Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutTRUSS PAPERWORK4451 ST. LUCIE BLVD
F T PIERCE, FL 34946
0
CrH: 772-409-1010
X: 772-409-1015
wm.Al Truss.com
TRUSS ENGINEERING
BUILDER:
PROJECT:
COUNTY:
RENAR
MORNINGSIDE
ST LUCIE
LOT/BLK/MODEL: LOT:22 /' MODEL:CAYMAN 1763 / ELEV:B3 W/ LANAI
JOB#: 73326
MASTER#: WRMSCMB3L15X10
OPTIONS: LANAI 15X10 (NO VALLEY)
A-1 ROOF
1 TRUSSES
A FLORIDA CORPORATION
Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3
These truss designs rely on lumber values established by others.
I
I
RE: Job WRMSCMB31-15X10 A-1 Roof Trusses
4451 St Lucie Blvd
Fort Pierce, FL 34946
Site Information:
Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE
Lot/Block: Model: CAYMAN 1763
Address: Subdivision:
City: County: St Lucie State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City:
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 0.0
Wind Code: ASCE 7-10 Wind Speed: 160
Roof Load: 37.0 psf Floor Load: 0.0 psf
This package includes 27 individual, dated Truss Design Drawings and 16 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal #
Truss Name
Date
No.
Seal #
Truss Name
Date
No.
Seal #
Truss Name
Date
1
A0118563
A01
8/29/18
13
A0118575
B04
8/29/18
25
A0118587
J2
8/29/18
2
A0118564
A02
8/29/18
14
A0118576
B04GE
8/29/18
26
A0118588
J5
8/29/18
3
A0118565
A03
8/29/18
15
A0118577
C01 G
8/29/18
27
A0118589
T01 GE
8/29/18
4
A0118566
A04
8129/18
16
A0118578
CO2
8/29/18
28
STDL01
STD. DETAIL
8/29/18
5
A0118567
A05
8/29/18
17
A0118579
CO3
8/29/18
29
STDL02
STD. DETAIL
8/29/18
6
A0118566
A06
8/29/18
18
A0118580
C04GE
8/29/18
30
STDL03
STD. DETAIL
8/29/18
7
A0118566
A07
8/29/18
19
A0118581
C05
8/29/18
31
STDL04
STD. DETAIL
8/29/18
8
A0118570
A08
8/29/18
20
A0118582
CJ1
8/29/18
32
STDL05
STD. DETAIL
8/29/18
9
A0118571
A09GE
8/29/18
21
A0118583
CJ3
8/29/18
33
STDL06
STD. DETAIL
8/29/18
10
A0118572
B01GE
8/29/18
22
A0118584
D01
8/29118
34
STDL07
STD. DETAIL
8/29/18
11
A0118573
B02
8/29/18
23
A0118585
1 HJ2
8/29/18
35
STDL08
STD. DETAIL
8/29/18
12
A0118574
B03
8/29/18
24
A0118586
1 HJ5
8/29/18
36
STDL09
I STD. DETAIL
8/29/18,
The truss drawing(s) referenced have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided, byA:1 Roof Trusses,
Ltd.
Truss Design Engineer's Name: Anthony Tombo III
My license renewal date for the state of Florida is February 28,2019.
NOTE.The seal on these drawings indicate acceptance of professional
engineering responsibility solely for the truss components shown.
The suitability and use of components for any particular building is the responsibility of the
building designer, perANSI/TPI4 Sec. 2.
The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the
construction documents (also referred to at times as 'Structural Engineering Documents')
provided by the ,Building Designer indicating the nature and character of the work.
The design criteria therein have been transferred to Anthony Tombo 111 PE by [Al Roof
Trusses or specific location]. These TDDs (also referred to at times as 'Structural
Engineering Documents) are specialty structural component designs and may be part of the
project's deferred or phased submittals. As a Truss Design Engineer (i.e., Specialty
Engineer), the sI al here and on the TDD represents an acceptance of profess ionaAnthony T.
engineering responsibility for the design of the single Truss depicted on the TDD only. The
Building Designer is responsible for and shall coordinate and review the TDDs for
compatibility with their written engineering requirements. Please review all TDDs and all
related notes.
313 BCA22100 000000.4C1287DF
Page 1 of 2
-' A-1 ROOF
TRUSSES
A FLORIDA CORPORATION
RE: Job WRMSCMB3L15X10
No.
Seal #
1
Truss Name
Date
37
STDL10
STD. DETAIL
8/29/18
38
STDL11
STD. DETAIL
8/29/18
39
STDL12
STD. DETAIL
8/29/18
40
STDL13
STD. DETAIL
8/29/18
41
STDL14
STD. DETAIL
8/29/18
42
STDL15
STD. DETAIL
8/29/18
43
STDL16
STD. DETAIL
8/29/18
Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3
These truss designs rely on lumber values established by others.
Page 2 of 2
Job
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE
A0118563
WRMSCMB3L15X10
A01
Roof Special
3
1
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MI I ek industries, Inc. Wen Aug 29 i5:28:4l 20 io rage 1
ID:ld OOXyyT61Bi TXoljwHHzefvK-5T7cHfyYBsNXVOC?UNa5gEVuOlmrw64B7G3LpEyiyuK
7-3-8 11-10-10 , 19-0-0 25-0 4 32-1-9 38 0-0 a9 4,0
7-3 8 4-7-1 7-1-6 6-0-4 7-1-5 5 10-7 i 4 0
6.00 12 5x10 MT20HS=
Dead Load Defl. = 1/8 in
--1
1
m
Iq
17 16 3.00�2
3x6 = 4x6 = 2x4 11 3x4 11 5x12 3x6
= =
38-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL,
in (loc)
I/deft
L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.93
Vert(LL)
0.35 14
>999
360
MT20
244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.88
Vert(CT)
-0.48 11-12
>945
240
MT20HS
187/143
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.99
Horz(CT)
0.30 9
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-MSH
Weight: 222 lb
FT = 10%
LUMBER- I
TOP CHORD 2x4 SP M 30 `Except`
T1: 2x4 SP No.2
BOT CHORD l2x4 SP No.2 *Except*
B2: 2x4 SP No.3, 86: 2x4 SP M 30
WEBS 2x4 SP No.3 *Except*
IW3,W7,W9: 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD I
Rigid ceiling directly applied or 4-2-6 oc bracing.
WEBS !
1 Row at midpt 11-13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS.1 (lb/size)
2 = 1482/0-7-10 (min.0-1-12)
9 = 1482/0-7-10 (min. 0-1-12)
Max Horz
2 =-167(LC 10)
Max Uplift
2 = 370(LC 12)
9 =-368(LC 13)
Max Grav
2 = 1482(LC 1)
9 = 1482(LC 1)
i
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.'
TOP CHORD!
2-3=-2654/1639,3-4=-4224/2520,
4-5=-3578/2091, 5-6=-3485/2116,
6-7=-3262/1858, 7-8=-2382/1529,
8-9=-2684/1736
BOT CHORD
2-17=-1276/2306, 4-15=-211/377,
14-15=-2007/3890, 13-14=-1104/2894,
6-13=-994/214 0, 9-11=-1414/2374
WEBS
3-17=-1304/841, 15-17=-1485/2692,
3-15=-630/1441, 4-14=-767[718,
11 -1 3=-1 424/2784, 7-13=-14/455,
WEBS
3-17=-1304/841, 15-17=-1485/2692,
3-15=-630/1441, 4-14=-767/718,
11-13=-1424/2784, 7-13=-14/455,
7-11 =-I 0061570, 8-11=-389/478,
6-14=-547/700
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 370 lb uplift at
joint 2 and 368 lb uplift at joint 9.
7) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/fPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
�ereiq-nnsenuegH]reilFe(le'Aa Iae; ROSS(Sf'i(llaj 6EA9II RIMSd(OlC1RC6S(BSTOMj RiSI?A(tMCAtI nYiti'Irr¢iatra,apr iueod!n edrtde>I!s srNss Lns Oessga OEnvig(Tf9; us IM Artlnrl, sexes O!t.f.lelwExeRnf FsSresss. Odnsule mood I""iOP,w:p
TS7eitnamrp:e!esslsflFs etrd6, Hs iOOlale.elil. AsrLns Desrye Erpirrrr{I.e,SseFir9A Flgieelp3:s:d Ft n]iOO mnlstets rF[m�dtlil!lpfdlsFittdl,t'eurlee FeyetUlOtl(ie:111lFi i]t1ilefiyFTreeS Alp:a!A se fit TDOnlyWoT.11.The d!sgansmNnn.Ird,poFcaxs,smaltlry Anthony T. Tombo Ill, P.E.
'Jeseeltus Tr 0s gWhi[site Eespxsikila]dtx O.iealhx OvaisEabrak epee r:lbt frileieg MIT.!,. 6a aetnld(u 1A(,ae'a.I.1§.lesttke!&;if,hed KL iie R;mE'rd sic TOD mil r", Wil n .16,1 c"oddgl'ME54A;9"1041h. del ensig sS:lile 6,s resrsc3'.h st
' a80083
aat:Gepges:e,miuswA iA9ie:setsl:pillis6 saFtlkle In;emmee7(lndfskdl171eadSlfAvrnlenmd'n na: dna.RrTfttinsl.:eseuil9:mssskieli!se!tAlLessDesi Ftl�nsOer fnneresllnssflsaelsdF�eE,ness
r.,.1(Weau. Ali n!Is"lot ekIDDIAlir 4451 St. Lucie Blvd.
e3arin AEIIId ljeua'm 1pred 0%r(e Yldleg lJ dl Aat:Ef[Nulls r0psCuplorster if ACT re fa4a1 OWpeGe, T'us SrM14a fapn!er e. yoillij Anmp,-adbcmer ditdhTell. Fort Pierce, FL 34946
topyright®2016A-IRoof Trusses - Amboy 1.Tomha111,P.I. Peprnduai000fAhisdolnment,inanyform,isprohihAedwithmathewrittenpermissionfromA-IP,00fTrusses-Anthonyt.TomhoIII,P.L
Job
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE
WRMSCMB3L15X10
AO2
Scissor
3
1
A0118564
A_1 D—F T--- C— Dr..--
Ce 1—A..,__:__. _,._.__
___
Job Reference (optional)+
!,—, u mn wm is euuaueca, ueo. vveu rsug Zu ID:L6:4L Lu IC
ID:ld OOXvvT61Bi
6.00 12
5x6 =
Dead
Load Dell. = 5116 in
5
5x6 i
T
5x6 1
4
6
1.5x4
W
3
1.5x4
12
1
W
6x8 =
1
N
B
13
14
11 0
1
r
'a
0 1 2
3x8 MT20HS--
3x8 MT20
19
3x4 3.00 12
3x4 zz 1.5xft5ii4 I I
I"
1.5x4 II
4x8 :�:
1.5x4 11
5x8 zz
1.5x4 11
30-9-15
48 /(
9-10.4
19-0-0
27-1.6 2 -1- 2 31 38�0
9-10-4
9-1-12
8-1-6 -0- 2-8-40
7 0-10-10
Plate Offsets (X,Y)—
[2:0-1-14,Edgel [4:0-3-0 0-3-0] f6:0-3-0
0-3-01 [8:0-3-7 Edge] 18.0-4-0 0-5-41 [8.0-2-1 Edgel
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in (loc) I/defl
Ud
PLATES G�IP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.67
Vert(LL)
0.55 12-14 >826
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.84
Vert(CT)
-0.80 12-14 >570
240
MT20HS 187/143
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.93
Horz(CT) 0.50 8 n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-MSH
Weight: 200 lb
u
� = 10 /o
LUMBER -
TOP CHORD 2x4 SP No.2 *Except*
T1: 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3,
Right: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 4-7-10 oc bracing.
Except:
4-8-0 oc bracing: 8-10
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
1482/0-7-10 (min. 0-1-11)
8 =
1482/0-7-10 (min. 0-1-11)
Max Horz
2 =
-166(LC 10)
Max Uplift
2 =
-369(LC 12)
8 =
-369(LC 13)
Max Grav
2 =
1482(LC 1)
8 =
1482(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-4676/2810, 3-4=-4314/2537,
4-5=-3129/1785, 5-6=-3129/1785,
6-7=-4341 /2562, 7-8=-4660/2828
BOT CHORD
2-14=-2402/4233, 13-14=-183113605,
12-13=-1827/3640, 11-12=-1829/3643,
10-11 =-1 842/3607, 8-10=-2418/4245
WEBS
5-12=-1278/2430, 6-12=-850/786,
6-10=-262/633, 7-10=-319/445,
WEBS
5-12=-1278/2430, 6-12=-850/786,
6-10=-262/633, 7-10=-319/445,
4-12=-848/781, 4-14=-257/625,
3-14=-318/465
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf, BCDL=5:Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Bearing at joint(s) 2, 8 considers parallel to grain
value using ANSI/TPI 1 angle to grain formula.
