Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
I -+ ;� rightsoft, Project Summary Date: Enure House By: QUICK CALCS, INC. j 317 ST. LUCIE LN.; FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCSOMOL.COM For: WYNNE DEVELOPMENT THE CfifLTON 299, FT. PIERCE, FL Notes: 1 Weather. Winter Design Conditions db 42 OF b 70 OF TD 28 OF Fort Pierce, FL, US li Heating Summary Structure 18188 Ducts 5654 Btuh Btuh entral vent (0.cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 I j Heatingg rea (ft2) 1474 Cooling� 1474 Volume (ft3) 12227 12227 Air changes/hour 0.45 0.23 quiv. AVF (cfm) 92 47 Heating Equipment Summary L e Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A" 030 AHRI ref 7914585 iii Efficiency 8.5 HSPF heating input output 34600 Btuh @ 470F Eating T"mperature ri 27 OF A tuaI air flow 1160 cfm Ak flow factor 0.049 cfm/Btuh Static pressure 0.50 in H2O � yea Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61. gr/lb Sensible Cooling Equipment Load Sizing Structure 17877 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipmenf sensible load 0.95 25093 Btuh Latent Cooling Equipment Load Sizing Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh (none)' Equipment latent load 5277 Btuh Equipment total load 30370 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A" 030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O space mermostat Load sensible heat ratio 0.83 Capacity balance point = 33 OF B "ckup: . Inbut = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations aDDroved bvACCA to meat all reniiiremPntc of Manual A Ath Fri u' r" wrightsoft` Right -Suite® Universal 2017 17.0.14 RSU08101 ACCK J!Wrightsoft HVACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N 2017-Apr-1017:14:53 Page 1 I - w ightsoft' Right--J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST. L}JCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS(cDAOL.COM 1 Room 2 E>;posed name wall Entire House 156.2 ft BEDROOM 3 Room height 8.3 ft d 52.0 ft 8.0 ft heat1cool 4 Room dimensions 1.0 x 329.0 ft 5 Room area 1473.5 ft2 329.0 ft2 TV Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2L-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 V�/ 1I 13AAocs 0:143 •-.ne `'ne 4.00 ' ': 255 - 479 442 1768 ' 1124 aD 80 320 -. 204 L-G .1Ac1om ': 1.270 35.56 .-70.43 38 0 1344 - ' :2662 0 0 �0 0 13A-4acs 0.143 se 4.00 2.55 128 83 331 210 0 0 . 0 0 plCp 1A-clom 1.270 se 35.56 34.77 24 48 848 829 0 0 0 0 11 11DO 0.390 se 10.92 11.31 22 22 236 244 0 0 0 0 W 13A-4ocs 0:143 s 4.00 2.55 34 34 136 86 0 0 ' -0 0 0.143 sw 4.00 2.55 360 353 1414 899 224 224 897 510 JL-L13AAocs LLLL----���l----GGGG IA-clom 1270 sw 35.56 42.91 7 11 247 298 0 0 0 0 11 13A-0ocs 0143 nw 4.00 2.55 290 217 867 551 .112 79.. 318, 202 1Ac1om, 1.270 n.w 35.56 45.24 ,. 33 0 1162 1478 : 33 ,' . 0 " 1162 1478 4A5-2oms. ` '0.770 ,:,nw 21;56. 27.54 41 . ' D ' 880 S 1124. 0 . 0: 0 0 P ;� 12C-0sw 0.091 2.55 1.28 192 192 489 246 0 0 0 .' 0 C .16A-30md 0:032 0.90 ; 232 1474. 1474 .1320 • 3419 329, .329 295 763 IF22A I tpl 0.989 - 27.69 0.00 1474 156 4325 0 329 52 1440 0 11 II {.: ', 6 c)AED m excursion 7841 1680 Envelope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 2 460 I, I Appliances/other 20M p S6b total (lines 6 to 13) 18188 17877 5341 4606 Les�,Jwdemalload . 