Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE 9-10-19• FORM R405-2017 <l FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Proje Name: LAWSON RESIDENCE Builder Name: JERRY LAWSON i Street 5144 CHERRY PALM WAY Permit Office: Fr PIERCE City, State, Zip: FT PIERCE, FL, Permit Number l'� Y1YU ft CJ�Y�YU f�V Owner JERRY LAWSON Design' Location: FL, Fort Pierce Jurisdiction: 661100 County: St. Lucie (Florida Climate Zone L(Iftb C6t1flil% 1. New construction or existing New (From Plans) 9. Wall Types (2690.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int lnsul, Exterior R=4.1 2420.00 ftz b. Frame - Wood, Adjacent R=11.0 270.00 ft2 3. Number of units, if multiple family c. NIA' R= ft2 4. Number of Bedrooms 3 d. WA R= ft2 5. Is this No 10. Ceiling Types (2291.0 sgft.) Insulation Area a worst case? a. Roof Deck (Unvented) R=20.0 2291.00 ft 6. Conditioned floor area above grade (ft) 2291 b. N/A R= ft2 Conditioned floor area below grade (W) 0 a WA R= ft2 11. Duds R ft2 7. Windows(341.5 sgft) Description Area a. Sup:. Attic, Ret: Attic, AH: Attic 6 1582 a. U-Factor. Dbl, U=0.96 341.50 ft2 SHGC: SHGC=0.42 - b. U-Factor NIA ft2 12. Cooling systems kBtu1hr Efficiency SHGC: a. Central Unit 46.5 SEER:15.00 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Heat.Pump 46.5 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 5.127 ft. Area Weighted Average SHGC: 0.420 14. Hot water systems Types a. Electric Cap: 50gall 8. Floor (2291.0 sgft.) Insulation Area 20 EF: 0.920 a. Slali-On-Grade Edge insulation R=0.0 2291.00 ft2 b. Conservation features b. N/A R= ftz None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 76.88 Glass/Floor Area: 0.149 Total Baseline Loads: 80.50 PASS I I hereby certify that the plans and specifications covered by Review of the plans and S�Ap this calculation are in compliance with the Florida Energy specifications covered by this ��' Code. calculation indicates compliance��, ''_ _ a ll with the Florida Energy Code. I-", r�„r%, ryp=_.�•�- „ PREPARED BY: 'd Before construction is completed DATE. 1 this building will be inspected for I hereby certify that this building-, as designed, is in compliance compliance with Section 553.908 Florida Statutes. the lorida Energy C COD with e: I "A OWNEW/AGENT: BUILDING OFFICIAL: DATE: ± `'�' l DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelop leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). r 9/61201919:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FiaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 I:n12M RAnl;-7n17 INPUT StIMMARY CHECKLIST REPORT PROJECT Title: I Building Type: Owner Name: # of Units: Builder Name, Permit Office: Jurisdiction: Family Type: New/Existing: Comment: LAWSON RESIDENCE User JERRY LAWSON 1 JERRY LAWSON FT PIERCE 661100 _ Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 2291 Total Stories: i Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 5144 CHERRY PALM County: St. Lucie City, State, Zip: FT PIERCE, FL, CLIMATE Design Location TMY Site Design Temp 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2291 22910 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 I Main 2291 22910 Yes 8 3 1 Yes Yes Yes FLOORS # Floor Type Space . Perimeter R Value Area. Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 231 ft 0 2291 ftz -- 0 0 1 ROOF # Type Materials Roof Gable Roof Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat the/slate 2482 ft2 0 ftz Medium N 0.95 No 0.9 No 20 22.6 ATTIC V I # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2291 ftz N Y l CEILING # Ceiling Type Space R Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 0 Blown 2291 ftz 0.11 Wood 9/6/2019 9:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 F cnoae o'nnr,_,)na7 IKIPI IT SI IMNIORY P--14F('-ICI HAT REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 0 _ 1 N Exterior Concrete Block - Int Insul Main 4.0999 74 10 740.0 ft2 0 0.15 0 _ 2 E Exterior Concrete Block - Int Insul Main 4.0999 56 10 560.0 ft2 0 0.15 0 _ 3 S Exterior Concrete Block - Int tnsul Main 4.0999 56 10 560.0 ftz 0 0.15 0 _ 4 W Exterior Concrete Block - Int Insul Main 4.0999 56 10 660.0 ft2 0 0.15 0 _ 5 S Garage Frame -Wood Main 11 25 10 250.0 IF 0.11 0.15 0 6 E Garage Frame - Wood Main 11 2 10 20.0 ft2 0.11 0.15 0 DOORS # Omt Door Type Space Storms U-Value Width eightln Area Ft In Ft 1 S Insulated Main None .46 6 8 48 ft2 2 S Wood Main None A6 2 8 6 8 17.8 ft2 1 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Double (Tinted) Yes 0.96 0.42 N 45.0 ft2 2 ft 0 in 1 ft 0 in None None 2 3 N 1 N 1 Metal Double (Tinted) Metal Double (Tinted) Yes Yes 0.96 0.42 0.96 0.42 N N 15.0 ft2 96.0 IF 10 It 0 in 10 ft 0 in 0 It 6 in 0 ft 6 in None None None None 4 W 4 Metal Double (Tinted) Yes 0.96 0.42 N 24.0 fr 2 ft 0 in 1 ft 6 in None None 5 N 1 Metal Double (Tinted) Yes 0.96 0.42 N 30.0 ft2 2 ft 0 in 1 ft 6 in None None 6 E 2 Metal Double (Tinted) Yes 0.96 0.42 N 16.0 ft2 2 ft 0 in 1 ft 6 in None None 7 S 3 Metal Double (Tinted) Yes 0.96 0.42 N 12.0 ft2 2 ft 0 in 1 It 6 in None None 8 S 3 Metal Double (Tinted) Yes 0.96 0.42 N 60.0 W 5 It 0 in 0 ft 6 in None None I9 W 4 Metal Double (Tinted) Yes 0.96 0.42 N 22.5 ft2 2 ft 0 in 1 It 0 in None None 0 W 4 Metal Double (Tinted) Yes 0.96. 0.42 N 6.0 ft2 2 ft 0 in 1 ft 0 in None None 1 W 4 Metal Double (Tinted) Yes 0.96 0.42 N 15.0 ft2 2 It 0 in 1 ft 0 in None None i GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 676 fie 676 ft2 84 ft loft 1 INFILTRATION # Scope I Method SLA CFM 50 EIA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 I 2672.8 146.73 275.96 .1685 7 9/6/2019 9:26 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 r.�r�s• e-�wnc nnw� !K10 rT Q AARRAOV PI.I! Pell ICT 01=0nRT 1 VI%IVI 1aWV Lv . -- -- - --- -- -- HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:9 48.5 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts - I Central UniU None SEER: 15 46.5 kBtu/hr 1395 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 50 gal 70 gal 120 deg None 1 SOLAR HOT WATER SYSTEM 1 FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF 1 I None None ftZ DUCTS — Supply --- # Location R-Value Area — Return — Air Location Area Leakage Type Handler CFM 25 CFM25 TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 158.2 ft Attic 44.55 ft Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Prograinable Coolin Heating Ventin Thermostat- Y j[ ]] Jan j( j� Feb [[ jj Mar [X] Jan [X) Feb (Xj Mar [[ �� Jan [[ 11 Feb [[�X]] Mar Ceiling Fans: [ j r [ j Ma [X] Jun [X] Jul [X] AugX] [ 1 Apr [ ]May E ] Jun (] Jul E j Au[) [X] A r [. ] May ]Jun [ ]Jul ] Aug Sep [ j Sep [ ] (]Sep [X) Oct Oct Oct Nov Nov Nov Dec Dec Dec Thermostat Schedule Schedule: HERS 2006 Reference Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) Cooling (iNEH) Heating Heating (WEH) AM 78 PM 80 AM 78 PM 78 D) AM 66 IIII PM 68 AM 66 PM 68 78 78 80 78 78 78 78 78 66 66 68 68 66 66 68 68 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 66 66 68 68 68 68 68 68 66 66 68 68 68 68 68 68 78 80 78 78 78 78 78 78 68 68 68 68 68 68 68 68 80 78 78 78 68 68 68 68 80 78 78 78 68 66 68 66 80 - 78 78 78 68 66 68 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run.Time , Cooling System None II I 0 0 0 1 - Electric Heat Pump 0% 1 -Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Defeuft 8 Ibs/s .ft. 0 fl2 0 ft 6.3 Main 9/6/2019i 9:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return duds R 6.0 c) AHU location Attic . No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 46.5 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2291 d) Room unit/PTAC EER e) Other 15.0 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.960 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.420 14. Heating system: Capacity 46.5 c) Area 7c. 341.5 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance I COP a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG 'AFUE' f) Other 9.00 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.92 110. Wall type and insulation: b) Gas fired, natural gas EF c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. ' that this home has complied with the Florida Building Code, Energy Conservation, through the above energy features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL card will be completed based on installed code compliant features. Signature: , / n A- Date: s of New Hour's: 5144 CHERRY PALM WAY City/FL Zip: FT PIERCE. FL 9:26:05 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 i Residential System Sizing Calculation Summary JERRY LAWSON Project Title: 5144 CHERRY PALM WAY LAWSON RESIDENCE FT PIERCE, FL 9/6/2019 Location for weather data: Fort Pierce, FL - Defaults: Latitude(27.48) Altitude(25 ft.) Temp Range(L) Humidi data: Interior RH 50% Outdoor wet bulb 78F Humidity difference 62 r. Winter design temperature(TMY3 99%) 40 F Summer design temperature(TMY3 99%) 91 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 30 F Summer temperature difference 16 F Total heating load calculation 42263 Stuh Total cooling load calculation 43626 Btuh Submitted heating capacity % of talc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 110.0 46500 Sensible (SHR = 0.75) 108.9 34875 Heat Pump + Auxiliary(O.OkW) 110.0 46500 Latent 100.1 11625 Total Electric Heat Pump) 106.6 46500 WINTER CALCULATIONS Winter HPatinn I nail lfnr 7991 nnftl Load component Load Window total 342 sqft 9835 - Btuh Wall total 2283 sqft 9808 Btuh Door total 66 sqft 908 Btuh Ceiling total 2291 sqft 3289 Btuh Floor total 2291 sqft 8177 Btuh Infiltration 103 cfm 3395 Btuh Duct loss 6851 Btuh Subtotal Ventilation 0 cfm 42263 Btuh V:845(232°5) CEitings('a" a lindotvs(233°,5j 0 Btuh ' "" ouas(ta2°sl '� SUMMER CALCULATIONS r Window total 342 sqft Wall total 2283 sqft Door total 66 sqft Ceiling total 2291 sqft Floor total Infiltration 77 cfm Internal gain Duct gain Sens. Ventilation 0 cfm Blower Load Total sensible gain Lat+t gain(ducts) Latent gain(infiltration) Latent gain(ventilation)(i Lat ant gainntemaUoccupants/other) To 1 latent gain 8th Edition 11110 5231 938 2302 0 1358 6240 4831 0 0 32010 6763 3253 0 1600 11615 Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Ceilings{57A) Doorsi2.2°l0.i Infil.(13.5°�I Ducts(2ca"Q�) 43626 Btuh EnergyGauge® ste I PREPARED P: DATE: EnergyGaugeO / USRCZB v6.1.03 bb Uldotjs(�ai'�5j Latentint(VRS) Int.Galn(14.37, : 8th Edition 11110 5231 938 2302 0 1358 6240 4831 0 0 32010 6763 3253 0 1600 11615 Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Btuh Ceilings{57A) Doorsi2.2°l0.i Infil.(13.5°�I Ducts(2ca"Q�) 43626 Btuh EnergyGauge® ste I PREPARED P: DATE: EnergyGaugeO / USRCZB v6.1.03 bb Uldotjs(�ai'�5j Latentint(VRS) Int.Galn(14.37, : i System Sizing culations n Summer Residential Load - Room by Room Component Deta9@s JERRY LAWSON Project Title: 5144 CHERRY PALM WAY LAWSON RESIDENCE FTIPIERCE, FL 9/6/2019 I Reference City: Fort Pierce, FL Temperature Difference: 16.0F(TMY3 99%) Humidity difference: 62gr. Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross Shaded Unshadec Shaded Unshaded 1 2 NFRC 0.42, 0.96 No No N 2.Oft 1.0ft 45.0 0.0 45.0 24 24 1096 Btuh 2 2 NFRC 0.42, 0.96 No No N 10.0f 0.5ft 15.0 0.0 15.0 24 24 365 Btuh 3 2 NFRC 0.42, 0.96 No No N 10.Of 0.5ft 95.0 0.0 96.0 24 24 2338 Btuh 4 2 NFRC 0.42. 