HomeMy WebLinkAboutD O H - CONSTRUCTION INSPECTION AND FINAL APPROVAL0 LOT: 3 1 BLOCK: SUBDIVISION: River Branch Estates ID#: 3404-809-0007-000-1 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] I [01] TANK SIZE [11 1090.00 [21 [ ] [271 SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [281 DITCHES 70 FT [ ] [03] OUTLET DEVICE [ ] [291 PRIVATE WELLS FT [ ] [04] MULTI -CHAMBERED [L2E_y N ] [ ] [301 PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-68 [ 3 [311 IRRIGATION WELLS FT [ ] 1!'061 I LEGEND 1. 70-143-11DC4 2. [ ] [321 POTABLE WATER 79 FT [ ] 071 WATERTIGHT [ ] [.331 BUILDING FOUNDATIONS 5 FT [ ] [i08] LEVEL [ ] [341 PROPERTY LINES 15 FT [ ] p091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [11 667.88 [2] SQFT [ ] [361 DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 6.00 2. [ ] [381 SLOPES [ ] [I13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 12/04/2019 [ ] [14] DRAINLINE SLOPE [ ] [I115] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 7.00 [ 1 [401 UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [421 ALARMS [ ] [191 AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT I l [20] AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [461 FINAL SITE GRADING [ ] [22] FILL AMOUNT [ ] [471 CONTRACTOR (Benjamin Drew"s Plumbing [ ] [23] FILL TEXTURE I. ] [481 OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [501 ' TANK CRUSHED 6 FILLED Comments: Comments are on page 2. / t. Lucie CHD DATE: 10/11/2019 CONSTRUCTION [ APPROVED , DISAPPROVED � ' IHEALTH) FINAL SYS EM [ APPROVED / DISAPPROVED ]:Lucie =on:tist �Inqrq(ENVIRONMENTAL CHD DATE: 12/04/2019 En ronmental Specialist II Brian gram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 1 EH Database .v 1.0.1 AP1357964 EID1867383 9 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Comment APPLICATION #:AP1357964 PERMIT #: 56-SF-1 867383 DocumNT #: F11357075 DATE PA ID:10/15/2018 FEE PAm:25.00 RECEIPT #:56-PID-3771023 Comments The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 400 ar-• New ST, filter, and 5x10+1x9 long DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final inspection for mound system, gutters, and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, PAC EH Database v 1.0.1 A P1367954 EID188T383 Page 2 of 3