Loading...
HomeMy WebLinkAboutPRODUCT REPORT - 5V CRIMPMANNED 2160 SW Poma Drive 0V Palm City, FL 34990 Lucie County (17,2)872-8034 Com' liant with Florida Building Code 2017 (6t' ed.) Com liant with Florida Product Approval Rule # 61G20-3 Corn liant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fasteer 1(Method 1 Attachment): #9 x 1-2/2" Hex -Washer Head wood screw* to penetrate 3/16'fmin. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requi iements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Under, ayment: To be compliant with FBC Sec. Chart 1507.1.1 Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above Install betails: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE*_ _ -86 PSF -93.5 PSF -101 PSF -228 PSF_ ROWS ACING 16" o.c. 16" o.c. 8" o.c. 6" o.c. FASTENER SPACING (ALONG. Panel width) 12" o.c. 12" o.c. 12" o.c. 12" o.c. FASTENER SIZE #9 #10 #10 #10 iefere2ce Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test Report D05893.01-450-18 Test Report F3366.01-450-18 05/02/14 12/10/15 I TAS 12 -03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-IFr.... *Design pressure margin of safety 2.1 Locke E under 1 Locke E report. tden, P.E. does not have, not will acquire a financial .int 1. e � cg rhimjfwfacturing or distributing products y evaluation. - a +den, P.E. is not owned, operated, or controlled by a& cosAparlVornhila baturer, or distributing products under this . ST;t7 e L� 4 • FL17022.1 5V Cry, ra (26GA Steel), 24" Wide Roof P� _,�I -Details 1. Underl yment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Produces are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engine �i ring analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire cla sification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Suppo framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structu lal Loading. 7. This reportp does not imply warranty, installation, recommended product use outside of this report. a2" or greater Plywood, or Wood plank 24" ur In nn n n OFMONAL s7RIATIOM Parcel Profile Nominal 12" Nominal 12" O.C. O.C. Fasten ff x 1-1/2" Min. or #10 x 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or Wood plank