HomeMy WebLinkAboutENERGY EFFICIENCY CODE 9-10-19• FORM R405-2017
<l FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Proje Name: LAWSON RESIDENCE
Builder Name: JERRY LAWSON
i
Street 5144 CHERRY PALM WAY
Permit Office: Fr PIERCE
City, State, Zip: FT PIERCE, FL,
Permit Number
l'� Y1YU ft
CJ�Y�YU f�V
Owner JERRY LAWSON
Design' Location: FL, Fort Pierce
Jurisdiction: 661100
County: St. Lucie (Florida Climate Zone L(Iftb C6t1flil%
1. New construction or existing New (From Plans)
9. Wall Types (2690.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int lnsul, Exterior
R=4.1 2420.00 ftz
b. Frame - Wood, Adjacent
R=11.0 270.00 ft2
3. Number of units, if multiple family
c. NIA'
R= ft2
4. Number of Bedrooms 3
d. WA
R= ft2
5. Is this No
10. Ceiling Types (2291.0 sgft.)
Insulation Area
a worst case?
a. Roof Deck (Unvented)
R=20.0 2291.00 ft
6. Conditioned floor area above grade (ft) 2291
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
a WA
R= ft2
11. Duds
R ft2
7. Windows(341.5 sgft) Description Area
a. Sup:. Attic, Ret: Attic, AH: Attic
6 1582
a. U-Factor. Dbl, U=0.96 341.50 ft2
SHGC: SHGC=0.42
-
b. U-Factor NIA ft2
12. Cooling systems
kBtu1hr Efficiency
SHGC:
a. Central Unit
46.5 SEER:15.00
c. U-Factor. N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A ft2
a. Electric Heat.Pump
46.5 HSPF:9.00
SHGC:
Area Weighted Average Overhang Depth: 5.127 ft.
Area Weighted Average SHGC: 0.420
14. Hot water systems
Types
a. Electric
Cap: 50gall
8. Floor (2291.0 sgft.) Insulation Area
20
EF: 0.920
a. Slali-On-Grade Edge insulation R=0.0 2291.00 ft2
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 76.88
Glass/Floor Area: 0.149
Total Baseline Loads: 80.50
PASS
I
I hereby certify that the plans and specifications covered by
Review of the plans and
S�Ap
this calculation are in compliance with the Florida Energy
specifications covered by this
��'
Code.
calculation indicates compliance��,
''_ _
a ll
with the Florida Energy Code.
I-", r�„r%, ryp=_.�•�- „
PREPARED BY: 'd
Before construction is completed
DATE. 1
this building will be inspected for
I hereby certify that this building-, as designed, is in compliance
compliance with Section 553.908
Florida Statutes.
the lorida Energy C
COD
with e:
I
"A
OWNEW/AGENT:
BUILDING OFFICIAL:
DATE: ± `'�' l
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelop leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
r 9/61201919:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FiaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
I:n12M RAnl;-7n17 INPUT StIMMARY CHECKLIST REPORT
PROJECT
Title: I
Building Type:
Owner Name:
# of Units:
Builder Name,
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
LAWSON RESIDENCE
User
JERRY LAWSON
1
JERRY LAWSON
FT PIERCE
661100 _
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 2291
Total Stories: i
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 5144 CHERRY PALM
County: St. Lucie
City, State, Zip: FT PIERCE,
FL,
CLIMATE
Design Location TMY Site
Design Temp
97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO BEACH_MUNI 39 90
70 75 299 62 Low
BLOCKS
Number
Name Area
Volume
1
Blockl 2291
22910
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1 I
Main 2291
22910 Yes 8
3 1 Yes Yes Yes
FLOORS
#
Floor Type Space
. Perimeter R Value
Area. Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 231 ft 0
2291 ftz -- 0 0 1
ROOF
#
Type Materials
Roof Gable Roof
Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Hip Flat the/slate
2482 ft2 0 ftz Medium
