STRUCTURAL COMPONENTS
ROOF DECK
UNION CORRUGATING COMPANY
FL9555.2-R4
26 Gauge MasterRib Panel
12/12/17
STRUCTURAL COMPONENTS
STRUCTURAL WALL
UNION CORRUGATING COMPANY
FL9555.2-R4
26 Gauge MasterRib Panel
12/12/17
-EXTERIOR DOORS-
SWINGING
- EL-IXER-DOOR AND-METAL--COMPANY
-FL17996.5-R1
Series 407
01/29/18
EXTERIOR DOORS
ROLL -UP
ASTA INDUSTRIES INC.
FL8888.1-R5
Model 203
10/07/11
_I
ST. Lucie County, Permitting
FRONT ELEVATION
SCALE: 1/8'.,1, . .
THESE PLANS AND ALL PROPOSE® WORK
ARE SUBJECT TO ANY, COflRECTIONS :
REQUIRED BY FlEW INSPECTORS THAT
1MY. DE_ NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
LEFT SIDE.ELEVATION
SCALE: 1/8'=1 CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
G,cuaaNcvcRouP:
GENERAL NOTES:
CONSTRUCTION TYPE:
1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN
ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESSIEGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATIONS AND SLOPES, OR OTHER LOCAL ZONING RISK CATEGORY:
REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS.
�- BUILDING'_EN CLOSURE
2. THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE
LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED
WIND EXPOSURE CATEGORY:
PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CARPORTS ANYWHERE, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S
RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS.
ULTIMATE WIND SPEED (MPH):
3.
ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.
NOMINAL DESIGN WIND SPEED (MPH):
4.
ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL.
MEAN ROOF HEIGHT (FEET):
5.
ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 x 1' SELF DRILLING SCREWS WITHOUT CONTROLSEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED.
ROOF ANGLE (DEGREES):
-6.-GONCRETESHALL HAVE -A- MINIMUM. COMPRESSIVE- STRENGTH OF 2500 PSI AT-B DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL
-DESIGN PRESSURES (PSF):
BE REINFORCED WITH 6X6-W1 AXW1 .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116.
ROOF:
7.
CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260; OR EQUIVALENT.
ZONE 1:
ZONE 2:
8.
POST/RAFTER BRACING: BRACE ON EVERY POSTIRAFTER CONNECTION„EXCEPT FOR END WALLS AND GABLE ENDS.
ZONE 3: -
DESIGN ROOF PRESSURES:
9.
SLAB FOUNDATION'SUBGRADE SOILS SHALL BE TERMITE TREATED.AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING CODE, SIXTH EDITION
(2017) - RESIDENTIAL, AND SECTION 1816.1 OF THE FLORIDA BUILDING CODE, SIXTH EDITION (2017) -BUILDING. MINIMUM ALLO ABLE FOUNDATION SOIL CONTACT BEARING PRESSURE
WALLS:
OF 21000 PSF IS ASSUMED. , b>!�
ZONE 4:
ZONE 5:
10.
14 GA FRAMING:"2-112' x 2-1/2'-TUBE STEELjTS) WITH 2-1/4' x 2-114' TS NIPPLES.
ST. I:UCI E COUN
DESIGN WALL PRESSURES:
12GAFRAMING: 2-1/4'x2-1/4'TSWITH2'x2'TSNIPPLES..
BUILDING DIVI N
REVIEW
SWINGING DOOR:
FOR CO IANC
ROLL -UP DOOR:
DATE
SWINGING DOOR PLANS A4
MUST.BE KEP'
NO INSPECTION
II I,
o
RIGHT SIDE ELEVATION
SCALE: 118' ='l'
IOR
MADE METAL FRAMING AND SIDING PREFABRICATED BY
CARPORTS ANYWHERE
P.O. BOX 776
STARKE, FL 32091`
THESE ENGINEERING DRAWINGS ARE THE PROPERTY
OF BECHTOL ENGINEERING &.TESTING, INC. AND
CARPORTS ANYWHERE, INC: THESE DRAWING MAY
NOT BE REPRODUCED WITHOUT THE WRITTEN
CONSENT OF BECHTOL ENGINEERING & TESTING; INC.,
AND CARPORTS ANYWHERE, INC. "
REAR ELEVATION
SCALE: 118' =1'
py
C
150
116
14.08
14.0
+16.0 / -25.9
+16.0 / -36.5
+16.0 / -57.6
+16.01.29.9
+26.7 / -29.1
+26.7 / -32.5
+26.71.29.8
+29.91.325
+28.01.30.7
THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS.
HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL
ENGINEER, AND.ARE IN ACCORDANCE WITH THE REQUIREMENTS OF
SECTION.1609 OF THE FLORIDA BUILDING CODE; SIXTH EDITION (2017).
THE PLANS ARE:VALID UNTIL THE NEXTREVISION OF THE FLORIDA
BUILDING CODE.
BECHITOL ENGINE] I11140, AND.
605 WEST NEW YORK QENUE
DELAND, FLORIDA 32f2%L
Certificate of Au_ tho aftan IE65d92 NO,
S38 =
omas Bechtol; E.