Building designer should verify capacity of bearing
surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 369 lb uplift at
joint 2 and 369 lb uplift at joint 8.
8) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/rPl 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
Gadry •rleese tivreryNp rt!lertk'1I IW RASCi rsffifr, 6C9011 HIM 8 COM:snchs [Dnominna•l.(CrCGiED'>MElfi dxo< ln-dd dWpe pasQden eN rteAnN>f eeSbs lass Ern 7reriy iRwseN ge kdlurl. TcalsDi, rl.ldueas!Fee� leYe ne. Ddesspler+ise stdN entleIDD,raj
FllhkroeeRtsgYa!sldR: end to axIDDSh!dll. As trills Desyn6pttu{Le;SyeeleNp hpces�tlsssdndgddiene TDDadp, eNee Rsi. T�ssirenuapu�.leN�rloeamu,s!aoulrp AnthonyT. ,Tembo 111 P.E.
eAin Wes hessSri" ldliiep is llesespu!ililap 9N%all,IleD+uifea`a�zNe;emrfie IvIfry DWI",, m Eesuted dla ItLi3lS al As load l d4plied Ki.Tle ryrms`: dtie IN afayttld ne dai Tess,i66,1 kad'w•p.ta:rykieshlleBn old Wansuih na re!dtssil:!hd :80083
t
ttxralapDesja�erlQtecal.All es3sWild isNIDD.Al"apmnesradpiidnssetshpdBq(aayamSdeflldavmn;l0fralllsWlpTAoaWAnerdv.xaE:xpeeenlaeaelnlnsoesx:nrpaas1nnWell!scaeTussDlsipx,T:anses'Phpo:erwlrnssra,aen�e!;uuss 4451St. Lucie Blvd.
Fort Pierce, FL 34946
sles.lu IsfisNlparaakN epreederas hxNieg IT dlpatxsh�dsed. iheTnss r[sla Eryiaert Is gCTth Ia/apDez!psw, rtL a Sps'sm hpie.Kr r: ap beddup. !D e�ddaNS!os areas OdaN hRtl.
(opyrighl012016 A-1 loalhosses-Anthony 1. Tomlin 111, R.I. R.eprodudion alibis doromerd, in nay fares, is probiRed withaod the writtea permission bom A -I RaolTmsses- AnthonyL Iambs III, P.E.
Job
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE
WRMSCMB305X10
A03
Scissor
10
1
A0118565
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Aug 29 15:28:42 2018 Page 1
ID:ld_OOXyyT61Bi_TXol jwHHzefvK-Zfh_U?yAy9VN7AnC255KCS27Hi61faJLMwovMgyiyuJ
�1 4-0 7-2-1 12-11-12 19-0-0 25 0� 30-9-15 38-0-0 39-4T
4- 5-9-11 6-0 4 6-0 4 5-9-11 7-2-1 h 4-0
1 6.00 12 5x6 =
4x8 zz
4x8 :
Dead Load Deff. = 5/16 in
LOADING (psi)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.66
Vert(LL)
0.57 12-14
>806
360
MT20
2441190
TCDL 7.0
Lumber DOL
1.25
BC 0.84
Vert(CT)
-0.82 12-14
>557
240
MT20HS
187/143
BCLL 0.0
Rep Stress Incr
YES
WB 0.93
Horz(CT)
0.52 8
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-MSH
Weight: 179 Ib
FT = 10%
LUMBER -
TOP CHORD 12x4 SP No.2 *Except*
T1: 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
WEDGE
Left: 2x4 SP No.3,
Right: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 4-7-7 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS.] (lb/size)
2 =
1482/0-7-10 (min.0-1-11)
8 =
1482/0-7-10 (min.0-1-11)
Max Horz
2 =
-166(LC 10)
Max Uplift
2 =
-369(LC 12)
8 =
-369(LC 13)
Max Grav
2 =
1482(LC 1)
8 =
1482(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-4676/2809, 3-4=-4314/2536,
4-5=-3130/1786, 5-6=-3130/1786,
6-7=-4314/2551, 7-8=-4676/2830
BOT CHORD!
2-14=-2401/4233, 13-14=-1832/3605,
12-13=-1827/3641, 11-12=-1832/3641,
10-11 =-1 837/3605, 8-10=-2423/4233
WEBS
5-12=-1279/2431, 6-12=-848/779,
6-10=-254/625, 7-10=-318/464,
4-12=-848/780, 4-14=-256/625,
3-14=-318/465
WEBS
5-12=-1279/2431, 6-12=-8481779,
6-10=-254/625, 7-10=-318/464,
4-12=-848/780, 4-14=-256/625,
3-14=-318/465
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) All plates are MT20 plates unless otherwise
indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Bearing at joint(s) 2, 8 considers parallel to grain
value using ANSI/TPI 1 angle to grain formula.
Building designer should verify capacity of bearing
surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 369 lb uplift at
joint 2 and 369 lb uplift at joint 8.
8) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
GilIrTEmmums :e'ttsiiliit a , z . . i
Ytl,.ist ndte atlIDD
lreelDn!j,lerTYlxtes
Anthony T. Tombo III, P.E.pustfluneMloot,41 eelTFRt Desipm(
re ue rfdo rrttsSt tq latlirp is lie respns@ilnjdix Or.!r,@e 0-i'S MI'loksl v(Ne Illo it9okm9(PI. Titcpp I'llkIDD are rn lu!I esedtle Tnss.utl!Eq t�d'i^p. sn:sp!, iefi!lefin ultrerri sh>Ii4ef eaimti5:!1je1 180083
' Ill resfq)lsirx:w(lernm.111W4' Sol Wist&1DOulIll prainsall plslwsit4!k1fig(taspolowWolf ! tmnitrn(s¢pilisidsyTo.1sr(Autrt!v xe35!eexre!a:ine IF IMoor oulToss MsrAtar:e!;a ss 4451 St. Lucie Blvd.
R!RiSt Idilsl IJeG>txd YJfH/ aHe fr Ylaler iJdIpM:Ff INFrtl. Tit TlttS rYff,'-I(Sri1N! li ICTRL (2i19j DKiT1C,rt T.t.f Syi'!Z �j t.Yf r®j Nlijl3r. JJI!C]-�aMteras tre es detael nlrll.
Copyright 02016A-I Roof Irusses -Anthony L Tombri [if, P.E. Reprobation of this dommerri, in any form, is pirlhillfted without the witless permission from A-1 Roof Tresses -Anthony 1. Tomb D 111, M. Fort Pierce, FL 34946
15X101A04 I ROOF SPECIAL
Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18
4
182018
MORN
AO118566
6.00 12 7x6 II
its 1d 410 = --
1.
3x6 = 5x6 = 2x4 11 1.5x4 11 3.00112 3x8 Zz
8x8 = 1.5x4 11
11-7-10 21-2-10 23-3-2
8-1-0 11-1-10 19-0-0 0-11-1 234}2 29.6.0 38-0.0
8-1-0 3-0-10 0 0 7-0-6 1-11-i 1-9-8 6-2-14 8-&0
Aug
Dead Load Defi. = 3/16 in
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.93
Vert(LL)
0.4711-12
>974
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.85
Vert(CT)
-0.65 11-12
>699
240
BCLL 0.0 "
Rep Stress Incr
YES
WB 1.00
Horz(CT)
0.36 9
n/a
n/a
BCDL 10.0
Code FBC2017frP12014
Matrix-MSH
Weight: 222 lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2 "Except"
T1,T4: 2x4 SP M 30
BOT CHORD 2x4 SP No.2 "Except"
B2,B4: 2x4 SP No.3, B5: 2x4 SP M 30
WEBS 2x4 SP No.3 "Except'
W6: 2x4 SP No.2
OTHERS 2x4 SP No.3
.BRACING -
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD
Rigid ceiling directly applied or 4-9-3 oc bracing. Except:
10-0-0 oc bracing: 15-17
WEBS
1 Row at midpt
4-14, 6-14, 6-12
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
1491/0-7-10 (min.0-1-12)
9 =
1485/0-7-10 (min. 0-1-11)
Max Horz
2 =
-166(LC 10)
Max Uplift
2 =
-365(LC 12)
9 =
-367(LC 13)
Max Grav
2 =
1491(LC 1)
9 =
1485(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-2635/1604, 3-4=-2700/1747,
4-5=-1822/1223, 5-6=-1717/1250,
6-7=-3863/2402, 7-8=-4601 /2946,
8-9=4661 /2731
BOT CHORD
2-18=-1233/2282, 4-15=-310/655,
14-15=-1254/2423,7-12=-511/558,
11 -1 2=-1 678/3630, 9-11=-2320/4205
WEBS
3-18=-466/340, 15-18=-1123/2282,
WEBS
3-18=-466/340, 15-18=-1123/2282,
4-14=-1036/801, 6-14=-492/98,
7-11=-794/860, 8-11=-352/502,
12-14=-685/1887, 6-12=-1708/3244
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsf, h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4) " This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Bearing atjoint(s) 9 considers parallel to grain value
using ANSI/TPI 1 angle to grain formula. Building
designer should verify capacity of bearing surface.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 365 lb uplift at
joint 2 and 367 lb uplift at joint 9.
7) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
Krrh tlan5tntim!rerirrih'4111300MSr5{'iELIEI'p 6f1•JI(RLMS8[0pC1005S(DSIONj tD10')tCCrGG'�DSSIfXi'lua Tuei dtsiyt putntltn tsd n:3 tsfnnirisUtss OesADresiyER td IhleiverIIvele.rl.!dress 4?slF<.`e!e ns. adeuethniserisul It titTDD".it
Wiek ntnmq%!esse>lihatelin lle1013koue.Ise Tins Des1pef.V.u(ie,5peJ,4 ftpi.uItsndnnp100 repruers tr.uugm;edtle polssieeelegttrno nsputiillor kftldssrnetues!qeTress hp!nedtelleIDDodp, eMerIMI.Thdes!tenttnptitn,ltdqutdons,stildliq Anthony T. ;TorribD III, P.E.
d uedrSs 12ss5rtq ldiditp is Ike «3pntilil49h,0ss¢fie 0-es.:midipeirik lrldiu 0esipt+r,miSendendiSr ltC, �eBfoodtle 6ldEm@quit M.
Tte it/me'edtle]DD asl n.fieldnedh: Tnss,Sadetiq Wd;;„}s�repe. irshileliet udkra, sSdifa Na repsav'susrel fi. $0083
Ih t"Vfts"! W 11INdr. At uns ut ac u IN TDD W Ike pasi ns ms pd9nes this kidiq (taptat SrIe l lfnsttin70f,: 1.11"W 4 0l and SlfA tr_re —tifee punei ge dnee 110 h5usSe:nprs l:an Liddi3?e tf'�e TIn3 Denptef,l:nsDli p Fegii'HC➢d T(eii pSpdt;4!!e, tt'eii
tltniu lifited tpa04:tele eed tpvumint t dl trtm ltseiud. lSeTuss Cr9?eF items rDTih lAaiz vesi rer,nTnssS .-xfaritxrdmrSeilS. tJl datdk:rn mndbaei ialfld. 4451 St. Lucie Blvd.
• p t r r r• d M i q Fort Pierce, FL 34946
Copyrigh102016A-IReofTiusses- Anthony LTanabe Ill, P.E. Reprodurtionofibisdommenl,inanyfum,ispmhibhedwithoutthewrittenpermissionfromA-]R6DITtusses-AnthonyLTomho111,P.E.