N 0.95 No 0.9 No 20 22.6
ATTIC
V
I #
Type Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic Unvented 0 2291 ftz N Y
l
CEILING
#
Ceiling Type
Space R Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Unvented)
Main 0 Blown
2291 ftz 0.11 Wood
9/6/2019 9:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
F
cnoae o'nnr,_,)na7 IKIPI IT SI IMNIORY P--14F('-ICI HAT REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
0
_ 1
N
Exterior
Concrete Block - Int Insul
Main
4.0999 74
10
740.0 ft2
0 0.15
0
_ 2
E
Exterior
Concrete Block - Int Insul
Main
4.0999 56
10
560.0 ft2
0 0.15
0
_ 3
S
Exterior
Concrete Block - Int tnsul
Main
4.0999 56
10
560.0 ftz
0 0.15
0
_ 4
W
Exterior
Concrete Block - Int Insul
Main
4.0999 56
10
660.0 ft2
0 0.15
0
_ 5
S
Garage
Frame -Wood
Main
11 25
10
250.0 IF
0.11 0.15
0
6
E
Garage
Frame - Wood
Main
11 2
10
20.0 ft2
0.11 0.15
0
DOORS
#
Omt
Door Type
Space
Storms U-Value
Width
eightln
Area
Ft
In
Ft
1
S
Insulated
Main
None
.46
6
8
48 ft2
2
S
Wood
Main
None
A6
2
8
6 8 17.8 ft2
1
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Omt ID
Frame Panes
NFRC
U-Factor SHGC
Imp Area
Depth
Separation
Int Shade
Screening
1
N 1
Metal Double (Tinted)
Yes
0.96 0.42
N
45.0 ft2
2 ft 0 in
1 ft 0 in
None
None
2
3
N 1
N 1
Metal Double (Tinted)
Metal Double (Tinted)
Yes
Yes
0.96 0.42
0.96 0.42
N
N
15.0 ft2
96.0 IF
10 It 0 in
10 ft 0 in
0 It 6 in
0 ft 6 in
None
None
None
None
4
W 4
Metal Double (Tinted)
Yes
0.96 0.42
N
24.0 fr 2
ft 0 in
1 ft 6 in
None
None
5
N 1
Metal Double (Tinted)
Yes
0.96 0.42
N
30.0 ft2
2 ft 0 in
1 ft 6 in
None
None
6
E 2
Metal Double (Tinted)
Yes
0.96 0.42
N
16.0 ft2
2 ft 0 in
1 ft 6 in
None
None
7
S 3
Metal Double (Tinted)
Yes
0.96 0.42
N
12.0 ft2
2 ft 0 in
1 It 6 in
None
None
8
S 3
Metal Double (Tinted)
Yes
0.96 0.42
N
60.0 W
5 It 0 in
0 ft 6 in
None
None
I9
W 4
Metal Double (Tinted)
Yes
0.96 0.42
N
22.5 ft2
2 ft 0 in
1 It 0 in
None
None
0
W 4
Metal Double (Tinted)
Yes
0.96. 0.42
N
6.0 ft2
2 ft 0 in
1 ft 0 in
None
None
1
W 4
Metal Double (Tinted)
Yes
0.96 0.42
N
15.0 ft2
2 It 0 in
1 ft 0 in
None
None
i
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
676 fie 676 ft2
84 ft
loft
1
INFILTRATION
# Scope
I
Method SLA
CFM 50 EIA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000445
I
2672.8 146.73
275.96
.1685
7
9/6/2019 9:26 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
r.�r�s• e-�wnc nnw� !K10 rT Q AARRAOV PI.I! Pell ICT 01=0nRT
1 VI%IVI 1aWV
Lv .
-- -- - --- -- --
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
None
HSPF:9 48.5 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
-
I Central UniU
None
SEER: 15 46.5 kBtu/hr 1395 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.92 50 gal 70 gal
120 deg
None
1
SOLAR HOT WATER SYSTEM
1
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
1
I
None None
ftZ
DUCTS
— Supply ---
# Location R-Value Area
— Return — Air
Location Area Leakage Type Handler
CFM 25 CFM25
TOT OUT
QN
RLF
HVAC #
Heat Cool
1 Attic 6 158.2 ft Attic
44.55 ft Default Leakage Attic
(Default) (Default)
1 1
TEMPERATURES
Prograinable
Coolin
Heating
Ventin
Thermostat- Y
j[ ]] Jan j( j� Feb [[ jj Mar
[X] Jan [X) Feb (Xj Mar
[[ �� Jan [[ 11 Feb [[�X]] Mar
Ceiling Fans:
[ j r [ j Ma [X] Jun [X] Jul [X] AugX]
[ 1 Apr
[ ]May E ] Jun (] Jul E j Au[)
[X] A r [. ] May ]Jun [ ]Jul ] Aug
Sep [ j
Sep [ ]
(]Sep [X)
Oct
Oct
Oct
Nov
Nov
Nov
Dec
Dec
Dec
Thermostat
Schedule
Schedule: HERS 2006 Reference
Type 1
2 3
Hours
4 5 6 7
8 9
10
11
12
Cooling (WD)
Cooling (iNEH)
Heating
Heating (WEH)
