The truss
MiTek U
based on i
Truss De:
My licer
Florida C
I Truss,Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
g Conditions):
Code: FBC2017/TPI2014 Design Program: MiTek 20/20 8.1
ode: ASCE 7-10 Wind Speed: 165 mph Design Method: MWFRS (Directional)/C-C hybrid Wind ASCE 7-
)ad: 37.0 psf Floor Load: N/A psf
kage includes 27 individual, dated Truss Design Drawings and 0 Additional Drawings.
seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
to 61G15-3f.003, section 5 of the Florida Board of Professional Engineers Rules.
Pal# Truss Name Date No. Seal# Truss Name Date
Tff3569629
a
3/22/18
T13569630
a1
3/22/18
T13569631
a2
3/22/18
T13569632
a3
3/22/18
T13569633
a4
3/22/18
T13569634
a6
3/22/18
T13569635
b
3/22/18
T13569636
bh7
3/22/18
T13569637
gra
3/22/18.
T13569638
grb
3/22118
T13569639
grc
3/22/18'
T1356964.0
11
3/22/18
T13569641
12
3/22/18
T13569642
13
3/22/18
T13569643
14
3/22/18
T13569644
15
3/22/18
T13569645
16
3/22/18
T13569646
18
3/22/18
T13569647
la
3/22/18
113569648
lb
3/22/18
T13569649
lc
3/22/18
T13569650
K15
3/22/18
T13569651
k18
3/22/18
T13569652
k1a
3/22/18
T13569653
kjb
3/22/18
26 T13569654
27 T13569655
wing(s) referenced above have been prepared by
, Inc. under my direct supervision
parameters provided by Chambers Truss.
i Engineer's Name: Finn, Walter
renewal date for the state, of Florida is February 28, 2019;
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSUfPI 1. These designs are based upon parameters
shown (e.d., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek
customers file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verity applicability of design parameters and properly incorporate these designs
into the overall building design per ANSI/TPI 1, Chapter 2.
2 3/22/18
mv4 3/22118
FILE, COrY
`:,% J'eR P P
/3'` P.•GEN•'' ti4, 1
No 22839
•. • ylr
�-0 ;
:-A STATE OF :• 4JZ
Walter P. Flnn PE No22839.
w rok OSA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610 March 22,2018
1 of 1 Finn, Walter
Job ,
Truss
Truss Type
Qty
Ply
THE ROYAL E
T13569629
ml 1324
A
COMMON
10
1
Job Reference (optional)
Chambers I russ, I
4x5 =
ron Fierce, I-L
8-4-0 12-1
8-4-0 4-i
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-E812cj_pyFwe2wzxxmviDnbMhHlkJ4QEFIPAOizYQkg
17-6-0 22-1-0 26-8-0 35-0-0 $6-0-Q
4-7-0 4-7-0 4-7-0 8-4-0 1-0-0
Scale = 1:59.3
4.00 12 4x5 =
6
2x3 I 25
3x6 5
3x4:- 4
3
24
17 16 15
2x3 11 5x6 WB=
3x8 =
26 2x3 11
7 3x6 C
8 3x4
9
28 29 14 13 12
3x8 = 2x3
5x6 WB=
27
4x5 =
12-11-0
22-1-0
2" 0 35-0-0
N-0
8-4-0
4-7-0
9-2-0
4-7-0 8-4-0
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.59
Vert(LL)
0.33 14-15 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.68
Vert(CT)
0.64 14-15 >652 240
BCLL 0.0
Rep Stress Incr
YES
WB 0.63
Horz(CT)
OA3 10 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 169 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4
SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-1-13 oc purlins.
BOT CHORD 2x4�
SP M 30
BOT CHORD
Rigid ceiling directly applied or 4-10-7 oc bracing.
WEBS 2x4�SP No.3
OTHERS 2x41 SP No.3
REACTIONS. (lb/size) 2=1399/0-8-0, 10=139910-8-0
Max Harz 2= 223(LC 8)
MaIx Uplift 2=-775(LC 10), 10=-775(LC 10)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2 j3=-3404/2226, 3-5= 2807/1885, 5-6=-2801/1990, 6-7= 2801/1990, 7-9=-2807/1885,
9110=-3404/2226
BOT CHORD 21,17=-1946/3218, 15-17=-194613218, 14-15=1116/2053, 12-14=1946/3188,
10-12=-1946/3188
WEBS 6j14=-598/1034, 7-14=-252/246, 9-14=-702/541, 6-15=-598/1035, 5-15= 253/246,
3115=-701 /541
NOTES-
1) Unbalanced roo live loads have been considered for this design.
2) Wind: ASCE 7-1.0; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B--151t; L=50ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Extehor(2) 12-8-6
to 17-6-0, Interior(1) 22-1-0 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) 100.Olb AC unit oad placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechankcal connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift at
joint 10.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33810
Date:
March 22,2018
® WARN NG - Ve�fy design parameters and READ NOTES ON TH S AND INCLUDED MITEK REFERANCE PAGEMII-7473 rev. f0/=015 BEFORE USE.
Destgh valid far e only with MiTe;;� cohnectors. This aestgi Is based only upon parametets shown, and is for an EridWtduai txtlidlhg component, not �^
q Truss system. Beore use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
"fxillding design. acing Indicated is io prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is aiways require for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the 6904 Parke East Blvd.
fabrication, stora e, delivery, erection and bracing of trusses and truss systems, seeANSI/IPII Cuo19yCIF1®do, OSB89 and BCSI Building Component So%fV /nloirnaHOnavaflable from Truss Plate Inslilute, 218 N. Lee Sheer, Suite 312, Alexandria, VA 22314. Tampa, FL 33610
Job .
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569630
m11324
Al
SPECIAL
9
1
Job Reference (optional)
cnamoers I russ, Inc., r-on rlerce, rr.
I
of 2
d) G
3x5 =
o.t JU s 1v1ar 1 1 zU 10 ,vu 1 er, u,uusuies, u1c. 1 nu mul ee Ua: 1 u:eo eu 10 rays r
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-iLJQp3?RjZ2Vg4Y8VTQym_8Tnhas2XsNUP8jY9zYQkf
13-7-8 17-6-0 23-11-12 26-9-10 35-0-0
5-11-8 3-10-8 6-5-12 2-9-14 8-2-6 0-0
Scale = 1:60.3
5x8 MT18HS =
4.00 12
6
2x3 I 2x3 I I
3x6 22 5 23 5x6 WB
7
3x4 4 8 2x3
3 9
14
2x3 I I
24
12
26 6x10 MT18HS =
25
13
5x12 =
2.00 12
23-11-12 35-0-0
3x12 =
'1
7-8-0 15-1 1-8 10-4-4
11-0-4
Plate Offsets (XY),-
[2:0-1-2 Edqel [8:0-3-0 Edge1 [10:0-1-15,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.89
Vert(LL) 0.80 12 >525 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.94
Vert(CT) -1.39 12-13 >302 240
MT18HS 2441190
BCLL 0.0
Rep Stress Incr YES
WB 0.62
Horz(CT) 0.37 10 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 159lb FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4
SP M 30 TOP CHORD Structural wood sheathing directly applied.
BOT CHORD 2x4
SP M 30 BOT CHORD Rigid ceiling directly applied.
WEBS 2x4
SP No.3 `Except` WEBS 1 Row at midpt 6-12
6-12:
2x4 SP M 30
OTHERS 2x4
SP No.3
REACTIONS. (lb/size)
2=1349/0-8-0, 10=1349/0-8-0
Maio
Harz 2=-223(LC 8)
Max
Uplift 2=-825(LC 10), 10= 825(LC 10)
FORCES. (lb) - MI
Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3309/2433,
K.
3-5=-2581/2012, 5-6= 2548/2113, 6-7=-5337/4002, 7-9=-5302/3868,
9-
10=5702/4143
BOT CHORD 2-l14=-2151/3113,
13-14=-2151/3113, 12-13=-1450/2202, 10-12=-3809/5431
WEBS 3-14=0/265,
3-13=-813/590, 5-13=-269/317, 6-13=-317/567, 6-12=-2362/3388,
7-12=-298/368,
9-12=-405/352
NOTES-
1) Unbalanced roof
live loads have been considered for this design.
2) Wind: ASCE 7-10;
VIIIt=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 12-8-6, Exterior(2) 12-8-6
to 17-6-0, 1 terioI(1) 22-3-10 to 31-2-6 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
TII
3) All plates are M j20 plates unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between tqe
bottom chord and any other members, with BCDL = 10.Opsf.
6) Bearing at joint's)
10 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify
capacity of bearing
surface.
7) Provide mechanical
connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 10.
1
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING - Verify
design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MI1-7473 rev. 1010312015 BEFORE USE.
