HomeMy WebLinkAboutEVALUATION REPORT - ASPHALT SHINGLESOwens Corning Parkway
Jo, OH 43659
) 4047829
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization IY9sm
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report 037940.02.12-118
F1.10674-1113
Date of Issuance:02/06/2012
Revision 8: 10/09/2017
SFOPE:
This Evaluation .Report is ,issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation subrnitted'has been reviewed by Robert Nieminen,
PIE. for use of the product under the Florida Building- Code and Florida Building Code, Residential Volume. The
products described 'herein have been evaluated 'for .compliance with the 6th 'Edition (2017) Florida Build' �g Code
s ictions.noted herein. 'CANNED)
DESCRIPTION: Owens Corning.Asphalt.Roof Shingles BY
89 Lude county
LABELING: Labeling shall be in accordance with. the requirements the Accredited Quality Assurance Agency noted
herein and FBC`15071.7.1 / R905 2:,6:1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality. Assurance documentatiion changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report:by.the ham, ed-client -constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced• Quality Assurance. documentation changes. TrinitylfRD requires, a complete.
review of this Evaluation Report relative to:.updated'Code requirements with each Code Cycle.
ADVERTISEMENT__ The,Eva'Iuation.Report number preceded by the words "Trinity;�ERD Evaluated." maybe displayed in
advertising literature..If any. portion ofthe Evaluation'Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation -Report shall -be provided to the. user by the manufacturer or
its
and shallbeavailable for inspection'at the job site at the request -of the.Building Official.
This Evaluation Report:consists of pages 1 through 8.
Pr�pared by:
Robert J.M: Nieminen, P.E.
Florida RegistrationNo. 59166, Florida DCA ANE1983
i
The facsimile seal appearing was authorized by Robert
Nleminen, P.E. on 10/09/2o17. This does not serve as an
CERTIFICATION. oF-INDEBENDENEE: electronically signed document.
1ITrinityI ERD does -not have, nor doesit intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing,•prod ucts'�it, eva I uates.
2- ITrinityI ERD.is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,?.-E does. -not have nor will acquire, a financial Interest in any company manufacturing or distributing, products for
which the evaluation reports are,being Issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
broduct.
S. This is a building. code;evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any
project on which this Evaluation .Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
I
ROOFING SYSTEMS EVALUATION:
11. SCOPE:
Product Category: Roofing
Sub -Category.: Asphalt Shingles
Compllance,Statement: Owens Corrnng.Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance wkh'the following sections of the 6`h' Edition (2017) .Florida Building Code and Florida Building Code,
Residential Volume through, testing in accordance with the following Standards. Compliance is subject to the
Installation Requirements andLimitations./ Conditions. of Use set forth herein.
2. STANDARDS:
Section Prone Standard Year
1507:2,5, R905.2.4 Physical Propertles ASTM 63462 2010
1507.2.7.1, R905.2.6.1 WiridResistance ASTM D3161 2016
1507.2.7.1, 11905c2.6.1 WlndResistance ASTM D7158 2011
3. REFERENCES:
Enti Examination Reference Date
UL LLC (CER9626) Physicals.& Wind Resistance File R2453, Vol. 3 02/15/2007
UL LLC (CER962,6) Physicals & Wind Resistance 20120516-R2453 05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006
UL.LLC (TST9628) Wind Resistance 11CIA34308 02/18/2012
UL LLC (TST9628) Physicals& Wind. Resistance 4786093.137 02/01/2014
UL LLC (TST9628) Wind Resistance. 4786126532 02/10/2014
1 UL LLC (TST9628) Physical .Properties Classification letter 02/13/2014
Mi LLC (TST9628) Physical Properties Classification letter 10/02/2015
Miami -Dade (GER1592) FBC HVHZ Compliance Varlous,NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation Exp. 05/16/2020
41 PRODUCT DESCRIPTION:
1 4.1 Asphalt:Shinsles:
1 4.1.1 Classic and- Supreme`.are fiberglass reinforced, 3-tab asphalt roof shingles.
1 4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roofshingles.
4.1.3 Devonshire'"' are fiberglas&reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinitione Duration, Duration Premium Cool, TruDefinitione Duration® Designer Color
Collection, TruDefinition*Oakridge , Oakridge and WeatherGuarde HP are fiberglass reinforced, laminated
asphalt,roof shingles.
4.2 Hip & Ridge Shingles:
1 4.2.1 Berkshire 'Hip & Ridge Shingles, High Ridge, WeatherGuarde HP Hip & Ridge Shingles; ProEdge Hip & Ridge
Shingles,and DuraRidgeTm'Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Accessoru1tarterStribs:
4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer,of'Record :for any project on which this Evaluation. Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose..