AM 78
PM 80
AM 78
PM 78
D) AM 66
IIII PM 68
AM 66
PM 68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78 78
78 78 78 78
78 78 78 78
78 78 78 78
66 66 68 68
68 68 68 68
66 66 68 68
68 68 68 68
78 80
78 78
78 78
78 78
68 68
68 68
68 68
68 68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80 -
78
78
78
68
66
68
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run.Time , Cooling System
None
II
I 0
0
0 1 - Electric Heat Pump
0%
1 -Central Unit
MASS
Mass
Type
Area
Thickness Furniture Fraction Space
Defeuft
8 Ibs/s .ft.
0 fl2
0 ft 6.3
Main
9/6/2019i 9:26 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return duds R
6.0
c) AHU location
Attic
. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
46.5
a) Split system SEER
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2291
d) Room unit/PTAC EER
e) Other
15.0
7. Windows, type and area
a) U-factor.(weighted average)
7a.
0.960
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.420
14. Heating system: Capacity
46.5
c) Area
7c.
341.5
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance I COP
a) U-factor.(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG 'AFUE'
f) Other
9.00
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.92
110. Wall type and insulation:
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
' that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
card will be completed based on installed code compliant features.
Signature: , / n
A- Date:
s of New Hour's: 5144 CHERRY PALM WAY City/FL Zip: FT PIERCE. FL
9:26:05 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
i
Residential System Sizing Calculation
Summary
JERRY LAWSON Project Title:
5144 CHERRY PALM WAY LAWSON RESIDENCE
FT PIERCE, FL
9/6/2019
Location for weather data: Fort Pierce, FL - Defaults: Latitude(27.48) Altitude(25 ft.) Temp Range(L)
Humidi data: Interior RH 50%
Outdoor
wet bulb 78F Humidity difference 62 r.
Winter design temperature(TMY3 99%) 40
F
Summer design temperature(TMY3 99%) 91
F
Winter setpoint
70
F
Summer setpoint
75
F
Winter temperature difference
30
F
Summer temperature difference
16
F
Total heating load calculation
42263
Stuh
Total cooling load calculation
43626
Btuh
Submitted heating capacity
% of talc
Btuh
Submitted cooling capacity
% of calc
Btuh
Total (Electric Heat Pump)
110.0
46500
Sensible (SHR = 0.75)
108.9
34875
Heat Pump + Auxiliary(O.OkW)
110.0
46500
Latent
100.1
11625
Total Electric Heat Pump)
106.6
46500
WINTER CALCULATIONS
Winter HPatinn I nail lfnr 7991 nnftl
Load component
Load
Window total
342
sqft
9835
- Btuh
Wall total
2283
sqft
9808
Btuh
Door total
66
sqft
908
Btuh
Ceiling total
2291
sqft
3289
Btuh
Floor total
2291
sqft
8177
Btuh
Infiltration
103
cfm
3395
Btuh
Duct loss
6851
Btuh
Subtotal
Ventilation
0
cfm
42263
Btuh
V:845(232°5)
CEitings('a" a
lindotvs(233°,5j
0 Btuh
' "" ouas(ta2°sl
'�
SUMMER CALCULATIONS
r
Window total 342 sqft
Wall total 2283 sqft
Door total 66 sqft
Ceiling total 2291 sqft
Floor total
Infiltration 77 cfm
Internal gain
Duct gain
Sens. Ventilation 0 cfm
Blower Load
Total sensible gain
Lat+t gain(ducts)
Latent gain(infiltration)
Latent gain(ventilation)(i Lat ant gainntemaUoccupants/other)
To 1 latent gain
8th Edition
11110
5231
938
2302
0
1358
6240
4831
0
0
32010
6763
3253
0
1600
11615
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Ceilings{57A)
Doorsi2.2°l0.i
Infil.(13.5°�I
Ducts(2ca"Q�)
43626 Btuh
EnergyGauge® ste I
PREPARED P:
DATE:
EnergyGaugeO / USRCZB v6.1.03
bb Uldotjs(�ai'�5j
Latentint(VRS)
Int.Galn(14.37, :
8th Edition
11110
5231
938
2302
0
1358
6240
4831
0
0
32010
6763
3253
0
1600
11615
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Btuh
Ceilings{57A)
Doorsi2.2°l0.i
Infil.(13.5°�I
Ducts(2ca"Q�)
43626 Btuh
EnergyGauge® ste I
PREPARED P:
DATE:
EnergyGaugeO / USRCZB v6.1.03
bb Uldotjs(�ai'�5j
Latentint(VRS)
Int.Galn(14.37, :
i
System Sizing culations n Summer
Residential Load - Room by Room Component Deta9@s
JERRY LAWSON Project Title:
5144 CHERRY PALM WAY LAWSON RESIDENCE
FTIPIERCE, FL
9/6/2019
I
Reference City: Fort Pierce, FL Temperature Difference: 16.0F(TMY3 99%) Humidity difference: 62gr.
