suitable for use in accordance with CertainTeed specifications.for most low slope roof
system applications. Refer to the CertainTeed Commercial Roof Systems Specification Manual
for complete self adhered roof system'specifications and application requirements.
The Flintlastic SA line of products is more than a single membrane, it is a complete roof
system designed for base and cap or base, mid -ply and cap roof system configurations.
Use of Flintlastic SA Base permits complete mechanical attachment to nailable substrates,
preserving the integrity of the substrate for future tear -offs -and adding additional waterproofing
performance capabilities to the overall system. For larger industrial/institutional applications,
Flintlastic SA Base, Mid Ply and Capin combination represent a premium roof system capable
of meeting the performance criteria of a larger roof. Use of Flintlastic SA Base also.adds to the
fire resistance of the roof system, enabling UL Listing,of the roof system.
When using self -adhering roofing products, particular attention must be paid to storage and
handling, deck preparation, slope and drainage, and application requirements to assure a
successful installation and long-term performance.
Flintlastic SA roofing membranes are manufactured on state of the art, dedicated roofing lines
specifically designed for the production of modified bitumen roofing membrane, and meet or
exceed the following ASTM standards:
ASTM Standard
Flintlastic SA Base D 4601, Type 11
Flintlastic SA Mid. Ply • D 6164 •V/
Flintlastic SA Cap 'D 6164
n urldercd �A'
L u�•hturs
Refer to the current UL Roof Systems Directo , or UL's web site, www.uLcomA'S�a ;
rim Exomnre a,•�y
for the most current information on UL listi g for Flintlastic SA Products. 62P3
Flinflastic-SA Base
'Flintlastic SA Mid Ply
Flintlastic SA Cap Sheet:
F1intFlashrm SA .
Roll'Dimensions
66'6" x 39-3/8"
33'11" x 39-3/8'
33'11" x 39-3/8'
33'11" x 13-1/8' (or 9-310
Thickness
1,5 mm
3.0 mm
4.0 mm
3.0 mm
Weight
84• Ibs
68 Ibs
97 ibs
22.5 Ibs (or 17 Ibs)
Coverage
2 Squares
1•Square
1 Square
1/3 Square (or 1/4 Square)
Top1arface
Permanent Film
-Permanent Film
Mineral -Variety of Colors
Permanent Film
*ttom Surface
Sand
Removable Release Film
Removable Release Film
Removable Release Film
.Reiritoreement
Fiberglass Mat
Polyester/Fiberglass
Scrim Combination, Mat
Polyester/Fiberglass
Scrim Combination Mat
Polyester/Fiberglass
Scrim Combination Mat
Tensrle,(lrn)
65/40 (MD/CD) 80/60 (MD/CD), 80/55 (MD/CD)
80/60 (MD/CD)
Elorigatrom(%),
6/5 (MD/CD) 50/55 (MD/CD): 50155 (MD/CD)
50155 (MD/CD) .
Packaging
"Palletized, Bands " Individual Cartons' Individual Cartons
Individual Cartons,
_
20 rolls per pallet-, 20,rolls perpailet' 20 rolls per pallet
3 rolls per carton (or 4)
60 rolls per pallet (or 80)
installation
Refer to the CertainTeed Commercial Roof Systems Specification Manual for complete product
installation details and requirements, Below is a general guideline:
Deck Preparation
CertainTeed rer d,; the use of Flintlastic SA Base in -conjunction with all self -adhering
membrane. roof .,ns, Non-nailable roof decks may receive direct application of
r � �
Installation Flintlastic SA Mid -Ply followed by Flintlastic SA Cap provided the deck is thoroughly primed using Flintlastic SA
(cont'd) Primer. It should be noted without the use of a base sheet the membrane may be difficult to remove if removal
is ever warranted, and certain UL and FM listings for the product may not apply.
Flintlastic SA Base
Nailable Substrates: Use standard nailing patterns and CT approved fasteners for attachment to nailable
decks. Nail base sheet every 9' o.c. on side laps and every 18' on center in 2 staggered rows in the field
of the sheet. Permanent top surface film is left in place.