0.96 No No W 2.Oft 1.5ft 24.0 0.5 23.5 24 56 1332 Btuh 5 2 NFRC 0.42, 0.96 No No N 2.Oft 1.5ft 30.0 0.0 30.0 24 24 731 Btuh 6 2 NFRC 0.42, 0.96 No No E 2.Oft 1.5ft 16.0 0.6 15.4 24 56 878 Btuh 7 2 NFRC 0.42, 0.96 No No S 2.Oft 1.5ft 12.0 12.0 0.0 24 27 292 Btuh 8 2 NFRC 0.42, 0.96 No No S 5.Oft 0.5ft 60.0 60.0 0.0 24 27 1461 Stuh 9 2 NFRC 0.42, 0.96 No No W 2.Oft 1.0ft 22.5 3.0 19.5 24 56 1168 Btuh 10 2 NFRC 0.42, 0.96 No No W 2.0ft 1.011 6.0 2.0 4.0 24 56 274 Btuh 11 2 NFRC 0.42, 0.96 No No W 2.Oft 1.0ft 15.0 2.0 13.0 24 56 779 Btuh Window Total 1 342 (sqft) 10712 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Concrete Btk,Hollow - Ext 0.15 4.1/0.0 554.0 2.4 1323 Btuh 2 Concrete Blk, Hollow - Ext 0.15 4.1/0.0 544.0 2.4 1299 Btuh 3 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 440.0 2.4 1051 Btuh 4 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 492.5 2.4 1176 Btuh 5 Frame - Wood - Adj 0.09 11.010.0 232.2 1.5 352 Btuh 6 Frame - Wood - Adj 0.09 11.010.0 20.0 1.5 30 Btuh Wall Total 2283 (sqft) 5231 Btuh Doors Type Area (sqft) HTM Load j 1 Insulated - Exterior 48.0 14.3 684 Btuh I 2 Wood - Garage 17.8 14.3 254 Btuh Door Total 66 (sqft) 938 Btuh Ceilings Type/Color/Surface U Value R Value Area(sqft) HTM Load 1 Unvented Attic/LightRle 0.048 0.0/20.0 2291.0 1.00 2302 Btuh Ceiling Total 2291 (sqft) 2302 Btuh , Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 2291 (ft-perimeter) 0.0 0 Btuh Floor Total 2291.0 (sqft) 0 Btuh Zone Envelope Subtotal: 19184 Btuh [infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.20 22910 1.00 77.2 Load 1368 Btuh Internal gam Occupants Btuhloccupant Appliance 8 X 230 + 4400 Load I 6240 Btuh Sensible Envelope Load: 26781 Btuh Duct load Average sealed, Supply(R6.0-Atdc), Retum(R6.0-Attic) DGM of 0.178) 4760 Btuh 1 Sensible Zone Load 31542 Btuh EnergyGauge® / USRCZB v6.1.03 Page 1 i i Manual J Summer Calculations Residential Load - Component Details (continued) JERRY LAWSON Project Title: Climate:FL VERO_BEACH _MUNICIPAL A 5144 CHERRY PALM WAY LAWSON RESIDENCE FT PIERCE, FL 9/6/2019 Wi�ndovus I Duct load July excursion for System 1 Excursion Subtotal: 398 Btuh -] 398 Btuh 71 Btuh Sensible Excursion Load 469 Btuh EnergyGaugeG / USRCZB v6.1.03 Page 2 Manual J Summer Calculations ' Residential Load - Component Details (continued) JERIRY LAWSON Project Title: Climate: FL VERO_BEACH_MUNICIPAL A 5144 CHERRY PALM WAY LAWSON RESIDENCE FT PIERCE, FL 9/6/2019 .... ..... ....,. .. .. .. �. .. .. .. .,,.. ,. ..,.n ,.. .. ... .: ... .. .+.,,,...,t......w. _r.., .1:.Y.iiSyi'r K_•.:ln�:rd,:'::S!i?a'l. ;''�1.`�r. t.c ,5 . :,y5+, .-�,p) t l ..��1,.' : C .. 1 i. v�,•� ,_Gi ?3('' t.s, f u ,t• . ,. ;�7, : 'CY ., , x, ..y .:.� . ,t� ,.a , � .:,�'Gx. `r.': \ 1,r'n'� or'.xre .55' : r�• : %'(fl'�s,:1 :y - ( rit� 'i7 . I,P.•1•_.•i'•. y�. .-Y':.:j S?n 3 P�� ,rV „ r/:`�tk¢,.Z{,i-'l � � ax f k:,. :h:' P1T . .�:,:r.,fiA 15',"•'({li 7} . `�( ,s;rciG,4 ..:;i�' f:. ,ur<s'2 � � fr , i; � `i< 1 �•. 1 �: L\ ,y�,•P,:=.,,C 8 �: }n�;y,.'; .hb�,) !"' 'iryA:1:L'' .(, .e's V.r.,y.,.rJ;= ,si7'%^'P`{"�'4;::p�lhy} Sr.. R SN, .�.: t°j:r lA:+s .r --Y •r. f - ».ate k; rt,•ir����.�:r',;'S?'��55ssac:''�!�cfAn�63:4r4)'v^rn!F�±;s:�';.��r�,ay�.r+`::fJll!?�;A?.4:.,��.�=abUu;r,—,.��k��iC3.�.i�"e.�;..:4.hES�gt.i I Sensible Envelope Load All Zones 27179 Btuh Sensible Duct Load 4831 Btuh Total Sensible Zone Loads 32010 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 32010 Btuh j Totals for Cooling Latent infiltration gain (for 62 gr. humidity difference) 3263 Btuh Latent ventilation gain 0 Btuh Latent duct gain 6763 Btuh Latent occupant gain (8.0 people @ 200 Btuh per person) 1600 Btuh Latent other gain 0 Btuh Latent total gain 11615 Btuh TOTAL GAIN 43626 Btuh 'Key: Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U-Factor) (Irish - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half('%)) (Omt- compass orientation) EnergyGauge® / USRCZB v6.1.03 Page 3