-- wrightsoft° Project Sumlmary Entire House Job: Date: By: QUICK CALCS, INC. 317 ST. LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796. Email: QUICKCALCS@/\OL.COM; For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL p Notes: �� \✓��S ��\ � - Weather: Winter Design Conditions db 42 OF Ib 70 OF TD 28 OF Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration I Method Construction quality Fireplaces rea (ft2) Air (ft3) Air changes/hour Equiv. AVF (cfm) Fort Pierce, FL, US Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data Ratelswing multiplier n 0.95 Equipmenf sensible load 24753 Btuh Simplified Latent Cooling Equipment Load Sizing Average 0 Structure 3203 Btuh Ducts 231.8 Btuh Central vent (0 cfm) 0 Btuh Heatingg . Cool' (none) 1446 1446 Equipment latent load 5521 Btuh 12511 12511 0.45 0.23 Equipment total load 30274 Btuh 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25H BC536A*030 AHRI ref 7914585 iency 8.5 HSPF ing input ing output 34600.Btuh @ 47°F ).erature rise 27 OF al air flow 1160 cfm, :)w factor 0.049 cfm/Btuh pressure 0.50 in H2O e thermostat. =. Icity.balance'point = 32 °F� = 7 kW, Output = 23009 Btuh, 100 AFUE Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 -Btuh Latent cooling 10440 Btuh Total cooling 34800, Btuh. Actual air flow 1160 cfm Airflow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load Sensible heat ratio 0.83- ..Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -�- wrightsoft` Right -Suite® Universal 201717.0.14 RSU08101 2017-Apr-11 09:29:38 ... uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJS Fronf Door faces: FI L E C ®PY Page 1 -1- wrightsotRight-J® Worksheet Job: Entire House Date: By QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,1OL.COM 1 I Room name Entire House BEDROOM 2 Exposed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft' 297.0 ft' 1 Ty Construction LI-value Or HTM Area ftt Load Area (ft) Load number Btuh/ftMF ( ) z (Btuhlft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A40cs - 0.143 n. 4.00., 2.66 503 465 -1862 1184 72 ' 72 288 183 4A5 tom 0.770 n 21.56 . 19:31.. 38 0 . 815 730 : 0 0 :0 0 13A4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 ' D 1Aclom 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 WA 13A-4ocs 0:143 'se 4.00 2.55 34 34 136 86 0 0 0 0 Vdl 13A-4ocs 0.143 s 4.00 2.55 360 353 1414 899 216 _ 216 865 550 1A c1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 -G 13A-4ocs 0.143 w 4.00 2.55 310 237 949 603 104 .72 288 183 IA-clorn 1.270 w 35.56 65.21: 32 2 1140 1770 32 2 1140 1-70 ; .4A5-2om . 0.770 w 21.56 19.31 41 41 880 788 : 0 - '. 6 ..:0 .. � .. 0 P I 12C-0sw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 0 C , ';16A 30md 0.032. - t):90 2.32 1446 1446 ., 1295 .. 3354 297. 297: 266 689 F 1 22Prtpl 0.989 - 27.69 ado 1446 166 4325 0 297 .. 49 1357 0 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 16 12 a)i Infiltration 2867 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less external load Less transfer 0 0 0 0 0 0 Redistribution 0 0 0 0 0 0 14 15 Subtotal ., . , '. Duct loads. 17848 .17520 5053 4925 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 23503 - 26056 6653 7325 Ai, required (cfm) 1160 1160 28 3281. 326 Of wrightsoft- Right -Suite@ Universal 2017 17.0.14 RSU08101 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: 2017-Apr-11 09:29:38 Page 1 - +- virrightsoft, RighW@ Worksheet Date: Entire House : . QUICK CALCS, INC. By. 317 ST. UCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS al OL.COM 1 Room name WIC KrrCHEN 2 E)gposed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room i2oom dimensions area 6.0 x 9.0 ft 54.0 ft2 1.0 x 172.0 ft 172.0 ftz 7y Construction U-value Or HTM Area (ft z) Load Area (ftz) Load number (Btuh/ftz-T) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 L r;:4A52orri,: 1344661 . 13A-4ocs 0143 `0.770 0.143 n: ;-n' a 4 00 21.56 4.00. 