Design valid for usle
only with Mllek:0 connectors. This design Is based only upon parameters shown, and Is for on Individual building component not
a truss system. Be
ore use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design.
acing Indicated is to prevent buckling of Individual truss web and/or chord members only. Addilional temporary and permanent bracing
MiTek"
Is always require for stability and to prevent collapse with possible personal Injury and property tlamage. For general guidance regarding the
fabrication, stora e, delivery, erection and bracing of trusses and truss systems, seeANSUIPII Qualify Ci feria, DSB-89 and BCSF Building Component
6904 Parke East Blvd.
Sa/etrinlonna/fonavailabie from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job •
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569631
ml 1324
A2
SPECIAL
1
1
Job Reference (optional)
chambers Truss, Inc.,
1-0•Q
FOR Nlerce, FL
8-0-1
13-7-8
8., od s iv,d, , r cu, o Iva, en Industries, Inc. , nd ,v,ar « 09. , d.4d �� � o Faye ,
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-iLJQp3?RjZ2Vg4Y8VTQym_SWghZL2VrNUPBjY9zYQkf
, 16-0-0 19-0.0 23-11-12 26-9-9 35-0-0 16-0-0
1
0-
8-0-1
5-7-7
2-4-8 3-0-0
4-11-12 2-9-13 8-2-7 0-
Scale = 1:62.3
4.00 12
5x6 = 4x4 =
5 6
3x8
5x10 %
7 5x6
34
N
89ri
22
t
23
2
12 10 t1 NII ao
m1
13
6x10 MT18HS
O
14 3x10
15
2x3 I
5x6 =
3x12
3x5 =
2.00 F12
8-0-1
13-7-8
19-0-0
23-11-12 35-0-0
8-0-1
5-7-7
5-4-8
4-11-12 11-0-4
Plate Offsets (X Y)-,
[2:0-1-2 Edge] [4:0-2-12 0-3-01[4.0-0-0
0-1-12] [8:0-3-0 Edge] [8:0-0-0 0-1-121 [9:0-3-2 0-0-0] [10:0-1-15 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.70
Vert(LL) 0.75
12 >559 360
MT20
2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.98
Vert(CT) -1.02
12-21 >412 240
MT18HS
244/190
BCLL 0.0 '
Rep Stress Incr YES
WB 0.75
Horz(CT) 0.37
10 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 160lb
FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4
SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-4-8 oc pudins.
BOT CHORD 2x4
SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4
SP No.3
WEBS
1 Row at midpt 7-13
REACTIONS. (lblsize) 2=1349/0-8-0, 10=1349/0-8-0
Max Horz 2=-205(LC 8)
Max Uplift 2=-825(LC 10), 10= 825(LC 10)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3315/2113, 3-5=-2515/1641, 5-6= 2524/1699, 6-7=-2672/1734, 7-9=5246/3199,
9-I10=-5687/3567
BOT CHORD 2-45=-1849/3111, 14-15=-1849/3111, 13-14= 1217/2314, 12-13= 2804/5025,
10-12= 3257/5414
WEBS 3-[1 5=0/300, 3-14=-954/692, 5-13=-206/561, 6-13=857/632, 7-13=-2796/1678,
7-p2=-1082/1957, 9-12=-479/463
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-1p; Vult=165mph (3-second gust) Vasd=128mph; TCDL11.2psf; BCDL=3.Opsl; h=12ft; B--15ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6
to 36-0-0 zone,cI C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between t I bottom chord and any other members.
7) Bearing at joint(s� 10 considers parallel to grain value using ANSIIrPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 10.
Walter P. Finn PE No.22838
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING - Veri
ly design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. 10/0"IS BEFORE USE.
v
Design valid for uSIa
only with MITei0 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before
building design.
use, The building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
Indicated Is to buckling of Individual truss web and/or chord members only. Additional Temporary and permanent bracing
MiTek°
Is always require
acing prevent
for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricallorL stora
e, delivery, erection and bracing of trusses and truss systems, seeANSt/7PI1 QualOy Cdletla, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety/nformoHoegvallable
from Truss Plate Institute, 218 N. Lee Sheet, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job •
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569632
m11324 I
�A3
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 20i 8 MI Tek industries, Inc. Thu Mar 22 09:1 u:za zut o rage r
I D:_kfiGCA6bx7j2Sy1 H DXFw7ye3KX-AXto1 P?3UsAMH E7K2AxBJCghg4vany8Xi3uH4bzYQke
1-0- 8-0-1 14-0-0 21-0-0 23-11-12 26-9-10 35-0-0 6-0-
0- 8-0-1 5.11-15 7-0-0 2-11-12 2-9-14 8-2-6 0-
5x6 =
.— 17;-�--
�1
6
4x6 =
axa
8-0-1 1 13-7-8 , 21-0-0 1 23-11-12 35-0-0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0 `
BCDL 10.0
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x41SP No.3
SPACING-
2-0-0
Plate Grip DOL
1.25
Lumber DOL
1.25
Rep Stress Incr
YES
Code FBC2017ITP12014
REACTIONS. (Ib/size) 2=1349/0-8-0, 8=1349/0-8-0
Maz Horz 2=-181(LC 8)
Max Uplift 2=-825(LC 10), 8=-825(LC 10)
Scale=1:61.3
N
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TC 0.69
Vert(LL) 0.72 10 >582 360
MT20 244/190
BC 0.98
Ved(CT)-0.9810-19 >427 240
MT18HS 244/190
W B 0.74
Horz(CT) 0.35 8 n/a n/a
Matrix -MS
Weight: 158lb FT=O%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-5-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3286/2122, 3-4=-2556/1711, 4-5=-3161/2095, 5-6=-3304/2150, 6-7= 5214/3232,
7-B_ 5695/3643
BOT CHORD 2-3=-185313079, 12-13=-1853/3079, 11-12=-1338/2410, 10-11= 2B26/4982,
8-�0= 3331/5422
WEBS 3-II 3=0/293, 3-12=-854/595, 4-11= 480/959, 5-11=-360/724, 6-11= 2280/1355,
6- 1 0=-1 118/1934, 7-10=-530/515
NOTES-
1) Unbalanced roofllive loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50111; eave=6ft; Cat.
11; Exp C; Encl., GCpj=0.18; MW FRS (directional) and C-C Exterior(2) -1-" to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Exterior(2) 31-2-6
to 36-0-0 zone;C,-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between tf�e bottom chord and any other members.
7) Bearing at joint(s) 8 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 8.
0
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MREK REFERANCE PAGE MII-7473 rev. 101031 015 BEFORE USE.
Design valid for u e only with tv {Te tO connectors. This design Is bored only Upon parameters shown, and Is for an individual building component, hot
a truss system. Be ore use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
Is to buckling Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
building design. acing Indicated prevent of
Is always require for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, stora e, delivery, erection and bracing of trusses and truss systems, seeAN9VWJ1 CuaBlyWeda, DSB-89 and SCSI BuBdIRg Component
6904 Parke East Blvd.
Safety Informanbnovallable from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Job •
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569633
m11324
A4
SPECIAL
1
1
!
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
�1
6
6-5-8
4.00 F12
b.i3u s Mar 11 GUlS MI I ek indu5ere5, 4iu. i nu Mar zc 0a iu.ov cv ro rage i
I D:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-ei RAEIOhFAI DvOi W cuTQrPDsdUF? W O—gxjdgd 1 zYQkd
17-8-4 23-0-0 4-11-12 26-9-9 35-0-0 $6-0-Q
5-8-4 5-3-12 0-11,1 2-9-13 8-2-7 i-O-U
Scale = 1:61.3
5x6 = 3x4 = 5x8 —
2x3 11
4 5 6 7
14 13 3x4 =
3x6 = 3x4 = 5x6 = 2.00 12
3x12 =
Plate Offsets (X Y)-- [2'0-0-6 Edge] [6:0-4-0 0-2-3] [9:0-1-15 Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl Ud
PLATES
GRIP
TOLL 20.0
Plate Grip DOL 1.25
TO 0.67
Vert(LL)
0.73 11-12 >572 360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.96
Vert(CT)
-0.98 11-20 >429 240
MT18HS
244/190
BOLL 0.0
Rep Stress Incr YES
WB 0.77
Horz(CT)
0.36 9 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 160lb
FT=0%
.LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-5-6 oc pudins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (Ib/size) 2=1349/0-8-0, 9=1349/0-8-0
Max Harz 2=157(LC 9)
Max Uplift 2=-825(LC 10), 9= 825(LC 10)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3367/2256, 3-4=-3093/2069, 4-5=-2645/1853, 5-6=-3425/2347, 6-7=-5165/3301,
7-8=-5219/3301,8-9=-5704/3714
BOT CHORD 214= 2000/3170, 13-14=-1488/2537, 12-13= 2065/3480, 11-12=-2440/4196,
9-1 1=-3399/5431
WEBS 3-P 4_ 429/415, 4-14=-323/584, 4-13=-142/386, 5-13= 1125/697, 5-12=-141/467,
6- 2=-861/437,6-11=-1145/2016,8-11=-542/518
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 31-2-6, Extehor(2) 31-2-6
to 36-0-0 zone;C,-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between ttie bottom chord and any other members.
7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 9.