Florida License No. �•7gT�O T'.
EVA \\ ➢ V
''/�! / ► i l l l00.
PROPOSED UTILITY STRUCTURE
4781 JORGENSEN ROAD
FORT PIERCE, FLORIDA-
.. 4/30/18
BECHTOL ENGINEERING ' . NM '�'�; .NOTEDMV . .
AND791"N47n�
coNwuao �mmaNru oN�aroEwx� A.6 �u>ott�s -i- dtn -
"'°" MKE1 " "�"� .G18002
ArFr ®0 TB. SHEET 1 OF 3
'L
A'
FRONT POST[TRUSSED RAFTER FRAMING PLAN
SCALE: VV =1'
LEFT SIDE POST/TRUSSED RAFTER FRAMING PLAN
SCALE: 118' = V
CONCRETE:
Concrete Shall Have a Minimum Specified Compressive Strength of 2500 PSI at28 Days
COVER OVER REINFORCING STEEL
For foundations, minimum concrete cover over reinforcing bars shall be:
3 inches in foundations where the concrete is cast against and permanently in contactwith the earth or exposed to the earth
or weather, and 1-1/2 inches elsewhere. Reinforcing bars embedded in grouted cells shall have a minimum clear distance of
1/4 inch for fine grout or 1/2 inch for coarse grout between reinforcing bars and any face of a cell. Reinforcing bars used in
masonry wells shall have a masonry cover (including grout) of not less than 2 inches for masonry unit with face exposed to
earth or weather 1-112 inches for masonry units not exposed to earth or weather.
REINFORCING STEEL:
The reinforcing steel shall be minimum Grade 40.
GALVANIZATION:
Metal accessories for use in exterior wall construction and not directly exposed to the weather shall be galvanized in
accordance with ASTM A 153, Class B-2. Metal plate connectors, screws, bolts and nails exposed directly, to the weather
shall be stainless steel or hot dipped galvanized.
REINFORCEMENT MAY BE BENT IN THE SHOP OR THE FIELD PROVIDED:
1. All reinforcement is bent cold;
2. The diameter of the bend, measured on the inside of the bar, is not less than sic -bar diameters; and
3. Reinforcement partially embedded in concrete shall not be field bent
EXCEPTION:
Where bending is necessary to align dowel bars with a vertical cell, bars partially embedded in concrete shell be
permitted to be bent at a slope of not more than 1 inch of horizontal displacement to 6 inches ofver ical bar length.
26 GA. GALVANIZED METAL ROOF PANELS FASTENED
TO PURLINS WITH (2) #12-14 x 1' SDPs WITH CONTROL
SEAL WASHER @ MAXIMUM 9' O.C. SPACING
WELD, CONTINUOUS, ALLSIDES,
TOP AND BOTTOM TRUSS CHORDS
26 GA GALVANIZED METAL WALL PANELS FASTENED
TO POSTS WITH (2) #12-14 x 1' SDPs WITH CONTROL
SEALWASHER.@.MAXIMUM 9' O.C_SPACING.
WELD ALLCHORD
CONNECTIONS,
BOTH SIDES
30
TYPICAL INTERIOR POST/TRUSSED RAFTER SECTION
SCALE: 1/8' =1'
1' 16 GAUGE FURRING CHANNEL FASTENED TO EACH
RAFTER WITH (2) #12-14 x 314' SELF -DRILLING FASTENER SPACED
NOT MORE THAN 48' O.C.
26 GA. METAL ROOF PANEL
( —TS RAFTER
ROOF PANEL ATTACHMENT
Not To Scale
2-1/4' FOR
16 GAUGE U-CHANNEL BRACE
12 GA FRAMING
FASTENED TO THE POST AND
2-11T FOR
RAFTER, WITH (2) #12-14x 3/4'
14 GA FRAMING
SELF -DRILLING SCREWS AT
EACH END (4 PER BRACE)
BRACE SECTION -
Not To Scale
REAR POST[TRUSSED RAFTER FRAMING PLAN
SCALE: 1/8' =1'
RIGHT SIDE POSTITRUSSED RAFTER FRAMING PLAN
SCALE: 1/8' =1'
R H
GE C
BECHTOL ENGik NG AND TESTING,)Q
605 WEST NEW YORK AVENUE No. 38538
DELAND, FLORIDA-S2720 ;
Certificate of AuthoriFatrg NA. 5492
1 -44 4—
omas Becht , P.OIAII� F
E. T
Florida License 38 -k 'Q<ORIDP . .
�ONALIE����`.
PROPOSED UTILITY STRUCTURE
4781 JORGENSEN ROAD
FORT PIERCE, FLORIDA
ra3a
BECHTOL ENGINEERING NM
AND JESTING, Ina
mrau�mm cm>Ecremx D&I'M auL, M uATIUMS 7ESrM Dxxraces
C.vk adamxr fto�
4/30/18
°C" E NITS
°RQLa G18002
SHEET 2 OF 3
THROUGH BASE RAIL WITHIN 6' OF EACH
BOW ALONG SIDES OR INSIDE EVERY
OTHER END WALL POST ALONG END
WALL SECTIONS
MINIMUM 2-1/4' EMBEDMENT
GROUND SURFACE
MONOLITHIC CONC. FOOTING (2500 PSI MIN.)
