HomeMy WebLinkAboutEVALUATION REPORT - HURRICANE SEIMIC STRAPS AND TIES FOR WOOD FRAMINGSECTION: 06 05 23—WOOD, PLASTIC, AND COMPOSITE FASTENINGS SCANY0 7 REPORT HOLDER: SIMPSON STRONG -TIE COMPANY INC. 5956 WEST LAS POSITAS BOULEVARD PLEASANTON.. CALIFORNIA 94588 EVALUATION SUBJECT: SIMPSON STRONG -TIE° HURRICANE AND SEISMIC STRAPS AND TIES FOR WOOD FRAMING ICC ICC n ICC c� PMG cLISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPQ Award in Excellence" ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to anv finding or other ma. tter in this report, or as to arty product covered by the report. \\ Muni A Subsidiary of coDECOUNcir sccA..dWd SO isont¢c noes Rodud CW60C.du� 8.dY _An rOCPS cm .7000 Copyright 0 2017 !CC Evaluation Service, LLC. All rights reserved. IC -ES Evaluation Report wwww.icc-es.org 1 (800) 423-6587 1 (562) 699-0643 DIV SION: 06 00 00—WOOD, PLASTICS, AND COMPOSITES Section: 06 05 23—Wood, Plastic, and Composite Fastenings REFORT HOLDER: SIM 2SON STRONG -TIE COMPANY INC. 695 i WEST LAS POSITAS BOULEVARD PL ASANTON, CALIFORNIA 94588 (800) 925-5099 www.stronutie.com EVALUATION SUBJECT: SI IPSON STRONG -TIE® HURRICANE AND SEISMIC ST PS AND TIES FOR WOOD FRAMING 1.0 EVALUATION SCOPE C mpliance with the following codes: ■ 2015, 2012, 2009 and 2006 Intemational Building Code® (IBC) ■ 2015, 2012, 2009 and 2006 International Residential Code® (IRC) Property evaluated: Structural 2.0 USES e Simpson Strong -Tie® hurricane and seismic straps d ties described in this report are used as wood framing nnectors in accordance with Section 2304.10.3 of the 15 IBC and Section 2304.9.3 of the 2012, 2009 and 06 IBC. The products may also be used in structures lulated under the IRC when an engineered design is bmitted in accordance with Section R301.1.3 of the IRC. 3.01 DESCRIPTION General: Simpson Strong -Tie hurricane and seismic straps and recognized in this report are installed to resist design :s on wood -frame construction resulting from the !cation of the most critical effects of the load binations prescribed by code that include wind or nic loads. 1 Hurricane Ties: Hurricane ties are used to anchor id rafters or joists to wood wall plates or studs or to hor wood studs to wood sill plates. The H6 and H7Z ESR-2613 Reissued June 2017 Revised December 13, 2017 This report is subject to renewal June 2018. A Subsidiary of the International Code Council® ties are formed from No. 16 gage galvanized steel; the H1, H2.5A, H3, H5, H10A, and H10-2 ties are formed from No. 18 gage galvanized steel; and the H4 tie is formed from No. 20 gage galvanized steel. See Table 1 for tie model numbers, tie dimensions, fastener schedules, and allowable loads. See Figures la and lb for illustrations of the hurricane ties recognized in this report, and Figure 1c for illustrations of installation configurations with designated allowable load directions. 3.1.2 HS24 Hurricane Tie: The HS24 hurricane tie anchors wood rafters or trusses to wood wall top plates. The HS24 connector is formed from No. 18 gage galvanized steel. See Table 2 for required fasteners and allowable loads. See Figure 2 for a drawing of the HS24 tie and a typical installation detail. 3.1.3 LTS, MTS, and HTS Series Twist Straps: The LTS, MTS, and HTS series twist straps are used to anchor wood trusses or rafters to wood wall double top plates, wood studs, wood beams, or wood rim boards. The LTS, MTS, and HTS series twist straps are formed from No. 18, No. 16, and No. 14 gage galvanized steel, respectively. See Table 3 for strap model numbers, overall strap lengths, required fasteners, and allowable uplift loads when installed with different fastener schedules. See Figure 3 for a drawing of an LTS12 twist strap and two typical MTS strap installations. 