Loading...
HomeMy WebLinkAboutD O H - SEWAGE TREATMENT AND DISPOSAL SYSTEM - FINAL APPROVAL1 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE' TREATMENT AND DISP_OSAL_S-YSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL U-NI, d !l AGENTTGer ADDRESS: 205 N APPLICATION 9:AP1361671 PERMIT '#:56-SF-1873214 .DOCUMENT #:F11263202 DATE.'PAID:08/2.7/2018 FEE' PAID:515.00 RECEIPT #:56-PID-3672653 1 LOT: 17 & 18 BLOCK: 5 �j'� Quci; ST. Lucie County, Permitting I' suBDlvtsloN: Wilbuwe ID# s 2408=603-0056-000-6 lil CHECKED [X] ITEMS,ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. (TANK INSTALLATION SETBACKS [ ] �[O1] TANK SIZE [1] 1090.00 [2] 483.00 [ ] [271 SURFACE WATER FT [ ] 1I[02] TANK•'MA TERIAL Polypropylene [ ] [28,1 DITCHES FT [ ] II[03.] OUTLET DEVICE [ ] [2'9] PRIVATE WELLS FT [ ] I[04] MULTI -CHAMBERED [ 'Y N ] [ ] [30] PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylo.k PL-68 [ ] [31.] IRRIGATION WELLS 90 FT ] ![06] LEGEND 1',. 70-143'-11DC3 2., 70-143-54SC4_ [ ]: [321 POTABLE WATER .40 FT [ ] [.07], WATERTIGHT [ ], [331. BUILDING FOUNDATIONS 5 FT [ ] t08] LEVEL [ ] '[34], PROPERTY LINES 8 FT [, ] ,09]. DEPTH .TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] 40] AREA [1] 339.6 [21 SQFT [ ] [36], DRAINFIELD COVER [ ] 111' .DISTRIBUTION: BOX HEADER X [ ] (37]' SHOULDERS [ ] �12] NUMBER OF DRAINLINES t. 5.00 2. [ ] [38] SLOPES [ ] �431 DRAINLINE SEPARATION [ ] [39]. STABILIZATION [ ] [i14] DRAINLINE SLOPE [ ] I15•] DEPTH OF. COVER ADDITIONAL INFORMATION [ ] 9161 ELEVATION [ ABOVE / BELOW ]BM 7.00 [ ] [40] UNOBSTRUCTED AREA ] [ 7] SYSTEM ;LOCATION [ ] [,411 STORMWATER RUNOFF [ ] [181 DOSING 'PUMPS 1.00 [ ] [42] ALARMS„ [ ] 9] AGGREGATE.SIZE [ ] (43] MAINTENANCE AGREEMENT' [ ] [ O] AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA ]. [dill] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN Fj�ILL / EXCAVATION MATERIAL [ ] [46] .FINAL SITE GRADING [ ] [PI��2] FILL AMOUNT [ ] [471 CONTRACTOR • MICHAEL W STUHR (ASHTO [ ] [23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Qliick4 Plus EQ36 LP[ ] [ 4] EXCAVATION DEPTH- ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK.PUMPED [ ] [2I6] REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments; Comments are on page 2. ICI CONSTRUCDION I APPROVED /FQ St; Lucie CHD DATE: 01/30/2019 1 DISAPPROVED 1 CEnvI mental'Speclallst 11 Brian J Ingram (ENVIRONMENTAL HEALTH) FINAL SYS �EM [ 'APPROVED / DISAPPROVED 1: _ St. Lucie. CHD' DATE:. 04/15/201.9' me toSpecialis H5-nterA Collier (Florida Department of Hea (Explanation of Violations on followipg.page) DH 4016, 8/09 (Obsoletes all Previous editions ,which,may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 IIEH Database v 1.0.1 AP1361671 EID1873214 APPLICATION -#:,AP136'1671 STATE' OF FLORIDA PERMIT #:56­SF-1873214 DEPARTMENT OF HEALTH 'DOCUMENT *:F1 1263202 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DATE PAID:08/27/201.8 CONSTRUCTION INSPECTION AND FINAL APPROVAL: WEI FEE, PAID :515.00,--. RECEIPT #:-56-PID-8672653 Violation on Number Comment Commenis' Final inIpection approve.,. ErIndiled to. building department .and contractor, The sysi m is sized for ,2 bedrooms ,with :a maximum imum occupancy of 4,persons (2 per bedroom), for a total estimated flow. of 200 gpd. New ST 'filter,, DT, li4ertyI/3 hp: pump, and 5x6,lohg DF installed., 339.6 SOF DF INSTALLED As A BED. No viola i ions, system ok to: cove r.,.'Con tractor notified by phone. Needs final Inspection for mound system; alarm check,. and.final site. grad DH 4016,111 08/09 (Obsoletes.,all previous editioris., which -may not be used) Incorporated; 150-6.00j, FAC Page 2 of 3 . '111 �i EH Database v 1'.0.1, AP1361671 EID1873214