REINFORCED WITH 2 #6s CONTINUOUS
r,_-�_CONCRETE MONO. SLAB BASE RAIL ANCHORAGE
� Not To Scale
TS TRUSSED RAFTER CHORD,
OR NON-STRUCTURAL HEADER
TS END POST OR DOOR/
WINDOW FRAME POST
TS NONSTRUCTURAL HEAL
(12 GA FOR ROLL -UP DOOR FRAA
BASE RAIL, OR WINDOW R
2'xTx2' 16 GA ANGLE CUP
SECURE TO POST (EACH SIDE) AND
RAFTER CHORD/RAIL WITH (4) #12-14 x 314'
SDF's, (2) ON BOTTOM AND (2) ON SIDE
NOTE: AT ROLL -UP DOOR OPENINGS,
POST SHOULD BE FLUSH WITH RAIL
END. CLIP POST TO RAIL ONLY ON
SIDE OPPOSITE THE OPENING.
POST TO NON-STRUCTURAL HEADER, BASE
RAIL OR WINDOW RAIL CONNECTION DETAIL
5 Not To Scale
TS BOX EAVE RAFTER
NIPPLE TO\ 311
RAFTER
48' 16 GA U-CHANNEL BRACE
BRACE ANGLE SHALL BE MIN.45'
TO MAX. 60° FROM HORIZONTAL
MINIMUM 6' LONG TS NIPPLE
SECURE RAFTER AND POST
--TO NIPPLE WITH (4J#12-14 x 3/4'
SELF -DRILLING FASTENERS
of
TS RAFTER POST
BOX EAVE RAFTER/CORNER POST
CONNECTION DETAIL
L Not To Scale
TS POST
(12 GA FOR ROLL -UP DOOR FRAME)
2' x 2' x 2' 16 GA ANGLE CLIP
SECURE TO POST AND TOP OF
HEADER, OR BOTTOM OF WINDOW
RAIL/GIRT WITH #12-14 x 3/4' SOPS
TS NONSTRUCTURAL HEADER
(12 GA FOR ROLL -UP DOOR FRAME)
TS OR
IRT
FOR VERTICAL
SIDING
ING OPT
FOR VERTICAL SIDING OPTION
NON-STRUCTURAL HEADER OR WINDOW
6 RAIL TO POST CONNECTION DETAIL
Not To Scale
NIPPLETO 3116'
BASE RAIL
SECURE WITH (4) #12-14 x 3/4'
SELF -DRILLING FASTENERS
-TS RAFTER POST
f TS CONTINUOUS BASE RAIL
i
RAFTER POST/
BASE RAIL CONNECTION DETAIL
3 Not To Scale
TS
2'x2'x2' 16 GA ANGLE CLIP
SECURE TO POST AND
RAFTER WITH #12-14x 3/4'
SOPS, (2) ON TOP AND
(2) ON SIDE
OR
TS END POST 2'x V 16 GA PLATE
SECURE TO EACH SIDE OF
POST/RAFTER CONNECTION
WITH (4) #12-14 x 3W SDFs,
(2) ON POST, (2) ON RAFTER
7 END POST/RAFTER CONNECTION DETAIL
Not To Scale
NIPPLETO 3116'
BASE RAIL
,—MINIMUM 6' LONG TS NIPPLE
SECURE WITH (4) #12-14x 3l4'
SELF -DRILLING FASTENERS
TS RAFTER POST (CORNER)
1-1/2' x 1-112' x 2' 16 GA CLIP
ANGLE, SECURE TO RAFTER
\i i POST AND BASE RAIL
„ i WITH (4) #12-14 x 3/4' SDFs
�� TS CONTINUOUS BASE RAIL
4 END POST/BASE RAIL CONNECTION DETAIL
Not To Scale
3116' WELD, BOTH SIDES,
TOP AND BOTTOM
(TYPICAL ALL TRUSS POSTS)
TS POST
3/16' WELD, CONTINUOUS,
ALL FOUR SIDES, TOP AND
BOTTOM TRUSS CHORDS
TRUSSED RAFTER CENTER CONNECTION DETAIL
8 Not To Scale
\\"\�\%IIII )//////
BECHTOL ENGINtE a14p"j 7 i
605 WEST NEW YORfG�tV
DELAND, FLORIDA ,Z2720 ' • •• O i
Certificate of Authorimfion No.549
Thomas Becht P.
Florida License STATE
s•
i •' . ORIDA •.•'� � �
//oNgL iENG\
PROPOSED UTILITY STRUCTURE
4781 JORGENSEN ROAD
FORT PIERCE, FLORIDA
4130118
BECHTOL ENG/NEERM o NM NTS
AND TE87YAf y hw-
'0 MKB '"OLNO G18002
� TB SHEET 3 OF 3