Loading...
HomeMy WebLinkAboutWIND PRESSURE CHARTf 9 f _ _ BASIC WIND SPEED = 170 mph RISK CATEGORY I/ BUILDINGS RESIDENTIAL--AP-ARTMEN-T-BUILDINGS-8c COMME-R�-IAL-BOIL-DINGS-(RETAIL,-WI-IOL-ESAtE) CONCEh. CONCEALED FASTENERSHEENi . METh6 ARE THE RESPONSIBILITY OF - - - - -- - - - -- CONTRA6CONTRACMR OF RECORD RECEIVED . Lucie County, Permitting PEAK ROOF Lrx LESS THAN 7'-9" L- GREATER OR EQUAL THAN 7'-9" AND LESS THAN 12'-3" Lr: GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE 'If-UL7I A." -ULTLpATE--A-SD. ULTIMATE - A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. 0' - 15, 76.4 45.8 102.4 61.4 73.0 43.8 95.5 57.3 68.5 41.1 86.4 51.8 > 15'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 79.8 47.9 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77.3 46.4 97.4 58.4 > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 40'-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 106.5 63.9 > 50'-60' 97.3 58.4 130.3 1 78.2 92.9 55.7 121.5 72.9 87.2 52.3 109.9 65.9 BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS A CLADDING (P S F j FOR ASCE 7- f 0 - PEAK ROOF HEIGHT O.MTER THAN 60 FEET BASIC WIND SPEED = 170 mph RISK CATEGORY lI BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF Lxr LESS THAN 12-3" Lxx GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 16Z7 100.E 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 151.9 91.1 > 80' - 90' 95.6 57.4 175.2 105.1 88.0 52.8 155.0 93.0 > 90' - 100' 97.3 58.4 178.4 107.4 89.7 53.8 157.9 94.7 > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 163.0 97.8 > 120' - 140' 103.2 61.9 189.2 113.5 95.1 571 167.4 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 97.3 58.4 171.3 102.8 (> 160' - 1801 107.8 64.7 y 197.6 ( 118.6 99.3 59.6 174.9 104.9 > 880''-zoo' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114. 1 68.5 209.2 125.5 105.2 63.1 185.1 111. 1 > 250' - 300' 117.8 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 300' - 350' 121.0 72.6 221.9 133. 1 111.5 66.9 196.3 117.8 > 350' - 400' 123.9 74.3 227.1 136.3 114.1 68.5 200.9 120.5 400' - 450' 126.4 75.8 231.8 139.1 116.5 69.9 205.1 123.1 > 450' - 500' 128.8 77.3 236.1 141.7 118.6 71.2 208.9 125.3 NOTES: 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT. 3.) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND A.S.D. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID /F ALTERED BY ANY MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE17AKE OFF SHEET, ETC.). '!,� .S7P� a.•hN ST. LUCIE CJUN'' i I nL'�ILDI` �+� ItENrIER'ED FOR L G UVIENED B DATE T MUST BE KEPT ON JOB PLANS AND 0 NO INSPECTION WILL BE MADE. O •°•p000Nst .000•°O0 06. Noe 44i �7 e 0 STAB ®F THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO -ANY CORRECTIONS -- -- REQUIRED -BY FIELD INSPECTORS THAT tAAY BE NECESSARY IN ORDER TO 'flYPLY WITH ALL APPLICABLE CODES. INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDMONS AND FOR ALL ROOF SLOPES. * * L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT. �F * PRODUCTS WHICH BEAR A MIAMI-DADE COUNTY OR A STATE OF FLORIDA APPROVAL P?00 f a� (Fl 1 NNF.D my _fit Luate ( our 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER COUNTIES rL E obe. TILUT TESTING & ENGINEERING COMPANY 6355 N.W. 36th. SL, Ste. 305, V/RGINIA GARDENS, R. 3316t Phone (305)871-1530 . Fox : (305)871-1531 EB-0006719 WALTER A TILLIT Jr. P.E. FLORIDA LTc..4 44167 ASCE 7-10 / WIND PRESSURE CHART STORM PANELS ACCORDIQh(AHAMA SHUTTERS *** I WIND PRESSURE CHART BASIC WIND SPEED = 170 mph EXPOSURE D, Kd = 0.85 DESCkMON 11D 15-188 L.C. DRAWN BY 08109117 DATE 17-194 DRAWING No SHEET 1 OF 1