Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY - 8-3-18FORM 1405-2017 FLO.IDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Flolida Department of Business and Professional Regulation - Residential Performance Method Project ame: DIANNE W MERRITT ADDITION Builder Name: ?rANN Street: 1202 COUNTRY GARDENS LANE Permit Office: ST. LUCIE COUNTY �� City, Sta Zip: FT. PEIRCE , FL, Permit Number: c,, }" Owner: ram. DIANNE W MERRITT Jurisdiction: ;:b > ude oun Design cation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New co'I struction or existing Addition 9. Wall Types (384.0 sqft.) Insulation Area 2. Single mily or multiple family Single-family a. Frame - Wood, Exterior R=13.0 384.00 ft2 3. Numbe of units, if multiple family 1 b. NIA R= ft2 c. N/A R= ft2 4. Numbe of Bedrooms(Bedrms In Addition) 0(0) d. N/A R= ft2 5. Is this worst case? No 10. Ceiling Types (288.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 288.00 ft2 6. Conditioned floor area above grade (ft2) 288 b. N/A R= ft2 Conditi Ined floor area below grade (ft2) 0 c. N/A �= ft2 11. Ducts R ft2 7. Windo s(24.0 sqft.) Description Area a. U-F ctor: Dbl, U=0.65 24.00 ft2 SH.C: SHGC=0.25 b. U-F ctor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SH C: a. Central Unit 9.0 SEER:24.50 c. U-F ' ctor: N/A ft2 SH IC: 13. Heating systems kBtu/hr Efficiency d. U-F ctor: N/A ft2 a. Electric Heat Pump 9.0 HSPF:12.50 SH,C: Area lighted Average Overhang Depth: 2.000 ft. Area I ighted Average SHGC: 0.250 14. Hot water systems - None required S. Floor Types (288.0 sqft.) Insulation Area �''On-Grade a' Cap: NIA a. Sla Edge Insulation R=0.0 288.00 ft2 b. Conservation features EF: 0.000 b. N/A R= ft2 c. NIA R= ft2 15. Credits Pstat Glass/ Ior Area: 0.083 Total Proposed Modified Loads: 8.02 PSS 1�0 Total Baseline Loads: 12.64. r1 I hereby ,certify that the plans and specifications covered by Review of the plans and THE STgT this calc lation are in compliance with the Florida Energy specifications covered by this ti+�� _ .0�, Code. calculation indicates compliance with the Florida Energy Code. ti rur„'�.; PREPAIR Dtop Y: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I herebyicertify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'OD WE OWN E AGENT: BUILDING OFFICIAL: DATE: DATE: - COM6 1liance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certif ed factory -sealed in accordance with R403.3.2.1. - Comp lance requires an Air Barrier and Insulation Inspection Checklist in accord 2.4.1.1 and this project requires an envelo a leakage test report with envelope leakage no greater than 7.00 ACH50 (R 02.4.1.2RECEIVED ---FILE SEP 2 5 2018 ntys6,170 8I3/20 810:24 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4 i ' I FORM RA 9017 INPIJL.-II ARY CHECKLIST REPORT -PROJECT Title: Building Owner N # of Uni Builder Permit O Jurisdicti Family T IIing: Comme I pe: ; 'me: N me: ice: n: pe: DIANNE W MERRITT ADDIT Bedrooms: 0 User Conditioned Area: 288 DIANNE W MERRITT Total Stories: 1 1 Worst Case: No Rotate Angle: 0 ST. LUCIE COUNTY Cross Ventilation: Whole House Fan: Single-family Addition Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 1202 COUNTRY GARD County: St. Lucie City, State, Zip: FT. PEIRCE , FL, CLIMATE 1/ Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low - BLOCKS Numb ir Name Area Volume 1 Blockl 288 2304 SPACES Numb' r Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 ;I ADDITION 288 2304 Yes 1 1 Yes Yes Yes FLOORS 11 # Floor Type Space Perimeter• R-Value Area Tile Wood Carpet. . 1 Slab -On -Grade Edge Insulatio ADDITION 72 ft 0 288 ft= _ _ 0 0. 1 f ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) I 1 Hip Composition shingles 312 ft' 0 ft2 Medium 0.6 No 0.9 No 0.6000 .22.6 ATTIC V # Type Ventilation Vent Ratio-(1 in) Area RBS IRCC 1 Full attic Vented 300 288 ft' N N CEILING # Ceiling Type Space _ R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) ADDITION 30 Blown 288 ftz 0.11 Wood 8 10:24 AM EnergyGauge® USA Section R405.4.:1 Compliant Software Page 2 of 4 FORM R4 5-2017 INPWT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 —2 3 N E S Exterior Frame - Wood Exterior Frame - Wood Exterior Frame - Wood ADDITION 13 12 8 96.0 ft2 ADDITION 13 24 8 192.0 ft2 ADDITION 13 12 8 96.0 ft2 0 0 0 0.023 0.6 0.023 0.6 0.623 0.5' 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Ornt ID Frame Panes Overhang NFRC U-Factor SHGC Imp Area Depth Separation Int Shade" Screening S 3 Metal Low-E,Double Yes 0.65 0.25 N. 12.0 ft2 2 ft 0 in S. 3 Metal Low-E Double Yes 0.65 .0.25 N 12.0 ft2 2 ft 0 in 1 ft4 in 1 ft 4 in Drapes/blinds Drapes/blinds None None INFILTRATION # S, pe Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Whoi house Proposed ACH(50) .000356 268.8 14.76 