Job
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE
A0118567
WRMSCM63L15X10
A05
HIP CAT
1
1
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@aitruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Aug 29 15:28:44 2018 Page 1
ID:Id OOXyyT61Bi TXoljwHHzefvK-V2plvg_RUnl5MUxa9V8olt7S6Wn37V2epEHOQYyiyuH
20-11-10—
1� 0 6-1-11 11-1-10 18 0 12 19 11 4 i 23 3-2 1 30 4 11 _ 38-0.0 39� 0
1 6-1-11 4-11-15 6-11-2 1-10-8 2-3, 7-1-9 ' 7-7-5 '1-0-0
1-0-6
6.00 F12 5x6 = 6x6 = Dead Load Defl. = 3116 in
" 3x4 =
3x6 = 6x6 = 3x4 11 4x6 =
8x8 =
1.5x4 11 3.00[12 4x8
1.5x4 II
20-11-193-0-2
i 6-1-11 i
11-1-10 11710
18-0-12
i19-11-421t1023r3-2 30-4-11
i 38-0-0 _
6
4-11-15 0 0
6-5-2
1-10-8 0- 0 0- 0 7-1-9
7-7-5
1-0-6 1-9-8
Plate Offsets (X Y)—
[4:0-5-0 0-3-01 [5:0-3-0 0-2-0] [6:0-3-00-2-01 [8:0-1-15 0-0-0] [9:0-0-0 0-1-121 i9:0-3-0,Edge],[10:0-1-14,Edgel,[13:0-6-0,04-12],[17:0-5-12,0-4-41
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC
0.71
Vert(LL) 0.47 12-13 >968
360
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC
0.85
Vert(CT) -0.67 12-13 >681
240
MT20HS
187/143
BCLL 0.0
Rep Stress Incr YES
WB
0.85
Horz(CT) 0.37 10 n/a
n/a
BCDL 10.0
Code FBC20171TP12014
Matrix-MSH
Weight: 236 Ib
FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2 *Except*
T4,T5: 2x4 SP M 30
BOT CHORD ,2x4 SP No.2 *Except*
B2,B4: 2x4 SP No.3, B5: 2x4 SP M 30
WEBS 2x4 SP No.3 *Except*
I W6: 2x4 SP No.2
OTHERS 2x4 SP No.3
WEDGE
Right: 2x4 SP �No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-8-8 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 4-8-13 oc bracing.
Except:
10-0-0 oc bracing: 17-19
WEBS
1 Row at midpt
4-16, 6-15, 7-12, 6-13
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
1491/0-7-10 (min.0-1-12)
10 =
1485/0-7-10 (min.0-1-11)
Max Horz
2 =
-159(LC 10)
Max Uplift
2 =
-359(LC 12)
10 =
-362(LC 13)
Max Grav
2 =
1491(LC 1)
10 =
1485(LC 1)
I
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORDI
2-3=-2721/1649, 3-4=-2697/1687,
4-5=-1876/121 7, 5-6=-1602/1239,
6-7=-3879/2412, 7-8=-4665/2991,
8-9=-4517/2738, 9-10=-4689/2737
BOT CHORD,
2-20=-1302/2377, 4-17=-229/596,
BOT CHORD
2-20=-1302/2377, 4-17=-229/596,
16-17=-1224/2404, 15-16=-615/1602,
7-13=532/615,12-13=-1677/3640,
10-12=-2333/4230
WEBS
3-20=-267/251,17-20=-1179/2225,
4-16=-975/739, 5-16=-267/546,
6-15=-1358/503, 7-12=-839/887,
8-12=-344/505, 13-15=-823/2180,
6-13=-1821 /3504
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) All plates are MT20 plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6) * This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
7) Bearing at joint(s) 10 considers parallel to grain
value using ANSI/TPI 1 angle to grain formula.
Building designer should verify capacity of bearing
surface.
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 359 lb uplift at
joint 2 and 362 lb uplift at joint 10.
9) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
t6'edq �Plee:etleargdrrell}esL'0.�1 iD@i BiSSdi'irtlEl'j 6tg021 iE1NSd(Pti iiICSS fiIS70kj Eli9;!(CYCd1FiMEMi IIf'F-IlilFtt}{�rI rEI9Ntf50itR�eN3Sp iilS ilk!fDP!CI)!1e1q 11C4j RP ItS AINpri. TYSYILI,r.E.MGIEf ir!}I tYS:'IRY. IItIY!1 dtN*Ift CeIN 1E1�11DD,f*'(
tll4ioen:br/aas sSd:FYrelfirfte iDDlekYdiL beLns De:yl Elpwrpa.$endlr FYpu S!s!dnnrlDO!eFtesYAsfe raadtle palssludfq'eerise r!ynsililot'm;lsetn:ga<ittt sane Tn!st!rm!Ifctle lDD nlr, Neri?Fl.i&t!DYYsnnp�fc.lersxgort�nxs,smoi�Dry Anthony T. Tombo III, P.E.
d+st.1*1 sshrfg Wblislte restBevlflmdGeOnee,CeO.xiseas'i!flly`tdiftia ldttiq Oesilcer,atz cxMrtdlie lK,A!�SE felBe btd ea':4ryn1}a3 rd-1. ile Rinsfief!se lDDeaemfid[ne Alie Tnss. 6tiq Ral:iq.Pi:gf, I15hII@IIB Gt GrIr3j1S1✓ill:il rY!rcaibLhd z80083
Arta 6Ffag Dfs!gm:ectQd'emcINW's!eteetll fee Mel l'nrr!dnesml p,Hmsd9e tell§I Cmpea Sdery la3wdielp•Effj peGsE 4TA letSKA.rerehrzxeta}p¢nely iAntr. lPeT tfire!d:restYni4:DAes[etGe!L•sd!!!1!Yss Muifer,irt3s Desge Feiia!YrwlinssU�oden�er,seess 4451 St. Lucie Blvd.
BRe!YIitHad kJo—TdgedA.lte.1h]iy61pm,s1.,I1.TSYTr1YsNip ElltHeefli!ICIetLA1t9j0HIt3U,ofirl!SSri!IIEatif!erdmrlr0§fr.kltq:lai!!Y:OSIteadd.YttiTftl. Fort Pierce, FL 34946
(opyrighl02016A-IEtoofhosses-AnlhonyT.lomboIll. P.E. Reproduction of this dornment, in any form, is pichibined without the written permission hom A -I Roallrosses - Actfronyl. Tomb III, P.E.
Job
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE
WRMSCMB31-15X10
A06
HIP CAT
1
1
A0118568
Cl
f
Job Reference (optional)
��s
34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Aug 29 15:28:45 2018 Page 1
ID:ld_OOXyyT61Bi TXoljwHHzefvK-zEN770?3F4ty_dWnjDflg4gtww58sxin2ulZy?yiyuG
23-3-2
1 6-1-1 11-1-10 16-112 2 :11-10 2 -11 30-4-11 36-0-0 9
1 6-1-1 539 4-11-2 410-14 0.11- 0 7-1-9 7-7-5 -0-
1314
i
Dead Load Defl. = 114 in
a _ ,
5x10 % 5x8 II
6.00 12 3x4 II
3x6 = 6x6 = 3x4 II
8x8 =
3x4 = 1.5x4 11 4x8
3.00 12
zz
7x8 =
A-d' 2
6-1-1 11-1-10 11 7 10 16-0-12 20-11-10 21 -1 23 2 30b11 38-0.0
6-1-1 5-0-9 0�-0 4-5.2 4-10.14 0- -0 0- 0 7-1-9 7-7-5
0-8-10
14a
Plate Offsets (X,Y)— 17.0-2-4,0-2-81 [10:0-1-14 Edge] [13:0-7-0 0-3-101 [15:0-1-12
0-2-01 [17:0-5-12 0-4-41
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.64
Vert(LL) -0.52 12-13 >869 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.98
Vert(CT) -0.77 12-13 >590 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.95
Horz(CT) 0.49 10 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-MSH
Weight: 236 lb = 10%
LUMBER -
TOP CHORD 2x4 SP M 30 'Except'
T3: 2x4 SP No.2
BOT CHORD 2x4 SP No.2 *Except*
132,134: 2x4 SP No.3, B5: 2x4 SP M 30
WEBS 2x4 SP No.3 *Except*
W5,W7: 2x4 SP No.2, W8: 2x4 SP M 30
OTHERS 2x4 SP No.3
WEDGE
Right: 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-8-6 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 4-8-13 oc bracing.
Except:
10-0-0 oc bracing: 17-19
WEBS
1 Row at midpt 6-15
2 Rows at 1/3 pts 7-15
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 = 1491/0-7-10 (min. 0-1-12)
10 = 1485/0-7-10 (min. 0-1-11)
Max Horz
2 =-142(LC 10)
Max Uplift
2 =-346(LC 12)
10 =-349(LC 13)
Max Grav
2 = 1491(LC 1)
10 = 1485(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-2727/1634, 3-4=-2685/1640,
4-5=-2622/1657, 5-6=-2044/1363,
6-7=-1783/1297, 7-8=-3589/2235,
8-9=-3752/2106, 9-10=-4708/2721
BOT CHORD
2-20=-1293/2384, 5-17=-256/572,
BOT CHORD
2-20=-1293/2384, 5-17=-256/572,
16-17=-1168/2365, 16-31=-734/1782,
15-31=-734/1782, 8-13=-231/391,
12-13=-2324/4260, 10-12=-2320/4250
WEBS
3-20=-266/257, 17-20=-1203/2211,
5-16=-810/602, 6-16=-316/617,
7-15=-3715/1603, 9-13=-8791776,
9-12=0/281, 7-13=2586/5316,
13A 5=-1702/4204
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces 8 MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent•with any other live
loads.
5) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
6) Bearing at joint(s) 10 considers parallel to grain
value using ANSI/TPI 1 angle to grain formula.
Building designer should verify capacity of bearing
surface.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 346 lb uplift at
joint 2 and 349 lb uplift at joint 10.
8) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/1'PI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
wt�dq•nnsenunsllye!dextk•iaraelnais'SisrunZrtanurdrxsaral:ancssesstDx{rsTn';ztraohusu�rt'tnm.re;apses;;,rotas!rse,rya.x!sntasr,sssoe:c,Drt~iepfrre;:n3Leadlnfl.r:�sc;.r.Lrde,ewes:.ttanes!.udnsd�.indddnn!1DD,.,q
milduensn,pices sldlE: osed6rLe IODukolll. IseTrms Dnipa hNrze;LespeshNp 0[srs r15!sul eeeryIDOsepresertsnsaepeaad14e pmt!ssHtd er{3e!rlea ns,nNlllar`:ursSe ess:(ntd Le sls�"yeTnss hpin!hetle IDD a¢, eet!rITT. The dKI'malava , fithp.dnls, soidOry
rd in dsps Tani, of Hielstknsnsililded;.e Mu.11e O—es 1e; Lel hil Dmia!, m h ndsd d(a K,is LKWthe Lad Us ale Mi. The ,ne dLe TOD nl tntield ese d60"st. We6etead5 f Onuihfin ud Isa 6MI M1,!ro ti3:!:hd Anthony T.'TOmbO III, P.E.
' r r E 1 er' �1s w s 80083
IleM:layOei;m:en!QC�esq!.sl: nns sdodiLeTODexlek pr�iusalpildnudtL•tnidq[snpcaen klegia`tinenn;xsr peNisWly ltl ts/1lfauerelv:xterx pnni pdsu:, TYrIG0ns4!resµn h;laiesne6"!sd!h!LtssDesipu,l:tts 7esa kp2erwl Gnckmdt^eey nrus 44$1 St. Lucie Blvd.
t#sMu ldissllpoiesPed eptrsd eptt uvnOq lTdl pen s i!s;Tul ThtTnss edafspiu l is icTN IA*.dnr Dtslpv t,lm!s sp1!s Ea) ese drJp lediq, "aupd1elte en laoi ddsedulPN.
Cnppliaht02DI6A-IRoefLusses-Anlhanyl.TomhoIII, P.I. Reproduetionofibis domment,inonyform,isprohibited without The writtetpeemissionhomA-IRoofliusses- Anthony LTomb III, P.L Fort Pierre, FL 34946
Job
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE
A0118569
WRMSGMB3L15X10
A07
Hip Structural Gable
1
1
Job Reference o tional
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s
6.00 F12 5x6 =
3x4 =
7
2-11-10
5x10 MT20HS:z
8 2018 MiTek Industries, Inc. Wed Aug 29 15:28:45 2018 Page 1
IIwHHzefvK-zEN770?3F4ty_dWnjDfl g4gegw86s3Cn2ulZy?yiyuG
22 21--- 3x8 = — 17 15 13
3x6 — 4x4 = 2x4 II 18
16 14 1.5x4 ii
4x6 H 3x6 3x6 =
5x6 =
23-11-4
LOADING(psf;)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defy
Ud
TCLL
20.0
Plate Grip DOL
1.25
TC 0.64
Vert(LL)
0.13 13-28
>771
360
TCDL
7.0
Lumber DOL
1.25
BC 0.79
Vert(CT)
-0.34 18-19
>808
240
BCLL
0.0 '
Rep Stress Incr
YES
WB 0.40
Horz(CT)
0.01 15
n/a
n/a
BCDL
10.0
Code FBC2017/TP12014
Matrix-MSH
LUMBER- ;
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2 *Except*
I B2 135: 2x4 SP No.3
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-6-6 oc
purlins.