Non-Nallable Substrates: Prime non-nailable substrates such as concrete using FlintPrimeTM SA at the rate of .20
—.25 gals/square. Allow primer to dry, maximum 4 hours. Apply base sheet using hot asphalt at the rate speci-
fied by CertainTeed. Insulation if used must be suitable to receive hot asphalt application such as FlintBoardT"l
ISO Plus. Overlap base sheet sidelaps 3' and endlaps 4". Always start membrane application at the low point of
the roof and install all plies so that no laps are against the flow of water. Offset endlaps minimum 36'.
Flintlastic SA Mid Ply
.Apply to Flintlastic SA Base or suitable primed substrate overlapping sidelaps 3"and endlaps 6'. Work with
.lengths of Flintlastic SA Mid Ply'appropriate,for proper handling. Position. and align cut, lengths of Mid Ply,
staggering laps from the underlying base a minimum of 18' and offsetting endlaps 36 Once positioned, fold
back the membrane halfway lengthwise and remove the release film, then ease back into place. Or, lift,the end
of the membrane and pull the split release film out as you walk the length of the membrane. Cut opposing
corners of endlaps diagonally to minimize "T" seam joints and seal using FlintOond SBS Modified Bitumen
Adhesive, trowel or caulk grade. Also apply a bead of FlintBond at side and endlaps. Use a heavy, weighted
roller to smooth and secure the membrane. Permanent top surface film is left in place.
Flintlastic SA Cap
,Applyto Flintlastic SA Base and/or'Flintlastic SA Mid Ply working,with lengths of membrane appropriate for
proper handling and'thesame installation procedure as described for Flintlastic SA Mid Ply. Overlap. sidelaps
4' and•endlaps 6'. Selvage edge with release strip is provided on Flintlastic SA Cap; position roli'with selvage
'edge at the high side'of the roof. Once the first cap sheet membrane length is in place remove the top,aideIap
-release-film before overlapping.the second length of Flintlastic-SA Cap Sheet. Stagger sidelaps of.Fiintlastic SA'
Cap a minimum of 18' from those of the underlying Flintlastic SA Mid Ply, and be. certain endlaps are also.
staggered minimum 36'. At endlaps (or,any overlap onto mineral surface), use trowel grade Flint8ond Modified
Bitumen Adhesive uniformly in a 1/16"to 1/8" layer wherever an overlap exists to ensure'an adequate bond.
Cut opposing corners of endlaps diagonally, to avoid "T" seam joints. Use a heavy, weighted roller to smooth
and secure the membranes .
Verticals and Flashing Details
Vertical transitions and flashing details require a minimum two-ply detail using Flintlastic SA Mid Ply and
Flintlastic SA Cap, secured with Flintlastic Modified Bitumen Adhesive, trowel grade. FlintFlashTM SA pre-cut
flashing rolls can also be used in conjunction with flashing details.
WaCr'antleS . CertainTeed offers a limited material Roof Membrane Warranty on. Flintlastic SA roof membrane. Contact your
nearest CertainTeed office for additional information and requirements.
Technical CertainTeed provides technical assistance in the design, selection, specification and application guidelines
Assistance for all CertainTeed Commercial Systems. Architectural and field representatives are available for consultation
within each region.
Precautions Do not attempt application if ice, snow, moisture or dew are present. Surface to be bonded to must be clean,
dry and free from any dust or deterrent to adhesion. Ambient temperature must be 50OF or above. Do not
attempt installation on roofs without adequate slope and drainage.
r. ,
l $topgE 'and.• SA rolls must be stored above ground,, indoors, protected from the elements. Rolls that are improperly stored or
Handling have been on hand for -prolonged periods of time may lose their tack. Do not attempt to install rolls that do not
I exhibit an adequate bond.
CertainTeedfif
COMMERCIAL ROOFlNG SYSTEMS
www.certainteed.com
0 2002 Cerra,n7eed Corporaean
750 East Swedestord Rd. West Region
P.O. Box 860
6,100 Stevenson Blvd.
Valley Forge, PA 19482
nont, CA 94538
(610) 341-7000
955.0811
Sales Support Group
.0-3347 fax
(800) 233.8990
South Region
North Region
5525 MacArthur Blvd.
Rlverbridge Industrial Center
Suite 900
800 W, Front Street
Irving, TX 75038
Chester, PA 19013
(800) 333-ROOF (7663)
(866) 297-ROOF (7663)
(972) 580.5645 fax
(610) 874.6170 fax