HomeMy WebLinkAboutPRODUCT APPROVAL - ROOF DECK1/9/2018 \ Florida Building Code Online
r a
BCIS Home I Login User Registration Hot Topics Submit Surcharge i Stats & Fads ( Publications ! FBC Staff I BCIS Site Map, I Links i aSearch, F
Florida
id,11%,
nl .. Product Approval
4y; USER: Public User
Product Approval Menu > Product or ADDlication
Search > Application List > Application Detail
FL #
FL9555-114
Application Type
Revision
Code Version
2017
Application Status
Approved
o,
/f
Comments
C1,
Archived
Product Manufacturer
UNION CORRUGATING COMPANY
Address/Phone/Email
701 S. KING ST.
FAYETTEVILLE, NC 28301
(910)483-0479 Ext256
jstieby@unioncorrugating.com
Authorized Signature
John Stieby
jstieby@unioncorrugating.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Structural Components
Roof Deck
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Bala Sockalingam
PE-62240
Keystone Certifications, Inc.
09/07/2027
Yoosef Lavi, P.E.
v Validation Checklist - Hardcopy Received
FL9555 R4 COI CertificateIndenendence.Ddf
Standard Year
ASTM E1592 2005
FM 4470 2012
hftps://www.flo�idabuildinq.orq/i)r/Dr aoo dtl.aSDx?Daram=wGEVXOwtDatvOROOkZA5RE8EOaziUdl7ntuFlu2iCtis%3d 1/1
i
1/9/2018
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Prndur_te
Florida Building Code Online
Method 1 Option D
08/23/2017
08/28/2017
09/09/2017
12/12/2017
FL #
Model, Number or Name
Description
9555.1
5V Panel
29 ga., 24" wide, through fastened panel over wood supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationReDortC2172 1.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
De ' ressure: +N/A/-70.25
Evaluation Reports
ther: Up ift load of 70.25 psf @ support spacing of 24" o.c.
FL9555 R4 AE EvaluationReDOrtC2172 i.odf
Created by Independent Third Party: Yes
9555.2
MasterRib Panel
26 ga., 36" wide, through fastened panel over steel supports
Limit o se
Installation Instructions
owed for use in HVHZ: No
FL9555 R4 II EvaluationReoortC2172 2.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-47.2
Evaluation Reports
Other: Uplift load of 47.2 psf @ support spacing of 60" o.c.
FL9555 R4 AE EvaluationReDOrtC2172 2.Ddf
Created by Independent Third Party: Yes
9555.3
MasterRib Panel
29 ga., 36" wide, through fastened panel over steel supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationReDortC2172 3.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +27.1/-37.7
Evaluation Reports
Other: Design load of 27.1 & -37.7 psf at support spacing of
FL9555 R4 AE EvaluationReportC2172 3.Ddf
48" o.c.
Created by Independent Third Party: Yes
9555.4
MasterRib Panel
29 ga., 36" wide, through fastened panel over wood supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationReoortC2172 4.Ddf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +27.1/-36.2
Evaluation Reports
Other: Design load of 27.1 & -36.2 psf at support spacing of
FL9555 R4 AE EvaluationReoortC2172 4.odf
48" ox,
Created by Independent Third Party: Yes
9555.5
MasterRib Panel
29 ga., 36" wide, through fastened panel over nom. 1" x 4"
wood supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationReportC2172 5.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-138.9
Evaluation Reports
Other: Uplift load of 138.9 psf @ support spacing of 24" o.c.
FL9555 R4 AE EvaluationReDOrtC2172 5.0f
Created by Independent Third Party: Yes
9555.6
PBR Panel
Min. 26 ga., 36" wide, through fastened roof panel over open
steel supports
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL9555 R4 II EvaluationReDOrtC2172 6.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Design Pressure: +96/-163
Created by Independent Third Party: Yes
Evaluation Reports
Other: Design loads of 96 & -163 psf at support spacing of
20" o.c.
FL9555 R4 AE Eva IuationReportC2172 6.Ddf
Created by Independent Third Party: Yes
Sack Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
https://www.flolidabuildina.orci/Dr/Dr aDD dtl.asox?Daram=wGEVXOwtDotvORC)Ok7A5RFRFnn7iilril7ntiiFlii9i(`5cp/.Irl IM
1/9/2018 Florida Building Code Online
mail to this entity. Insteaa, con tact the office by phone or Illy traditional mall. If you have any questions, please contact 850.487.1395. "Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
f one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
W� ® eCFEck IM
Credit Card
Safe
https://www.floridabuildino.ora/Dr/Dr aoD dtl.asox?Daram=wGEVXOwtDntv()RCXJk7A5RFRFnn7ilirli7ntiiFlii9ir.rcO/'Iri zit
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
`26 GA. MASTERRIB PANEL'
OVER STEEL SUPPORTS
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 9555.2-R4
STRUCTURAL COMPONENTS
ROOF DECK
Prepared For:
Union Corrugating Company
701 S. King St.
Fayetteville, NC 28301
Telephone: (910) 483-0479
Fax: (910) 483-1091
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover)
Installation Details (1 Page)
Load Span Table (1 Page)
Report No. C2172-2
Date: 8.20.2017
Qa��aaaaace�
�90®°OGKALIN(3 Poe
ee� 5.••.N S E '••l�, °°e
d ;cso JA
A � �� Doti
8
FL 9555.2-R4
C2172-2
8.20.2017
Page 2 of 3
Manufacturer: Union Corrugating Company
Product Name: MasterRib Panel
Panel Description: 36" wide coverage with 3/4" high ribs at 9" o.c.
Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painted steel (ASTM
A755).
Support Description: Min 16 ga., 50 ksi steel. (Must be designed by others)
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2
Design Uplift Pressure: 47.2 psf @ maximum support spacing of 60" o.c.
(Factor of Safety = 2)
Support Attachment: #12-14 x V long self -drilling screws with washers
At end supports @ 3.5"-5.5"-3.5" o.c. across panel width
At intermediate supports @ 9" o.c. across panel width
Sidelap Attachment: 1/4"-14 x 7/8" long SDS with washer @ 30" o.c.
Test Standards: Roof assembly tested in accordance with ASTM E1592-01 `Test
Method for Structural Performance of Sheet Metal Roof and Siding
Systems by Uniform Static Air Pressure Difference' and FM 4470
Section 5.5 `Resistance to Foot Traffic'.
Test Equivalency: The test procedure in ASTM E1592-01 comply with test procedure
prescribed in ASTM E1592-05(2012).
The test procedure in FM 4470 (1992) comply with test procedure
prescribed in FM 4470 (2012).
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. The design uplift pressure for reduced support spacing may
be computed using rational analysis prepared by a Florida Professional
Engineer or based on Union Corrugating load span table. This product
is not approved for use in the High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2017 Section 1505 and current approved roofing materials
directory for fire ratings of this product.
FL 9555.2-R4
C2172-2
8.20.2017
Page 3 of 3
Supporting Documents: ASTM E1592 Test Reports
Farabaugh Engineering and Testing Inc.
Project No. T163-06, Reporting Date 6/7/06
FM 4470 Test Report
ENCON Technology Inc.
j C1583-2, Reporting Date 7/24/08
a
INTERIOR SUPPORTS
MIN 16 GA. STEEL -
(DESIGNED BY OTHERS)
END SUPPORTS
MIN 16 GA. STEEL -
(DESIGNED BY OTHERS)
MASTERRIB
PANEL
MIN 16 GA. STEEL -
(DESIGNED BY OTHERS)
/— PANEL FASTENER
/ ® 9" O.C.
PANEL FASTENER
3.5"-5.5"-3.5" O.C.
SEE PANEL SIDELAP
DETAIL
jMASTERRIB ��
PANEL
MASTERRIB
PANEL
TYPICAL PANEL INSTALLATION X—SECTION
PANEL FASTENER
O 9" O.C.
SIDELAP FASTENER MASTERRIB
PANEL
1/4"-14 SOS WITH
WASHER ® 30" O.C.
PANEL FASTENER
12-14 x 1" LONG
DS WITH WASHER
MIN 16 GA. STEEL
(DESIGNED BY OTHERS)
PANEL SIDELAP
SIDELAP FASTENER
® 30" O.C.
MAX 60" O.C.
(SEE LOAD SPAN TABLE FOR
ALLOWABLE LOADS AND SPANS)
SECTION VIEW
SIDELAP FASTENER
® 30" O.C.
SIDELAP FASTENER
30" O.C.
PANEL FASTENER
3.5"-5.5"-3.5" O.C.
GENERAL NOTES:
1. ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA
BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE 26 GA. (t = 0.017"). EFFECTIVE COVERING WIDTH
OF PANEL = 36".
3. ROOF PANELS SHALL BE INSTALLED OVER STRUCTURE AS SPECIFIED ON THIS
DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT.
THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE DESIGN LOADS.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL
6. SUPPORTS MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
7. PANELS MAY SPAN BETWEEN EAVE TO RIDGE SUPPORTS OR RAKE TO RAKE
SUPPORTS.
OF
UNION CORRUGATING COMPANY
MasterRib Roof Panel
36" wide, 26 ga. (min) Steel Panel over Steel Supports
Span
Condition
Loading
Type
Allowable Load (psf)
Support Spacing (ft)
1.50
1.75
2.00
2.50
3.00
3.50
4.00
4.50
5.00
Two Span
Uplift
138.3
118.5
103.7
83.0
69.2
59.3
51.9
46.1
37.7
Three Span
Uplift
157.2
134.7
117.9
94.3
78.6
67.4
58.9
52.4
47.2
jFour or More
Spans
Uplift
151.3
129.6
113.4
90.8
75.6
64.8
56.7
50.4
44.1
Notes:
1. Allowable load for each condition is the smallest load calculated based on fastener capacity, panel strength and
and deflection limit of L/180. Allowable loads are calculated for minimum 26 ga. panel.
2. The wind load is taken as 0.7 times the "component and cladding" loads for the purpose of determining deflection limit.
31: The panel allowable properties are determined from full scale ASTM E1592 tests at 5' 0" span
4. The panel fasteners are #12-14 x 1" long self drilling screws with washers. Fastener spacing across panel width
is 9.0" o.c. in the interior supports and 3.5"-5.5"-3.5" o.c. at panel ends.
51. Sidelap fasteners are 1/4"-14 x 7/8" long self drilling screws with washer at 30" o.c.
61. Steel supports are minimum 16 ga. All supports must be designed to resist all loads imposed on the panel.
71 The panels may span from eave to ridge or rake to rake.
8: Panels must be installed as per Evaluation Report FL 9555.2 and Union current installation procedure.
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
918192 5992
-a. -2o. 2c3 tr7
Bala Sockalingam, Ph.D., P.E.
PE 62240