BOT CHORD I
Rigid ceiling directly applied or 6-0-0 oc bracing. Except:
4-1-0 oc bracing: 15-18
WEBS
1 Row at midpt 7-18
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in I
accordance with Stabilizer Installation quide.
REACTIONS!All bearings 14-11-10 except (jt=length)
2=0-7-10, 16 0-3-8.
(lb) - Max Horz
2=-126(LC 10)
Max Uplift
All uplift 100 lb or less at joint(s) 16
except 2,-247(LC 12), 15=-365(LC 9),
13=-158(LC 13), 11=-148(LC 13)
Max Grav
All reactions 250 lb or less at joint(s)
16 except 2=854(LC 23), 15=1662(LC 1),
13=345(LC 24), 11=330(LC 24),
11=304(111, C 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-1301/888, 3-4=-966/759,
4-5=-896/7751, 5-6=-675/650,
6-7=-577/617, 7-8=0/442, 8-9=0/509,
9-10=-7/403 1
BOT CHORD
2-22=-603/11,05, 5-20=-277/376,
19-20=-326/802, 15-18=-1300/640,
8-18=-421 /2114
WEBS
20-22=-596N�007, 3-20=-348/338,
WEBS
20-22=-596/1007, 3-20=-348/338,
5-19=487/462, 7-19=-225/634,
7-18=-984/583, 10-15=-392/336
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) All plates are MT20 plates unless otherwise
indicated.
5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
6) ' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.Opsf.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) 16 except (jt=lb) 2=247, 15=365, 13=158,
11=148, 11=148.
8) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
Dead Load Defl. = 1116 in
PLATES GRIP
MT20 244/190
MT20HS 187/143
Weight: 220 Ib FT = 10%
�Ytioap•Nwst!trtx�l1!plt�tlt'1?IF77?rOiSES(S1f!1';.F(Nrn(7;Li!SIiCXff�Ng(li1CY�MFt"R(CA7N1F0=.YfS!'!re. Ru!rbnprstaxes ttlftag tdtstetl'tTms6t:!Itbt.ig(IOPlel6:k'Mtgf.ltahl[,r.[.Itrertef!iLtl lehrtev_!l�rio!fn.ia tYNta",.sTC-0, itlr
qi?ttmnertu gldss tit9 ieesedfm5e76: hll tttii dstlmt Gti;,l:Jj3ttf(11.. Spt }Yl)�iti!,>9t5Nu to ttg r�itytibYt �9'(igttltt allf r!t!KS3t3 Ry0!G jIt5P40i 'ihil:±d3Sl�t d!14513g!tTit:t i•:gLhdt0 27 BitIy,R[�Y!IFI. !A2 gt5igi /5it3g'!W; wag OE°.^.DNS: SR! v'Ar Anthony T. Tombo IN P.E.
etdat Y rbs 7Nss tar of Nl Viobtrupm�i,010rxa6t OctetadmNiq'mNtitgr.'.<.pCr,�>r,pfat two sins 114It, Ktdfrt Iml P&I Or ng7Nfl Tat trpmel a!4:li�O ni ar Gdgut tt l}tTnss;h:,rYsgtrtitrtg. stm fit, its't?,�te sl4n:tg dtO tt at mrasi"sill t{ T80083
Ct 1W.1 Puiptf and rte!fa:tt(, d11WNW*405t72.4fat grtmtts Nd rl".'n 0Itrt:-Ggt&Apuw soil" Y?A129`NVVgIttlotdWflttd 51a Nt rr<'waa fat I.!d 1.4m. 141 leuh, mprillL`t, df is t!It T— home, itnr Uvv hgnu tad Tolt YNtlten-, w!tss 4451 St. Luele Blvd.
' �ttttiE!sr MiN!!rt(tadrl tpedrytau*r'gty z;galin U!dtd. i4Lta Fesi3a Eetm is �Oi lttTuldirg Otsigu.t!'!aufrrlea EAgiar, el nyl�ulnq.f!i myift!iizl L>!sr at es dt�etg itlNl. For, Pierce, FL 34946
(c thIC2016A�IRoofTrusses•Aothoo I.Iomhalll,1`1 Rercdufti000fibisdoturneot,fnco form, is prohibited ermissiocfmmAdRoofTrusses-Anihon 1. Torch (11,P.(.
PY 9 Y P Y P F Y
Ply IRENAR MORNINGSIDE
AO118570
f russ Truss T
WRMSCMB3L15X10 A08 Hip
A-1 Roof Trusses, Fort.Pierce, FL 34946, design@aitruss.00m
1-2
5x6 =
3x4 =
18 2018 Print: 8.210 s May 18 2018 Mi ek Industries, Inc. Wed Aug 29'15:28:46 2018 Page 1
dd_0OXyyT61Bi TXoljwHHzefvK-RRwVKM?h0O?pbn5zHwAGNICpSJTubRmwGYm6VRyiyuF
25-54 30-1 n-3 4 Awn 1 1. 1 .,
5x6 =
bead Load Defl. =1/8 in
LOADING (psf)
TCLL 20.0
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
PLATES GRIP
TCDL 7.0
Plate Grip DOL
Lumber DOL
1.25
1.25
TC 0.65
Vert(LL)
-0.32 12-14
>884
360
MT20 2
4/190
BCLL 0.0 '
Rep Stress Incr
YES
BC 0.89
WB 0.70
Vert(CT)
Horz(CT)
-0.45 12-14
0.02 12
>616
_ n/a
240
n/a
I .
BCDL 10.0
Code FBC2017/TP12014
Matrix-MSH
Weight: 196 Ib
C
FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 4-5-4 oc
puffins..
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS
1 Row at midpt 5-12, 6-10
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
777/0-7-10 (min. 0-1-8)
12 =
'1828/0-7-10 (min. 0-2-3)
8 =
358/0-7-10 (min. 0-1-8)
Max Horz
2 =
-114(LC 10)
Max Uplift
2 =
-219(LC 12)
12 =
-553(LC 9)
8 =
-248(LC 8)
Max Grav
2 =
807(LC 23)
12 =
1828(LC 1)
8 =
413(LC 24)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-1151/588, 3-4=-682/381,
4-5=-540/390, 5-6=-318/606,
6-7=-321/762, 7-8=-313/516
BOT CHORD
2-15=-326/963, 14-15=-326/963,
13-14=-31/276, 13-22=31/276,
22-23=-31/276, 12-23=-31/276,
11-12=-348/498, 11-24=-348/498,
24-25=-348/498, 10-25=-348/498,
8-10=-298/219
WEBS
3-14=-533/508, 5-14=-293/582,
WEBS
3-14=-533/508, 5-14=-293/582,
5-12=-1109/793, 6-12=-823/911,
6-10=-1196/706, 7-10=-373/512
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=42psf; BCDL=S.Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Provide adequate drainage to prevent water
ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
5) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members, with BCDL =
10.0psf.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except Qt=lb) 2=219, 12=553, 8=248.
7) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
6'r.Nq-rlKse tltngdrrnietrtSe'4.I10c, n755E5{'i(tlfC16Ee31t fE(NS d (06.I' II[i4(DS70Mj K9�';L(rlGRTQGNEAI EN8 INA(.ttilrl iNE6NtK IJd iM(O]ItS OE131IT!E33 DES!C! DItMltrfl('Dj N� Itt 1NIN(T. TMlt Ell r.E.ItidtAt �tY1 Al'tKt, Dd"s t hmit slisi n Sit
ILrh°vtt33t3 r!6es slilile Keifrt Hx iDDl3kWd. As a Tins DtslftEtpted{I.e.S,tEldf(itEiud;,Eie 3ed 110rTDD(trrKm4tG N3tr."n:l Aftl rSEi?SSI91A lCr'if!.IEEI23fN31ilI1F(bt Ml lKiifi Re slE�,efisdetmelmtle lDD etIr; EMd1iH. Ttx e!v'n n3Enp31tK.ItdeptnN�nx3,tmtNEst AnthonyT. T T
Vin"M tinsle'" ldf .5 islk IterN3lfelhdf:d D'�121-ift D'�'dfffA40!IIFIF ANtitlAf/he DKlreN,®htflMEl Alft(K V11191Ne dtdtadmaltad RLl. ile yfn!tldlie 106 osd nrM1Tll nedHe Tess. rtiq t�s'�c}sn:gt.�tmnditt wtt,Nsr sSditaren3pa4D�lha Y embo II-, A.E.
t INN'taDUefirt:Nlfsa oll.Au4sill01itmeIDD.4itrim!°,®(rEAA°Kdth1.1Gq(mrcamStill1*m¢nwtLfftNitaitJ(tlMs(flNanh!lotlMmdnprAnelfHkx3ttenspmt:nESWb3N�a11EKDt d,11K3DKi �80083
;• pugeNwl T°slMmlrt:Nd,waK 4451 St. Lucie Blvd.
t3crtlu ltfdtlira(mkm tpet4 tyttuxntiq lydtrtmKlKAsei 11eT°ss DeslpsEa(iteetts AOft�ts�arDKfr3d,xTnszsrsha (tritttrd®r MlSur_ Ali Scp.':aNar°s demld!ad itlrFl. Fort Pierce, FL 34946
Eopyripht02016A-I Roof Trusses -AnEhonyI.Tomholl],P.E. ReproducIlionofthis dommenyinany form, isprohibited with out the written permission from A4 Rest Trusses • Anthony 1.TombnIll, P.E.
Job
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE
A0118571
WRMSCMB3L15X10
A09GE
HIP SUPPORTED GABLE
1
1
Job Reference o tional
A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Aug 29 15:28:47 2018 Page 1
ID:Id_0OXyyT61Bi TXo1jwHHzefvK-vdUtYiOJni7gDxf9rehVvVl?FjvXKxb4VCWgltyiyuE
r14-9 11-0-12 26-11-4 32-2-8 38-08 $9-4-Q
1 00 11-0-12 15-10-8 5-3 4 5-9-8 14
5x6 =
5x6 =
31 30 29 28 27 26 25 24 23 22 21 20 19 3x4 —
3x6 = 3x6
24-9-8
LOADING(psf)
SPACING-
2-0-0
CS1.
DEFL.
in (loc)
I/defl
Lid
TCLL 20.2
Plate Grip DOL
1.25
TC 0.59
Vert(LL)
0.47 16-18
>379
360
TCDL 7.0,
Lumber DOL
1.25
BC 0.48
Vert(CT)
-0.36 16-18
>492
240
BCLL 0.6
Rep Stress Incr
YES
WB 0.54
Horz(CT)
0.01 19
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix-SH
LUMBER -
TOP CHORD ?x4 SP No.2
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing,
Except:
10-0-0 oc bracing: 18-19
8-3-13 oc bracing: 16-18.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. All bearings 23-8-0 except Qt=length)
16=0-7-10.
(lb) - Max Hori
2=-102(LC 10)
Max Uplifs
All uplift 100 lb or less at joint(s) 2,
21, 22, 23, 25, 26, 27, 28, 29 except
19=-381(111 C 8), 30=-116(LC 12),
16=-288(LC 8)
Max Gran
All reactions 250 lb or less at joint(s)
2, 21, 22i 23, 25, 26, 27, 28, 29, 30,
31 except19=681(LC 24), 16=593(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD;
14-15=-335/528, 15-16=-661/799
BOT CHORD,
29-30=-150/382, 28-29=-150/382,
27-28=-150/382, 26-27=-149/380,
25-26=-149/380, 24-25=-149/380,
23-24=-149/380, 22-23=-149/380,
21-22=-149/380, 20-21=-149/380,
19-20=-149/380, 16-18=-597/551
WEBS 1
14-19=-594/823, 14-18=-677/471,
WEBS
14-19=-594/823, 14-18=-677/471,
15-18=-363/528, 3-30=-116/252
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. ll; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed; porch left
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the
truss only. For studs exposed to wind (normal to the
face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as
per ANSI/TPI 1.
4) Provide adequate drainage to prevent water
ponding.
5) All plates are 1.5x4 MT20 unless otherwise
indicated.
6) Plates checked for a plus or minus 0 degree
rotation about its center.
7) Gable studs spaced at 2-0-0 oc.
8) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
9)' This truss has been designed for a live load of
20.0psf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
10) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) 2, 21, 22, 23, 25, 26, 27, 28, 29 except (jt=lb)
19=381, 30=116, 16=288.
11) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
AN81/TPI 1, The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
Dead Load Defl. = 1/8 in
PLATES GRIP
MT20 244/190
Weight: 235 lb FT = 0%
iffl %t01F:Ri1V.$ilf eFi!FYfit�r rDD(rluuEii$!t!9',eirtUt i9k$tiDrD;rurs tD1TL'A^ro!rr^ziuosum�$:sr P.1,14"1110psaea:.1it!ib!Ff"INS r1Fi1 Dr1ip D'rslgriDDk!44!4.Mt1rr6.y1 RUE leff'Si!S!Inh6re eft. 1�5tt er+nrisF fYxifa EFTDD,my
dHhtlFGu rlFiFsfSa:7setulkr?§!IDDnk!1�iA tsll.a!1CF;(1;1ja:F1{!2.,$rFC�27EGj'9?J;R!1F'{K6rIS IfgFH51mXFFriH(!G'3$ifll1Fk80ij9!FILJtF1ri8Yk!3frHFdlilp ll fN fli?!!IMfl:rl^22NSF$ZF!!r,pp}F(IrFI.Ib!IFfir6!1P3j`C21; �i0161F''itfff?ai!ih Anthony T. Tombo FF:, P.E.
eMt!eniticlrsl4,farr.iaf:l anlft+a'n.`iTtlttklN"?,k,O.W'stlS111tlq(nV6,1':zrr:p.!.itfitxrtFtel41 lit lit RfvASSelx11D1CfugrtdlnoliN.1,i$f!rrnlilaltE!t:D!el•stitlf!1!FttfrFIris,i!Ik:!y»!slur.nmgF.+ s7us7!"ttN3fYan$!P!fF19�fi5il'fPI 80083
ne r.Jfq D!npv �l,eetrutFc rlia.^.p u1FMa7FT^.-?mifkl p!cul celrr3!:sniaftFra��rasNf�iStAidorl•^.:Fa{l;i!!.'!.':9dk. itiulS6CIf wF;c'eF!iFi;s: ret;ci rarexl, r?41 Lam1G!1Firiuis�l::`:o-iratld,Ff!15!r:titFrc:r•; f1r11 CFsiy r!gcFet mdinll NaAk�F6�';1s 4451 St. Lucie Blvd.
Rn.i:r Idw!/rt(w5rl q,;eigwn�i_!gkp e;ifttlits h!ehti. ih ri!11 DIf"rye57am is e0;fit 10141Dt1lp(r,v firs,Sys4iz rqur0m; k1of"r. UtFfatNAfira!at!s itlurd i Ms.
taPyfigSt�.'.'2016A-1Rwlimstes-Arrkanyi.Fsm6xi11,P.E. fiep,cduliunottF.isdc(nmeei;ioanyfArm,isplohibGedwitEoulihel!!ittenpe,missiomn,mAdFoatlm!fes.AniScayT.Tom6n116P.F. Fort Pierce, FL 34946
Job
Truss
Truss Type
QtY
PIY
RENAR MORNINGSIDE
WRMSCMB3L15X10
B01 GE
COMMON SUPPORTED GAB
1
1
A0118572
A-1 P-f Tn-- P-1 Pi-
GI '2AOAn A--i,...(,..,....__
_
Job Reference (optional)
-•--------... -. �� c�,1,11-U-IVAIGIlia uem yrocuroKuu5mes,Inc. vvea
ID:Id_0
OXyyT61Bi WTXoljwHHzefvK-Np2F121xY?FXr5ELOLC
-1-4-0 6-2-0 12-4-0 1
1-4 6-2-0 6-2-0
4x4 =
5
6.00 F12 6
4 n
3 : T�' I Sri T� 7
• ,, = $T2 i $T2
f ST� �.
3x4 = 14
LOADING(psf) SPACING- 2-0-0
TCLL 20.0 Plate Grip DOL 1.25
TCDL 7.0 Lumber DOL 1.25
BCLL 0.0 ' Rep Stress Incr YES
BCDL 10.0 Code FBC2017/TP12014
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. All bearings 124-0.
(lb) - Max Horz
2= -62(LC 10)
Max Uplift
All uplift 100 lb or less at joint(s) 2,
8,13,14,11,10
Max Grav
All reactions 250 lb or less at joint(s)
2,8,12,13,14,11,10
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the
truss only. For studs exposed to wind (normal to the
face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as per
ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom
chord live Load nonconcurrent with;any other live loads.
13 12 11 10 3x4 =
CSI.
DEFL.
I in
(loc)
I/defl
Ud
TC 0.18
Vert(LL)
-0.01
9
n/r
90
BC 0.09
Vert(CT)
-0.01
9
n/r
80
WB 0.05
Horz(CT)
0.00
8
n/a
n/a
Matrix-SH
Wind(LL)
0.01
9
n/r
120
8)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
9) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) 2, 8, 13, 14, 11, 10.
10) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI,TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
29 15:28:48 2018 Pagel
PLATES GRIP
MT20 2441190
Weight: 56 lb FT =10%
vnNg-flgntrlmolt,aut.te't;119HIMSdS{40F1r, mut INS AE0e0II011 I6TCu UAiI"::CICif009ki1Tfr;a rniht?u{aFn3e:uspilafpits Ietlis'pss 6aIP t`rsiy(DC)rxd5!1a4mLink Oi,PLI=:utto TetelSetue nt.Cr`esaa+!.ist stateE corks 1rD,aaly
dlReYsmaefu tfates still ee ,tdillat10011.5i. Asnitas Ces nFyilpr{ie Srtal'FEAT'8!tl};Msp4p¢rFv'AltrlataSp0atylE44'0.dYd'.dpi!pk red Yti 6JalatW5i1'ik}g!Me!(331j1IIR!ssa;lt Fpil dgimdp!ptOC ith, aPIFi IPNI, ra: feSlr4 p:Fi 6p, kafur3ed"dpr. ft!fC:IAJ
aktf'151 Imsk!@JB3ii--j tf&tow.'fl one's ygtnw,il At wat firm ilf,dfRC ON but atldur;gdemliP6l. Tk lLppeldtyhppl a{(itiltuAfle tpss, mlcdbj aartr 1, sluyt,ux"ehpsdknel aVell l!a!alpssuilyd Anthony T. Tombo 111, P.E.
6,W1.1ho aOffaft"r. Ans#afalAa!r'!r'!!.ANj"seWUfr f:.m 0b"1 y(FS}pFNSA1f ILIt!8Gtl(�.IFI(9;" tdkt iFtpi SriA ptrF�YIM}ffy,rtM:4l rald6(f.I?LId?M!fS]tR3j3fI1{II;!S fadfAk11I3tT.E,f.IriCa; 1pfS CfSl�Fyialtl Dl;nssLl:edoGtns " 80083
ak as sd feyslpl, f of 4451 St. Lucie Blvd.
era ri:iagh {etin Ls!tlstd: Ikrass CtsIph¢uai,1lN fit luldty ptsipa,e!?+ass Snfe7halxwss prketiar. lEl udihlil!fL•;nssrt es deAxtf it?FLI.
(epytight020HA-IRoolitasses-ArtbonyLkinholll,P.f, teptedarfioaofibisdowninLinanyfmm,isptohibiledwithouttheaatlseopetmissionfrontA-1Realhosses-AnthonyLTontolll,P.E. Fort Pierce, FL 34946
Job
Truss
Truss Type
Oty
Ply
A0118573
WRMSCMB3L15X10
B02
COMMON
3
1
�RENARMORNINGSIDE
Job Reference (optional)
A-1 KooT inlsses, ror( rierce, rL d4`J40, UU5IyII%_Vd I❑uss.wrn nuu. o.cev a may ems'.. e� a e.,e. �.�,... ,.Loy ,.. �..... ......................... ........,. _— .—•--• ._ _—.— .
ID:Id_00XyyT61Bi TXo1jwHHzefvK-Np2F121xY?FXr5ELOLCkSjIDm7G?3VbDksFDZ
-1-4-0 6-2-0 12-4-0 , 13-8-0 ,
4x4 =
3
lO
3x4 = 1.0x4 11 3x4 =
12-4-0
LOADING(psf)l
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL
20.01
Plate Grip DOL 1.25
TIC 0.41
Vert(LL)
0.05
6-12.
>999
360
MT20 244/190
TCDL
7.01
Lumber DOL 1.25
BC 0.40
Vert(CT)
-0.06
6-9
>999
240
BCLL
0.0' `
Rep Stress Incr YES
WB 0.11
Horz(CT)
0.01
4
n/a
n/a
BCDL
10.0;
Code FBC2017frP12014
Matrix-MSH
Weight: 48 lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins.
BOT CHORD 1
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recomoends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
532/0-7-10 (min. 0-1-8)
4 =
532/0-7-10 (min.0-1-8)
Max Horz
2 =
-62(LC 10)
Max Uplift
1
2 =
-144(LC 12)
4 =
-144(LC 13)
Max Grav
2 =
532(LC 1)
4 =
532(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.'
TOP CHORD
2-3=-632/420,13-4=-632/420
BOT CHORD
2-6=-201/508,14-6=-201/508
WEBS
3-6=-15/282
NOTES-
1) Unbalanced roof live loads have been considered for
this design. 1
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. II; Exp B,2 Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live loan nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except Qt=1b) 2=144, 4=144.
6) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPl 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
6'e!uq•rL•ssetlusettls!eeiere3e'AdL7GF f15SBj SE(lELa6LF:l(L(TlslSd[@r:4IIDlS(9STDiA(Ctrt9;E(LMDRIFYFMP Ixr.Te!A19ssileimadnsezderd cstssnesis L€ss Bes�DiniyfRi;eike lClegT. Tesb D,(t tdaese Sk!slraene. Odess Hlvris!ASlei eetle7OD,eir
Affilueeemrp:e!es sksRteisedter Ox DDuk,ft essTens DuipF.l!uu0Ie,S!,00r,hdee'rWem wgTOO Rpm 0"m:t It 0, ponstnde sFe:iet espudliieta roe des:padOf s�*Tress derddisIke M2.11,edaMI. Th dx4ps usmpes. led..;w6nx!, seadU7 Anthony T. Tombo lII, P.E.
Ow Tresshne110161 is Ike uspmlila.dt!sO—,eef OwuiseA m!itdaye:du Ikefolhp Desp!,n lit mm0 d du lK,iaR. Islas terd1,Tgnde.1MI. TLegTmil dole IDDnd Leer bld us deer Tnss,Wdee L-4h;sh;ile, issullstiu nd 1.09 s5dla lhi re!Im0,11yd :80083
I Its, Nlftj N'4q!.1&Mae!. All ef:es WWI, lye(raennad}nldnss of th9.1lieprmi,am Sdenix4:menn(t61?plluW(1 Tfl and SKA uereLmmlle pmot a:dmu. IN eisTress 00per,Less Des!ps bti ffeslrress6'misCne!,ea'ess 4451 St. Lurie Blvd.
e!lsnisf denedipoied:pi eyed epLhvrifig(polimes inches TaeTnss".ts.r!Eyiieefli'lol,xra-dapGesipa,uln!i Sps!!m apn!ttrmrSedSap(n eq.�dtroseteesdefadeeirii. Fort Pierce, FL 34946
Coppighl02O16A-IRodliusses-Aot6onyl.IemhaIII, P.E. Reprodulrionofthisdocument, inany arm, isprohibhedkrithatathe rrivenpermissionfrom A-IRardImsses-AnthonyLIamb M,P.E.
WRMSCMB3L15X10IB03 (COMMON I' -dry It"y
1 IRENARMORNINGSIDE
A0118574
uesignLaiuuss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Aug
ID:Id_OOXyyT6lBi_TXoljwHHzefvK-s0cezO2ZJJNOSFpYy3jzwq
1� 01 4-0 6_2_0 _
6-2-0 11- 5-9-1414
4x4 = -.
3
4
Io
1.5x4 II
3x4 =
3x4 =
2018 Pagel
LOADING (psf)
SPACING-
2-M
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.41
Vert(LL)
-0.05
5-11
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.37
Vert(CT)
-0.07
5-11
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.10
Horz(CT)
0.01
4
n/a
n/a
BCDL 10.0
Code FBC2017frPI2014
Matrix-MSH
Weight: 45 lb
FIT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
439/0-3-8 (min.0-1-8)
2 =
524/0-7-10 (min.0-1-8)
Max Horz
2 =
73(LC 12)
Max Uplift
4 =
-103(LC 13)
2 =
-143(LC 12)
Max Grav
4 =
439(LC 1)
2 =
524(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOP CHORD
2-3=-607/424, 3-4=-610/425
BOT CHORD
2-5=-261/485, 4-5=-261/485
WEBS
3-5=-16/269
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf,, h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except at --lb) 4=103, 2=143.
6) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
6Erdq flnse6irniHA mlexfie•Ad IDCfn7Ss3r'iu(P16(A:((TUISS[inh"AIIOrJSt7nOxj artrJ'ja(IIDORtf"u'�NEnr Md 1.4hudepenna EatrH a?tat?asT!Ess]es!yn 7rariEgl((;!;Erl lot lEnu(tToaaa r;IL6rereaESlnl Warn?. udEE: Etlt•.rsE ilddEsn!mD,sm!p
AOTEA(tleFmri!¢his4d(4 Died fitr&IDD6 it lOflt.,{itlrniDtsiii(1(IFRH�1.!.(St!1!Ilj(lde4?r;,IS! 5!6�EB ee(TDD(EIRSMSEE[((1N3[e Ei lOe (l0(riSIMb Er�AH.fllgr!gns!nirtl metn:0!Edtless�ein?sk('net EeIke Mali,, Baler MI. The �Eda7on8nxs,smiliNl Anthony. Tombt) III P. .
tJ Estdlis Tosslor 1.7 Mimi is lemil"0100hNear. at0.uisEE*:,d,;d or lAe Ateliiot Desl(tt!,mfsmint It its K6?it' Did 6e htdAw:[rt role .1MI. TSeorpm!d tfe IN Ellen hill Eso d9E TitmidEan 1-414 smirye, fishtld(n uitErut; slielifie h•2 nspai.hd Y ' E
' IN I,hiDes'gmt .W.?.fOgEe3 sd gi4R,•IDD iN In p�¢es®A piidh!sd6?tnlGq tO¢KaMSdery la!DmEen{tfA}pNis(ds)In WSW rterdyextlfe ItrtreI Fi.:L IN 65.1lempmidru.1&%?fd6?T!e,MieM,Imshi!DD(fjt'Cerpt I.,, tiYidlh!ef,Rk,s z$0083
EIEMte ldiErA 1(a(En:me�eM oitohnlfisg l(dl ier.,ES lmdiet. iheinss DEs:mEipiter is XGi 4`�ADiiAag C�Itser,rtT�st S?r?a EaprserdaA liil4iy, All [q:a.Mhrws uessldaNhiPll. 4451 St.,Luele Blvd.
• Fort Pierce, FL 34946
(epiTigM©t01dA-1toalLass!s-Ant6onyT.Tom6o116P.E. ReproEaaioDolthisdumment,inany form, isprohihAedwithevltheivri0eoparinissianhemA-IRoof Trusses -dnthOnyT.iam6oIII, P.E.
Job
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE
A0118575
WRMSCMM.L15X10
B04
MONOPITCH
1
1
'
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Aug 29 15:28:49 2018 Page 1
ID:ld_OOXyyT61Bi TXoljwHHzefvK-sOcezO2ZJJNOSFpYy3jz wgNiXdeosVNzW?n5myiyuC
-1-4-0 6-1-7 11-11-14
1 4 0 6-1-7 5-10-7
3x4 =
6-1-7
1.6x4 II
1.5x4 11
4
4x4 =
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/deft
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.46
Vert(LL) 0.05
6-9
>999
360
TCDL 7.6
Lumber DOL
1.25
BC 0.37
Vert(CT) -0.06
6-9
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.45
Horz(CT) -0.01
5
n/a
n/a
BCDL 10.6
Code FBC20171TP12014
Matrix-MSH
LUMBER -
TOP CHORD �2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 12x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, except end verticals.
BOT CHORD '
Rigid ceiling directly applied or 8-1-12 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS., (lb/size)
2 =
518/0-7-10 (min.0-1-8)
5 =
434/0-3-8 (min. 0-1-8)
Max Horz
2 =
264(LC 12)
Max Uplift
2 =
-107(LC 12)
5 =
-191(LC 12)
Max Grav
2 =
518(LC 1)
5 = j
434(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD,
2-3=-613/1951
BOT CHORD'
2-6=-486/500, 5-6=-486/500
WEBS
3-6=0/273, 3-5=-558/542
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces $ MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except at —lb) 2=107, 5=191.
5) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
PLATES GRIP
MT20 244/190
Weight: 62 lb FT = 10%
N'edry � rleesetlmyTlrrz!iexih'd-I 17C; Ill';s8i irllEl'E 6[e;td! IEWS d (0lPm[9h f7S7aM('i(R9'IAllegd:ro,YElil' fn¢_ Tertr(dttip rymden W RMei!z p1liaTins gesezarairyiRG; t� dt ddluTT, izsha ei, r.E rdYexe4nl te�:e ne. Ildess tthreise ddd utle IDP,u'(
Mihimeecbrre:sit-witts He rgahb,,41. Is erns Usti. fi(1v[!(te,sµdr,UV-1,mas!dnurIDo!larntsLLtert,firm dlSerfd:eSlOed!y'tF!'iyL•ry!ifllilRlfor NlFsOne saoelims hpolwit Too W1: werTtrl. Tu t!s>7 mtmpn!s. Ininm611xs,s!aemry Anthony T. Tombo Ill, P.E.
er as,Antis lresss!tgrnllith is tee resdnsitiloy!d'NNur-RtOeuisetoiske;futh ldliup Uni¢v,n:amhd d la lR'thlR:Wth I'd WC9.1,.1P&1. Th yFmu d1h le0eiln,tidlue dhe Tnx-ud!tirskq% wit" ieswl iea W lnrirsshalls. N selp iltrIf 280083
' ueln:e2goes:gatrlraVtdo!, di:reassnaaliettelaDnllaep�iresmdpedgnasdt{arrildig(c �taedSderyM`rn[nee(t(Sfjr!NISEe6hri?Indsl(Ane«term!i!e!Isn!nlaAne!.1P'slNirtsletesgHeih9mes!e9bP>sdiaces:o!liner,ress7esylFepu!rmiTnssxaxetn:ecx'ess 4451 St. Lucie Blvd.
.eteMst(dad If Gd:ed yreH rite is wdaq {T dIrM:Fs irnt?lei teelnss Ca,Ip Fe;u!erIs NCT:�6aSag.F;igaer,nT�us Sps+!a�t!erdwTScilliy. Ulrq;:a!§h;os nemddae11a1PFl. Fort Pierce, FL 34946
(oPpighlm2016A-lRodItusses-AnihonyT.Tomho111,P.E. Reproduction of this document, inanyform,isprohibited withaulthe urittenpermissionboon A4Reoffresses-AnthonyLTomb III, P.E.
Job
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE ;
WRMSCMB3L15X10
B04GE
GABLE
1
1
A0118576
e_1 R...,fTmccoa r.... Rr,..,.,.
n oen.c
-
Job Reference (optional)
cs.g;—a Riss.wur Rue r. o.L ru ti may to cu-ra rnni: a.ziu s
ID:Id OOXvvT61Bi TXo1
puriins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 8-1-12 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (Ib/size)
5 =
434/0-3-8 (min.0-1-8)
2 =
518/0-7-10 (min.0-1-8)
Max Horz
2 =
264(LC 12)
Max Uplift
5 =
-191(LC 12)
2 =
-107(LC 12)
Max Grav
5 =
434(LC 1)
2 =
518(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-613/195
BOT CHORD
2-6=-486/500, 5-6=-486/500
WEBS
3-6=0/273, 3-5=-558/542
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces 8r MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
5-
4) 1 nfs truss nas peen designed Tor a 1 u.0 PST bottom
chord live load nonconcurrent with any.other live
loads.
5) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except Qt=lb) 5=191, 2=107.
7) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
id 2uia Mf I ek Industries, Inc. Wed Aug 29 15:28:50 2018
1.5x4 II
4
&rein •nus, 6-11elrn,irk th'e_I i90F RZESrSIanffliju. TE1i6301,DUS TmoxrulW) urrefilE,TsaurrIan. Thar f sip Ear Beim ni fWa!s n ILi Nss amp1.11r(EEV, nI If111 wyl. Tme) CI, E.L ldi ,ses s1af tf%rf he. uesss,ti-isi and tath!TaP,.!y
MJTekoaem,i'ehl sldite nel br BZTaO tak,dil. ssaTrnl DesllrhCnaji.e, STedrlly E,praa„:ie usi sr rrylDD rerrelnts re uo-ps:etltle irofeulud ea!eenrg resrnslllllt1;Meft poll be siosTnesfys<n!I re6el00n¢, derTPN.The!s!rnesvnrmu,Irel3aurHnas,tmrliltry Anthony T.�Tonsbo III P.E.
dr-Me rm'fhoy aiWn is be ruressileiiry rfrle0—.be nth kiliiu Duitnr,nr: mm4d lie lRE,d! 6E W Ike Ind ta:d gaft.1MI. Th egani site, IDS sal n:fidi ne 660rass, iaftm Wki. m-ere, mWidanikneg sViEA th rarasi':ryd ' beam:aoeslserMfearao!.rGtAselalk6el00r�tarrWasW}nisi,sdthtnllq(eapenSrterytdwann{t(fir,NrsWSrTIrdTTnnerd-1f.gnnlpin«80083
elFSlltSgs3ergensntsnid_nta!Tnlaagm,tns�eeseyRamarnSs� tau.xr.
e6rMnIdirti Tpohdrcd rpetd rNeirwnaq IT dl rrr, sisrsLei❑,Toss Nslp Eeilen Is Wis.Isib; Ong1a,nTrus Trsda Equer 94451St.Lucie Blvd.
008or hilt] Ill,�fdaN&:as ueas ddaNialTld.
(opyrigbi02016A-IReaf hisses-AnlbonyLbselioIII, P.E. Reprodudianofhis doamenf,inany form, isprobibiledwitheutthewrineopermissionfrom A -I RoofTiosses-AntbonyLTombo111,P.E. Fort Pierce, FL 34946
Job
Truss
Truss Type
City
Ply
RENAR MORNINGSIDE
A0118577
WRMSCMB3L15X10
C01G
GABLE
1
1
Job Reference (optional)
A-1 Roof
trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 is May 18 2018 Print: 8.210 is May 18 2018 MiTek Industries, Inc. Wed Aug 29 15:28:51 2018 Page 1
i ID:ld_OOXyyT61Bi TXoijwHHzetvK-0OkON33grwe6iYzw4UmR4LwLKAwGgPgQgUiAeyiyuA
1-0-0 9-8-0 19.4-0 20-8-0
1 4-0 9-8-0 9-8-0 1 4-0
� 4x4 =
4X4 = 't•x`i —
4x6 =
2-0-14 1
1-
1,9,51 9-8-0 1 17-3-2
-5.14 0-317 7-7-2 7-7-2 2-0-14
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
TCLL
20.0
Plate Grip DOL
1.25
TC 0.47
Vert(LL)
-0.13 12-15
>999
360
TCDL
7.0
Lumber DOL
1.25
BC 0.90
Vert(CT)
-0.23 12-15
>954
240
BCLL
0.0 '
Rep Stress Incr
NO
WB 0.87
Horz(CT)
0.02 12
n/a
n/a
BCDL
10.0
Code FBC2017[TP12014
Matrix-SH
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD I2x4 SP No.2
WEBS 2x4 SP No.3
OTHERS !2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-2-2 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or-1 0-0-0 oc bracing.
JOINTS
1 Brace at Jt(s): 16, 17, 18, 20, 21
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS.' (lb/size)
2 =
777/0-8-0 (min. 0-1-8)
12 =
777/0-8-0 (min. 0-1-8)
Max Horz
2 =
-90(LC 6)
Max Uplift
2 =
-160(LC 8)
12 =
-160(LC 9)
Max Grav
2 =
777(LC 1)
12 =
777(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD;
2-3=-1176/244, 3-4=-796/140,
4-5=-754/140; 5-6=-731/159,
6-7=-722/185, 7-8=-722/187,
8-9=-731/161;9-10=-754/141,
10-11=-796/141,11-12=-1176/241
BOT CHORD
2-23=-184/1053, 23-24=-184/1053,
24-25=-184/1653, 25-26=-184/1053,
15-26=-184/1053,14-15=-184/1053,
14-27=-18411653, 27-28=-184/1053,
28-29=-184/1053, 29-30=-184/1053,
12-30=-184/1U53
WEBS
7-16=-42/430, 3-19=-410/139,
I
i
WEBS
7-16=-42/430,3-19=-410/139,
18-19=-411/139, 17-18=-411/139,
16-17=-405/134, 16-20=-403/132,
20-21=-411/139, 21-22=-411/139,
11-22=-409/137, 15-16=0/395
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf-, BCDL=5.Opsf, h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Truss designed for wind loads in the plane of the
truss only. For studs exposed to wind (normal to the
face), see Standard Industry Gable End Details as
applicable, or consult qualified, building designer as
per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise
indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
7) ' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
8) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except (jt=lb) 2=160, 12=160.
9) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s)160
lb down and 73 lb up at 2-0-0, and 160 lb down and
73 lb up at 17-3-4 on top chord, and 77 lb down and
35 lb up at 2-0-0, 17 lb down and 1 lb up at 4-0-12,
17 lb down and 1 lb up at 6-0-12, 17 lb down and 1 lb
up at 8-0-12, 17 lb down and 1 lb up at 9-8-0, 17 lb
down and 1 lb up at 11-3-4, 17 lb down and 1 lb up at
13-3-4, and 17 lb down and 1 lb up at 15-3-4, and 77
lb down and 35 lb up at 17-3-4 on bottom chord. The
design/selection of such connection device(s) is the
responsibility of others.
PLATES GRIP
MT20 244/190
Weight: 108 Ib FT = 10%
10) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
11) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-7=-54, 7-13=-54, 2-12=-20
Concentrated Loads (lb)
Vert: 15=1(B) 23=3(B) 24=1(B) 25=1(B) 26=1(B)
27=1(B) 28=1(B) 29=1(B) 30=3(B)
i
6e!dq tleecedsngXlrrtfie�tee's IiDOFfi'v'iSrS�iIU[r'�6<F31.IEIs158(DN:fIIDSs (95TORj rA7'J'IS;Cg6'�cSMiMi Ixa iero hip wllii Lms D?Le!5-1(R9j RL th, hlttrT. T.I.Of,t.Lid—i Simi li! t f. Uslus di -is, odd m li, TDO,.!r
Glltkfetxmlt�t}i i1�::?lttlrlilk TID If SembC is trims Dmlrt lip[tE! e.Sre:ell kdag',O!oulm lay TDD,p.msItR¢pwdtle tit lest'!th S4frb!f{?tmd teas IN ulpjuI'M. The imp eswrwl. Iminwinfti. smd,ley _ Anthony T. Tombo III, P.E.
Pe1'tildfltlrtfs`<r teT rdiiitr if lh fefritf111llh dheO>•rt0k O`effieA,.,imtyed it ass WAS Olfl¢tr,Wik ndid of Vis 1111,52 it, mi th lelA L:iie3Tft-1MI. Thapirne dth TOD mite Deli ist doe Insi. tal'a'S i.". Mill', i'deffdim nd b t, sf]ll!?i^-ermJ39VIhd z80083
' Ihr.REOftSMilFir(9e,11It!.RCef!I3fe{PfixY[2TDPIUI3trt�IleSW'I�vi!In!fflitlrF1IQ11rrCIfrA2dSdtIrI1PT[ilet{r(SI;r1HiSW�r%ItHSNitlettl!1'Y!t±eElre[tYdyidsvmTrtlfElrQi�?RrE'1iSxilefMtClS?Sd�!T:1ffDt3131t1,I!HS)ef FL,I1SHdiTlitf�titll/^P!!I,m}tS 4451St.008Blvd.
itahst lffitdlTort9�m sped tsm et wdDq lTdl rin:ts isrzefei Ti,Tnit<;?arsr aer {f ACICe rA )OfsiD,er,rtT tts sn'!a opit<rdmr hD4si. lJlfq_..ad?t.�ai near adsdisTn 1. Fort1St.Pierce, Lucie 34946
(opyri;ht02016A-IioafTiosses-AnihonyT.TumboIII,O.f. Reprododionofthisdomment,inanyform,ispiobibiledwithculthewrittenpermissionhomA-IReoffmsses-AnthonyLTomb 111,1`1
15X10j CO2 I COMMON
tJPIY 1 IRENAR
A0118578
t I I I IJob Reference (optional)
rce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Aug 29
ID:ld_OOXyyT61Bi TXoljwHHzefvK-oOkON33grwe6iYzw4UmR4Lwk
-1-4-0 5-1-4 9 8-0 14-2-12 19-4-0 20-8-0
1-0 0 5-1-4 4-6-12 4-6-12 5-14 1-4-0
4x4 =
4
4x4 = 5x8 = 4x4 =
Dead Load Defl. = 1/16 In
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in
(loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.44
Vert(LL)
-0.14
8-14
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.85
Vert(CT)
-0.22
8-14
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.21
Horz(CT)
0.02
6
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-MSH
Weight: 88 lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-10 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 7-8-8 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
2 =
791/0-7-10 (min. 0-1-8)
6 =
791/0-7-10 (min.0-1-8)
Max Horz
2 =
-90(LC 10)
Max Uplift
2 =
-205(LC 12)
6 =
-205(LC 13)
Max Grav
2 =
791(LC 1)
6 =
791(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-1189/788, 3-4=-898/581,
4-5=-898/581, 5-6=-1189/788
BOT CHORD
2-8=-562/1042, 6-8=-574/1042
WEBS
4-8=-264/553, 5-8=-347/387,
3-8=-347/387
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces 8t MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads. .
4) . This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except Qt=1b) 2=205, 6=205.
6) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI1TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
Bndq flecetlatytlrrtlieeth'Ad IDGF a0SS2rSEttEI'�6E19ASfET115dC0F010[iS (DS10Mj EL08 jAErrC6',f06EX1'IHr V01hupramdtrs Aon! nusards l?tv Des Dirviy(I@O; rri aM ldlrePT, it iaCl,LE tdHest%,eff rtest. Ddsag* nsrdek to&IDD,ta'p
H1lekottttarg:tts sidEa for IN DDI,k n1l. Asrrrrst Desip flSl[eH(Id.SfHI1D(ElSlrfe;.lia utin mTlDD apresedsntat{Sa;td tie pdatil4[dlriiH'IaF rlsrnnlllnr S:llt ltfxndlkefi[ ETnss6pinelmntTDDedr,O.tiff'[?41.R4S?S'rei5aajeiei*.It!12j<itNnell,fdleklll:r ' Ikeldk<x r Oet ��ad[caeean. T: ,, rAnthony T. Tombo Ilisin"Insn dxO.".610-sns rifiludeedke WLIJ DuiTer,ath adeddaIktals,WAslnd 10rr ae oMI. il800831' P.E.
A,"Nlstelorair.TDDlist ostasad Idrin'ti1a16t 4c, amsSd zroton;W,phi&sJI7MStq:�ectu!pAa?1Ftadb'�dDLttlupH,Ls7eapDHattase�rnss 4451 SzL Lucie Blvd.
tltnriuddirt! Ipote9red epesd apa it wrilitr 7 dl rm:ts indrei raeTass Ceslp Eyitar6 r0f Cx rainy DnipH, alms SSsha Eyiasr dar`a06rg. All tq'�aKtrm taea Idaedkrllfl.
(oprrigM07R1dA-1Roafliusses-AnthonyLTomboIll,P1.ReprodutlianohNS11DOmenl,inanyform,isitohibitedwithoutthewrittenpermissionfromA-1Roo}Trusses-AnthonyLTomboIll,H. Fort Pierce, FL 34946
Job
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE
AMSCMB3L15X10
CO3
COMMON
1
1
A0118579
Job Reference (optional)
A-i KooT a russes, ron rlerce, M .wuvo, oesignLa ltruss.com
5-1-4
Rule. 0.41 u , Ividy 10 Lu 10 rl 111e. 0.41 u a 1—y 10 Gu 10 M.I en 11I0uael lea, ..— vveu r,uy — I.'e
ID:ld_OOXyyT61Bi TXoljwHHzefvK-GbimbP4ScEmzJiY7dBHgcZSt2kXJ?G7pfUD
9-8-0 14-2-12 18-11-14
4-6-12 4-6-12 4-9-2
4x4 =
4
44 = 5x8 = 4x4 =
Dead Load Deft. =1116 in
9-8-0 18-11-14
9-8-0 9-3-14
Plate Offsets (X,Y)—[6:0-0-0,0-0-14),[7:0-4-0,0-3-0)
LOADING(psf)
SPACING- 2-0-0
CS].
DEFL. in (loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.45
Vert(LL) -0.14 7-13 >999 360
MT20 244/190
TCDL 7.6
Lumber DOL 1.25
BC 0.82
Vert(CT) -0.22 7-13 >999 240
BCLL O.d
Rep Stress Incr YES
WB 0.20
Horz(CT) 0.02 6 n/a n/a
BCDL 10.0.
Code FBC2017frP12014
Matrix-MSH
Weight: 84 lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-1-0 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 7-4-14 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation ouide.
I
REACTIONS. (lb/size)
6 = 700/0-3-8 (min.0-1-8)
2 = 781/0-7-10 (min. 0-1-8)
Max Horz
2 = 99(LC 12)
Max Uplift
6 =-165(LC 13)
2 =-204(LC 12)
Max Grav
6 = 700(LC 1)
2 = 781(LC 1)
FORCES. (lbj
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-1164/783, 3-4=-873/576,
4-5=-870/575, 5-6=-1145/768
BOT CHORD
2-7=-619/1021, 6-7=-600/981
WEBS
4-7=-258/527, 5-7=-311 /365,
3-7=-348/3871
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
r
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Extedor(2) zone; cantilever left and right
exposed ; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 100 lb uplift at
joint(s) except (jt=1b) 6=165, 2=204.
6) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
1
ecdq.n!„!n,.11yfl.rl+trrrF>e�41100f 118SS3r51Un V1311 lflN58(OEtli101i(ISiDtlt tt7];i(ClO17Fc NEMi fu¢. re d!upyoezJ+n eaOF�lesl:snFli,l•!ss 8e,ip 9mig(1f4;Frl tEe lrtluAl.l!a6, 0I,IL feluexe &!!t Se re ese. OdessGhniu tl+sd IttkfU0,w't
wTFyo. mFyxe,:s�;: rtelnr*11DIsk-ALA,0n,.4e jTDMF,,seesFeuu;aaOeeeyFd nde{ emarzynsilAnfSrwelems;Rssan!Tnsi!y1!!F!deNDadt,Mulf4l.l&e :lannu`tilq.hfi}mhnn saFlry Anthony T.TomboIll, P.E.
r/esedriz lrssskF,gl,iliiq is tk sespl!RiIn7dPa 0.,!etle0anisedai,el eleAClk lalli,g 0esiynr,at!,e uF1F,I1114FIK,�sll.ulfiebdUffrgal,,zKI. Thrpl,uldth!DOOIi,,Wfa, llll!TflS,.J:IeWC}R"d1y.fR!pyF,f„hIIpI1181t1 M13y 3S>liv3, 9re!yFJSA:':hd u80083
' IIrC.tllaa9!s:rx1FNQ4-Fnm.ktu,SseiwtsCelODWheyoditesvol pildnelrtthWtiqtwFc¢mSAFtyfzFFnuin{t(S¢yel6s6n!5yTMoslSlUmrdeamil!apr 1pl&LIfrSE!See,4!:ryras!fenFSWlaf!,ft0ms0niptt,LessM!papxnulllrt!sn'ess 4451 St. Lucie Blvd.
r3,1huldi,rllro(eil:N gFeFl epee Maq lids pd:nl!,ehei Tlelnss trdfghen L-e0llx ldilai CFsi}ier,rtiu!sSp¢:a"ryu!erro79r0lisy. Allrpw:sMk:os nemdduel (�ItAI. Fort Pierce, FL 34946
(opyright©2016A-IRoof tmsses-Anthony T.Tomho111,PJ. Reproduction of1his duumenil, in anyform, is pushibihed without the written pernnissin from A-1 Roofhnses - AntfionyT. Tomb Ill, P.E.
NGSIDE
WRMSCMB3L15X10JC04GE IGABLE
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek h
ID:ld OOXyyT61Bi TXoljwHHzefvK-Gbl
fi 4 (1 6 &5 12-10-3 19 0 0 25-11-8
6-8-5 6-1-13 6-1-13 6-11-8
WCtlA Zx4 JN NO.3
OTHERS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-2-3 oc
purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. All bearings 0-3-8 except (jt=length)
2=0-7-10, 10=0-2-12.