0 0 0 Lessltransfer 0 0 0 0 0 Redistribution' 0 0 0 0 14 Subtotal 18188 17877 5341 4606 15 '•Dug,�Ioads. 31% 48% 5654 853 6 31% 48% 1660 2199 Tota�'room.load 23842 26413 7001 6805 Air required (cfm) 1160 1160 341 299 1 lid wrightsoft' Right -Suite@ Universal 2017 17.0.14 RSU08101 �� .I ,I rightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N 2017-Apr-10 17:14:53 Page 9 - -V frightsofV RighW@ Worksheet Job: - Entire House Date: By: QUICK CALCS, INC. 31.7 ST I UCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 loom name WIC M. BATH 2 ed wall 0 ft 8.0 ft 3 oom height 8.0 ft heat/cool 8.0 ft heat/cool 4 oom dimensions 7.0 x 9.0 ft 7.0 ' x 8.0 ft 5 oom area 63.0 ft2 56.0 ft2 yConstruction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2L.°F) (Btuh/ft2,) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 d 13A4ocs;_ 0143 ne` 4:'00 255 0 ,' 0 ,. ,.. 0 0. -_ 0 0 0 0 1Ac1orrr' :1 270 , ne 3556 70:43 .. 0 0 0 ..' 0 0 ;- . 0 0 13A-lots 0.143 se 4.00 2.55 0 A 0 0 0 0 0 0 1Ac1om 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 AM4ocs,. 0.143, s :00 4', 2.55` 0 0 0.. 0 0 6 '0: 0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 64 57 228 145 1Ac1om 1270 sw 35.56 42.91 0 0 0 0 7 5 247 298 1 13A46cs 0143 nw 4:00 2.55. 0 0 0 0 0 0 b 0 1Ac1om =: km <. 1 270 770 nw 35;56 21.56 45.24 27:54 .. 0 0 0 '. 0 . ` , . 0 :: .. 0-: _ : p : =0 0 0. P :4A5 _ 12C-0sw ,0 0.091 ,:,riw - 2.55 .: 1.28 0 . 0 -0. 0. .' , .0 0 p 0 : p 0 p: 0 0 0 CI , . 16A=30nid 0 032 .:,_ : .0.90' : .2 92 63 = 63 56 .. ' ..146 56-,,. ,: 56 ` .. . 50: 130. F 22A tpl, 0 989 . - 27.69 0.00 63 0 0 0 56 8 ., , 222 0 J. 6 c) D excursion _2 225 Bi relope loss/gain 56 145 747 798 12 a), Infiltration 0 0 140 38 b) Room ventilation 0 0 6 0 13 In emad gains: Occupants @ MO 0 0 0 0 Appliances/other 0 0 5 � total pines 6 to.13) 56 145 887 836 L Is external load Less transfer 0 0 0 0 0 0 0 0 Rc istribution 0 0 0 0 14 .. Su ', btotal . 56 145 887 836 1.5 • m ct loads 31 % 48% 18 69 31 % 48% 276 399 T' al room load, . Feguired'(ofm) . 744 .219 1162 1254 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. P. r.wrriglhtsoft- 2017-Apr-10 17:14:53 Right -Suite@ Universal 2017 17.0.14 RSU08101 Page'2 -Wrightsoft WVAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front, Door faces: N - - .'I�rightsoft' Right-M Worksheet Job: Entire House Date: �+ QUICK CALCS, INC. By. I� 317 ST.� IIUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS ,AOL.COM 1 t�oom name KRCHEN BATH 2 . )osed wall 0 ft 5.0 ft 3 Room height 8.0 ft heaticool 8.0 ft heat/cool 4 Boom dimensions 1.0 x 192.0 ft 9.0 x 5.0 ft 5 area 192.0 ftz 45.0 ftz JJDOnn T, Construction U-value Or HTM Area (ft-) Load Area (ftj Load number (Btuh/W °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 V�/'I 13A-4o6s-:: 0143 : ne` 4:00. ," 2!55 0 0 .. 0. 0 40: 40 160 102 t-"G' %dlom; 1.270 • ne -3.5.56 70.43 . 0 0 0 0 ; 0 - 0 �� 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 .A I'LIL-D 1Aclom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 :0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 W 13A4ocs 0.143. s 4.00 2.55 0 0. 