3.1.4 LFTA Light Floor Tie Anchor: The LFTA light floor tie anchor is used as a floor -to -floor tension tie and is formed from No. 16 gage galvanized steel. See Table 4 for anchor tie dimensions, required fasteners, and the assigned allowable uplift load. See Figure-4 for a drawing of the LFTA connector. 3.1.6 SP and SPH Series Stud Plate Connectors: The S131 connector fastens one edge of a wood stud to the contiguous edge of a wood sill plate, and the SP2 connector fastens to one side of a wood double top plate and to the contiguous edge of a wood stud. The S134, SP6, SP8, SPH4, SPH6, and SPH8 are 11/4-inch-wide (32 mm) U-shaped straps with a horizontal portion that bears against the wood wall top plates or sill plates and two vertical legs that are nailed to the edges of a wood stud. The SP and SPH connectors are fabricated from No. 20 and No. 18 gage galvanized steel, respectively. See Table 5 for SP and SPH models, connector dimensions, required fasteners, and allowable uplift loads. See Figure 5 for drawings of the SP1 and SP2 connector, and of typical stud -to -plate connection details for the S131, SP2, SP4, and SPH4 connectors. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluailon Service, UC, express or implied as y to airy finding or other matter in this report, or as to any product covered by the report. ® .W =.. Cop I�rright O 2017 [CC Evaluation Service, I.I.C. All rights reserved. Page 1 of 11 31 Most Trusted 2 of 11 1.6 RSP4 Reversible Stud Plate Ties: The RSP4 tie stes are used to connect a nominally 2-inch-wide wood ud to either a top or sill plate of a wood framed wall. The 3134 tie connector is fabricated from No. 20 gage ilvanized steel. See Table 6 for required fasteners and owable loads. See Figure 6a for a drawing of the RSP4 innector showing overall dimensions; Fi ure 6b for a awing of a typical RSP4 installation connecting a wood ruble top plate to a wood stud; and Figure 6c for a typical 3P4 installation connecting a wood stud to a wood sill .1.7 SSP and DSP Stud Plate Connectors: The SSP :ud-to-plate connector is used to provide a positive mnection between a single wood stud and the top or sill ate of the same wood wall, and the DSP stud -to -plate mnector is used to provide a positive connection between double wood stud and the wood wall top or sill plate of e same wood wall. The SSP and DSP connectors are bricated from No. 18 gage galvanized steel. See Table 7 r required fasteners and allowable uplift loads. See ure 7 for drawings of the SSP and DSP connectors lowing overall dimensions; a drawing of an SSP stallation connecting a stud to a sill plate; and a drawing a DSP installation connecting a double wood stud asembly to a top plate. 1.8 HGT Heavy Girder Tiedown Brackets: The HGT mvy girder tiedown brackets are used to provide a )sitive connection between wood roof beams or multi -ply Dod roof trusses and wood posts vertically aligned to ipport the end reaction of the beam or truss member. The 3T tiedown connector is a U-shaped bracket that is stalled over the top chord of the roof truss having a slope 1m 3:12 (14 degrees) to 8:12 (34 . degrees). Other imponents required for the connection, such as the ichor rods and hold-down or tie -down devices, that must used to form a complete load path to resist design uplift rces from their point of origin to the load -resisting :ments, that is, the vertically aligned supporting wood ist, must be designed and specified by the registered sign professional. The HGT tiedown brackets- are