HomeMy WebLinkAboutENERGY EFFICIENCY CODE - 4-16-18FORM R405-2017
I
FLO IDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Flc ida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street:11 THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: `0`'Q S�� �.� Jurisdiction:
Design Lpcation: F , Fort Pierce County:: St. Lucie (Florida Climate Zone 2 )
1. New co Istruction
or existing
New (From Plans)
9. Wall Types (1432.0 sqft.)
Insulation
Area
2. Single f
mily or multiple family
Single-family
a. Concrete Block - Ext Insul,
Exterior R=4.1
1224.00 ftZ
of
b. Frame - Wood, Adjacent
R=11.0
208.00 ftZ
3. Number
units, if multiple family
1
c. N/A
R=
ftZ
4. Number
'of Bedrooms
3
d. N/A
R=
ftZ
5. Is this aorst
case?
Yes
10. Ceiling Types (1753.0 sqft.)
Insulation
Area
a. Under Attic (Vented)
R=30.0
1753.00 ftz
6. Conditio
ed floor area above grade (ftZ)
1753
b. N/A
R=
ftZ
Conditio'
ed floor area below grade (ftZ)
0
c. N/A
R=
ftZ
11. Ducts
R ftZ
7. Window
(151.4 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 225
a. U-Fa
or: Sgl, U=0.63
111.36 ftZ
SHG
: SHGC=0.25
b. U-Fa
or: Sgl, U=0.65
40.00 ftZ
12. Cooling systems
kBtu/hr
Efficiency
SHGI
SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor:
N/A
ftZ
SHG�J:
d. U-Factor:
N/A
13. Heating systems
kBtu/hr
Efficiency
SHG&
ftZ
a. Electric Heat Pump
34.8
HSPF:8.50
Area Weighted
Average Overhang Depth: 2.850 ft.
(�
C1��
Area Wei
°�hted Average SHGC:
0.239
14. Hot water systemsMY
8. FloorT
y'II
p'es (1753.0 sqft.)
Insulation Area
a. Electric p Cap:40gallons
��LhUdeC69jn
a. Slab -On
-Grade Edge Insulation
R=0.0 1753.00 ftZ
b. Conservation features
y
EF:0.970
b. N/A
R= ftZ
None
c. N/A
R= ftZ
15. Credits
Pstat
Glass/Flo
lr Area: 0.086
Total Proposed Modified Loads: 53.83
PASS
Total Baseline Loads: 53.85
I hereby ce I ify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code. 11 11---"\ _ _ /-) I
PREP]
DATE:
I hereby ce ify that this building, as designed, is in compliance
with the Floida Energy Code. -
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
- Complia 'ce requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Complian,e requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402. 1
Flu,
!npG
L7 4
4/16/2018 9,22 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
i
f
FORM R4
5-2017
PROJECT
Title:
WYNNE THE WINDSOR IM Bedrooms: 3
Address Type:
Street Address
Building
ype: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: Yes
PlatBook:
Builder fame:
WYNNE DEVELOPMENT Rotate Angle: 225
Street:
THE WINDSOR
Permit O
ice: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdictipn:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Tripe:
Single-family
FL,
New/Exisljing:
New (From Plans)
Commend
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Numbed Name
Area Volume
1
Entire House
1753 14024
SPACES
Numbe4l
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2
WIC
63 504 No
0
1
No
Yes
Yes
3
MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4
M. BATH
61 488 No
0
1
Yes
Yes
Yes
5
LAUDRY
36 288 No
0
1
No
Yes
Yes
6
BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7
DINING/GREAT R
588 4704 No
2
1
Yes
Yes
Yes
8
KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9
BATH
50 400 No
0
1
Yes
Yes
Yes
10
HALL
25 200 No
0
1
No
Yes
Yes
FOYER
92 736 No
0
1
Yes
Yes
Yes
Ll
BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
Slab -On -Grade Edge Insulatio
MASTER BEDRO 37 ft 0
224 ft2
----
0 1
0
Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ftZ
----
0 1
0
Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ftz
----
0 1
0
Slab -On -Grade Edge Insulatio
M. BATH 7 ft 0
61 ftz
----
0 1
0
I
Slab -On -Grade Edge Insulatio
LAUDRY 1 ft 0
36 ftz
----
0 1
0
4/16/2018
8 22 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 5
FORM R4
5-2017
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft 0
180 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 ft 0
588 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN 11 ft 0
209 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
50 ft2
----
0
1
0
0Slab-On-Grade Edge Insulatio
HALL 1 ft 0
25 ft2
----
0
1
0
11SIab-On-Grade Edge Insulatio
FOYER 9 ft 0
92 ft2
----
0
1
0
I12Slab-On-Grade Edge Insulatio
