HomeMy WebLinkAboutPRODUCT APPROVAL - ROOF DECK - 9-26-18I : M
1/9/2018
Florida Building Code Online
SCIS-Home Log In User Registration
Hat Topics Submit Surcharge Stats & Facts Publications j FBC Staff BCIS SRe Map !
Links Search
Product Approval
Mora
USER! Public User
Product Approval Menu > Product or Apolimtion
Search > Aooilcatlon Ust > Application Detail
• ' +•
FL #
FL9555-114
Application Type
Code Version
Revision
2017�UI����
Application Status
Approved o
Comments
Archived
Product Manufacturer
UNION CORRUGATING COMPANY
Address/Phone/Email
701 S. KING ST.
FAYETTEVILLE, NC 28301
(910)483-0479 Ext256
jstleby@unioncorrugating.com
Authorized Signature
John Stieby
jstleby@unioncorrugating.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
® on L
ei
c ,
Category
Structural Components
I--4 Q
Subcategory
Roof Deck
LLJ
U o
LLJ r-1 U
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
�G
Professional Engineer
I
Evaluation Report - Hardcopy Received
i-
Florida Engineer or Architect Name
who developed Bala Sockalingam
the Evaluation Report
Florida LJcense
PE-62240
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration
Date 09/07/2027
Validated By
Yoosef Lavl, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL9555 R4 COI Certificatelndeoendence.odf
Standard
ASTM E1592
FM 4470
Year
2005
2012
113
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Florida Building Code Online
Method 1 Option D
08/23/2017
08/28/2017
09/09/2017
12/12/2017
FL #
Model, Number or Name
Description
9555.1
5V Panel
29 ga., 24" wide, through fastened panel over wood supports
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL9555 R4 II EvaluationReoortC2172 1.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-70.25
Evaluation Reports
Other: Uplift load of 70.25 psf @ support spacing of 24" o.c.
FL9555 R4 AE EvaluationReoortC2172 1.odf
Created by Independent Third Party: Yes
9555.2
MasterRib Panel
26 ga., 36" wide, through fastened panel over steel supports
Limits Use
Installation Instructions
overt for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL9555 R4 II EvaluationReoortC2172 2.adf
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-47.2
Evaluation Reports
Other: Uplift load of 47.2 psf @ support spacing of 60" o.c.
FL9555 R4 AE EvaluationReoortC2172 2 odf
Created by Independent Third Party: Yes
9555.3
MasterRib Panel
29 ga., 36" wide, through fastened panel over steel supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL 9555 R4 II Evaluation ReoortC2 172 3.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +27.1/-37.7
Evaluation Reports
Other: Design load of 27.1 & -37.7 psf at support spacing of
FL9555 R4 AE EvaluatlonReoortC2172 3.odf
48" o.c.
Created by Independent Third Party: Yes
9555.4
MasterRib Panel
29 ga., 36" wide, through fastened panel over wood supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II Evaluation Repo rtC2172 4.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +27.1/-36.2
Evaluation Reports
Other: Design load of 27.1 & -36.2 psf at support spacing of
FL9555 R4 AE Eva luationReoortC2172 4.odf
48" o.c.
Created by Independent Third Party: Yes
9555.5
MasterRib Panel
29 ga., 36" wide, through fastened panel over nom. i" x 4"
wood supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL9555 R4 II Eva luationReoortC2172 5.odf
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-138.9
Other: Uplift load of 138.9 psf @ support spacing of 24" o.c.
Evaluation Reports
FL9555 R4 AE EvaluationReoortC2172 5.odf
Created by Independent Third Party: Yes
9555.6
PBR Panel
Min. 26 ga., 36" wide, through fastened roof panel over open
steel supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationReoortC2172 6.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +96/-163
Evaluation Reports
Other: Design loads of 96 & -163 psf at support spacing of
FL9555 R4 AE EvaluationReoortC2172 6.odf
20" o.c.
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EED employer. Coovriaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mall address released In response to a public -records request, do not send electronic
i.om/or/or aoD dU.asox7Daram=wGEVXQwtDatvOROQkZA5RE8EOaziUdl7ntuFlu2iC5s%3d 2/3
1l9l2018 Florida Building Code Online
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. "Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emalls provided may be used for oMdal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. Tb determine If you are a licensee under Chapter 455, F.S.,
please dick here .
Product Approval Accepts:
Credit Card
Safe
httpsJ/ww,w.floridabuilding.org/prlpi app_dtl.aspx7param=wGEVXQwtDgtvOROQkZA5RE8EOgziUdi7ntuFlu2jC5s°/a3d 3/3
I ' ,
I
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
`29 GA. 5V PANEL'
OVER WOOD SUPPORTS
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 9555.1-R4
STRUCTURAL COMPONENTS
ROOF DECK
I
Prepared For:
Union Corrugating Company
P. O. Box 229
Fayetteville, NC 28302
Telephone: (910) 483-0479
Fax: (910) 483-8897
I
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
Report No. C2172-1
Date: 8.20.2017
y,ta390o06VI1;sl"
GYALr;VQ J'.,LU
No p
oCGm
OF
O PL 0C?
FL 9555.1-R4
C2172-1
8.20.2017
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: 5V Panel
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Minimum 29 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Support Description: Nom. V x 4" (min) lumber (Southern Yellow Pine Untreated)
(Must be designed by others)
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 70.25 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2) (3 or more spans)
j Panel Attachment: #9-15 or #10-14 x 1-1/2" long wood screws with washer
At panel ends @ 12" o.c. across panel width
j At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with ASTM E1592-01 `Test
! Method for Structural Performance of Sheet Metal Roof and Siding
Systems by Uniform Static Air Pressure Difference' and FM 4470
Section 5.5 `Resistance to Foot Traffic'.
j Test Equivalency: The test procedure in ASTM E1592-01 comply with test procedure
j prescribed in ASTM E1592-05(2012).
The test procedure in FM 4470 (1992) comply with test procedure
j prescribed in FM 4470 (2012).
Code Compliance:
Product Limitations:
I
The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. The design uplift pressure for reduced support spacing may
be computed using rational analysis prepared by a Florida Professional
Engineer. This product is not approved for use in the High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2017 Section 1505 and current
approved roofing materials directory for fire ratings of this product.
I I
FL 9555.1-R4
C2172-1
8.20.2017
Page 3 of 3
Supporting Documents: ASTM E1592 Test Report
Farabaugh Engineering and,Testing Inc
Project No. T246-06, Revised Reporting Date 11/7/06
I
FM 4470 Test Report
ENCON Technology Inc
C1583-3, Reporting Date 7/24/08
I
I
i
I
I
I
PANEL FASTENER
#9-15 OR #10-14 X 1.5" LONG WOOD
SCREWS @ MAX 12" O.C.
p
a
FASTENER PATTERN NOM. X (MIN) a
SYP UNTREATED ,� +
SUPPORT SPACING = 24" O.C. (DESIGN BY OTHERS) Q
ALLOWABLE UPLIFT PRESSURE = 70.25 PSF
oil
a,
12'
Id
24•
E
a
z2v
5V Panel Profile oK
Minimum 29 Gouge, Minimum Yield - 80 KSI
U�
i=to-mta
% tr
Sheet No.