I
Walter P. Finn PE No.22838
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22.2018
I
® WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valld for usie only with IVIITeRry connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Be ore use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
Is to buckling Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTeiC°
building design. acing Indlcafed prevent of
Is always require for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, stora e, delivery, erection and bracing of trusses and truss systems, seeAMSWI1 GualByCrBelm, DSO-89 and BCSI Building Component
6904 Parke East Blvd.
Safety lntonnatbaovailable from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job •
Truss
Truss Type
city
Ply
THE ROYALE
T13569634
ml1324
A6
HIP
1
1
Job Reference (optional)
cnamoers I russ, Inc., Ton Tierce, t-L
1-0-0 6-715
4.00 12
2x3
3
o i
4x5 =
tf.13u s mar 11 zU16 MI I eK Inausifles, Inc. I nu Nlar zz uU:1 U:31 zui tl rage 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-6w?YS51 KOUR4XYHiAb_fOdlOkuf9FzMpANN09UzYQkc
0 i25-0-0 28-4-1 35-0-0 $6-0-Q
3-8-0 3-4-1 6-7-15 0-1
5x8 = 2X3 11 2x3 11 5x8 =
4 23 24 5 25 26 6 27 28 7
16 15 14
3x4 = 4x6 = 3x4 =
13 12 11
3x4 = 4x6 = 3X4 =
Scale = 1:60.3
2x3 i
8
N
n
(i
9 10 W
6
35-0-0
4x5 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.71
Vert(LL) 0.60
11-13 >424 360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.71
Vert(CT) -0.78
13 >328 240
BCLL 0.0
Rep Stress Incr
YES
WB 0.31
Horz(CT) 0.11
9 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MS
Weight: 153 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4
SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc puffins.
BOT CHORD 2x4
SP M 30
BOT CHORD
Rigid ceiling directly applied or 4-6-3 oc bracing.
WEBS 2x4
SP No.3
REACTIONS. (Ib/ ize) 2=1118/0-8-0, 14=379/0-8-0, 9=1201/0-8-0
Ma C Horz 2= 133(LC 8)
Max Uplift 2— 692(LC 10), 14=-219(LC 10), 9= 739(LC 10)
M Grav 2=1118(LC 1), 14=454(LC 19), 9=1206(LC 20)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-D= 2600/2341, 3-4=-2215/1960, 4-5= 2527/2290, 5-6= 2527/2290, 6-7— 2527/2290,
7-8=-2531/2224, 8-9=-2880/2572
BOT CHORD 2-,16=-2074/2444, 14-16= 1569/2065, 13-14=-1968/2527, 11-13=-1833/2382,
9- 1=-2290/2707
WEBS 3-' 6=-495/599, 4-16=-206/347, 4-14=-541/820, 5-14=-526/591, 6-13=-234/311,
7-j13=-182/282, 7-11=-355/492, 8-11=-444/551
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-1P; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft eave=6tt Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) -1-0-0 to 16-9-7, Interior(1) 16-9-7 to 18-2-9, Exterior(2) 18-2-9
to 25-0-0 zone;C- C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between toe bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 692 lb uplift at joint 2, 219 lb uplift at
joint 14 and 739 lb uplift at joint 9.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cent 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M!I-7473 rev. 1010312015 BEFORE USE.
Design valld tot ule only with MITek® connectors. This design Is based only upon patometers shown, and Is for an individual building component not
a truss system. Be ore use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Mew
Is always required, for stability and to prevent collapse with possible personal Injury and property damage, For general guidance regarding the
fabrication. storage, dellvery, erection and bracing of trusses and truss systems, seeANSl VII CuaNyCi fede, DSB-89 and BCSI Budding Component
6904 Parke East Blvd.
Safety InformafloFpvallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569635
m11324
B
COMMON
3
1
Job Reference (optional)
cna
CI
!kb
12n-1 •
I6
6-11-0
6-11-0
Plate Offsets (X Y)-
[2:0-2-10 Edge] [4:0-2-10 Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.37
Vert(LL) 0.10
5-8 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.33
Vert(CT) -0.13
5-8 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.12
Horz(CT) 0.01
4 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 47 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4
SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4
SP M 30
BOT CHORD
Rigid ceiling directly applied or 7-7-1 oc bracing.
WEBS 2x4
SP No.3
REACTIONS. (lb/size)
4=51010-8-0, 2=568/0-8-0
Max
Harz 2=93(LC 9)
Max
Uplift 4=-292(LC 10), 2= 377(LC 10)
FORCES. (lb) - MI
. Comp./Max. Ten. - All forces 250 (lb) or
less except when shown.
TOP CHORD 2-V-967/954,
3-4= 966/952
BOT CHORD 2-�=-785/883,
4-5-7851883
WEBS 3
=-84/315
NOTES-
1) Unbalanced roof
2) Wind: ASCE 7-1
II; Exp C; Encl., I
shown; Lumber 1
3) This truss has b(
4) ` This truss has I
will fit between If
5) Provide mechani
joint 2.
ve loads have been considered for this design.
; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft L=5011; eave=6ft Cat.
Cpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions
DL=1.60 plate grip DOL=1.60
?n designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
:en designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
bottom chord and any other members.
al connection (by others) of truss to bearing plate capable of withstanding 292 lb uplift at joint 4 and 377 lb uplift at
Walter P. Finn PE No.22639
MiTek USA, Inc. FL Cori 6634
69D4 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING -Verify
design parameters and READ NOTES ON THIS AND INCLUDED MTTEK REFERANCE PAGE M8.7473 rev. 1010312015 BEFORE USE.
Design valid for u
e only with MITekID connectors. This design Is based only upon parameters shown, and is for on Individual building component, not
a truss system. Before
use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek7
Is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, stora0e, delivery, erection and bracing of trusses and truss systems, seeANSUIPII QualifyCrBeda, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Sa/etir/nlonna6bnavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Oty
Ply
THE ROYALE
T13569636
m11324
BH7
BOSTON HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
�1
6
8.l30 s Mar l l 2Ol8 MI 1 eK Industries, lnc. I nu mar zz u9:1u:33 zui ti rage 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-217Jsn3aY5homrR5H007T2rL7iN—jgG6dhsUEMzYOka
15-6-0 21-6-0
13-6-01 -0 0 17-6-0 19-6.0 21-0-0 23-6-0 25-6.0 26-0-0 35-0-0 6-0-
2-D-0 -6- 1-6-0 2-0-0 2-0-0 1-6-0 -6- 2-0-0 2-0-0 2-6-0 7-0-0 1-0-0
Scale=1:62.6
4.00 12 5x6 =
12 14 16
21-0-0
35-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.72
Vert(LL) 0.51
32-33 >826 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.56
Vert(CT) -0.67
32-33 >628 240
BCLL 0.0
Rep Stress Incr YES
WB 0.48
Horz(CT) 0.14
28 n/a n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MS
Weight: 208lb FT=0%
LUMBER-
BRACING -
TOP CHORD 2x4
SP M 30 TOP CHORD
Structural wood sheathing directly applied or 3-8-6 oc puffins.
BOT CHORD 2x4
SP M 30 BOT CHORD
Rigid ceiling directly applied or 4-6-1 oc bracing.
WEBS 2x4ISP
No.3 JOINTS
1 Brace at Jt(s): 11, 18, 15, 7, 23
REACTIONS. (lb/size) 2=1349/0-8-0, 28=1349/0-8-0
Max Horz 2=-223(LC 8)
Max Uplift 2=-825(LC 10), 28=-825(LC 10)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3392/2640, 3-4=-1213/956, 4-8=-1157/946, 8-9= 1145/979, 9-12=-1122/1028,
12-14=-1125/1090, 14-16— 1124/1089, 16-19=-1121/1028, 19-22=-1145/979,
22-26=-1157/946, 26-27= 1214/956, 27-28= 3393/2641, 3-5=-2373/2046, 5-7=-2376/2050,
7110= 2376/2050, 10-11=-2376/2050, 11-13=-2376/2050, 13-15= 2376/2050,
15-17=-2376/2050,17-18=-2376/2050,18-20=-2368/2046,20-23= 2368/2046,
23-25=-2368/2046, 25-27= 2364/2041
BOT CHORD 2-135=-2358/3190, 33-35=-2360/3166, 32-33=-2652/3448, 30-32— 2361/3167,
213-30= 2358/3191
WEBS 3-35=0/284, 27-30=0/285, 3-33=-317/378, 18-33=-466/474, 27-32=-312/353,
14-15=-405/437
NOTES- I
1) Unbalanced roof;live loads have been considered for this design.
2) Wind: ASIDE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft B=45fh L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 3-9-10, Interior(1) 3-9-10 to 10-8-9, Extedor(2) 10-8-9
to 17-6-0, Interior(1) 24-3-7 to 31-2-6 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ` This truss has peen designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between tt1'e bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 28.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
Walter P. Finn PE No.22639
fib Tek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
Mar(•-h 99 9fl1R
A WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MllekO connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must vedfy the applicability of design parameters and properly Incorporate this design Into the overall
building design. F racing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required, for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication• storage• delivery, erection and bracing of trusses and truss systems, seeANSVWI1 QualffyCrCeda, DSB-89 and BCSI Bulldlgg Component
6904 Parke East Blvd.
Safety rntamalloigvallable from Truss Plate Institute, 216 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job '
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569637
ml1324
GRA
SPECIAL
1
1
Job Reference (optional)
c:namoers i russ, in
1-0-0
0
2
o�
ron Fierce, rL
4-1-8
o.,ouarv,a, ,, cu,o rvnien,uuuau,ca, u,�. uw mm cc vo.,v.���..,u ,ayo,
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-WUhh473CJPpfO??HrkXMOFNfJ5n3SO?GsLb2mozYQkZ
5-7-3 8-2-13 , 9-8-8 , 13-10-0 14-10-0 ,
1-5-11 2-7-9 1-5-11 4-1-8 1-0-0
2.37 12
4x4 =
4x10
19 4 20
4.00 12 3 —
3x4 =
12 23 11
2x3 3x4 =
4x4 =
21 5 22 64x10
IE
10 24 9
3x4 = 2x3 II
Scale = 1:26.6
4-1-8 5-7-3
8-2-13
9-8-8 13-10-0
4-1-8 1-5-11
2-7-9
1-5-11 4-1-8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) 0.08
11 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.32
Vert(CT) -0.10
10 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.06
Horz(CT) 0.03
7 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 58 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4
SP M 30
TOP CHORD
Structural wood sheathing directly applied or 5-4-7 oc pudins.