Dricated from No. 7 gage steel, and are supplied with ;art plates and crescent washers. See Table 8 for down connector models, connector dimensions, fastener hedules, and allowable uplift loads. See Figure 8 for a swing of the HGT-2 tiedown connector. Materials: ,1 Steel: Unless otherwise noted, the connectors cribed in this report are fabricated from ASTM A653, designation, Grade 33, galvanized steel with a imum yield strength, Fy, of 33,000 psi (227 MPa) and a imum tensile strength, Fu, of 45,000 psi (310 MPa). HTS twist straps, the SSP and DSP stud -to -plate ties, the H2.5A hurricane tie are fabricated from ASTM 6, SS designation, Grade 40, steel with a minimum d strength of 40,000 psi (275 MPa) and a minimum Me strength of 55,000 psi (379 MPa). 1e body of the HGT heavy girder tiedown bracket is •icated from ASTM A1011, SS designation, Grade 33, rolled steel with a minimum yield strength of 33,000 psi r MPa) and a minimum tensile strength of 52,000 psi 3 MPa), and the crescent washers of the HGT bracket fabricated from ASTM A36 steel with a minimum yield ngth of 36,000 psi (248 MPa) and a minimum tensile ngth of 58,000 psi (399 MPa). Base -metal thicknesses for the connectors in this report are as follows: NOMINAL THICKNESS (gage) MINIMUM BASE -METAL THICKNESS (inch) No. 3 0.2285 No. 7 0.1705 No. 10 0.1275 No. 14 0.0685 No. 16 0.0555 No. 18 0.0445 No. 20 0.0335 For 51: 1 inch = 25.4 mm. The galvanized connectors have a minimum G90 zinc coating specification in accordance with ASTM A653. Some models (designated with a model number ending with Z) are available with a G185 zinc coating specification in accordance with ASTM A653. Some models (designated with a model number ending with HDG) are available with a hot -dip galvanization, also known as "batch" galvanization, in accordance with ASTM A123, with a minimum specified coating weight of 2.0 ounces of zinc per square foot of surface area (600 g/m2), total for both sides. Model numbers in this report do not include the Z or HDG ending, but the information shown applies. The HGT Heavy Girder Tiedown Brackets have a painted finish and may also be,available with the HDG finish. The lumber treater or holder of this report (Simpson Strong -Tie Company) should be contacted for recommendations on minimum corrosion resistance of steel' connectors in contact with the specific proprietary preservative treated or fire retardant treated lumber. 3.2.2 Wood: Supporting wood members to which these connectors are fastened must be solid sawn lumber, glued - laminated lumber, or engineered lumber [such as Laminated Veneer Lumber (LVL), Parallel Strand Lumber (PSL), and Laminated Strand Lumber (LSL)] having dimensions consistent with the connector dimensions shown in this report. Unless otherwise noted, supporting wood members and supported members must have an assigned minimum specific gravity of 0.50 (minimum equivalent specific gravity of 0.50 for engineered lumber), except as noted in Table 5 for the SPH stud plate tie connectors, which provides values for which lumber members having assigned minimum specific gravities of 0.50 and 0.55 are required; and Table 7 for the SSP and DSP stud -to -plate tie connectors, which permits lumber having assigned minimum specific gravities of 0.50 and 0.43. The lumber used with the connectors described in this report must have a maximum moisture content of 19 percent (16 percent for engineered lumber) except as noted in Section 4.1. The thickness of the wood members must be equal to or greater than the length of the fasteners specified in the tables in this report, except if noted otherwise in the tables and accompanying footnotes in this report, or as required by wood member design, whichever controls. 