BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
Date: 31aI:7 / I Permit #: I pe)q — 6 I D co
Contractor: 9es'IA•Z Qu i p -- S
Job �ddress: 3-,Pc/ PAIrk rk 1r33reez_ES Dr
RC=C'cr�iRb
,:9
pesl: Ltrc a ou " erit
Rry
( A New Construction — Complete ( ) Existing —After Addition
House Infiltration Test Results SLC Climate Zone 2
CFI11ll (50) = 793 Test Date:
Volume
ACH (50) = CFM (50) x 60 /Volume = Mechanical Ventilation required less than 3 ACH
Passing results must be & ACH (50) or less W Pass ( ) Fail
FBC,I Energy
The uilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hoursI in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
appdoved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the �welling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
1 CiU11C. %.V111MO11Y
Com any Name: Florida Energy Testing Address: 10" S ZJ P'+gN'V 14ye PS/ 3 y�s3
1 hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
reauirements in accordance with Sectioa.R4Q2.4.1.2 Climate Zone 2.
Name: �S2 �1 1i2�12Gc� � A
#: P1 .SO W 7