27.75 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/Suppleme None HSPF:12.5 9.kBtu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Efficiency' Capacity Air Flow SHR Block Ducts i 1 Central Unit/Supplemental for None SEER: 24.5 9 kBtu/hr 270 cfm 0.8 1 Ductless SOLAR HOT WATER SYSTEM ji� FSEC Cert # Company Name System Model # Collector Model # Collector Area Storage volume FEF i ft2 810:24 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R4 5-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Program le Thermostat: Y Ceiling Fans: Cooling Jan Feb Mar Apr May X Jun Jul rX Aug Sep Oct Nov [�] Dec Heating Jan Feb Mar I Apr May I I Jun Jul ri ] Aug Sep ri 1Xi Oct Id X� Jun Jul [[[[ l Aug L Sep Nov t l DecVenting Thermost1,,�,pe Schedule: HERS 2006 Reference Hours Schedule 1 2 3 4 5 6 7 8 9 10 11 12 Cooling ) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling H) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating ( D) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating ( EH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 711 MASS mi. ss Type Area Thickness Furniture Fraction, Space D 6ult 8 Ibs/s .ft. 0 ftz Oft 0.3 ADDITION Name: Rating Compant: 10:24 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 4 2017 - AIR BARRIER AND INSULw i-ION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Proje� I t Name: DIANNE W MERRITT ADDITION Builder Name: Stre 1202 COUNTRY GARDENS LANE Permit Office: ST. LUCIE COUNTY City, tate, Zip: FT. PEIRCE , FL, Permit Number: Y Own r: DIANNE W MERRITT Jurisdiction: i Desi n Location: FL, Fort Pierce 'I v COM , ONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA Genera+ll A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall require ents The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling ttic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceijin (soffit y g the insulation and an gaps in the air barrier shall be sealed. y g p air shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windo�js, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors ;I The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (includ above•ggarage ng insulation. maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation and ce,, tilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl pace walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation i a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shaftjl penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be out to fit, or narrow Narro cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Gara a separation Air sealing shall be provided between the garage and conditioned spac as. Rece �ed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plum 'ing and wiring Batt insulation shall be out neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Sho er/tub on exterior The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall wall tubs shall separate them from the showers and tubs. be insulated. Electfical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVA register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprin llers sealed In a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids W=pn fire sprinkler cover niates and walls or ceilinga- P. Is vvlllvll, llla1J Ivsl VI IWU Walla assail WO III al.Wluallwa Mill 111C pluvl.`ilullb VI B. %a-4uu. 8/312 '�i8 10:24 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 DISPLAY CARD 2. 3. 7 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 63 The lower the Energy Performance Index, the more efficient the home. home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R e-family or multiple -family 2. Single-family b) Return ducts R c) AHU location l�lo. of units (if multiple -family) 3. 1 umber of bedrooms 4. 0 Is this a worst case? (yes/no) 5. No Conditioned floor area (sq. ft.) 6. 288 Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 24.0 Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c. Wall type and insulation: A. Exterior: 1. Wood frame (insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 13.0 10A2. 13. Cooling system: Capacity 9.0 a) Split system SEER b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 24.5 14. Heating system: Capacity 9.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 12.50 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 10131. 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy aving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL isplay card will be completed based on installed code compliant features. Signature: Date: ,ddress of New Home: 1202 COUNTRY GARDENS LANE City/FL Zip: FT. PEIRCE, FL 8 10:24:34 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FSC 6th Edition (2017) Compliant Software Page 1 of 1