5.2 This Evaluation•Report,is,not for use in FBC HVHZjurisdictions.
I
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
1 for fire. -ratings. of this product.
Exterior Research and Design, I.I.C.
f 6 EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report 03794106742-R8
Ce�cate o AvthoiisatredN95fJ3 '" FL10674R13
Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017
i Page 2 of 8
I
I
6.
1
Jy s \
5_4 Wind:Classifcation: FTRUNTY I ERD
5.4.1 All Owens Corning; asphalt shingles noted herein. are Classified. in accordance with FBC Tables 1507.2.7.1
and R905 2:6:1 to ASTM D3'161, Class; F'and/or ASTM D7158,'Class H, indicating, the shingles are acceptable
for use an all wind zones up to V.,d = 150 mph (Vuit = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.2 All Owens.Corning hip .& ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Class! in, in' accordance with FBC Tables .1507:Z,7:1 and R905.2,6:1 to ASTM D3161, Class F, indicating the
shingles are acceptapleldr use in all wind zones up to V,,d =150 mph (V,it = 194 mph). Refer to Section 6 for
installation',regwrements1o, meet this-wind'rat ng.
5.4.3 Classification,by ASTM D71,A9 applies to exposure categoryB or C, as defined in FBC 1609.4.3, and a mean
roof 'height of 60 feet or ,less Cdlculationis,by a qualifed design professional are required for conditions
outside these limitation's. Contact the shingle manufacturer for data specific to each shingle.
5.4.4 Refer:to Owens Corning'published�inforniation.on wind resistance and installation limitations.
5.5 All.products.in the roof assembly, shall have quality assurance audit:in accordance with F.A.C. Rule 61G20-3.
INSTALLATION:
6.1
6.1.1
6.2
6.2.1
I
6.2.2
6.2.4
6.2.5
Underlavment:
Underlayment shall be :acceptable to ,Owens. -Corning and shall hold current. Florida Statewide Product
Approval! or b61 t. lly Approved. per Rule>61GZO-% per' FBC 1507.2.3 1507.2.4 or R905.2.3.
Asphalt:Shineles:
Installation :of asphalt shingles shall..comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 15Q7i2.7 or .R905.2.6, with the following
exceptions:
, Berkshire ,shingles.require,minimum five (5) nails per shingle.
➢ WeatherGuacde HP shingles require.minimutnsix (6) nails per shingle.
DevonshikdTM'shingles require minimum;six-(6) nails per shingle.
➢ Starter Strip Shilogle and Starter,strip Plus, require- minimum: five (5) nails per strip.
Refer to,,Owens Co ningpublished information on wind resistance and installation limitations.
Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507:2:6 or R90S.2.5. Staples are not permitted.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required; •See.figures ,1%elovii fo.r details.
Minimum Nailing—Starter'Strip'Shingle and. Starter Strip Plus:
Exterior Research and Design, LLc.
Certljlchee of Aurhbrizarlon %195t13
kltrerdeihyment coat Sdkdved
undedWnM
DdP • "� Oripadge
t ' `r bated
r�]•fromave
ruwflnlsmmrsatPPw.edneiH
wifli S" mnowd Po3ltimtrd chip ewe
6T" EDITION (2017);FBC NON=HVHZ EVALUATION
Owens Corning Asphait Roof 'Shingles
Evaluation Report 037940.02.12-R8
FL10674-R13
Revision 8:10/09/2017
Page 3 of 8
I --
6.2.6 -Minimum .Nailing—Classic®.&Supreme:
Mennrd,or Arwpwn
10 VYhd' diWs'- tp;y
tioaa Ghinulfwr'Nk-
I
6.2.7 Minimum:Nailing—.Berkshire®:
Standard Fastening Pattern
SeahMSViq
Le *8 di sdkdot
"BsYi'' 8.Y1' 8'Vt'
tY'
2° Ahelt:roofinpcement
Ceindito:do'tarA'odo'astako
Mansard or Steep,$lope fastening Pattern
I
I
I
I
I
Exterior Research and Design, LLC;
Certlfhate ofAathodzation N9503 6'" EDITION (2017).FBC NON-HVHZ EVALUATION
Oweris Corning Asphalt Roof Shingles
Manwd.or Awa.pwa
tuati'un�a dm�AW:'
AIM �ilant�d ,Iu rta:
... ..:
6-Nail Fastening Pattern
Evaluation Report 037940.02.12-R8
FL10674-R13
Revision 8:10/09/2017
Page 4 of 8
I
6.2.9 Minimum Nailing — 'Duration®, TruD;efinition° Duration, Duration® Premium Cool & TruDefinitiono
I Duration Designer Color�Collection:
-N*II Fgstening!PatDam.
