HomeMy WebLinkAboutBLOWER DOOR TEST CERTIFICATIONPlanning Development Services
Building Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34902
Phone: 772-462-2165 Fam 772-462-6643
BLOWER DOOR TES u FORM
Clouse Infiltration Test Certification
1�609 o5gz
RECEIVED
AUG 2 0 7019
Permitting Department
St. Lucie County
Prescriptive and Performance Method �
BY
Date: �' �� g Permit #: � r� 0 � - D j `� � fit L lcie CcunV
Contractor: ^ e.
Job Ad�rress: U, W `( 2 7-
Construction: New Construction •- Complete Existing - After Addition
House Wiltration Test Results SLC Climate Zone 2
CFM (56) = t `(' 6 19 Test Date: � L
Volume = 376o
ACH (50) = CFM (50) sc 60 / Volume = Mec apical Ventilation required less than 3 ACH
Passing results must be g; ACH (50) or less Mass ( ) Fall
Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
Fac, PZQGS dGnttai
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Compariy P1915 Rio Vista Drive, Ft. Pierce, FL 34949
Company Name: Pro -Duct Services Address: .
I herebyi certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirerpents in accordance with Section R402.4.1.2 Climate Zone 2.
1 Z1191,. A,
Signature:
Printed (Name:
Martin Klein
License/Certification #: 5061633