3.2.3 Fasteners: Bolts, at a minimum, must comply with ASTM A36 or A307. Nails used for connectors, straps, and ties described in this report must comply with ASTM F1667 and have the following minimum dimensions and bending yield strengths (Fyb): • 3 j Most Widely Accepted and Trusted 0 3of11 FASTENERS NAIL DIAMETER (inch) NAIL LENGTH (inches) F j6 (psi) 8d x 1% 0.131 11/7. 100,000 8d, 0.131 21/2 100,000 10d x 1% 0.148 11/2 90,000. 10d 0.148 3 90,000 SI: 1 inch = 25.4 mm. steners used in contact with preservative treated or retardant treated lumber must comply with Section 1.10.5 of the 2015 IBC, Section 2304.9.5 of the 2012, i and 2006 IBC, Section R317.3 of the 2015, 2012 and I IRC or Section R319.3 of the 2006 IRC, as cable. The lumber treater or this report holder pson Strong -Tie Company) should be contacted for mmendations on minimum corrosion, resistance of ners and connection capacities of fasteners used with specific proprietary preservative treated or fire dant treated lumber. 4.01 DESIGN AND INSTALLATION Design: e tabulated allowable loads shown in this report are sed on allowable stress design (ASD) and include the d duration factor, CD, corresponding with the applicable ds in accordance with the National Design ecifrcatione for Wood Construction (NDS). .abulated allowable loads apply to products connected wood used under dry conditions and where sustained nperatures are 100OF (37.8°C) or less. When products installed to wood having a moisture content greater in 19 percent (16 percent for engineered wood ducts), or when wet service is expected, the allowable ds must be adjusted by the wet service factor, CM, ;cified in the NDS. When connectors are installed in od that will experience sustained exposure to nperatures exceeding 100°F (37.8°C), the allowable ds in this report must be adjusted by the temperature tor, Ct, specified in the NDS. ,onnected wood members must be analyzed for load - Tying capacity at the connection in accordance with the Installation: Ilation of the connectors must be in accordance with evaluation report and the manufacturer's published Ilation instructions. In the event of a conflict between report and the manufacturer's published installation fictions, this report governs. Special Inspection: I Main Wind -force -resisting Systems under the : Periodic special inspection must be conducted for ponents within the main wind -force -resisting system, re required in accordance with Sections 1704.2 and 5.11 of the 2015 IBC, Sections 1704.2 and 1705.10 of 2012 IBC, Sections 1704 and 1706 of the 2009 IBC, Section 1704 of the 2006 IBC. 4.3.2 Seismic -force -resisting Systems under the IBC: Periodic special inspection must be conducted for components within the seismic -force -resisting system, in accordance with Sections 1704.2 and 1704.12 of the 2015 IBC, Sections 1704.2 and 1705.11 of the 2012 IBC, and Sections 1704 and 1707 of the 2009 and 2006 IBC. 4.3.3 Installations under the IRC: Special inspections are normally not required for connectors used in structures regulated under the IRC. However, for components and systems requiring an engineered design in accordance with IRC Section R301, periodic special inspection must be in accordance with Sections 4.3.1 and 4.3.2 of this report. 5.0 CONDITIONS OF USE The Simpson Strong -Tie Hurricane. and Seismic Straps and Ties described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The connectors must be manufactured, identified and installed in accordance with this report and the manufacturer's published installation instructions. A copy of the instructions must be available at the jobsite at all times during installation. 