BEDROOM 3 14 ft 0
169 ft2
----
0
1
0
ROOF
/
V
1'�#
Roof Gable
Roof
Solar SA Emitt
Emitt
Deck
Pitch
Type Materials
Area Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed
Metal 1847 ft2 292 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented 150
1753 ft2
N
N
CEILING
# Ceiling Type
Space R-Value
Ins Type
Area
Framing Frac Truss Type
Under Attic (Vented)
MASTER BEDRO 30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC 30
Blown
63 ft2
0.1
Wood
Ia Under Attic (Vented)
MASTER BATH 30
Blown
56 ft2
0.1
Wood
Under Attic (Vented)
M. BATH 30
Blown
61 ft2
0.1
Wood
1 'I Under Attic (Vented)
J
LAUDRY 30
Blown
36 ft2
0.1
Wood
Under Attic (Vented)
I
BEDROOM 2 30
Blown
180 ft2
0.1
Wood
Under Attic (Vented)
DINING/GREAT 30
Blown
588 ft2
0.1
Wood
Under Attic (Vented)
I
KITCHEN 30
Blown
209 ft2
0.1
Wood
Under Attic (Vented)
BATH 30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL 30
Blown
25 ft2
0.1
Wood
1' Under Attic (Vented)
FOYER 30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3 30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Spaceue Et In
Height
Et In
Arpm
Sheathing Framing
R-Vahle
Solar
Below
1
NEI=I>W
Exterior Concrete Block - Ext IndMASTER BE 4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
2
S"
>E Exterior Concrete Block - Ext Ins)JASTER BE 4.1 7
0 8
0
56.0 ft2
0
0
0.5
0
3
NW=>S
Exterior Concrete Block - Ext InsMWSTER BE 4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
4
NE
>W Exterior Concrete Block - Ext In9dASTER BA 4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
4/16/2018
i 22 PM EnergyGauge®
USA - FlaRes2017 Section R405.4.1
Compliant Software
Page 3 of 5
'
FORM R405-2017
WALLS
Adjacent
Cavity ity Width
Height
Sheathing Framing Solar
Below
5 N�=>W Exterior
Concrete Block - Ext InsuM. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.5
0
J]
6 NE=>W Exterior
Concrete Block - Ext InMDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.5
0
_
_ 7 SrII>E
Exterior
Concrete Block - Ext IndXNING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.5
0
_ 8 N'I
=>S Exterior
Concrete Block - Ext IndNNING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.5
0
9 SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.5
0
10 N =>W Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.5
0
11 S IEI =>N Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.5
0
_
I
12 S
=>E Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
13 N >W Exterior
Concrete Block - Ext InfiffDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.5
0
14 S
>E Exterior
Concrete Block - Ext InREDR00M 3
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
15 N SW Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.5
0
DOORS
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>N Insulated FOYER
I
None
.39
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/
Wall
Overhang
V #
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NW=>S 3
Metal Low-E Single Yes
0.63 0.25
N
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2
NE=>W 5
Metal Low-E Single Yes
0.63 0.25
N
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
3
NE=>W 6
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
4
SW=>E 7
Metal Low-E Single Yes
0.63 0.25
N
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5
NW=>S 8
Metal Low-E Single Yes
0.65 0.21
N
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6
NE=>W 13
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
I'
GARAGE
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scop
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehollse
Proposed ACH(50) .000356 1636.1 89.82
168.92
.2598
7
4/16/2018 822 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
i
FORM RJ 5-2017
HEATING SYSTEM
I#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
I#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 1
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
SEC
Collector
Storage
ert # Company Name
System Model # Collector Model # Area
Volume
FEF
i
(None None
ft2
I'
DUCTS
--- Supply ---
--- Return ----
Air
CFM 25
CFM25
HVAC #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
I1
Attic
6 225 ft2
Attic
65 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programa6le Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinI
Feb
Jan Feb
Mar
Mar
Apr
E Apr I
Jul
May Jun Jul
IMa rj Jun rl
Au
Au
ri
Se
Sep
rj
E j
Oct
Oct
Nov
Nov
H
Dec
Dec
H
Ventin
Jan Feb
X Mar
[X] A r
May JunJul
Aug
Se
IX
Oct
Nov
Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule T)pe
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (W
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (W)
AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WE
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (W
N)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
4/16/2018 ji5 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
1
2017 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Projct Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Des& Location: FL, Fort Pierce
I I
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General'
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
require i ents
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
WindowslIl, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim jois I I
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(includin
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cant
evered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl spice walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, p �netrations
Duct shafts, utility penetrations, and flue shafts opening to
I
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
II
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recesse
lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing
and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring-
Shower/t
i¢
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior,
wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/
hone box o
The air barrier shall be installed behind electrical or communication
exterior w
�lls
boxes or air -sealed boxes shall be installed.
HVAC register
boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
aIe
When required to be sealed, concealed fire sprinklers shall only be
ECon
ers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire spr*nkI cover plates and walls or ceilings
a. In addition, inspection of log walls shall be m accordance with the provisions of ICC-400.
4/16/2018 153 PM EnergyGaugeO USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM
17
1. New c
2. Single
3. Numb]
4. Numb]
5. Is this
6. Condii
7. Windc
a. U-F
b.
C.
d. U-F
SH
Area V
Area V
8. Floor'
a. Slat
b. N/A
c. N/A
I certify tha
Construct](
in this hom
based on iI
Builder Sig
Address of
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
THE WINDSOR, FT. PIERCE, FL,
uction or existing
New (From Plans)
9. Wall Types
Insulation
Area
ly or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0
208.00 ft2
units, if multiple family
1
c. N/A
R=
ft2
Bedrooms
3
d. N/A
R=
ft2
rst case?
Yes
10. Ceiling Types
Insulation
Area
a. Under Attic (Vented)
R=30.0
1753.00 ft2
t floor area (ft2)
1753
b. N/A
R=
ft2
Description
Area
c. N/A
R=
ft2
Sgl, U=0.63
111.36 ft2
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 225
SHGC=0.25
Sgl, U=0.65
40.00 ft2
SHGC=0.21
12. Cooling systems
kBtu/hr
Efficiency
N/A
ft2
a. Central Unit
34.8 SEER:15.00
rc: N/A
ft2
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
34.8 HSPF:8.50
hted Average Overhang Depth:
2.850 ft.
hted Average SHGC:
0.239
s Insulation
Area
14. Hot water systems
-Grade Edge Insulation R=0.0
1753.00 ft2EF:
a. Electric
Cap: 40 gallons
0.97
R=
ft2
R=
ft2
b. Conservation features
None
15. Credits
Pstat
this home has complied with the Florida Energy Efficiency Code for Building
h through the above energy saving features which will be installed (or exceeded)
before final inspection. Otherwise, a new EPL Display Card will be completed
I Code compliant features.
ature: Date:
�ew Home: ,,\X5.`S'��2\ 'Q\ \A�City/FL Zip:
I5 I
F
k
0!
WE
"Note: I;I This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortg ge (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsu'Dport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certifie J Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/16/118 8:53 PM EnergyGauge@ USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1