HomeMy WebLinkAboutPRODUCT APPROVAL - METAL ROOFBCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search
IFlo da
Product Approval
' .FUSER: Public User
J � Si4NNE® Product Approval Menu > Product or Application Search > Application Lis[ > Application Detail
a �U
e ; FL # FL11651-R3 t Lucre County v
tS
Application Type Revision
Code Version 2017
Application Status Approved
i
Comments
Archived %?
Product Manufacturer Gulf Coast Supply & Manufacturing, LLC.
Address/Phone/Email 4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352)498-0778
info@gulfcoastsupply.com
Authorized Signature Ray Bowen
info@gulfcoastsupply.com
Technical Representative David Eng
Address/Phone/Email 14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352)498-0778
info@gulfcoastsupply.com
I
Quality Assurance Representative David Eng
Address/Phone/Email 14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352)498-0778
david.eng@gulfcoastsupply.com
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
I
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Daniel S. Kuhn
the Evaluation Report
Florida License PE-75519
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden
IJ Validation Checklist - Hardcopy Received
Certificate of Independence FL11651 R3 COI Cert of Independence 2017-10-09.pdf
i
Referenced Standard and Year (of Standard) Standard Year
FM 4471 1992
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL1897 ". 2012
File Copy
UL 580
2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
10/10/2017
Date Validated
1O/12/2017
Date Pending FBC Approval
10/17/2017
Date Approved
12/12/2017
Summary of Products
Go to Page =
FL # IModel, Number or Name
11651.1 0.032" Aluminum 5V Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -108.5 psf @ 12" o.c. Install per manufacturers
details. Not for use in HVHZ Zones.
4) 0 Page l/ 2 0 0
Description
Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32"
Plywood
Installation Instructions
FL11651 R3 II FL11651 1 R3 Metal Roof Panel Detail-
sioned.od
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 1 R3 0325vCrimo 15-
32Plywood NonHVHZ-sioned.odf
Created by Independent Third Party: Yes
11651.2
0.032" Aluminum Gulf Lok
Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over
15/32" Plywood
Limit se
Installation Instructions
proved for use in HVHZ: No
FL11651 R3 II FL11651 2 R3 Metal Roof Panel Detail -
signed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF
Created by Independent Third Party: Yes
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf
Evaluation Reports
@ 5 3/16" o.c. fastener spacing. Install per manufacturers
FL11651 R3 AE FL11651 2 R3 032GulfLok 16 15-
32Plvwood NonHVHZ-sianed.odf
details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.3 1 1" 24ga. Gulf Snap
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/--131.OPS
Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in HVHZ
Zones.
11651.4 1 1" 24ga. VersaLoc
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-138.5PSF
Other, -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in HVHZ
Zones.
11651.5 1 1" VersaLoc .032" Aluminum
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R3 II FL11651 3 R3 Metal Roof Panel Detail-
sioned.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 3 R3 1 24GulfSnao 17 15-
32Plvwood HVHZ-sioned.odf
Created by Independent Third Party: Yes
1" VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood
Installation Instructions
FL11651 R3 II FL11651 4 R3 Metal Roof Panel Detail-
sianed.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 4 R3 24VersaLoc SR 16.5 15-
32Plvwood HVHZ-signed.odf
Created by Independent Third Party: Yes
1" VersaLoc min .032" Aluminum over 15/32" Plywood
Installation Instructions
EL1.1.651_ R3 _ II FL11651 5 R3 Metal Roof Panel Detail-
sioned.odf
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-101.OPSF
Other: -63.3 psf @ 24" o.c. clip spacing. -101.0 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in HVHZ
Zones.
11651.6 1 1.5" 24ga. Gulf Snap
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.OPSF
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per
manufacturers detals. For use in HVHZ Zones.
11651.7 1 1.5" 24ga. VersaLoc
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-123.5PSF
Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. For use in
HVHZ Zones.
11651.8 12" 24ga. MegaLoc
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. Not for use
in HVHZ Zones.
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 5 R3 iin 032VersaLoc
SR 16 15-32Plvwood HVHZ-sioned.odf
Created by Independent Third Party: Yes
1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32"
Plywood
Installation Instructions
FL11651 R3 II FL11651 6 R3 Metal Roof Panel Detail-
sioned.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 6 R3 1.5 24GulfSnao 16 IS-
32Plvwood HVHZ-sianed.odf
Created by Independent Third Party: Yes
1.5" VersaLoc min 24ga. 16" wide Roof Panel over 15/32"
Plywood
Installation Instructions
FL11651 R3 II FL11651 7 R3 Metal Roof Panel Detail-
sioned.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 16 15-
32Plvwood HVHZ-sioned.odf
Created by Independent Third Party: Yes
Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32"
Plywood
Installation Instructions
FL11651 R3 II FL11651 8 R3 Metal Roof Panel Detail-
sianed.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 8 R3 24VersaLoc 18 15-
32Plvwood NonHVHZ-sianed.odf
Created by Independent Third Party: Yes
11651.9
24 Ga. Gulf Lok
Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail -
sioned.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-96.7PSF
Created by Independent Third Party: Yes
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76 psf
Evaluation Reports
@ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8" fastener
FL11651 R3 AE FL11651 9 R3 24GulfLok 16 15-
32Plvwood NonHVHZ-sioned.odf
spacing. -161 psf @ 5-1/8" fastener spacing. Install per
manufacturers details. Not for use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.10
24 Ga. Gulf Seam
Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood
Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 10 R3 Metal Roof Panel Detail -
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 7SS19
Design Pressure: +N/A/-93.5PSF
Created by Independent Third Party: Yes
Other: -93.5 psf @ 18" o.c. Install per manufacturers details.