5.2 Calculations showing compliance with this report must be submitted to the code official. The calculations must be prepared by a registered design professional where required by the statues of the jurisdiction in which the project is to be constructed. 5.3 Adjustment factors noted in Section 4.1 and the applicable codes must be considered, where applicable. 5.4 Connected wood members and fasteners must comply, respectively, with Sections 3.2.2 and 3.2.3 of this report. 5.5 Use of connectors with preservative or fire retardant treated lumber must be in accordance with Section 3.2.1 of this report. Use of fasteners with preservative or fire retardant treated lumber must be in accordance with Section 3.2.3 of this report 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Joist Hangers and Similar Devices (AC13), dated February 2017. 7.0 IDENTIFICATION The products described in this report are identified with a die -stamped label or adhesive label indicating the name of the manufacturer (Simpson Strong -Tie), the model number, and the number of an index evaluation report (ESR-2523) that is used as an identifier for the products recognized in this report. ESR-2613 1 Most Widely Accepted and Trusted Page 4 of 11 TABLE 1—HURRICANE TIES J FASTENERS DS'� ALLOWABLE LOA (Quantity Type) (IbS) MODEL NO.:= - To Rafter ` T6: ates To`Stud `" Connection -° Uplift° Laterals' Co-1:6 , a Configurations Co 1.6 IH1 6-8d x 1% 4-8d — 545 510 190 H 10A 10d z .1'/Z 9 =10d 'k 1'!z — H10-2 6-10d 6-10d — 655 430 355 2:5A = t_ 54d .:; f: 5-8d ..: , 2 IH3 4-8d 4-8d — 435 210 170 125. H4 — 4-8d 4-8d 3 330 — — j�H6:.'84d 4-8d 4-8d — 4 330 140 175 :''8-8d ;. 5 .`' 1230.- - — H7Z 4-8d 2-8d 8-8d 6 830 410 For 1 inch = 25.4 mm, 1 Ibs = 4.45 N. 'Allowable ISi: loads are for one anchor installed to a minimum nominal 2x supported and minimum nominal 2x supporting wood member. A rafter mini um actual thickness of 21/2 inches must be used when framing anchors are installed on each side of the rafter and on the same side of the late. ZAllo able simultaneous loads in more than one direction on a single connector must be evaluated as follows: Design Uplift / Allowable Uplift + Design Lateral Parallel to Plate / Allowable Lateral Parallel to Plate + Design Lateral Perpendicular to Plate / Allowable Lateral Perpendicular to Plates 1.0. The three terms in the unity equation consider all possible forces that the hurricane tie may be designed and installed to resist. The number of terms that must be considered for simultaneous loading is determined by the registered design professional and is dependent on the method of calculating wind forces and the assumed load path that the connector is designed to resist. '"connection Configurations" shown in Figure is (next page) indicate the load directions F, and FZ, and are details showing connector instgllations on the outside of the wall for clarity. Installation on the inside of the wall is acceptable to achieve the tabulated allowable loads. 4Cognections in the same area (i.e. truss to plate connector and plate to stud connector) must be on installed on the same side of the wall to achieve the tabulated allowable uplift loads and ensure a continuous load path. 'Allowable uplift loads have been increased for wind or earthquake loading, and no further increase is allowed. Allowable loads must be reduced when other load durations govem. sAllowable requ'red lateral loads in the F, direction must not be used to replace diaphragm boundary members or nailing or replace solid blocking by code to laterally support the ends ofjoists/rafters. 