0 0 0 0 0 .0 .0 13A4ocs 0.143 sw' 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 I I 13A-4ocs 0143 nw 4.00 2.55 0 0 U 0 0 0 0 a -1A c1om,. , 1.270 nw 35.56 45:24 0 0 0 b " 0 '" 0 " 0 0 I 4A5 tom . 0.770 nw 21.56 27.54 0 0.. .0.' 0 '. 0 0. - P Ii 12C-0sw 0.091 - 2.55 1.28 64 64 163 82 0 0 0 0 C r .16A-30md 0.032 - 0.90.. 2.32 : 192 _ 192 172 . 445 . 45 .45 40, 104 F 1_ I� 22A-tpl _ - 0.989 : - 27.69 0.00 192 0 0 0 45 5 138 0 i 6 c)AED m excursion -27 -2 En,ivelope loss/gain 335 501 339 204 12 a) ',Infiltration 0 0 87 24 b) J Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 I'll Appliances/other 2000 0 Subtotal (lines 6 to 13) 335 2501 426 228 Less extemal load Less . transfer 0 0 0 0 0 0 Roe�istribidion .. 0 0 0 0 0 0 14 15 ' Subtotal Duct loads ' ` 335 2501 426 228 31% 48% 104 1194 31% 48% 133 109 Total room load Air required (cfm) 439 21 3695 162 559 27 336 15 III Calculations approved byACCA to meet all require 11I wcightsoft - A&Right-Suite® Universal 2017 17.0.14 RSU08101 Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N 2017-Apr-10 17:14:63 Page 3: I ' + w ightsoft Right-M Worksheet Job: 'i Entire House Byte: I QUICK CALLS, INC. 317 ST. L' CIE LN., FT. PIERCE, FL 34946 Phone: 772A66-6799 Fax 772A66-6796 Email: QUICKCALCS AOL.COM 1 • Room name BEDROOM 2 ENTRY 2Bgiosed wall 32.2 ft 7.0 ft 3 RQom height 8.0 ft heat/cool 8.0 ft heat/cool 4. Room dimensions 1.0 x 203.5 ft 1.0 x 55.0 ft 5 Room area 203.5 ft2 55.0 ft2 Tyll Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft'L'F) (Stuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool �I 6 i 13A-4ocs 0.143 ne., 4:00 �2:55 128 12t3 513 326 0 0 0, '. "' 0 1A 16m 1.276 -,ne. 35.56 70.43 0 0 0 0 0. 0 0 0 G W 13A-4ocs 0.143 se 4.00 2.55 80 56 225 143 48 26 106 67 1Ac1om 1.270 se 35.56 34.77 24 24 848 829 0 0 0 0 L 1' 11 11DO 0.390 se 10.92 11.31 0 0 0 0 22 22 236 244 W II13A4ocs 0.143 s 4.00 2.55 34 34 136 86 0 0 0 0 II 13A4ocs 0.143 sw 4.00 2.55 16 16 64 41 8 8 32 20 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 I�1A-clom 13AAocs 0.143 - nw 4.00 2:55 0 0 0 .0 0 0 0 0 1Ac1om; 1.270, nw 35.56 45.24. 0 0 0 0 0 0 0. 0 4A5-2om 0;770 '. nw 21:56 27.54 0. 0- 0 0 0 0 0 0 P 12C-0sw 0.091, 2.55 1.28 0 0 0 0 72 72 183 92 C 16A 30md '- 0.032 - 0.90. ' 2.32. 204 204 182 . 472 55 .55 49 128 F I i. I I 22A-tpl 0.989 - 27.69 0.00 204 32 891 0 55 7 194 - 0 - II 6 c)AD excursion -24 -6 Envelope loss/gain 2859 1873 Soo 545 12 a) infiltration . 564 154 122 34 b) ;Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1. 230 0 0 h Appliances/other 0 0 Sub>otal (lines 6 to 13) 3422 2257 922 579 Less'extemal load Less transfer 0 0 0 0 0 0 0 _ 0 Redotribution 0 0 0 0 14 Subtotal 3422 2257 922 679 ' 15 buc fl1loads • 31 %a 48% 1064 1078 31 % 48%a 287 276 Total 'room load Air �2quired (cfm) 4486 218 3335 146 1209 59 855 , W Calculations �wrights Right -Suite® Universal 2017 17.0.14 RSU08101 , . dghtsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N of Manual NI/-Apr--1u-1/:"14:oo Page 4 -vi rightsofV Right4@ Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 317 ST. L UCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS cDAOL.COM 1 Room name LAUNDRY GREAT/DINING • 2 Eosed wall 6.0 ft 46.0 ft 3' 4 R: m height R dimensions 8.0 ft heat/cool 8.9 ft heat/cool 5 m R' m area 7.0 x 6.0 ft 42.0 ft2 1.0 x 488.0 ft 488.0 ft2 TJ Construction U-value Or HTM Area (ft Load Area Lo number(Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 f� 13A-46cs . 