BOT CHORD 2x4
SP M 30
BOT CHORD
Rigid ceiling directly applied or 7-0-4 oc bracing.
WEBS 2x4
SP No.3
REACTIONS. (Ib/size)
2=770/0-8-0, 7=770/0-8-0
Max
Harz 2= 65(LC 6)
Max
Uplift 2=-523(LC 8), 7=-523(LC 8)
Me,
Grav 2=787(LC 17), 7=787(LC 18)
FORCES. (lb) - Max.
Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1798/1192,
3-4=-1761/1197, 4-5=-1724/1169, 5-6= 1761/11go, 6-7=-1798/1137
BOT CHORD 2-il
2=-1083/1685, 11-12= 1082/1692, 10-11= 1112/1724, 9-10= 102411692,
7-9=
1028/1685
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vuit=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., 6Cpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 523 Ito uplift at joint 2 and 523 lb uplift at
joint 7.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 63 lb down and 114 lb up at
4-1-8, 85 Ito down and 124 lb up at 5-0-0, 113 lb down and 146 lb up at 5-7-3, 60 lb down and 129 lb up at 5-11-0, 60 lb down and
129 lb up at 7-11-0, 113 lb down and 146 lb up at 8-2-13, and 85 lb down and 124 lb up at 8-10-0, and 63 lb down and 139 lb up at
9-8-8 on top chord, and 6 lb down and 7lb up at 4-1-8, 18 lb down and 15 lb up at 5-0-0, 33 lb down at 5-7-3, 39 lb down at 5-11-0
,39 lb down at 7-11-0, 33 lb down at 8-2-13, and 18 lb down and 15 lb up at 8-10-0, and 6 lb down and 7 lb up at 9-8-8 on bottom
chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Siandard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-4=-54, 4-5— 54, 5-6=-54, 6-8=-54, 13-16=-20 Walter P. Finn PE No.22838
Concentrated Loads (lb) MIT& USA, Inc. FL Cart 6834
Vert: 3=�(B) 4=-64(B) 5=-64(B) 6=7(13) 12= 6(B) 11= 35(B) 10=-35(B) 9— 6(B) 19=-28(B) 20=-60(B) 21=-60(B) 22=-28(B) 6904Parke East Blvd. Tampa FL 33610
23= 18(6) 24=-18(B) Date:
March 22,2018
® WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/03f2015 BEFORE USE. �'
Design vaild for u only with MITckV connectors. This design Is based only upon patatneters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall A
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek`
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storaj e, delivery, erection and bracing of trusses and truss systems, seeANSVW11 QualifyCdleft DSB-89 and SCSI SuOding Component 6904 Parke East Blvd.
Satetylntormatlenavallable from Truss Plate Institute, 218 N. Lee Sheet, Suite 312, Alexandria. VA 22314. Tampa, FL 33610
Job, I
Truss
Truss Type
Qty
Ply
THE ROYALE
I
T13569638
ml1324
GRB
SPECIAL
1
1
{
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09A0:35 2018 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-?hE3HS4g4ixV?9aUPR2bYTwmXV6MBjtP5?LbIFzYQkY
t1.0-Q 5-0-0 10.3-0 15-6-0 21-6-0 26-2-0 1 28-1-0 35-0-0 Q6-0-Q
0- 5-0-0 5-3-0 5-3-0 6-0-0 4-8-0 1-11-0 6-11-0 y-o-d
6
Plate
sb it as lb as 5x6
3x4 = 2x3 II 3x4 = 3x6 = 3x4 =3x6 = 3x4 = 3x4 =
15-6-0
6-7-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
Well
Ud
TCLL 20.0
Plate Grip DO
1.25
TC 0.41
Vert(LL)
0.11 17-18
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.38
Vert(CT)
-0.14 17-18
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.53
Horz(CT)
0.03 10
n/a
n/a
BCDL 10.0
Code FBC2017fFP12014
Matrix -MS
LUMBER
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4{ SP M 30
WEBS 2x46SP No.3
PLATES GRIP
MT20 244/190
Weight: 146 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-4-6 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 4-15
REACTIONS. All bearings 0-8-0.
(Ib) - Max Horz 2=96(LC 7)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-536(LC 8), 15=-846(LC 8), 14=-555(LC 8), 10=-314(LC
8)
Max Grav All reactions 250lb or less atjoint(s) except 2=787(LC 17), 15=1322(LC 1), 14=927(LC 1), 10=506(LC
14)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2 j3=-1773/1106, 3-4=-1406/944, 4-6=-304/595, 6-7=-304/595, 7-8=-304/595,
829= 702/344, 9-10=-719/323
BOT CHORD 2118=-962/1659, 17-18=-958/1675, 15-17=-843/1406, 14-15= 595/429, 12-14=-158/622,
10-12=-196/636
WEBS 3 i18=0/331, 3-17=-297/158, 4-17=0/362, 4-15=-2076/1313, 6-15=-505/480,
7 i14=-431/408, 8-14=-1063/625, 8-12=-115/265
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft L=50ft; eave--6f ; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 536 lb uplift at joint 2, 846 lb uplift at
joint 15, 555 lb uplift at joint 14 and 314 lb uplift at joint 10.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 257 lb down and 341 lb up at
5-0-0, 100 lb down and 129 Ib up at 7-0-12, 100 lb down and 129 lb up at 9-0-12, 100 lb down and 129 lb up at 11-0-12, 100 lb
down and 129 lb! up at 13-0-12, 100 lb down and 129 lb up at 15-0-12, 100 lb down and 129 lb up at 17-0-12, and 100 Ib down and
129 lb up at 19-0-12, and 100 lb down and 129 lb up at 21-1-4 on top chord, and 83 lb down at 5-0-0, 39 lb down at 7-0-12, 39 lb
down at 9-0-12,j39 lb down at 11-0-12, 39 lb down at 13-0-12, 39 lb down at 15-0-12, 39 lb down at 17-0-12, and 391b down at
19-0-12, and 39 lb down at 21-1-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of
others. !
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
-Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22.2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MREK REFERANCE PAGE 11,1II-7473 rev. 10/03/2015 BEFORE USE.
Design valid for u�e only with lvRITekV connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, sforape. delivery, erection and bracing of trusses and truss systems, seeANSUIPH CuatHyClffeffa, DSO-89 and SCSI Bulldlrtp Component
6904 Parke East Blvd.
Safety Infoana/Ionavallable from Truss Plate institute, 218 N. Lee Street. Suite 312, Alexandria VA 22314.
Tampa, FL 33610
Job,
Truss
Truss Type
City
Ply
THE ROYALE
T13569638
m11324
GRB
SPECIAL
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
8.130 s Mar 11 2018 Mi I eK Industries, Inc. I nu Mar 22 09:10:35 2015 Page 2
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-?hE3HS4g4ixV?9aUPR2bYTwmXV6MBjtP5?LblFzYQkY
I
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-8=-54, 8-9= 54, 9-11=-54, 19-22=-20
Concentrated Loads (lb)
Vert: 3-160(F) 18= 45(F) 25=-60(F) 26=-60(F) 27=-60(F) 29=-60(F) 30=-60(F) 31=-60(F) 32=-60(F) 33=-60(F) 36=-13(F) 37= 13(F) 38=-13(F) 39=-13(F) 40=-13(F)
41= 13(�) 42= 13(F) 43=-13(F)
I -
® WARNING - Ver
l
fy design parameters and READ NOTES ON THIS AND INCLUDED MI EK REFERANCE PAGE MI1-7473 rev. 10/032015 BEFORE USE.
for Individual building
Design valld for use
a truss system. Before
only with MlTek8 connectors. This design Is based only upon parameters shown, and Is an component riot
use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design.
Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required
for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage,
dellvery, erection and bracing of trusses and truss systems, seeANSVW11 QualifyOftedo, DW-89 and BCSI Bufld/ng Component
6904 Parke East Blvd.
Safety IntolmaNd.novallable
from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job'
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569639
ml 1324
GRC
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:10:37 2018 Page 1
ID:
_kfiGCA6bx7j2Syl HDXFw7ye3KX-x3Mgi864cKBDFTksWs53du?1 EJjDfZLiYJgiN7zYQkW
I 8-0-0 3-8.0 17-6-0 2114-0 7-0-0 35-0-0 -0-28 $Q
-0 3-10-0 3-0-00 8-0-0 5 5 8-0-0
�1
6
16 33 15 14 34 35 36 37 13 38 12 39 11
3x5 = I 2x9 II 3x6 = WO= WO = 3x6 = 2x3 II 3x5 =
35-0-0
1:60.3
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
I
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code F802017/TP12014
CSI.