'Additional shear transfer elements must be considered the connector installation induces cross grain bending or tension of the truss or rafter me bars. r 3I41�'�1� 0 0 0 o •- •. ®6 a • `� ; 1�+6 �� Zi 6° 6 ®e its o <• 23 "0 51,9. H1\\►II H2.5A H3 FIGURE 1a-1-11, H2.5A, AND H3 HURRICANE TIES t-2613 I Most IMdel Trusted 5of11 I H10-2 FIGURE 1 b-1-14, H5, H6, H7Z, H10A AND H10-2 HURRICANE TIES El H1 Installation (1-110A and H10-2 similar) H4 Installation v W H2.5A Installation (Nails into both top plates) (1-13 and H5 similar) 4 ° ro H4 Installation (Nails into upper top plate) Uaa a minimum H6 Stud to at woadealie ,f Band i ide p I'llf .o1s Joist nauama �+RIi Installation R ' H6 Stud to Double Top i . � Plate I z -- _ Two ed irelu Intopiafaa. Installation 3 '• i •. EI ®d i+da ` naJIM dada 6 ;; W H7Z Installation FIGURE 1 c—CONNECTION CONFIGURATIONS OF HURRICANE TIE INSTALLATIONS SPECIFIED IN TABLE 1 1 i 3 1 Most Widely Acceptea and Trusted 6. of 11 TABLE 2—HS24 HURRICANE TIE FASTENER$"(Quant-0-Type) ' . ALLOWABLE LOADS (Ibs) Co 1 6 MODEL N0. y To Rafter or Truss To Double Top Plate Uplift Latera l'.+s F� Fz HS24 8-8d x 1 /2 & 2-8d (slant) 8-8d 605 645 1,100 8-8d x 1 /z 8-8d 1 625 625 680 For SI: 1. inch = 25.4 mm, 1 Ibs = 4.6 N. '"Slant" nailing refers to 8d common nails installed as toenails on each side of the connector. The nails must be driven through the connector at an angle approximately 30' with the rafter/truss member with the nail penetrating through the rafter/truss member into the wood double top plate. The uplift loads have been increased for wind or earthquake loading. No further Increase is allowed. Allowable loads must be reduced when other load durations govern. 'Allowable lateral loads in the F, direction must not be used to replace diaphragm boundary members or nailing or replace solid blocking required by code to laterally support the ends of joists/rafters. °Additional shear transfer elements must be considered the connector installation induces cross grain bending or tension of the truss or rafter member. 5F, oad direction is parallel to plate, and F2 load direction is perpendicular to plate. 14" 41 HS24 Dimensions ,., 2W U.S. Patents 5,603,680 HS24 Installation and Allowable Load Directions FIGURE 2—HS24 HURRICANE TIE ES1t.2613 1 Most WidelyAccepte�_—_.J Trusted Page 7 of 11 TABLE 3—LTS, MTS, AND HTS TWIST STRAPS STRAP SERIES ST L--- MODEL NO STRAP ". LENGTH _ (m) TOTAL QUANTITY OF FASTENERS' ALLOWABLE UPLIFT LOADs2?-, bs) Wh' Installed wrth 10d Common Nails Wfien Installed with 1odx1'IZ Common Nails When Installed with 10d Common Nails When Installed with 10dx1'l= Coromoe Nails Co. Via, j :. Co=:Cat.- -= LTS4 LTS12 12 12 12 660 600 LTS16 16 LTS18 18 LTS20 20 MTS MTS12 12 14 MTS16 16 MTS-18 = 18 Y; MT S20 20 MTS30 . , 30 HTS16 16 16 16 1,310 1,310 HTS5 HTS20 20 20 24 1,310 1,310 HTS24 24 HTS28 28 HTS30 30 HTS30C 30 For ISI: 1 inch = 25.4 mm, 1 Ibs = 4.45 N 'Ha)f of the fasteners must be installed on each end of the strap to achieve the allowable uplift load. 2Tabulated allowable uplift loads must be selected based on duration of load as permitted by the applicable building code. 'Tabulated allowable uplift loads have been increased for wind or earthquake loading. No further increase is allowed. Allowable loads must be reduced when other load durations govern. 'Each model of the LTS and MTS twist strap series (except for the MTS30) has more nail holes than the minimum quantity of nails specified in the table. 5HT630C has the twist in the center of the strap length. 