Type*
Overhang
Window Area(sqft)
HTM
Load
Window
Panes SHGC U InSh
IS Omt
Len
H t
Gross Shaded Unshadec
Shaded Unshaded
1
2 NFRC 0.42, 0.96 No
No
N
2.Oft
1.0ft
45.0
0.0 45.0
24
24
1096
Btuh
2
2 NFRC 0.42, 0.96 No
No
N
10.0f
0.5ft
15.0
0.0 15.0
24
24
365
Btuh
3
2 NFRC 0.42, 0.96 No
No
N
10.Of
0.5ft
95.0
0.0 96.0
24
24
2338
Btuh
4
2 NFRC 0.42. 0.96 No
No
W
2.Oft
1.5ft
24.0
0.5 23.5
24
56
1332
Btuh
5
2 NFRC 0.42, 0.96 No
No
N
2.Oft
1.5ft
30.0
0.0 30.0
24
24
731
Btuh
6
2 NFRC 0.42, 0.96 No
No
E
2.Oft
1.5ft
16.0
0.6 15.4
24
56
878
Btuh
7
2 NFRC 0.42, 0.96 No
No
S
2.Oft
1.5ft
12.0
12.0 0.0
24
27
292
Btuh
8
2 NFRC 0.42, 0.96 No
No
S
5.Oft
0.5ft
60.0
60.0 0.0
24
27
1461
Stuh
9
2 NFRC 0.42, 0.96 No
No
W
2.Oft
1.0ft
22.5
3.0 19.5
24
56
1168
Btuh
10
2 NFRC 0.42, 0.96 No
No
W
2.0ft
1.011
6.0
2.0 4.0
24
56
274
Btuh
11
2 NFRC 0.42, 0.96 No
No
W
2.Oft
1.0ft
15.0
2.0 13.0
24
56
779
Btuh
Window Total
1 342 (sqft)
10712 Btuh
Walls
Type
U-Value
R-Value
Area(sqft)
HTM
Load
Cav/Sheath
1
Concrete Btk,Hollow - Ext
0.15
4.1/0.0
554.0
2.4
1323
Btuh
2
Concrete Blk, Hollow - Ext
0.15
4.1/0.0
544.0
2.4
1299
Btuh
3
Concrete Blk,Hollow - Ext
0.15
4.1/0.0
440.0
2.4
1051
Btuh
4
Concrete Blk,Hollow - Ext
0.15
4.1/0.0
492.5
2.4
1176
Btuh
5
Frame - Wood - Adj
0.09
11.010.0
232.2
1.5
352
Btuh
6
Frame - Wood - Adj
0.09
11.010.0
20.0
1.5
30
Btuh
Wall Total
2283 (sqft)
5231
Btuh
Doors
Type
Area (sqft)
HTM
Load
j 1
Insulated - Exterior
48.0
14.3
684
Btuh I
2
Wood - Garage
17.8
14.3
254
Btuh
Door Total
66 (sqft)
938
Btuh
Ceilings
Type/Color/Surface
U Value
R Value
Area(sqft)
HTM
Load
1
Unvented Attic/LightRle
0.048
0.0/20.0
2291.0
1.00
2302
Btuh
Ceiling Total
2291 (sqft)
2302
Btuh ,
Floors
Type
R-Value
Size
HTM
Load
1
Slab On Grade
0.0
2291 (ft-perimeter)
0.0
0
Btuh
Floor Total
2291.0 (sqft)
0
Btuh
Zone Envelope Subtotal:
19184 Btuh
[infiltration
Type Wholehouse ACH Volume(cuft) Wall Ratio CFM=
Natural 0.20 22910 1.00 77.2
Load
1368 Btuh
Internal
gam
Occupants Btuhloccupant Appliance
8 X 230 + 4400
Load I
6240 Btuh
Sensible Envelope Load:
26781 Btuh
Duct load
Average sealed, Supply(R6.0-Atdc), Retum(R6.0-Attic) DGM of 0.178)
4760 Btuh
1
Sensible Zone Load
31542 Btuh
EnergyGauge® / USRCZB v6.1.03 Page 1
i
i
Manual J Summer Calculations
Residential Load - Component Details (continued)