TC 0.71
BC 0.67
WB 0.79
Matrix -MS
DEFL. in (loc) I/deft Ud
Vert(LL) 0.22 11-22 >999 360
Vert(CT) -0.31 13-14 >830 240
Horz(CT) 0.05 9 n/a n/a
PLATES GRIP
MT20 244/190
MT18HS 244/190
Weight: 157 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-5-6 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-9-3 oc bracing.
WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 3-14,
5-14
4-14,7-13: 2x6 SP No.2
REACTIONS. (lb/size) 2=412/0-8-0, 14=3582/0-8-0, 9=1192/0-8-0
Max Horz 2=-109(LC 6)
Max Uplift 2=-299(LC 8), 14=-2133(LC 8), 9=-764(LC 8)
Max Grav 2=423(LC 17), 14=3582(LC 1), 9=1194(LC 18)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-377/225, 3-4=-1093/1954, 4-5= 1093/1954, 5-7=-1943/1220, 7-8= 1943/1220,
8-b=-2776/1671
BOT CHORD 2-1[16=-154/317, 14-16= 160/350, 11-13=-1475/2624, 9-11 =-1 46412591
WEBS 3-116— 200/679, 3-14=-2514/1528, 4-14— 641/586, 5-14=-2674/1707, 5-13= 1124/2080,
7- 3=-592/548, 8-13=-760/483, 8-11=-201/684
NOTES-
1) Unbalanced roofilive loads have been considered for this design.
2) Wind: ASCE 7-1p; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft B=45ft L=50ft; eave=6ft Cat.
11; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between tfie bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 299 lb uplift at joint 2, 2133 lb uplift at
joint 14 and 764 lb uplift at joint 9.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 182 lb down and 312 lb up at
8-0-0, 107 lb down and 173 lb up at 10-0-12, 107 lb down and 173 lb up at 12-0-12, 107 lb down and 173 lb up at 14-0-12, 107 lb
down and 173 Iblup at 16-0-12, 107lb down and 173 lb up at 16-11-4, 107lb down and 173 lb up at 18-11-4, 1071b down and 173
Ib up at 20-11-4; 107 Ib down and 173 lb up at 22-11-4, and 107 Ib down and 173 Ib up at 24-11-4, and 182 lb down and 312 lb up
at 27-0-0 on topichord, and 411 Ib down and 242 lb up at 8-0-0, 79 lb down and 1 lb up at 10-0-12, 79 lb down and 1 lb up at
12-0-12, 79 lb down and 1 lb up at 14-0-12, 79 lb down and 1 lb up at 16-0-12, 79 lb down and 1 Ib up at 16-11-4, 79'Ib down and
1 lb up at 18-11 4, 79 lb down and 1 lb up at 20-11-4, 79 lb down and 1 lb up at 22-11-4, and 79 lb down and 1 lb up at 24-11-4,
Walter P. Finn PE No.22838
and 411 lb down and 242 lb up at 26-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility
MiTek USA, Inc. FL Cert 6834
of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
6904 Parke East Blvd. Tampa FL 33610
Date:
LOAD CASE(S) Standard March 22,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valld for Usle only with MITekV connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the appllcabllity of design parameters and properly Incorporate this design Into the overall
building design. 1raclnq Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required; for siabllOy and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSVWII QualifyCl9eda, DSO-89 and SCSI Building Campanent
6904 Parke East Blvd.
Safely lntamtallobavalloble from Truss Plate Institute, 218 N. Lee Street- Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job•
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569639
ml 1324
GRC
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
u.13u s Mar 11 M B MI I eK Inclusines, Inc. i nu Mar zz uun u:JA 2u1 tl rage Z
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-x3Mgi864cKBDFTksWs53du?1 EJjDfZLiYJgiN7zYQkW
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-8=-54, 8-10=-54, 17-20=-20
Concentrated Loads (lb)
Vert: 3=i126(B) 6=-107(B) 8=-126(B)15= 50(B)16=-411(B) 11= 411(B) 12— 50(B) 23=-107(B) 25=-107(B) 26=-107(13) 27=-107(B) 28— 107(B) 29— 107(B)
30=-107(8) 32=-107(B) 33=-50(B) 34=-50(B) 35=-50(B) 36=-50(B)37= 50(B) 38=-50(B) 39=-50(B)
® WARNING - Ve 1y design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE.
Design valid for u e only wifh rvifiek0 connectors. This design is based only upon paraineteis shown, and Is for an Individual building component not
�
a truss system. Be ore use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Ihacing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Addilional temporary and permanent bracing
MiTek°
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrlcatlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSM11 QualtlyCXeda, DSB-89 and BCS1 Bugd/ng Component
6904 Parke East Blvd.
Saletvintormaflo avallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job'
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569640
m11324
J1
MONO TRUSS
2
1
Job Reference (optional)
cnamoers I russ, Inc., I -on Nierce, I-L
tm;1u s mar r1 zul6 MI I eK inaustnes, inc. i nu mar zz ua:i u:sl zui rs
3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL)
-0.00
5
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.02
Vert(CT)
-0.00
5
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
4
rVa
n/a
BCDL 10.0 i
Code FBC2017/TP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=9/Mechanical, 2=118/0-8-0, 4=0/Mechanical
Max Horz 2=48(LC 10)
Max Uplift 3=-4(LC 7), 2=-140(LC 10)
Max Grav 3=11(LC 15), 2=118(LC 1), 4=17(LC 10)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Scale = 1:6.1
PLATES GRIP
MT20 244/190
Weight: 5 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc puriins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASIDE 7-1i0; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6fh Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has bgen designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(si for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4lb uplift at joint 3 and 140 lb uplift at
joint 2.
Walter P. Finn PE No.22639
MiTek USA, Inc. FL Cott 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING • Ve41y deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE
Design valld for Use only with MITehr Connectors. This design Is based only upon pmometers shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSy1PI1 AualByCdleda, DSB-89 and BCS1 Bu6d(gg Component
6904 Parke Easl Blvd.
Safety lnfotmaBonavaliable from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandrla. VA 22314.
Tampa, FL 33610
Job'
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569641
ml 1324
J2
MONO TRUSS
4
1
Job Reference (optional)
Chambers Truss, Inc.,
Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:10:38 2018 Page 1
ID:_kfiGCA6bx7j2Sy l H DXFw7ye3KX-PG W C W U6jNdJ4scJ34ZclA5YLMjCrOCzrnzZFvazYQkV
-1-g-0 2-0-0
1-0-0
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017/TPI2014
3x4 =
CSI.
DEFL.
in
(loc)
I/defl
Ud
TC 0.18
Vert(LL)
-0.00
7
>999
360
BC 0.07
Vert(CT)
-0.00
7
>999
240
W B 0.00
Horz(CT)
-0.00
3
n/a
n/a
Matrix -MP
LUMBER- I BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3 BOT CHORD
REACTIONS. (lb/size) 3=37/Mechanical, 2=141/0-8-0, 4=23/Mechanical
Max Harz 2=67(LC 10)
Max Uplift 3= 28(LC 10), 2= 136(LC 10), 4=-3(LC 7)
Max Grav 3=42(LC 15), 2=141(LC 1), 4=31(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Scale = 1:7.8
PLATES GRIP
MT20 244/190
Weight: 8 lb FT = 0%
Structural wood sheathing directly applied or 2-0-0 oc puffins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 13=45ft; L=50ft; eave=6tt; Cat.
II; Exp C; Encl., GCpi=0.18: MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has bgen designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint
2 and 3 Ib uplift at joint 4.
Walter P. Finn PE No.22639
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARN/NG - —fly design parameters and READ NOTES ON THIS AND INCLUDED MfIEK REFERANCE PAGE M11-7473 rev. 101=015 BEFORE USE.
Design valld for use only w8h MiTek connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
���
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building deslgn. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
NUTeV
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrication, storage, delivery, erection and bracing of Trusses and truss systems. socANSUM11 QualByWader, DSB-69 and SCSI BUBdLV Component
Safety lnlormallonavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job•
Truss
Truss Type
Qty,
Ply
THE ROYALE
T13569642
mi 1324
J3
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc.,
Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:10:38 2018 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-PGwCwU6jNdJ4scJ34ZcIA5YLMjBHOCzrnzZFvazYQkV
-1-0-0 3-0-0
1-0-0
3x4 =
Scale = 1:9.4
3-0-0
3-0-0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Verl(LL) 0.01
4-7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.17
Vert(CT) -0.01
4-7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 11 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc purfins.
BOT CHORD 2x4l SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (ib/size) 3=64/Mechanical, 2=173/0-8-0, 4=37/Mechanical
Max Horz 2=85(LC 10)
Max Uplift 3=-54(LC 10), 2= 147(LC 10), 4=-4(LC 10)
Max Grav 3=70(LC 15), 2=173(LC 1), 4=50(LC 3)
FORCES. (lb) - MI . Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=501t; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has b `eren designed for a 10.0 psf bottom chord live load nonconcurrent With any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint
2 and 4 lb uplift At joint 4.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 8834
$904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERANCE PAGE MI1-7473 rev. 10/03/2015 BEFORE USE
Design valid for USe only With MITOWWD connectors. This design Is based only upon parameters shown, and is for an Individual building component, riot
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse With possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems seeANSWI1 GualllyCdteda, DSB-49 and BCSI BuOdLV Component
6904 Parke East Blvd.
Safety Intomratlonavallabte from Truss Plate Institute, 218 N, Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Joti i
Truss
Truss Type
City
Ply
THE ROYALE
T13569643
m11324
J4
MONO TRUSS
4
1
Job Reference (optional)
Chambers Truss, Inc.,
I
Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:10:39 2018 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-tSUa7g7L7xRxUmuFeH7XjJ5So6UM7eD??dJpROzYQkU
4-0-0
I'1 - -0-0 0 4-0-0
3x4 =
LOADING (psf) SPACING- 2-0-0 CSI.
TCLL 20.0 Plate Grip DOL 1.25 TC 0.39
TCDL 7.0 Lumber DOL 1.25 BC 0.37
BCLL 0.0 Rep Stress Incr YES WB 0.00
BCDL 10.0 Code FBC2017/TP12014 Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (Ib%size) 3=89/Mechanical, 2=206/0-8-0, 4=50/Mechanical
Max Horz 2=104(LC 10)
Max Uplift 3=-79(LC 10), 2= 161(LC 10), 4=-8(LC 10)
MaX Gray 3=97(LC 15), 2=206(LC 1), 4=67(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
4-0-0
DEFL. in (loc) I/dell Ud
Vert(LL) 0.02 4-7 >999 360
Vert(CT) -0.02 4-7 >999 240
Horz(CT) -0.00 3 n/a n/a
Scale = 1:11.1
PLATES GRIP
MT20 244/190
Weight: 14 lb FT = O%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-1'0; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent With any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 3, 161 lb uplift at joint
2 and 8 lb uplift at joint 4.
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33810
Date;
March 22,2018
A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev. 1010312015 BEFORE USE,
Design valid for use only Win MITekV conhectots. This design is based only upon parameters shown, and Is for an Individual building component. not
�°
a truss system. Be ore use, the building designer must verify the applicablllty of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrlcaiion, storage, delivery, erection and bracing of trusses and truss systems, seeANSlpplr Aua/ByCritedo, DSB-89 and BCS►SuBd6rg Component
6904 Parke East Blvd.
So7etylntormaHonovattable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job'
Truss
Truss Type
City
Ply
THE ROYALE
T13569644
ml1324
J5
MONO TRUSS -
11
1
Job Reference (optional)
Chambers Truss, Inc.,
Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:10:40 2018 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-Le2yKA8zuFZo6wTRC_emFWdZeWIRs5T8EH2MzSzYQkT
1-0-0
3x4 =
Scale = 1:12.7
LOADING (psf) I
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.70
Vert(LL)
0.06
4-7
>939
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.64
Vert(CT)
-0.06
4-7
>964
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 17 lb FT = 0%
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4, SP No.3
REACTIONS. fib/size) 3= 11 5/Mechanical, 2=243/0-8-0, 4=63/Mechanical
Max Horz 2=123(LC 10)
Max Uplift 3=-104(LC 10), 2=-177(LC 10), 4=-9(LC 10)
Max Grav 3=125(LC 15), 2=243(LC 1), 4=87(LC 3)
FORCES. (lb) - M . Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc puffins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 13=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., PCpi=0.18; MW FRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between tfe bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanlcal connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at
joint 2 and 9 Ib uplift at joint 4.
Walter P. Finn PE No,22639
MiTek USA, Inc. FL Cort 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March. 22,2018
® WARNING - Verhy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 101032015 BEFORE USE.
'
Design voild for u41e only with MITekV connectors. This design Is based only upon patmefers shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the appllcabfllty of design parameters and properly Incorporate this design Into the overall
building design. Ijrocing Indicated Is to prevent buckling of individual Truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always requiredlfor stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrlcaflom storage, delivery, erection and bracing of trusses and truss systems, seeANSVIPII Cua/ByCdtedo, DSB-89 and BCSI BuIldiRg Component
6904 Parke East Blvd.
SafetylnformaHoarovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job'
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569645
m11324
J6
MONO TRUSS
4
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:10:40 2018 Page 1
ID-kfiGCA6bx7j2Syl HDXFw7ye3KX-Le2yKA8zuFZo6wTRC_emFWdeEWits5TBEH2MzSzYQkT
-1-0-0 6-0-0
1-0-0 6-0-0
Scale = 1:14.3
3x4 =
LOADING (psf) SPACING- 2-0-0 CSI.
TCLL 20.0 Plate Grip DOL 1.25 TC 0.34
TCDL 7.0 Lumber DOL 1.25 BC 0.80
BCLL 0.0 Rep Stress Incr YES WB 0.00
BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP
I
LUMBER -
TOP CHORD 2x41 SP M 30
BOT CHORD 2x4l SP No.3
REACTIONS. (Ib/size) 3=142/Mechanical, 2=27510-8-0, 4=70/Mechanical
Max Harz 2=140(LC 10)
Max Uplift 3_ 129(LC 10), 2=-192(LC 10), 4=-8(LC 10)
Maio Grav 3=155(LC 15), 2=276(LC 15), 4=100(LC 3)
FORCES. (lb) - Max- Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
6-0-0
DEFL. in (loc) Well Ud
Vert(LL) 0.11 4-7 >664 360
Vert(CT) -0.11 4-7 >652 240
Horz(CT) -0.00 3 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 20 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12111; 6=45fh L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Extedor(2) zone;C-C for members and forces & MIN FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between ttie bottom chord and any other members.
4) Refer to girder(sj for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 3, 192 Ito uplift at
joint 2 and 8 lb uplift at joint 4.
Walter P. Finn PE No.22939
MiTek USA, Inc. FL Ced 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING-Vertfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 mv. 10103,2015 BEFORE USE.
Designvalid for shown, and Iss for
i Is based lity o
with lulding verify
�a
designmeters
truss systemBe ore use, the bdesignter mush the applicabiparameters d p properly Incorvidual porate a this design Icomnto he overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Mew
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSMII QualityCrIfeila, DSB-09 and BCSI Building Component
6904 Parke East Blvd.
Safety /ntonnaflohavallcNe from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Jou
Truss
Truss Type
City
Ply
THE ROYALE
T13569646
ml 1324
JB
MONO TRUSS
11
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:10:41 2018 Page 1
I D:kFvnsnOwY419ZhO_nM3lc6ylJ9g-prcKYW 9bfYhfj42dli9?okAlrw7HbYi ITxovW uzYQkS
1-0-0 8-0-0
1-0-0 8-0-0
Scale = 1:17.7
3x4
7-0-0
8-0-0
7.0-0
Plate Offsets (X Y)i- f2:0-3-14 0-1-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.61
Vert(LL) -0.14
4-7 >676 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.47
Vert(CT) -0.30
4-7 >310 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Wind(LL) 0.26
4-7 >368 240
Weight: 26 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4, SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD 2x4; SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=188/Mechanical, 2=348/0-8-0, 4=99/Mechanical
Max Horz 2=178(LC 12)
Max Uplift 3=-174(LC 12), 2= 226(LC 12), 4=-13(LC 12)
Max Grav 3=195(LC 17), 2=348(LC 1), 4=141(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 13=59ft; L=36ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-7-3, Intedor(1) 2-7-3 to 7-10-4 zone;C-C for
members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 Ib uplift at joint 3, 226 lb uplift at
joint 2 and 131b uplift at joint 4.
Walter P. Finn PE No,22839
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING - VeNIy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 101032015 BEFORE USE.
'
Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Befpre use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always requlredyfor stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
MOW
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeAN51/Ipll GualByCriteria, DSB-89 and BCS1 BuBding Component
6904 Parke East Blvd.
Safetyln/ormaBonavoilable from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job'
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569647
m11324
JA
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MITek Industries, Inc. Thu Mar 22 09:10:41 2018 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-prcKYW9bfYhfj42dli9?okAscwDBbYilTxovWuzYQkS
1-0-0 2-4-3
1-0-0 2-4-3
3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(too)
Well
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL)
-0.00
7
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.09
Vert(CT)
-0.00
7
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
LUMBER -
TOP CHORD 20 SP No.3
BOT CHORD 2x4 SP No.3
Scale = 1:8.3
PLATES GRIP
MT20 244/190
Weight: 9 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-4-3 oc puffins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=45/Mechanical, 2=150/0-8-0, 4=28/Mechanical
Max Horz 2=73(LC 10)
Max Uplift 3=-37(LC 10), 2= 139(LC 10), 4=-4(LC 7)
Ma z Grav 3=50(LC 15), 2=150(LC 1), 4=37(LC 3)
FORCES. (lb) - Mlax. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
I
NOTES-
1) Wind: ASCE 7-1;0; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 37 lb uplift at joint 3, 139 lb uplift at joint
2 and 4 lb uplift at joint 4.
Walter P. Finn PE No.22839
MfTek USA, Inc. FL Cert 6634
69D4 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/=015 BEFORE USE.
Design valid for use only vvIih MnekV connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
�
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required, for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSU►pir QualByCtBeda, DSB.E9 and BCSi Building Component
6904 Parke East Blvd.
Safety infomrahbnavallabte from Truss Plate Institute, 218 N. Lee Street, Sulte 312, Alexandria, VA 22314.
Tampa, FL 33610
Joni
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569648
m11324
JB
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 11 2ut 8 MI I etc industries, inc. I nu Mar zz 09:10:42 2018 rage
1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-H1AjIsADQspWLEdgJPgEKxjz5KNwK?yRibXT2LzYQkR
-1-2-5 5-5-11
1-2-5 5-5-11
Scale = 1:12.5
3X4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.38
TCDL
7.0
Lumber DOL
1.25
BC 0.89
BCLL
0.0
Rep Stress Incr
YES
WB 0.00
BCDL
10.0
Code FBC2017/rP12014
Matrix -MP
LUMBER -
TOP CHORD 2J SP M 30
BOT CHORD 2x4 SP No.3
DEFL, in (loc) I/defl Ud PLATES GRIP
Vert(LL) 0.10 4-7 >645 360 MT20 244/190
Vert(CT) -0.07 4-7 >898 240
Horz(CT) -0.00 3 n/a n/a
Weight: 19 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-5-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 5-0-0 oc bracing.
REACTIONS. (lb/size) 3=127/Mechanical, 2=269/0-8-0, 4=63/Mechanical
Max Horz 2=114(LC 10)
Max Uplift 3=-109(LC 10), 2_ 206(LC 10), 4— 6(LC 10)
Mix Gray 3=127(LC 15), 2=269(LC 1), 4=90(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-1 10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Comer(3) zone;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 109 lb uplift at joint 3, 206 lb uplift at
joint 2 and 6 lb uplift at joint 4.
I
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/03&015 BEFORE USE.
Design votid for uo only with MITekV connectors. This design is based only upon porameters shown, and Is for on Individual building component not
a truss system. Before use, the building designer must verify The applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabricallon, storage, delivery, erection and bracing of trusses and truss systems, seeANSW11 GuadtyClBedd, DSO-89 and BCSt Budding Component
6904 Parke East Blvd.
SoflyrntormaHonzivallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Jots
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569649
ml1324
JC
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
1-0-0
8.T 3u s mar 1 i zui a rva i ere industries, mu. i nu wim zz ua: i u:ya cv r o Faye i
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-mDj5zBArBAxNzOBOt7BTt9FC5kwg3SCawFHOanzYQkQ
3x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Well
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL)
-0.00
5
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.02
Vert(CT)
-0.00
5
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
4
n/a
n/a
BCDL 10.0
Code FBC2017ffP12014
Matrix -MP
LUMBER
TOP CHORD 2x4, SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 3=1 1 /Mechanical, 2=119/0-8-0, 4=4/Mechanical
Max Horz 2=50(LC 10)
Max Uplift 3=-6(LC 7), 2=-138(LC 10)
M I xGrav3=14(LC15),2=119(LCl),4=14(LCIO)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:6.2
PLATES GRIP
MT20 244/190
Weight: 5 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 1-1-4 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., 6Cpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 6 lb uplift at joint 3 and 138 lb uplift at
joint 2.
Walter P. Finn PE No.22639
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING - Verltydesign parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITekV connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
this design Into the
a truss system. Before use, the building designer must verify The applicability of design parameters and properly Incorporate overall
building design. Bracing Indicated Is To prevent buckling of Individual truss web and/or chord members only. Addltlonal temporary and permanent bracing
MiTek"
Is always required, for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and Truss systems, seeANSI/IPII Qua/ByClfteda, DSB-89 and SCSI SuIldltlg Component
6904 Parke East Blvd.
Safety/nfonnallonavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
city
Ply
THE ROYALE
T13569650
m11324
KJ5
MONO TRUSS
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.130 s Mar 112018 MiTek Industries, Inc. Thu Mar 22 09:10:43 2018 Page 1
ID-kfiGCA6bx7j2Syl HDXFw7ye3KX-mDj5zBArBAxNzOBOt7BTt9F9Wks?3SCawFHOanzYQkQ
-1-5-0 3-11-0 7-0-2
1 1-5-0 3-1 1-0 3-1-2
2.83 FIT
3x4 =
Scale = 1:15.7
7.0-2
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.34
Vert(LL)
0.09
4-7
>923
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.26
Vert(CT)
-0.15
4-7
>563
240
BCLL 0.0
Rep Stress incr
NO
WB 0.00
Horz(CT)
0.00
2
Na
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 23 lb FT = 0%
LUMBER- IBRACING-
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb%size) 3=194/Mechanical, 2=233/0-11-5, 4=94/Mechanicai
Max Horz 2=109(LC 8)
Max Uplift 3=-174(LC 8), 2=-191(LC 8)
Max Grav 3=198(LC 13), 2=233(LC 1), 4=133(LC 3)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girderQ for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 174 lb uplift at joint 3 and 191 lb uplift at
joint 2.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2= 54
Trapezoidal Loads (plf)
Vert: 2=0(F=27, B=27)-to-3— 95(F= 20, B=-20), 5=0(F=10, B=10)-to-4=-35(F=-8, B=-8)
Walter P. Finn PE No.22839
N%Tek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING - Vertfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valld for use only with MITekJ connectors. This design Is based only upon parameters shovm, and is for on Individual building component not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
NTTek"
Is always required, for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrlcallon, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/IPII ®uallfyCrBeda, DSB-89 and BCSI SuBdAgg Component
6904 Parke East Blvd.
Safety /nlormatlanovallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569651
m11324
KJ8
MONO TRUSS
2
1
Job Reference (optional)
Chambers Truss, [tic., Fort Pierce, FL
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
LUMBER -
TOP CHORD
BOT CHORD
WEBS
REACTIONS.
FORCES. (lb) -
TOP CHORD
BOT CHORD
WEBS
NOTES-
1) Wind: ASCE 7
11; Exp C; Encl.
2) This truss has
3) ' This truss ha.
will fit between
4) Refer to girder
5) Provide mecha
2 and 223 lb ul
6) Hanger(s) or o
2-11-0, 38 lb d
and 145 lb up
down and 31 It
up at 8-6-14 0
7) In the LOAD C
LOAD CASE(S)
1) Dead + Roof L
Uniform Loads
Vert: 1
Concentrated I
Vert: 1
6.i30siviar n2vr6rvu1enu1uubu1eb,1—.
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-EQHTAXBTyT3EaXmCRgjiOMoMG7DPoq_k9vOa6DZYQkP
11-3-0
2.83 12 3x4 % 12
ill
10
4-0-9
Scale4=
13
14
6 15
2x3 I I
3x4 =
3x4 =
5
7-2-7
11-0-12 11-3r0
7-2-7
3-10-5 0-2-4
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
Plate Grip DOL 1.25
TC 0.21
Vert(LL) 0.08
6-9 >999 360
MT20 244/190
Lumber DOL 1.25
BC 0.25
Vert(CT) -0.10
6-9 >999 240
Rep Stress Incr NO
WB 0.35
Horz(CT) 0.01
5 n/a n/a
Code FBC2017/TP12014
Matrix -MS
Weight: 44 lb FT = 0%b
BRACING-
SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puffins.
SP M 30
BOT CHORD
Rigid ceiling directly applied or 9-10-15 oc bracing.
SP No.3
size) 4=90/Mechanical, 2=465/0-11-5, 5=409/Mechanical
(Horz 2=178(LC 8)
( Uplift 4=-91(LC 8), 2= 332(LC 8), 5=-223(LC 8)
ax. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
3= 875/541
5=-535/842, 5-6=-535/842
3=-1/287, 3-5= 923/587
10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft L=50ft; eave=6ft; Cat.
GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
een designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
he bottom chord and any other members.
r) for truss to truss connections.
iical connection (by others) of truss to bearing plate capable of withstanding 91 lb uplift at joint 4, 332 lb uplift at joint
ift at joint 5.
ter connection device(s) shall be provided sufficient to support concentrated load(s) 38 lb down and 61 lb up at
wn and 61 lb up at 2-11-0, 8 lb down and 106 lb up at 5-8-15, 8 lb down and 106 lb up at 5-8-15, and 42 lb down
1 8-6-14, and 42 lb down and 145 lb up at 8-6-14 on top chord, and 31 Ib up at 2-11-0, 31 lb up at 2-11-0, 11 lb
up at 5-8-15, 11 lb down and 31 lb up at 5-8-15, and 31 lb down and 14 lb up at 8-6-14, and 31 lb down and 14 lb
bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LSE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
(balanced): Lumber Increase=1.25, Plate Increase=1.25
4, 5-7=-20
(lb)
(F=40, B=40) ll=-5(F=-3, B=-3) 12=-83(F=-42, B=-42) 13=14(F=7, B=7) 14=-21(F=-11, B=-11) 15=-50(F=-25,
Walter P. Finn PE No.22839
MTek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING -Verily
design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design Valid for
kse only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not
this design Into the
'
a truss system. Liefore
building design.I
use, the building designer must verify the applicability of design parameters and properly Incorporate overall
Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always requlydd
for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storbge,
delivery, erection and bracing of trusses and truss systems, seeANSUIPll CualltyCiNeft DSB-89 and 8CS1 BuOdhrig Companant
6904 Parke East Blvd.
Safety thlomnaflwlavailable
from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569652
m11324
KJA
MONO TRUSS
2
1
Job Reference (optional)
chambers i russ, inc., Ton Tierce, rL
2
3X4 =
0.1JV 5IVIAI I I LV 10 IVII I UM I IIUVMIICJ, 11— 111u IVIaI cc rIV' I
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-EQHTAXBTyT3EaXmCRgjiQMoML7EeovSk9vOa6DzYQkP
6-0-4
3.30 FIT
3
4
Scale = 1:13.6
6-0-4
6-0-4
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.21
Vert(LL) 0.04
4-7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.17
Vert(CT) -0.07
4-7 >974 240
BCLL 0.0
Rep Stress Incr NO
WB 0.00
Horz(CT) 0.00
2 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 20 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc puffins.