2:55 1931: 2.55 0 0 0 0 0 0 • 0 '_ 0 0 - 0 0; 0 . :0 0 0 0 : 0 0 0 A 0 0 0 0 11 W{ 1A-clom 11DO =13A-46cs 13A-4ocs 1A-c1om 13AAocs 1A-alom 1.270 0.390 0.143 0.143 1.270 0.143 1.270 a a se s s w - w 35.56 10.92 4.00 4.00 35.56 4.00 35.56 87.29 11.31 255 2.55 34.77 2.55 55.21 0 .0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0' 0 0 0 0 0 0 0 .0 0 0 -0 0 0 0 0 0 0 .0 0 0 0 0 1V�1 -G P C 4A5 tom . 12C-Qsw 16A;30md`: .0.770 0.091 ;0:032.,. w - - 21.56 2.55 .10.90 19.31 1.28 2.32 0- 0 54..• 0 0 54 0 0 48.- 0. 0. . ' 125. 0 64 172.. 0 64 • .:172' 0 163 154 0 82 399 F 22Prtpl 0.969 27:69 0.00 54 0 0 0 172. • 0 0 0 6 c)�AED excursion -9 -170 En,velopeloss/gain 48 117 317 311 12 a)I Infiltration b), Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 14 15 Less ex(emal load Liss transfer Redistribution Sdbtotal Duct.loadS ;' .:' 32% 49% 0 0 0 48 15 • 0 0 0 117 57 32% 49% 0 0 0 317 100 0 0 0 2311 1126 Total room load Air• required (cfm). .. 64 3 174 .81 418 21 3437 153 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -- wrightsoft, 2017-Apr-11 09:29:38 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ..uick Calcs1Documents%THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - - wrightsi ft' Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@!AOL.COM 1 i Room name BATH BEDROOM 2 2 Exposed wall 5.0 It 34.2 ft 3 Room height 8.0 It heat/cool 8.0 It heat/cool 4 Room dimensions 9.0 x 5.0 It 1.0 x 203.5 It 5 Room area 45.0 ft2 203.5 112 y Construction Ll-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhlft2--°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool ' 6 1 13A-0ocs t ; 6143 : n. 4-.00 : 2;55 40 - 40 160 ! 102 - 128 - 128 ; 513 326 +4Ar2om .. 0.770 n. 21.56 ' 19:31 0 0 .. 0 : 0- 0 ` -`0 �1�G 13A-4ocs 0.143 a 4.00 2.55 0 0 0. 0 80 56 225 143 1A-clom 1.270 a 35.56 87.29 0 0 0 .0 24 2 848 2082 ' '-D 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 1 .13A-4ocs 0:143 . se .4.00 2.55 0 0 0 . 0 34 34 136 86 TL 13A4ocs 0.143 s 4.00 255 0 0 0 0 32 32 128 81 1A-clom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 1 13A4ocs .0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om: .1270 w 35.56 55;21 0 0 0 0 60 0 0 I .4A5-20m ' .0.770 -` w. -:21:56 . .' 19:31 ' 0 0 0 0 0 .0 . 0 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 0 , 0 0 q 16XMffid= . , - 0.032 - 0.90 2.32 45; 45 40 . 104 .0 : 204 :: . 204 ':182 ' ; ' 472 F 22A tpl 0.989 - 27.69 0.06 45 5 138 0 204 34 _ 946 0 6 c)AED i excursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . I 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 1 Appliances/other 0 0 SuliItotal Qines 6 to.13) 425 214 3571 3496 Less external load Less transfer 0 0 0 0 0 0 0 0 Redistribution 0 0 0 0 14 Suib otal 425 214 3571 3498 15 Duct loads 32% 49% 135 104 32% 49% 1131 1704 Totm load 560 318 4702 5203 Air required (cfm) 28 14 232 232 .�, wright'st3 t' Right -Suite® Universal 2017 17.0.14 RSU08101 .�C�P. uick Calcs\DocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: 2017-Apr-11 09:29:38 Page 3 + -i virlightsoft' Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 3 Exposed wall Room height 6.0 ft 8.0 ft heat/cool 47.0 ft 9.8 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 526.0 ft 526.0 ft2 i y Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh1ft1m°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 I 13A�ocs. -' 4A5-2om . ' . 13A-4ocs : 0143 0.770 0.143 : : n . m - a 4.00 21;56 4.00 -2,55 19.31 2.55 0 0 0 • 0 0 0 0 0 .. 0 0 0 ; : 255 38 0 ., 21Z; ,' _ 0 0 869 ':815 0 552 ; :730 0 11 I 1Aclom 11D0 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 . WI llW 13A4ocs 13A-4ocs 1Aclom 0143 0.143 1.270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 0 48 0 0 48 0 0 192 0 0 122 0 0 0 0 0 0 0 0, 0 0 0 0 0 1--1� P C 13A46cs 1Ac1om 4A5 tom 12C-0sw .16AMmd. - 0.143 1.270 0.770 0.091. 0i032 w w ; w - ' = 4.00 35.56 21.56 2.55 0.90 2.55 65.21 19:3t 1.28 ' 132 0 0 0 56 ' 42 0 0 , 0 56 42 0 0 , . 0 143 38 0 0 , 0 72 :. 97 206 0 ,' 41 0 - 526 165 :0 . 41 0 "'526 66.1 0 880 0 . 