0:143 ne- 4:00' Z95 , 0 :" 0 " 0 .: 0 - 231 194 77.5 -493 1A1om 35:51i 70:43 : - 0 r " : . " 0 ': ' 0 0 `" 38'• 0 ." 1344 ._ '' 2662 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 IA-c1om 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 ! 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W ,'� 13A4ocs. 0.143 s," 4.00 2.55 0 0 0 0 0 0 0 0 W 13A4ocs 0.143 sw 4.00 2.55 48 48 192 122 0 0 0 0 1A-c1om 13Mocs lAc1om . 1.270 0.143 9:270 sw , nw nw, 35.56 4.00 35.56 42.91 2:55 45.24 0 .0 0 0 0 0 0 0 0 0 0 0 0 178 0: 0 ' 137 0 0 -M 0 0 .349 0 4A52om'.. _0.770 my 21.56 •27.54 0 .0 0 0 41 0: 880 1124 P 12C-0sw 0.091 - - 2.55. 1.28 .56 56 143 72 0 0 0 0 C � 16A30 6d - 6032 -. 490 2.32 42 42 -. 38 , 97. :-; ;488 488 ' 437::•. F. I i 22A tpI 0.989 _ - 27.69 0.06 42 6 166 0 488 ,` - 46 .. . 1274 .1132 . 0 6 c) . n ,D emursion -3 -56 En4ope loss/gain u. 539 288 6259 5704 12 a) ,Infiltration 105 29 895 245 b) Room ventilation 0 0 0 0 13 Inte 1al gains: Occupants @ 280 0 0 2 460 Appliances/other 0 0 Subtktal Qines 6 to,13) 644 :aV 6154 6409 Less, extemal load 0 0 Lesslikransfer 0 0 0 0 Re4tritwtion 0 0 - 0 0 0 0 14 15 • S[7,;ubtotal' D,uctl,;dads�• ,- . • . 6954 6 409 31% 48% 200 151 31% 48% Tot room load 844 468 8067 " 9469 Air required(cfm) 41 21 393 416 Of �. Right -Suite® Universal 201717.0.14 RSU08101 Twrilghtspft ghtsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N 2017-Apr-10 17:14:53 Page 5 317 ST..' I �I Duct S stem Summa Job. ightsoft Date: Entire House By: QUICK CALCS,INC. LN., FT. PIERCE, FL 34946 Phone: 772-46676799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For: WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL Exteml??l'I static pressure Press4e losses Available static pressure Supply��i return available pressure Lowestfriction rate Actual lair flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 ft jl ame Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH I1 ,M2 h 559 27 15 0.376 4.0 OxO VIFx 18.1 115.0 st1 BEDRO I.� h 4486 218 146 0.374 6.0 Ox0 VIFx 18.6 115.0 st1 BEDRO;Q M-A h 3501 170 149 0.297 6.0 Ox 0 VIFx 33.1 135.0 st2 BEDROOM-B I h 3501 170 149 0.284 6.0 OxO VIFx 41.1 135.0 st2 EITI-RY h 1209 59 38 0.510 4.0 OxO VIFx 3.0 95.0 GREAT/IIIDINING c 4735 196 208 0.318 7.0 Ox0 VIFx 22.4 135.0 st2 GREAT/DINING-B c 4735 196 208 0.307 7.0 OxO VIFx 28.1 135.0 'st2 KITCHENII1 c 3695 21 162 0.375 7.0 Ox0 VIFx 18.3 115.0 st1 LAUNDRY BATH Ii h 844 41 21 0.366 6.0 Ox 0 VIFx 21.6 115.0 st1 M. h 1162 57 54 0.366 4.0 Ox0 VIFx 21.6 115.0 st1 WIC ,I c 214 4 9 1 0.310 1 4.0 Ox 0 1 VIFx 1 26.3 1 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Named Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 ji Peak AVF 737 724 0.284, 689 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx - wrightsofts Right -Suite® Universal 2017 17.0.14 RSU08101 zck .-YVrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N 2017-Apr-10 17:14:54 Page 1 Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Namg Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx