HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
PLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
Street:
City, State, Zip:
WYPE THE GRAND CARLTON
L-�`p'�Q ��,1� l�
T. PIERCE , FL ,
Builder Name:
Permit Office:
Permit Number:
Owner:
WYNNE BUILDING CROP
Jurisdiction:
Design Location: FL, Fort Pierce
County::
1. New construction or existing
2. Single fa+ ily or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft2)
Conditioned floor area below grade (ft2)
7. Windows(141.3 sqft.) Description
a. U-Factor: Sgl, U=0.54
SHGC.: SHGC=0.25
b. U-Factor: Sgl, U=0.55
SHGC: SHGC=0.25
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHG:
Area We ghted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types (1445.5 sqft.)
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
Glass/Floor Area: 0.098
WYNNE BUILDING COPR.
ST. LUCIE COUNTY
@CANNCD
av
M Lucie Cowie
ST. LUCIE COUNTY
St. Lucie (Florida Climate Zone 2 )
New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
1
c. N/A
R= ft2
2
d. N/A
R= ft2
10. Ceiling Types (1446.0 sqft.)
Insulation Area
Yes
a. Under Attic (Vented)
R=30.0 1446.00 ft2
1446
b. N/A
R= ft2
c. N/A
R= ft2
0
11. Ducts
R ft2
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
101.25 ft2
40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
a. Central Unit
34.8 SEER:15.00
ft2
13. Heating systems
kBtu/hr Efficiency
ft2
a. Electric Heat Pump
34.8 HSPF:8.50
3.832 ft.
0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
Insulation Area
EF:0.970
R=0.0 1445.50 ft2
b. Conservation features
R= ft2
None
R= ft2
15. Credits
Pstat
Total Proposed Modified
Loads: 48.03
PASS
Total Baseline
Loads: 48.08
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code. t/. �� _ 12.c_-Y-1 _
PREPAR BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
Ol-VfIE Sp,�1�
.=f.`
* •.k_r.3.� it
D Wfi
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified) factory -sealed in accordance with R403.3.2.1.
- Compliaqice requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
I
4/4/2018 1:35 AM, EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017 '
PROJECT
Title: 1 WYNNE THE GRAND CARL
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP
Total Stories: 1
Block/Subdivision:
# of Units: I.
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Off �ce: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comments
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location TMY
Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH _MUNI 39
90
70
75 299
62
Low
BLOCKS
Numbers Name Area Volume
I
1 Entire House 1446 11568
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BEDROOM 301
2408 No
0
1
1 Yes
Yes
Yes
2 1, WIC 63
504 No
0
1 No
Yes
Yes
3 M.BATH 56
448 No
0
1 Yes
Yes
Yes
4 KITCHEN 192
1536 Yes
0
1 No
Yes
Yes
5 BATH 45
360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2 204
1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY 55
440 No
0
1 Yes
Yes
Yes
8 LAUNDRY 42
336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING 488
3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
�1 Slab-On=Grade Edge Insulatio
BEDROOM 52 ft 0
301 ft2
_-__
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
____
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
---_
0 1
0
14 Slab -On -Grade Edge Insulatio
•
KITCHEN 1 ft 0
192 ft2
_-__
0 1
0
is
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ft2
-___
0 1
0
6'Slab-On-Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft2
----
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft2
__--
0 1
0
4/4/2018 11:35 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
�# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab-OA-Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
I9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
----
0
1
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
I
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
4 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
18 8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Below
1 NE=>SW Exterior Concrete Block - Ext InsdaEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
2 SW=>NE Exterior Concrete Block - Ext InsdBEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3 N IW=>SE Exterior Concrete Block - Ext InsdHEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
_ 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext InfiEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=NNW Exterior Concrete Block - Ext In-QffDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext IngEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW -NE Exterior Concrete Block - Ext InfiffDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
10 SE=>NW E4brior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 S I =>NE Exterior Concrete Block - Ext InsJ1AUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
_ 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2 -
0.23
0.6
0
4/4/2018 11:35 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
F[)RAA R4nri-9n17
DOORS
# Ornt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
i
Insulated
ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
/ Wall
j Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1' NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5, NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in
0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in
0.54 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
0.54 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
0.55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
A
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
315ft2
24ft 8ft
11
I
INFILTRATION
I
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2598
7
i
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
I 1 Electric Heat Pump/
II
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System -Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
J
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1 a Electric
i
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
i Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
None 'None
I
ft2
414/2018 11:35 AM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 4 of 5
FORM R405-2017.-
'
DUCTS
- Supply
----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
325 ft2
Attic
85 ftZ
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
I
Ceiling Fans:
Cool in !
Jan Feb
Mar
Apr [[
]] Ma
[X]] Jun [X] Jul
X Aug
Se
]Oct
[ ] Nov
Dec
Heating
Jan Feb
Mar
ki
JXJ
Apr (
] May
] Jun ]Jul
l Aul
l Sep
]
Oct
[X] Nov
f X� Dec
`X
Ventin [
Jan [ Feb
lXj
Mar
Apr [[
]] May
[ ]]Jun ]Jul
E E
[ Aug
l
[ Se
[X]
Oct
[X] Nov
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule T pe
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WO)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (W )
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
4/4/2018 11:35 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name:. WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
I
Design .Location: FL, Fort Pierce
COMP, ONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
I
the insulation and an gaps in the air barrier shall be sealed.
y g p
shall be aligned with the _air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
•
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
! The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(includinb
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations'
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spat
as.
Recessed lighting
¢ Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend beh*n" 12ong and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box on`
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed j When required to be sealed, concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
cover
a. in addition, inspection or log walls snall be in accordance with the provisions of ICC-400.
4/4/2018 I111:35 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY
PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
FT. PIERCE, FL,
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Ext Insul, Exterior R=4.1
1250.00 ft2
b. Frame - Wood; Adjacent
R=11.0
192.00 ft2
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number If Bedrooms•
2 d. N/A
R=
ft2
5. Is this a worst case?
10. Ceiling Types
Yes
Insulation
Area
a. Under Attic (Vented)
R=30.0
1446.00 ft2
6. Conditiorjed floor area (ft2)
1446 b. N/A
R=
ft2
7. Windows '� Description
c. N/A
Area
R=
ft2
a. U-Fac or: Sgl, U=0.54
101.25 ft2 11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 325
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55
40.00 ft2
SHGC: SHGC=0.25
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit
34.8 SEER:15.00
SHGC;
d. U-Factor: N/A
ft2
13. Heating systems
kBtu/hr
Efficiency
SHGC,:
Area Weighted Average Overhang Depth:
3.832 ft. a. Electric Heat Pump
34.8
HSPF:8.50
Area Weighted Average SHGC:
0.250
8. Floor Types Insulation
Area 14. Hot water systems
Cap:
40 gallons
a. Slab -Oh -Grade Edge Insulation R=0.0
1445.50 ft2 a. Electric
EF: 0.97
b. N/A R=
ft2
c. N/A R=
ft2 b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Constructid� through the above energy saving features which will be installed (or exceeded)
in this home.beford final inspection. Otherwise, a new EPL Display Card will be completed vk
based on installed Code compliant features.
Builder Signature: Date: �����
Address of New Home\-k\ ,A City/FL Zip:
?TBE ST.a3,
M
*Note: This is n6t a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortga a (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsu�port@energygauge.com or see the EnergyGauge web site at energygauge.com for information .and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label'required-by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/4/20 8 11:35 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1