PROJECT INFORMATION 5-21-18 - 2
i i +�- wrightsoft® Duct System Summary Entire House QUICK CALCS, INC. • 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS AOL.COM For: LAWSON RESIDENCE, TIC CUSTOM HOMES 5144 CHERRY PALM WAY, PORT ST LUCIE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1550 cfm Job: Date: May 21, 2018 By: 11, Cooling �' v 1.00 in H2Op 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1550 cfm 228 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 I h 1725 77 43 1.000 5.0 Ox 0 VIFx 31.3 135.0 st3 BEDROOM 2 h 5066 226 147 1.000 8.0 Ox0 VIFx 31.5 135.0 st3 BEDROOM 3 c 2635 83 117 1.000 7.0 Ox0 VIFx 19.8 115.0 st1 DEN c 3021 104 134 1.000 7.0 Ox0 VIFx 45.5 115.0 st2 DINING ROOM c 3133 115 139 1.000 7.0 Ox0 VIFx 21.7 115.0 st1 GREAT ROOM c 2778 71 123 1.000 7.0 Ox 0 VIFx 41.3 115.0 st2 GREAT ROOM -A c 2778 71 123 1.000 7.0 Ox 0 VIFx 42.2 115.0 st2 KITCHEN IY c 4249 90 188 1.000 8.0 Ox0 VIFx 23.4 115.0 st1 LAUNDf RM c 1324 4 59 1.000 6.0 Ox 0 VIFx 17.6 115.0 st1 M BATH h 4063 182 93 1.000 7.0 Ox0 VIFx 63.5 135.0 st4 M BEDROOM h 4410 197 150 1.000 8.0 Ox0 VIFx 71.8 155.0 st5 M BED OOM-A h 4410 197 150 1.000 8.0 Ox0 VIFx 73.4 155.0 sty M IwC� h 2297 103 38 1.000 5.0 Ox 0 VIFx 62.3 135.0 st4 M TOILET h 562 25 19 1.000 5.0 Ox 0 VIFx 60.9 135.0 st4 Mwlc I c 614 4 27 1.000 5.0 Ox0 VIFx 62.9 135.0 st4 Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st5 Peak AVF 394 300 1.000 892 9.0 0 x 0 VinlFlx st4 st4 Peak AVF 708 477 1.000 1072 11.0 0 x 0 VinlFlx st2 st2 Peak AVF 955 857 1.000 893 14.0 0 x 0 VinlFlx st3 Peak AVF 303 190 1.000 869 8.0 0 x 0 VinlFlx st1 st1 Peak AVF 595 693 1.000 882 12.0 0 x 0 VinlFlx wri 2018-May-2114:08:35 htsofte ..._ 9 RightSuite® Universal 2017 17.0.08 RSU08101 Page 1 14CCA EADocumnets\Wrightsoft HVAC"WSON RESIDENCE.rup Calc = MJ8 Front Door faces: SW Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox0 1550 1550 0 0 0 0 Ox 0 VIFx 2018-May-21 14:08:35 „ - - wrightSOW Right -Suite® Universal 2017 17.0.08 RSU08101 Page 2 �'� B:\Documnets\Wrightsoft HVAC\LAWSON RESIDENCE.rup Calc = MJ8 Front Door faces: SW i This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.