471 420 0 . ..:788 0 ..1220 _ F 22A tpl 0.989 - 27.69 0.00 42 6 166 0 _ _ 526 47 1302 0 6 c)AED excursion _222 668 Envelope loss/gain 539 270 4897 4379 12 a).' b) Infiltration Room ventilation 104 0 28 0 997 0 273 0 13 Intemal gains: Occupants @ 230 Appliances/other 0 0 0 2 460 0 Subtotal (lines 6 to 13) 643 298 59941 5112 14 15 Less wdemal load Less transfer Redistribution- . Subtotal Duct loads 32% 49% 0 0 0 643 204 0 0 0 298 145 32% 49% 0 0 0 5994 1899 0 0 0 5112 2490 1Totbl room load AIr required (cfm) 846 42 443 20 1 7892 390 7602 338 Calculations approved byACCA to meet all reM wcightsoft' Right -Suite@ Universal 2017 17.0.14 RSU08101 A I uick CialcsXDocuments\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N 2017-Apr-11 09:29:38 Page 4 - wrightsoft' Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946•Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER M. BATH 2 E)posed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heaticool 8.0 ft heat1cool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 50.0 ft2 56.0 ftz' Ty Construction U-value Or HTM Area (ft') Load Area (ft) Load number (Btuh/ft2L-°F) (Btuhlftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AAogs 0143 '%n :4.00 . 2;55 8 . • 8 32 - 20 . 0 0 0 .0 -G 4A5-2om .0.770 n 21.56 ` 19.31 ' . ' -' b -0. 0 . -0 ` 0 0 - 0. 0 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 �13A-4ocs 12 IA-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 w 13A400s 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 W YLG 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 13A-4ocs 0.143 w 4.00. 2.55 0 0 0 0 0 0 0 0 I c1om _ 1:270 w 35.56 55.21 0 0 0- 0 0 0 0 0 05-tam . .0.770 w 21.56. 19.31 0. 0 0 0 0 0 0 0 1 P 12C-0sw 0.091 - 2.55 1.28 72 72 183 92 6 0 0 0 G 16A 30md - 0:032 - 9.90 2.32 50 50 45 . 116 56 56 50 . 130 F 22A-tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 222 0 6 c)AED excursion -39 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 inteinal gains: Occupants @ 230 0 0 0 0 1 Appliances/other 0 0 Subtotal Qines 6 to 13) 913 529 885 516 Less external load Less transfer 0 0 0 0 0 0 0 0 14 Redistribution Subtotal 0 0 0 0 15 Duct loads 32% 49% 913 289 529 258 32% 49% 885 280 516 251 I Total room load Air required (cfm) 0 122 787 1166 768 59 35 58 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed Fr" wrightsoft- ACCta Right -Suite® Universal 2017 17.0.14 RSU08101 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N I 2017-Apr-11 09:29:38 Page 5 ' II +wrightsofto Duct System Summary oa e: i Entire House By: j QUICK CALCS,INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL I External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actualf air flow Total effective length (fEL) Heating. 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft I 1 Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl . Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH I h 560 28 14 0.364 4.0 Ox 0 VIFx 22.4 115.0 8t1 BEDROOM 2 h 4702 232 232 0.360 7.0 OxO VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox 0 VIFx 31.8 135.0 st2 BEDROOM-8 h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER! h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 GREAT/DINING-A 'KITCHEN h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 c 3437 21 153 0.379 6.0 Ox0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox 0 VIFx 23.3 115.0 st1 M. BATH A h 768 58 34 0 0 Ox 0 VIFx 0 0 WIC c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Name Trunk Htg Clg Design Veloc Diam H x W Duct Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx SO st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx A wrightsoft@ 2017-Apr-11 09:29:38 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 .. quick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) . (in) Opening (in) Math Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx t wri htsoft° 2017-Apr-1109:29:38 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ...uick Calcs\Documents\THE.GRAND CARLTON-1446.rup Calc = MJB Front Door faces: N