Loading...
HomeMy WebLinkAboutREVISION PLANDesign Parameters 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category I. -2-Basic Wind -&peed; fable 1609C, State ofFlorida Debins Region & Basic Wind Speed, Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed, VOLT= 160 MPH Exposure Category, Paragraph 1609.4.3 : C Applicable Codes, Regulation and Standards 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and Specifications for Aluminum Structure, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2010 Edition 3. ASCE 7 10_ _ General Notes 1. The contractor shall verify all dimensions prior to construction 2. All work shall comply with all local and regional ordinances. 3. Any deviation from this plan shall be reviewed by the engineer of record and is subject to approval. Specifications The following specifications are applicable to this projects 1. Where concrete specification are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable. 1.1. Concrete shall conform to ASTM C94 for following components: 1.1.1. Portland Cement Type 1, -ASTM C 150 1.1.2. Aggregate - Large Aggregate 3/4" max - ASTM C 33 1.1.3. Air entraining +/- 1%-ASTM C 260 1.1.4. Water reducing agent - ASTM C 494 1.1.5. Clean Potable water 1.1.6. Other admixture not permitted 1.2. Metal accessories shall conform to: 1.2.1. Reinforcing Bars - ASTM A615, grade 60 1.2.2. Welded wire fabric - ASTM A185 1.3. Concrete slump at discharge per chute not less then 3" or more than 5". Water added after batching is not permitted. 1.4. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2 and 3 including hot weather recommendation: 1.5. Moist cure or polyethylene curing required. 1.6. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. 1.7. All aluminum components embedded within concrete shall be coated with e bituminous paint or epoxy. 1.8. Fiber reinforced concrete per ASTSM C1116 is an acceptable alternative to 6X6 W1.4/W1.4 WWF. 2. Aluminum extrusions shall be 6005 T5 Alloy. 3. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plate to ASTM B633, or stainless steel series "300". 4. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from end 24" on center or #12 screws 6" from end 12" on center. 5. Screened enclosures containing swimming pools shall comply with the applicable requirements of FBC R4501.17 Residential Swimming Barrier requirements. 6. Door location shall be determined by contractor in the field. 7. When installing pavers over concrete slab or footing which are supporting aluminum members, such as continuous screen tracks or upright, the anchors must extend past the pavers and reach proper embedment into the underlying foundation. 8. All flashing and waterproofing shall be provided by the contractor. 9. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. 10. Vinyl and acrylic panels shall be removed when wind speeds exceed 75mph Foundation Design: Existing 8"x8" Thickend Edge 4" Slab on Grade Existing concrete. No additional concrete footing is required to resist the loads impose( by the proposed construction if the existing footing is in sound condition, free from structural cracking, spalling, or other deterioration. Roof Type Screen Size Full Mansard 18/14 ALUMINUM MEMBER DIMENSIONS HOLLOW SECTIONS SELF MATING BEAM (SMB) THE PORCH FACTORY BEAM IPFB) 2x2: 2"x2"x0.046" 2x4SMB: 2"x4"x0.044"x0.100" 3.75PFB: 2x3.76"x0.050° 2x 3: 2"x3"x0.050" 2x5SMB: 2'x5"x0.050"x0.100" 5.75PFB: 2x5.76"x0.055" - 4: 2"x4°x0.050" 2x6SMB: 2"x6"x0.D50"x0.120° COLUMNS 2x 5: 2"x5°x 0.050" 2x7SMB: 2"x7"x 0.D57"x0.120' 2x8SMB: 2x8" x 0.072" x 0.124" 2 x 9 SMS: 27x9"x0.072"x 0'124" 3x3: 3"x3°x 0.125` 4x4: 4"x4"x0.125" 6x6: OPEN BACK SECTIONS 1 x2: P'x2"x 0.040" 2 x 106MB: 2"x I W4.092' x 0.398" 6"x6'x0.125" 1 x 3: t" x 3" x 0.045" MINIMUM FASTENER EDGE DISTANCE: 10 KB: KNEE BRACE MINIMUM FASTENER SPACING: 314° RC: REC. CHANNEI SNAP SECTIONS 2 x 2 6nap: 2° x 2" x 0.045" CONCRETE SCREW ANCHOR: SHEET MATEL SCREWS (SMS) : 2 x 3Snap: 2"x3°x0.050" SIMPSONTITEN HD OR EQUIVALENT ITW BUILDER OR EQUIVALENT 2x 46nap: 2"x 41x 0.0461 s NOTE: THIS DRAWING IS FoR iLLUSTRATNE PURPOSES. DRAWING NOT TO SCALE. USE DIMENSIONS GIVEN. CABLE BRACING MAY TERMINATE AT SLAB IN DIFFERENT LOCATION. MAINTAIN ANGLE PER DETAIL. DC1tE RECEIVED JUL 2 6 „319 ST. W4910, C-;4untyr Permitting tx2 00 O � v® j $ � oo� 00 cc - oaauoauua 0 k�q"ED to County LL V L ^^O (L i 043 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC ti d G O to C IL U � � tfJ cc d -1 3 2 co -� °'aOccooCO) v O �O a SHEET rl