HomeMy WebLinkAboutENERGY EFFICIENCY CODEi
FORM R405-2017�
FLOR-IDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNN THE GRAND CARLTON
Builder Name: WYNNE BUILDING COPR.
�������
Street: �� („�Q n�
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Ov
89
Owner: f •WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Lucie �����
�I
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2)
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of -,units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms', 2
d. N/A
R= ft2
1
5. Is this a worst case? Yes
10. Ceiling Types (1446.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft2
Condition d floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(I41.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sgl, U=0.54 101.25 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC-'
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weig ted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
'sqft.)
a. Electric
Cap: 40 gallons
8. Floor Typels (1445.5 Insulation Area
EF: 0.970
a. Slab -Op -'Grade Edge Insulation R=0.0 1445.50 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 48.03
PASS
Total Baseline Loads: 48.08
I hereby certify that th'p plans and specifications covered by
Review of the plans and
4TftE Spg1,
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
cllo�with
the Florida Energy Code.
PREPAR D B
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
1-Iry
with the Florida Energy Code.
COD WF 4¢�
OWNER/�l
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE i SPY
4/4/2018 1125 AM ' EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405�-2017
i
PROJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1446
Lot #
Owner Na e: WYNNE BUILDING CROP
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Naml e: WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:'
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V
Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number
Name
Area Volume
1
Entire House
1446 11568
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
BEDROOM
301 2408 No 0
1
1 Yes
Yes
Yes
2
WIC
63 504 No 0
1 No
Yes
Yes
3
M.BATH
56 448 No 0
1 Yes
Yes
Yes
4
KITCHEN
192 1536 Yes 0
1 No
Yes
Yes
5
BATH
45 360 No 0
1 Yes
Yes
Yes
6
BEDROOM 2
204 1632 No 0
1
1 Yes
Yes
Yes
7
ENTRY
55 440 No 0
1 Yes
Yes
Yes
8
LAUNDRY
42 336 No 0
1 Yes
Yes
Yes
9
GREAT/DINING
488 3904 No 0
1 Yes
Yes
Yes
FLOORS
#1
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1
Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
301 ft2
----
0 1
0
2
Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
----
0 1
0
3
Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
____
0 1
0
4
Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft2
----
0 1
0
5
Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ft2
----
0 1
0
6Slab-On-Grade
Edge Insulatio
BEDROOM 2 32.2 ft 0
203.5 ft2
----
0 1
0
7Slab-On-Grade
Edge Insulatio
ENTRY 7 ft 0
55 ft2
____
0 1
0
4/4/2018 11
35 AM EnergyGauge® USA 7 FlaRes2017 Section R405.4.1
Compliant Software
Page 2 of 5
FORM R405-2017
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
1 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
i
0
42 ft2
----
0
1
0
1 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
----
0
1
0
ROOF
Roof
v
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
1 # Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
I
11 Gable or Shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
i
ATTIC
V I# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
11 Full attic Vented
150
1446 ft2
N
N
I
CEILING
�# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
11 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
i
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
I
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
i
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
I
WALLS
I Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Below
_ 1 NE=1>SW Exterior Concrete Block - Ext InsdHEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
2 SW >NE Exterior Concrete Block - Ext InsiMEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3 NW -SE Exterior Concrete Block - Ext Ins&EDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
4 SW I>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext InfiEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
_ 7 SE=>NW Exterior Concrete Block - Ext ImUDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext InfiffDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW=?NE Exterior Concrete Block - Ext InfiffDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
10 SE=NNW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=?NE Exterior Concrete Block - Ext InsLllAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
13 NE=>;SW Exterior Concrete Block - Ext InsGREAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.6
0
4/4/2018 11:35 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017-
i
DOORS
# Ornt
Door Type Space
Storms U-Value Width
Ft In
Height
Ft In
Area
l 1 SE=>NW
Insulated ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V #1 Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SI= 3 Metal
2I SW=>NE 4' Metal
3I SE=>NW 7 Metal
4I NE=>SW13 Metal
5 NW=>SE14. Metal
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in
0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in
0.54 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
0.54 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
0.55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
�1 315 ft
315 ft2
24 ft 8 ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehpuse . Proposed ACH(50) .000356
1349.6 74.09 139.34 .2598
7
I
HEATING SYSTEM
System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electriic Heat Pump/ Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1� Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType Location
EF Cap Use SetPnt
Conservation
• �11 Electric
I '
None Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FkC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
One None
ft2
4/4/2018 9'1:35 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
' I '
FORM R465-2017
DUCTS
/
--- Supply
----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
325 ftZ
Attic
85 ftz
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin Jan
Feb
f
Mar
f
A r
May
X Jun X Jul
Aug�Xl
Se
[ ]
Oct
Nov
Dec
Heating XJan
X� Feb
X� Mar
Apr
May
f Jun 4 Jul
[ ] Au
rl
SeP
[ ]
Oct
Nov
H
Dec
Ventin [ Jan
I
[ Feb
IX Mar
[x
A r [
Ma
[ Jun [ Jul
[ ]] Au
Se
[Xj
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
I
Heating (WEN)
AM
66
66
66
66
66 68
68
68
68
68
68
68
1
PM
68
68
68
68
68 68
68
68
68
68
66
66
'I
I
4/4/2018 11:35 AM
'I
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 5 of 5
2017 -;AIR CARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
.AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Projelct Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
I
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/a tic
The air barrier in an dropped ceiling/soffit /soffit shall be aligned with
y pp g g
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
I
and doors
skylights and framing shall be sealed.
Rim joists)
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors i
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including,
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls.'
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
i a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spacers.
Recessed,ighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
'
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
`
Batt insulation shall be cut neatly to fit around wiring
-'
;
and plumbing in exterior walls, or insulation that on
jg
installation readily conforms to available space shall
extend behind piping and wiring,
Shower/tub!
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box o I
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
f sprinklers
sealed in a manner that is recommended by the manufacturer.
E
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilings
a. " a—it—i1 uwNc�uvu U1 ivy wcuib widll ue m auuarOanue wan ine provisions Oi Ila.-4UU.
4/4/2018 11:35 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
1
FORM R1 05-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
FT. PIERCE, FL,
1. New construction or existing
i
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windowll ** Description
a. U-Factor: Sgl, U=0.54
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55
SHG6, SHGC=0.25
c. U-Factor: N/A
SHG('.
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0
192.00 ft2
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1446.00 ft2
1446
b. N/A
R=
ft2
c. N/A
R=
ft2
Area
101.25 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
40.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.8 SEER:15.00
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A - R=
c. N/A i'- R=
ft2
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
34.8 HSPF:8.50
3.832 ft.
0.250
Area
14. Hot water systems
1445.50 ft2
a. Electric
Cap: 40 gallons
EF: 0.97
ft2
b. Conservation features
ft2
None
15. Credits
Pstat
I certify thai this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: (V-S&6z
Address of New Home: ���� City/FL
D WE
*mote: I This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certifies Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/4/2018 11:35 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1