JERRY LAWSON Project Title: Climate:FL VERO_BEACH _MUNICIPAL A
5144 CHERRY PALM WAY LAWSON RESIDENCE
FT PIERCE, FL
9/6/2019
Wi�ndovus
I
Duct load
July excursion for System 1
Excursion Subtotal:
398 Btuh -]
398 Btuh
71 Btuh
Sensible Excursion Load
469 Btuh
EnergyGaugeG / USRCZB v6.1.03 Page 2
Manual J Summer Calculations
' Residential Load - Component Details (continued)
JERIRY LAWSON Project Title: Climate: FL VERO_BEACH_MUNICIPAL A
5144 CHERRY PALM WAY LAWSON RESIDENCE
FT PIERCE, FL
9/6/2019
.... ..... ....,. .. .. .. �. .. .. .. .,,.. ,. ..,.n ,.. .. ... .: ... .. .+.,,,...,t......w. _r.., .1:.Y.iiSyi'r K_•.:ln�:rd,:'::S!i?a'l. ;''�1.`�r.
t.c ,5 . :,y5+, .-�,p) t l ..��1,.' : C .. 1 i. v�,•� ,_Gi ?3(''
t.s, f u ,t• . ,. ;�7, : 'CY ., , x, ..y .:.� . ,t� ,.a , � .:,�'Gx. `r.': \ 1,r'n'� or'.xre .55' : r�• : %'(fl'�s,:1 :y - ( rit� 'i7 . I,P.•1•_.•i'•.
y�. .-Y':.:j S?n 3 P�� ,rV „ r/:`�tk¢,.Z{,i-'l � � ax f k:,. :h:' P1T . .�:,:r.,fiA 15',"•'({li 7} . `�( ,s;rciG,4 ..:;i�' f:. ,ur<s'2 � � fr , i; � `i< 1 �•.
1 �: L\ ,y�,•P,:=.,,C 8 �: }n�;y,.'; .hb�,) !"' 'iryA:1:L'' .(, .e's V.r.,y.,.rJ;= ,si7'%^'P`{"�'4;::p�lhy} Sr.. R SN, .�.: t°j:r lA:+s .r --Y •r.
f
- ».ate
k; rt,•ir����.�:r',;'S?'��55ssac:''�!�cfAn�63:4r4)'v^rn!F�±;s:�';.��r�,ay�.r+`::fJll!?�;A?.4:.,��.�=abUu;r,—,.��k��iC3.�.i�"e.�;..:4.hES�gt.i
I
Sensible Envelope Load All Zones
27179
Btuh
Sensible Duct Load
4831
Btuh
Total Sensible Zone Loads
32010
Btuh
Sensible ventilation
0
Btuh
Blower
0
Btuh
Whole House
Total sensible gain
32010
Btuh
j Totals for Cooling
Latent infiltration gain (for 62 gr. humidity difference)
3263
Btuh
Latent ventilation gain
0
Btuh
Latent duct gain
6763
Btuh
Latent occupant gain (8.0 people @ 200 Btuh per person)
1600
Btuh
Latent other gain
0
Btuh
Latent total gain
11615
Btuh
TOTAL GAIN
43626
Btuh
'Key: Window types (Panes - Number and type of panes of glass)
(SHGC - Shading coefficient of glass as SHGC numerical value)
(U - Window U-Factor)
(Irish - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R))
- For Blinds: Assume medium color, half closed
For Draperies: Assume medium weave, half closed
For Roller shades: Assume translucent, half closed
(IS - Insect screen: none(N), Full(F) or Half('%))
(Omt- compass orientation)
EnergyGauge® / USRCZB v6.1.03