Evaluation Reports
Not for use in HVHZ Zones.
FL11651 R3 AE FL11651 10 R3 24GulfSeam 16 1x4 15-
32Plvwood NonHVHZ-sianed.odf
Created by Independent Third Party: Yes
11651.11 124 Ga. Gulf Seam
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.SPSF
Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. Not for use
in HVHZ Zones.
Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel
over 15/32" Plywood
Installation Instructions
FL11651 R3 II FL11651 11 R3 Metal Roof Panel Detail-
sianed.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 11 R3 24GulfSeam 18 15-
32Plvwood Non HVHZ-sianed.odf
Created by Independent Third Party: Yes
11651.12 126 Ga. 5V Crimp
Min 26 Ga. 5V Crimp Roof Panel over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.5PSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @
6" o.c. fastener spacing. Install per manufacturers details. For
use in HVHZ Zones.
Installation Instructions
FL11651 R3 II FL11651 12 R3 Metal Roof Panel Detail-
sianed.od
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 12 R3 265vCrimo 15-
32Plvwood HVHZ-sioned.odf
Created by Independent Third Party: Yes
111651.13 126 Ga. 5V Crimp I Min 26 Ga. 5V Crimp over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131.PSF
Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @
16" o.c. fastener pattern. Install per manufacturers details.
Not for use in HVHZ Zones.
Installation Instructions
FL11651 R3 II FL11651 13 R3 Metal Roof Panel Detail-
sianed.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 13 R3 265vCrimo 15-
32Plvwood NonHVHZ-sioned.odf
Created by Independent Third Party: Yes
11651.14
26 Ga. 5V Crimp
Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 14 R3 Metal Roof Panel Detail -
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-156.5PSF
Created by Independent Third Party: Yes
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @
Evaluation Reports
6" o.c. fastener spacing. Install per manufacturers details. For
FL11651 R3 AE FL11651 14 R3 265vCrimo 1x4 15-
32Plvwood NonHVHZ-sianed.odf
use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.15
26 Ga. Gulf Lok
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 II FL11651 15 R3 Metal Roof Panel Detail -
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-161.OPSF
Created by Independent Third Party: Yes
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75 psf
Evaluation Reports
@ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener spacing.
FL11651 R3 AE FL11651 15 R3 26GulfLok 16 15-
32Plvwood HVHZ-sioned.odf
Install per manufacturers details. For use in HVHZ Zones.
Created by Independent Third Party: Yes
11651.16
26 Ga. Gulf Lok
Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 16 R3 Metal Roof Panel Detail -
sioned.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-63.5PSF
Created by Independent Third Party: Yes
Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75 psf
Evaluation Reports
@ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener
FL11651 R3 AE FL11651 16 R3 26GulfLok 16 15-
32Plvwood NonHVHZ-sioned.odf
spacing. Install per manufacturers details. Not for use in HVHZ
Zones.
Created by Independent Third Party: Yes
11651.17
26 Ga. GulfPBR
Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 17 R3 Metal Roof Panel Detail -
sioned.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Created by Independent Third Party: Yes
Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf @
Evaluation Reports
12" o.c. fastener pattern. Install per manufacturer details. Not
FL11651 R3 AE FL11651 17 R3 26GulfPBR 15-
for use in HVHZ
32Plvwood NonHVHZ-sianed.odf
Created by Independent Third Party: Yes
11651.18 126 Ga. GulfPBR
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure, +N/A/-151.7PSF
Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf @
12" fastener spacing. Install per manufacturer's details. For
use in HVHZ Zones
Min 26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over
15/32" Plywood
Installation Instructions _
FL11651 R3 II FL11651 18 R3 Metal Roof Panel Detail-
sianed.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 18 R3 26GulfPBR 1x4 15-
132Plvwood HVHZ-sianed.Ddf
Created by Independent Third Party: Yes
11651.19
26 Ga. GulfPBR
Min 26 Ga. GulfPBR over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 II FL11651 19 R3 Metal Roof Panel Detail -
sioned.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-154.7PSF
Created by Independent Third Party: Yes
Other: -60.5 psf @ 24" D.C. fastener spacing.-154.75 psf @
Evaluation Reports
12" o.c. fastener spacing. Install per manufacturer's details.
FL11651 R3 AE FL11651 19 R3 26GulfPBR 15-
For use in HVHZ Zones.
32Plvwood HVHZ-sioned.Ddf
Created by Independent Third Party: Yes
11651.20
26 Ga. GulfPBR
Min 26 Ga. GulfPBR over 1x4 Wood Purlins over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detail -
sioned.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-151.7PSF
Created by Independent Third Party: Yes
Other: -94.25 psf @ 24" D.C. fastener spacing.-151.75 psf @
Evaluation Reports
12" fastener spacing. Install per manufacturer's details. Not for
FL11651 R3 AE FL11651 20 R3 26GulfPBR 1x4 15-
32Plvwood NonHVHZ-sioned.Ddf
use in HVHZ Zones
Created by Independent Third Party: Yes
Go to Page = 0
t3ao9 13ext
0 4) Page l/ 2 4 0
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
® twheckN
Credit•
Safe