1' Typ. 1114- LTS12 (MTS and HTS Similar) Typical MTS Installation — Rafter to Stud FIGURE 3—TWIST STRAPS Typical MTS Installation — Truss to Double Top Plate ESR-2613 1 Most Widely Accepted and Trusted 8Of11 TABLE 4—LFTA LIGHT FLOOR TIE ANCHOR! MODEL NO ;: LFTA ANCHOR DIMENSIONS (in) ] PASTENERSZ ;- piantity Type) .: ALL.OWABLE.TEN810N LOAD34 (Ibs); ' Co =1.6 Strap Wdth'(VV) ':Clear Span, Overall Length (L) LFTA 21/4 17 383/8 16-10d Common 1,325 For 51: 1 inch = 25.4 mm, 1 Ibs = 4.45 N. 'Th LFTA anchor is used to transfer tension forces between vertically aligned wood studs across floor framing with floor joists having a maximum nominal depth of 12 inches. 2Half of the fasteners must be installed on each end of the strap to achieve the allowable uplift load. 'Tabulated allowable uplift loads must be selected based on duration of load as permitted by the applicable building code. 4Tabulated allowable uplift loads have been increased for wind or earthquake loading. No further increase is allowed. Allowable loads must be reduced when other load durations govem. FIGURE 4—LFTA LIGHT FLOOR TIE ANCHOR l 3 1 Most Widely Acceptea an Trusted 9of11 TABLE 6—SP AND SPH STUD PLATE TIES CONNECTOR' SERIES:'` : MODEL, CONNECTOR ._ -DIMENSIONS (In) `=, ;FASTENERS'. '" . (Quantity=Type) '-,' ALLOWABLE UPLIFT LOADS23jS ' y pbs) =i (IIV) (L) To Stud To Plate . S G=0 50 S G. 0 55 SP1 — — 6-10d 4-10d 555 555 SP2 — — 6-10d 6-10d 1,010 1,010 SP4 39/1s 71l4 6-10d x 1'/2 — 825 825 6-16d x 2'/2 — 850 850 SP SP6 5@/1@ 73/a 6-10d x 1'/2 — 825 825 6-16d x 2% — 850 850 SP8 75/16 85/16 6-10d x 11/2 — 825 825 6-16d x 2'/2 — 850 850 SPH 804 3B/te 19.0-1 Ud x 1 2 — 1,040 12 :1t7dx 1�/2 1 280 ° SPH6 5B/16 91/4 s s 12 10d x 1'/2 W 1 sz80 G~ s 1415 80H8 79h6 83/@ 10-1Od x 1,4 For SI: 1 inch = 25.4 mm, 1 Ibs = 4.45 N. 'Fort Models SP1 and SP2, one 10d common stud nail must be installed as a toenail. It must be driven through the connector at an angle approximately 30° with the stud with the nail penetrating through the stud into the wood sill plate. (See detail on this page entitled "SP1 Nailing Prolle.1 2Tabulated allowable uplift loads must be selected based on duration of load as permitted by the applicable building code. 3Ta ulated allowable uplift loads have been increased for wind or earthquake loading. No further increase is allowed. Allowable loads must be red ced when other load durations govern. °Allgwable uplift loads are given for wood assemblies consisting of lumber having an assigned specific gravity (S.G.) of 0.50, such as Douglas fir —I rch, and 0.55, such as southern pine. I`5tudj L r m' 11 'k v° SP1/SP2 Typical SPH4Installation: Stud to Wood Sill Plate (SP4 Similar) SP2 Installation: SP1 Nailing Profile Stud to Double Top Plate SP1 Installation: Stud to Sill Plate Typical SP4 Installation: Double Top Plate to Stud (SPH Similar) FIGURE 5—SP AND SPH STUD PLATE TIES 3 1 Most INdelyAcceptL _: d Trusted TABLE 6—RSP4 REVERSIBLE STUD PLATE CONNECTOR' 10of11 MODEL t . FASTENERS (Quantity -Type) ALLOWABLE LOADS' (Ibs)'Co 1 6 ' To Stud ' To Plate Connectidn Confguration4 Uplift Lateral6 F, `. FZ RSP4 4--8d x 02 44d x 02 Stud to Double Top Plate 390 165 245 Stud to Sill Plate 245 165 225 ror Sr i Incn = Z5.4 mrn, 1 IDS = 4.45 N. 'Refer to Figure 6a for overall dimensions of the RSP4 plate connector. 3Tabulated allowable loads must be selected based on duration of load as permitted by the applicable building code. 'Tabulated allowable loads have been increased for wind or earthquake loading. No further increase is allowed. Allowable loads must be reduced when other load durations govern. °Refer to Figure 6b and 6c for connection configurations. 