BOT CHORD 2x¢ SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (Ib/size) 3=142/Mechanical, 2=181/0-9-11, 4=69/Mechanical
Max Harz 2=97(LC 8)
Max Uplift 3=-129(LC 8), 2=-150(LC 8)
MAx Grav 3=145(LC 13), 2=181(LC 1), 4=104(LC 3)
FORCES. (lb) - fdljax. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7- 0; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl.,1GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mecharjical connection (by others) of truss to bearing plate capable of withstanding 129 lb uplift at joint 3 and 150 lb uplift at
joint 2. f
6) In the LOAD C/)SE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
1) Dead + Roof L
Uniform Loads
Vert: 1
Trapezoidal Lo
Vert: 2
(balanced): Lumber Increase=1.25, Plate Increase=1.25
(Pif)
=27, B=27)-to-3= 81(F=-14, B=-14), 5=0(F=10, B=10)-to-4=-30(F=-5, B=-5)
Walter P. Finn PE No.22639
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING - Verily
design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for
use only with lvllfekb connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system.
fore use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design�&acing
Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
We[(
Is always required
for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storcige,
delivery, erection and bracing of trusses and truss systems, seeANSUID/► AuaillyCrBada, DSO-89 and BCSI Btdldfng Component
6904 Parke East Blvd.
Satiety lnlonnali
P available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 33610
job
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569653
m11324
KJB
MONO TRUSS
2
1
Job Reference (optional)
cnamoers i russ, mc., tort r-rerce, rL
-1-2-9
2
3x4 =
3.30 12
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KK-icrrOtC6jnB5ChLP_YExyaLZfXbOXMitOZm7fgzYQkO
4-11-9
4
3
Scale = 1:11.7
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.11
Vert(LL) -0.02 4-7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.10
Vert(CT) -0.03 4-7 >999 240
BCLL 0.0
Rep Stress Incr NO
WB 0.00
Horz(CT) 0.00 2 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 17 lb FT = 0%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
REACTIONS. (Ibl/size) 3=95/Mechanical, 2=148/0-9-11, 4=46/Mechanical
Max Horz 2=75(LC 8)
Max Uplift 3=-84(LC 8), 2=-136(LC 8)
Max Grav 3=95(LC 1), 2=148(LC 1), 4=77(LC 3)
FORCES. (lb)-1ylax. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-11-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; 6=45ft L=50ft; eave=6ft; Cat.
II; Exp C; Encl.,IGCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between 'he bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 84 lb uplift at joint 3 and 136 lb uplift at
joint 2.
6) In the LOAD CASES) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1 ,2=-54
Trapezoidal Loads (pit)
Vert: 2 O(F=27, B=27)-to-3= 67(F= 7, 13 -7), 5=0(F=10, 13=10)-to-4— 25(F=-2, B=-2)
Walter P. Finn PE No.22839
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING - Verily
design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE
Design valld for
se only with MITek�V connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
Incorporate this design Into the
�"
a truss system.
building design.I
fore use, the building designer must verify the applicability of design parameters and properly overall
Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MOW
Is always required
for stability and to prevent collapse with possible personal Injury and property damage, For general guidance regarding the
fabrication, storage,
delivery, erection and bracing of trusses and truss systems, seeANSUIPII QualByCdreda, DSB-09 and SCSI Bu¢ding Component
6904 Parke East Blvd.
Safety lntmmaRonovailable
from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
THE ROYALE
T13569654
m11324
MV2
VALLEY
1
1
Job Reference (optional)
Chambers Truss,
Fort Pierce, FL a. t su 5 mar i i zu i a rvu i eK muusu ies, in, I nu rvrar cc ua, j +u Zv t v aye
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-AoPDbDDkU5JygrwbYFIAVntlPxxUGpy1cDVgB6zYQkN
3x4
4.00 12
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.04
Vert(LL)
n/a
n/a
999
TCDL 7.0
Lumber DOL
1.25
BC 0.02
Vert(CT)
n/a
n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00 2
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-P
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x SP No.3
REACTIONS. (I I/size) 1=41/2-0-0, 2=30/2-0-0, 3=11/2-0-0
Mix Horz 1=21(LC 10)
Max Uplift 1=-20(LC 10), 2— 30(LC 10)
Max Grav 1=42(LC 15), 2=32(LC 15), 3=22(LC 3)
FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-
11; Exp C; Encl.
shown; Lumbei
2) Gable requires
3) This truss has 1
4) ` This truss hw
will fit between
5) Bearing at joint
capacity of bea
6) Provide mecha
joint 2.
Scale = 1:6.1
PLATES GRIP
MT20 244/190
Weight: 5 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft L=50ft; eave=6ft; Cat.
GCpi=0.18; MW FRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
DOL=1.60 plate grip DOL=1.60
;ontinuous bottom chord bearing.
een designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
he bottom chord and any other members.
s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
ing surface.
iical connection (by others) of truss to bearing plate capable of withstanding 20 lb uplift at joint 1 and 30 lb uplift at
Walter P. Finn PE No22639
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING - Verllydesign
parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 10/03/2015 BEFORE USE
Design valid for
�se only with KAHTek® connect". This design Is based only upon parameters shown, and is foroan Individual building component, not
a truss system. Before
building design.!
use, the building designer must vedfy the applicability of design parameters and properly incorporate this design Into The overall
Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
Welk'
Is always required
fabrication, storbge,
for stability and to preventcollapse with possible personal Injury and property damage. For general guidance regarding the
delivery, erection and bracing of trusses and truss systems, seeANSt4pll QualityCdeda, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Sa/ety(n/ormarbn]vailable
from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314.
Tampa, FL 33610
Job
Truss
Truss Type
Qty
Ply
THE ROYAL E
T13569655
m11324
MV4
VALLEY
1
1
Job Reference (optional)
L.namoers I russ, Inc., MR fierce, r-L
3x4
I D:_kfiGCA6bx7j2Sy1 H DXFw7ye3KX-AoPDbDDkU5JygrwbYFIAVntgFxvAGpyl cDVg B6zYQkN
4-0-0 1
4-0-0
Scale = 1:9.4
3x4 II
2
3
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Well Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.37
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.17
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00 n1a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-P
Weight: 12lb FT=O%
LUMBER- I BRACING -
TOP CHORD 2x4' SP NO.3 TOP CHORD
BOT CHORD 2x4, SP No.3
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS. (lb/size) 1=109/4-0-0, 3=109/4-0-0
Max Harz 1=56(LC 10)
Max Uplift 1=-54(LC 10), 3=-72(LC 10)
Max Grav 1=112(LC 15), 3=117(LC 15)
FORCES. (lb) - Mi . Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
Structural wood sheathing directly applied or 4-0-0 oc puffins,
except end verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; VUlt=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; B=45ft; L=50ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Gable requires csntinuous bottom chord bearing.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between tF�e bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 1 and 72 lb uplift at
joint 3.
Walter P. Finn PE No.22639
67iTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 22,2018
® WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED MI EK REFERANCE PAGE HII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MITekb connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
�"
a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
design. Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
building Bracing prevent
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
6904 Parke East Blvd.
fabrlcatlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSUIPII GualllyCi9edd, DSB-69 and SCSI BuYding Component
Softly Infonnatloinavallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. VA 22314.
Tampa, FL 33610
Symbols
PLATE LOCATION AND ORIENTATION
3/4 Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
For 4 x 2 orientation, locate
plates 0-14d' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
'Plate location details available in MiTek20/20
software or upon request.
PLATE SIZE
/�
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
I
NE■
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
- ANSI/TPI-1 National -Design Specification -for Metal —
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 dimensions shown In ft-in-sixteenths
(Drawings not to scale)
1 2 3
TOP CHORDS
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDSAND WEBS ARE IDENTIFIED BY END JOINT
NUMBERSAETTERS,
PRODUCT CODE APPROVALS
ICC-ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTek® All Rights Reserved
MiTek`
MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015
® General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on Inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane atjoint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/TPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 191Yo at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or purlins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless Indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) -before use. —Reviewing pictures alone
Is not sufficient.
20. Design assumes manufacture in accordance with
ANSI/TPI 1 Quality Criteria.