. _ .. � ;eiiwiaDr�dryiVd{w.wdli
- iiu;iypka:
"BIRFastening Pattern
anws®im.nmo.,mpam�
P"Ir 12"
$tar dacd?Fastenirig,'Pattern- ti-Nail!Fasienina Pattern
I
I
I
i
I
I
I
I
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-118
Cord lT of Authorization.1.9503 6T" EDITION (2017) FBC NON.HVNZ EVALUATION FL10674-R33
Owens Corning Asphalt Roof Shingles Revision 8:10/09/2027
• Page 5 of 8
I
I
6.2.1 Minimum Nailing —TruDefinition'0akridge®,O,akridge®:
i
.6:NafbF'atEem
EsQueria tom6davos
66I8" Expaepta
rorai,;d.sr�spur�:
i
Standard. Fastening Pattern
Pattern
6.2.1 Minimum Nailing —WeatherGuardPfHP:
I
�■
_ �, 1Ybb:bftdil
:'�•:': - :titi: 4 . i �f17d1111�1 N1i1 {�
Exterior Research and Design, LLC.
lrcrtfjl-�te ofAath.d.-atfon #9503 6'" EDITION (2017) FBC'IdORI-HVHZ EVALUATION
Owens Corning Asphalt Roof Shingles
1 i M, i '�d (-f '� '
W
&6/8" EXPM. t I I
fupwwn * 6B/Spafg
Evaluation Report 037940.02.12-118
FL10674-R13
Revision 8:10/09/2017
Page 6 of 8
"\JTRNTYjERD
6_3 Hip.& Ridge Shingles:
6.3.1 Installation of Berksh_ ire Hip and Ridge Shingles, High Ridge, Weather:GuardO HP Hip and Ridge Shingles
and PtoEdge .Htp &Ridge Shingles shall comply with the Owens Corning current published instructions,
using four :'(4) nails pershingle. Installation of DuraRidWo Hip & Ridge Shingles shall comply with the
Owens Corning current. published instructions, using two (2) nails per shingle. Refer to Owens Corning
published :information on wind resistance and installation limitations, including the use of hand -sealing for
wind warranties.
6.3.2 Fasteners, shall, be in accordance with. the manufacturer's published requirements, but not less than FBC
1507.26;.0� R905.2:5, Staples are not permitted.
6.3.3 Minimum Nailing —Berkshire® Hip &-Ridge and High. Ridge:
6.3.4 Minimum Nailing: WeatherGuard® HP,Hip and Ridge:
'Fig.A. 4
PrewYmg,Wlnll.
.. E—Gliaelbn
Wallet ���44
A
- A
' I
A I I t
t
II
Ettterlor Research and Design, LLC.
Cerfg!-'te ofAvthadhalm N9s03
I
I
Fig.C'Hip-&_Ridge Shingle:Fastening
7oP.AW
NoILs Halts
r
7 2"
s� exposure
EDITION (2017) FBC WON-HVHZ EVALUATION
Owens Coming Asphalt hoof Shingles
Evaluation Report 037940.02.12-118
FU0674-R13
Revision 8:10/09/2017
Page 7 of 8
0
0
6.3.5 Minimum Nailing-'ProEdge. Hip & Ridge:Shingles:
wln8 olreotlon &dint strip
Cever Eglaed�
r . , Far�inxiwkh
RiiafC�mint;
St6ederd r--11°--•
ftoWnin®
P004M
12' I Sealant
�.
7 h 61 Exp tre
6.3.6 Minimum: Nailing —Duraltidge'"° Hip°&:Ridge Shingles:
Note: lhe drawings below pertain to;mini►num, as-tested,attachment requirements. Refer to Owens Corning
publish. ed;installation instructions'for-their-minimum reauirements-
'Dainndom�imiii&n
Mcdoidi114", "'pidoiiiliento
7L LABELING:
7.1 Labeling shall be in accordance with the requirements the .Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance.with one of the required classifications detailed in FBC
Tal ie 1507..1.7.1 /•IZ9. d5.2.6.1.
8 BUILDINGRERMITREQUIREMENTS,
As required :by the Building Official or AuthorityHaving Jurisdiction in order to properly evaluate the installation of
this product.
9.I MANUFACTURING PLANTS:
Contact the named. QA entity for information on which plants .produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE' ENTITY:
UL LLC— QUA9625.; (631) 546-2458; Kanchi-Agrawala-Dokania@ul.com
END•OF•EVALUATION REPORT -
I
Exterior Research and Design, LtC.
Certificate of Authorization#9563,
6T" EDITION (2017) FBC NON•HVHZ EVALUATION
Oweng Coming,Mphalt Roof Shingles
Evaluation Report 037940.02.12-118
FL10674-R13
Revision 8:10/09/2017
Page 8 of 8