5Fi load direction is parallel to plate, and FZ load direction is perpendicular to plate. 0 0. 0 0. I I 411z a FIGURE 6a—RSP4 STUD PLATE CONNECTOR DIMENSIONS F1 F2 FIGURE 6b—RSP4 INSTALLATION: FIGURE 6c—RSP4 INSTALLATION: STUD TO DOUBLE TOP PLATE STUD TO SILL PLATE U.S. PATENT 6,697,725 se 1 incn = Z5.4 mm, 1 IDS = 4.45 N. ulated allowable uplift loads have been increased for wind or earthquake loading no further increase allowed. Reduce loads when other durations govern. :n cross -grain bending or cross -grain tension cannot be avoided, mechanical reinforcement to resist such forces should be considered. Sill Plate allowable uplift loads, all round nail holes in the connector must be filled with the specified quantity and type of nails. Double Top Plate allowable uplift loads, all round and triangular nail holes the tie connectors must be filled with the specified quantity and of nails. SSP DSP SSP Installation: DSP Installation: U.S. Patent U.S. Patent Single Stud to Sill Plate Double Stud to Double Top Plate 7,065,932 065,932 71366,973 7,366,973 FIGURE 7—SSP/DSP STUD PLATE TIES Page 11 of 11 - ESR-2613 I Most Widely Accepter �, ,`l Trusted - TABLE 8—HGT HEAVY GIRDER TIEDOWN CONNECTORS"2 MODEL NO JHGTCONNECTOR WIDTH (W) DISTANCE BETWEEN ; THREADED RODS- (on center) (inches) FASTENERS (QuantltyType) ALLOWABLE UPLIFT - LOADS6Q Co=16 __ _ Threaded Rod' ' To Multi ply Truss: ,. IHGT-2 35/1g 53/4 2j/." Dia: 16-10d 10,345 IHGT-4 69/1s 9 2—s/e" Dia. 16-10d 11,395 inch = 25.4mm,1- Ibs = 4.45 N. 'The HGT connector can accommodate top chord slopes from minimum 3:12 (14°) to maximum 8:12 (34°) and are provided with crescent washers for sloped top chord installations. 2AII�elements of the tie -down assembly (multi -ply trusses, vertically aligned wood studs/posts, and the full -height threaded rods) must be designed to resist applied loads. 3The HGT-2, HGT-3, and HGT-4 connector attaches to the heel joint of a two-ply, three-ply, and four -ply wood truss, respectively, where each ply Mckness is nominal 2 inches. "When the HGT-3 is used with a two-ply truss, shimming is required, and the shimming material must be similar (thickness and grade of lumber) as the truss member material. Additionally, the entire assembly must be designed by a registered design professional to act as one elated allowable loads must be selected based on duration of load as permitted by the applicable building code. uplift loads have been increased for wind or earthquake loading with no further increase is allowed. Reduce loads when other load ions govern.. height threaded rods are shown in Figure 8 for illustration purposes only, as one method of transferring the design load from the HGT Bctor to the foundation. The threaded rod material specifications must be specified by the registered design professional. LBP %-Inch washers must be installed on top of each crescent washer. LBP washers and crescent washers are required. Crescent err, are supplied with the connector. LBPs/e washers are available from Simpson Strong -Tie Company, and are 2-inch square by 9/e4-inch galvanized steel washers with a center bolt hole to accommodate a 5/e-inch diameter threaded bolt1rod. HGT-2 (HGT-3 and HGT-4 similar) Install two IBPsib washers on top of each crescent washer (total four W washers) for wood Installation. All washers and" crescent washers are required. Crescent washers are supplied. Typical HGT-3 Installation with full height threaded rod. The design of the threaded rod, including any necessary hardware or shrinkage compensating devices, is outside the scope of this report. FIGURE 8—HGT HEAVY GIRDER TIEDOWN CONNECTOR