(lb) - Max Horz
2= 294(LC 12)
Max Uplift
All uplift 100 lb or less at joint(s)
except 2=-168(LC 12), 8=-138(LC 8),
9=402(LC 12)
Max Grav
All reactions 250 lb or less at joint(s)
10, 8 except 2=71 O(LC 1), 9=1105(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-917/499, 3-4=-614/311,
4-5=-478/323, 5-6=-166/367,
6-7=-154/355
BOT CHORD
2-11=-709/789, 6-9=-586/481
WEBS
3-11 =-391/462, 5-11=01355,
9-11=-421/485, 5-9=-702/626,
7-9=-390/481
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
A0118580
t_
Inc. Wed Aug 29 15:28:52 2018 PaATe
6.00 F12 7x6 Q
Dead Load Defl. =1/8 in
k—veruNcp
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left and right exposed;porch
right exposed;C-C for members and forces iMWFRS
for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the
truss only. For studs exposed to wind (normal to the
face), see Standard Industry Gable End Details as
applicable, or consult qualified building designer as
per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise
indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
7) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
8) Provide mechanical connection (by others) of truss
to bearing plate at joint(s)10.
9) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 168 lb uplift at
joint 2, 138 lb uplift at joint 8 and 402 lb uplift at joint 9.
10) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
&r!dar neese nursyElrra,irwlk•Aa neE OUSSrSt iEtlEl'A Ptrei(TEINS8(OFTYTNCIS[US10Nj i(rtEljn(I;ICiLv'aNEM'hra. TerNp dedrrroroders ndred eN?S xIliS 11E5f DH rs DroviaplQCe'rEl iEt AdlxTT. TFeIs Al,r.LIdtRAIAH1(;2!!m!. Udeff iILKI1Ie ddd IA tit 1O11,41
N1Trimmefirr:eis sldl(a rsedfrrMa TDD Ie Se nIil. AseLms Oesira Frpreprjl.e, SpesdNy 6d¢terrtn?uelxnrlDD rerrmMsxaxpaudlae rrdmslndmlrF?:leg seguslAunrie tee las stl Nes�epeixss a?jinee retltIDPxiy, calerlrFl.litimir>msenplrra lrel:rdtx'unres, smdimr Anthony.�Tombo 111 P.E.
Hotd+lis lrusI"!say rnllirl is 11, resrwslliliir it be 0vir. Re O.rliS easmul I;d Or lies E.; 0esilrfr,.N(uni dN Xti?'i; at tit Ind bltjMt.1Mi. Tit gpait!dlie IOD oA nl Ndi is d6i Tress. W,6,l Ir ft. sale, irfillelin ul k. s4?ett fAmruc�S?:hd Y r
' « 80083
IhtiAipDes:rx rrl(c4�rp!. Lll xisxlcdklAelWMlm r!mnes®s;+ildisdll. tnlfig(anpam Sdery lieamx �tfSfjrrNnW Sp TEI nASI(A naMvexeddse px!dplarr lfFilr5etSirrr.Ttu6•.TSs adbnas d'iel!rss[4ll�rc,T?ess 0ap FigrrteadTnss4mirnna; xis;
rfrnise ldieaflTa69rN rgeed rpvirxrifiq lydl rafm im:?sel lieTxss fac�EayiSeer 1190TCz ea;daj0esireer, erTxss Sps:ea Earu=<rdarbnlLar. All eepwa?bhrm seem def dial)EI. 4451 St. Lucie Blvd.
Ca rli hf0Si2016A-]ioofTmsses-Anihose I. Tomb III, Re rodunionoffhisdommenl,inan hr is iobihhedwitheulthewutleo ermissionhomA-IRooffmsses-Anthon T.ToethoIll,P.I. Fort Pierce, FL 34946
PY 9 Y P Y w P P Y
4
Job
Truss
Truss Type
QtY
Ply
RENAR MORNING
A0118581
WRMSCMB3L15X10
C05
ROOF SPECIAL
1
1
Job Reference (optional)'
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
5-3-6
Run: 8.210 s May 18 2018 Print: 8.21 U s May 18 20its MI I eK Industries, Inc. Wed Hug 2a 10:28:5320 to
I D:ld_OOXyyT61 Bi_TXoljwHHzefvK-kns8ol54NYugxs7JBuov9m?Oa8sukelyt8z
12-10-3 19-0-0 2511-8
7-&13 6.1-13 6- 1
6.00 12 5x6 =
5 6
5x10 = 3x6 11
44 = 19-4-0
I 9-8-13 i 18-9-12 18-i11r2 25-11-8 i
9-8-13 - 9-0.15 0-4-6 6-7-8
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.60
Vert(LL)
0.09 8-9
>935
360
TCDL 7.0
Lumber DOL
1.25
BC 0.86
Vert(CT)
-0.25 12-15
>907
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.53
Horz(CT)
0.01 11
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-MSH
LUMBER -
TOP CHORD 12x4 SP No.2
BOT CHORD 2x4 SP No.2 *Except*
iB3: 2x4 SP No.3
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-41 oc
puriins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 6-'0-0 oc bracing.
WEBS
1 Row at midpt 10-12
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
I
REACTIONS., All bearings 0-3-8 except Qt=length)
2=0-7-10, 110-2-12.
(lb) - Max Horz
2= 295(LC 12)
Max Uplift
All uplift 100 lb or less atjoint(s)
except 2=L175(LC 12), 11=-380(LC 12),
8=-150(L6 8), 9=-281(LC 9)
Max Grav
All reactions 250 lb or less atjoint(s)
except 2=741(LC 1), 11=701(LC 19),
8=261(LC 24), 9=679(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORDI
2-3=-1103/642, 34=745/367,
4-5=-87/309, 6-7=-149/282
BOT CHORD)
2-12=-878/975, 10-11=-628/416,
5-10=-447/386
WEBS
3-12=-446/538, 4-12=0/368,
10-12=-517/576, 4-10=-699/616,
7-1 0=-281/377
NOTES-
1) Unbalanced roof live loads have been considered
for this design.
2) Wind: ASCE 7-10; Vult=160mPh (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf-, h=13ft;
Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left and right exposed; porch
right exposed;C-C for members and forces 8 MWFRS
for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
4) is truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
5) Provide mechanical connection (by others) of truss
to bearing plate at joint(s)11.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 175 lb uplift at
joint 2, 380 lb uplift at joint 11, 150 lb uplift at joint 8
and 281 lb uplift at joint 9.
7) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/fPl 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
Dead Load Defl. = 1116 in
I
9
4
PLATES GRIP
MT20 244/190
Weight: 151 lb FT = 10%
'6uug rinse duagNra!lentne'dd IDOf 8,1S8j iEnErA 6EIE1it 1E1WS8[OI:d1104i[OSIOMj G19';E(rtOd.EOuLLE{i'6rs. TenddNppsaodnasdteedadudtSillas OnpDea.ig(1rV,ak lkdadurl.istk ChtEtdnze Reeit#e!e ne. Odnsai-in reNcri, T00,41
klekin"rt'r!essUlt�.aseltuskT00It knit As visas Onga flow.(L,s{e;idid Eagnv).in ualnnT100upestoin stapmalie pal:sslntl tn3Ee;1a6nsp-lailtTVhe lesindlG set Tins kPilsl aan40 att, MuITt. 1h tespmsmpun. I.nrnwtiron, suldiiy Anthony T. Tombo I11, P.E.
H ne deisfrnt4ran{dlei1 is ge resrxnlnitaA0e 0•aeefh 0-is,fti'd qa.a th luldiaa Duper, m tk nahn d Is, 19.6ait:.1she bid b1 ties .1 Trt. The qpW d lk IDO eA !hill ue IT fit Tins,id,dq teii;;meep, intallalin aad tnrq dslit(,I tupetid:trd :80083
Ztna ka:Eet Des s!al Ccaaano:. All Is setwsutlelOOaadlk pWns.1 gnddnesdtee WWII aaraeesSfq b'..mn(trSl; pE0shd 4 In a ad SWnesdu tid"es pause Aare. lYl feirusdesurmbditm udO. s dl:luss Disipn. lint 0es!prap anal beer MavdaCe;es,a!ess 4451 St. Lucie Blvd.
.1imse Mad bratetC�grerd e?ra arr�igtt ell len:nWait The Gass usepEgienrlsd0i 4'r{nideg Onigser.nT.•ass Sp+saignserdmr5a0ffig. d0 sq-�atdb�as ttees laa>1n7141. Fort Pierce, FL 34946
(e light02016A-I Roof Trusses-Anthao TTomboIII,P.l. Re roducionoflbisdomment,inan farm, is robibitedwithculthew6neo permission Roof Trusses-Anthon TTomlinIII,Bt.
I Pt Y� P Y P P Y•
Job
Truss
Truss Type
city
Ply
RENAR MORNINGSIDE
WRMSCMB3L15X10
CA
Corner Jack
g
1
A01,18582
A_1 Rnnf Tnre— Cn.f Dse...o
CI OAdAC
Job Reference (optional)
cun: o.cru s May 18 2018 Print: 8.210 s May 18 2018 MiTek I(
ID:ld_OOXyyT61Bi TXoljwHHzefvK-kr
-1-4-0 0-11-11
Inc. Wed Aug 29'15:28:53 2018
LOADING (psi)
SPACING-
2-M
CSI.
DEFL.
in
(loc)
I/deft
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL)
0.00
7
>999
360
MT20 244hb0
TCDL 7.0
Lumber DOL
1.25
BC 0.03
Vert(CT)
0.00
7
>999
240
-BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
4
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 6 lb
o
FT = 10 /«
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 0-11-11 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
-3/Mechanical
2 =
166/0-7-10 (min. 0-1-8)
4 =
-16/Mechanical
Max Horz
2 =
42(LC 12)
Max Uplift
3 =
-3(LC 1)
2 =
-70(LC 12)
4 =
-16(LC 1)
Max Grav
3 =
12(LC 8)
2 =
166(LC 1)
4 =
20(LC 8)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed; porch left
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 3 lb uplift at
joint 3, 70 lb uplift at joint 2 and 16 lb uplift at joint 4.
6) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/fPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
ZEGedry-flnu hptgNrrtlleKlie'bl rDCr 119SSf3{'SFUEI't 6(I;U(ItiNS 6(DFU11O9S (BSTDMj S67]'iE(19ChtEuiNEN'brs.re;ilr dNnrurvden rid reed rNrsnt§.Trns BesgthniyERr"/tr3lt. atNwrl.lEaleu;r.(.tdne:t4ts!6s!rT ne. Ddessdkenist ddd ratlrTDP,eay
PiTtkain!«!i!nssitoh utifdheTDDhhe nhl. Asa Tins Desnattgnr.{I.e, Spaneaf 6pluer,.ht stNn«yTDO npresedna Mr.aa!trr prdnshtd eq'a«rue«spusiNiny fir helts�iaotht s�tpleTmssdep�adaeheM ulp,talaRR.The des:yeovnpfiaes. iadz ha9nns, stutiiiff Anthony T.'Tombo IIl P.E.
drsed!1nT;%s`«or(Wb1isfiewpnsitli!rdL`eO.ttn lle Ovuisaa`mritd ope9c Le ldlEry Dnip«!,nLe raanddha!K,hslt(What 11dip nis and RN. lie tfp«n!dtu 100 ail aaffie!,ndhe Tran, Mmq is 4 sS:rye, iuhadn"d Wag sWil h! respata!trd a80083 !
nxtsRafOts�a:adfw9rtr.aDtf3susrrfan<lDDull'vpr,Rises®lptia9nsntdsdil8q(aepsnsdSderyFtxngn;KSi)prllideihrl7leilSffAa«rdxeztd5sptu«I�da�Irrtet5ws3s:esptu!1dT«¢t'dfisstttl«ssDevpre,LessD«r,i.�!ermarassas,drn�er,xkss 4g51 St. Lucie Blvd.
rfcrvi.Wad irof.*m afed"is wi!iq IT all Janie iothd.Tk,Tnss Volp Isiouis NOT r1i Mal Onlptarrmb.'s S10%blur e.of beiq'Nsry:!.:tdhros aegis deAd is911. Fort Pierce, St. ,ci Blvd.
(oppTilibi02016A-IRoolhusses-AnlbanyT.Tombo111,P.E. Reproduoi000fthisdoaomenbinany fomisprohibbedwithoutthe wrinenpetmissionhomA-I Rao(Trusses- Anthony LTomboIll, P.1.
Job
Truss
Truss Type
Qty
Fly
A0118583
WRMSCMB3,L15X10
CJ3
Corner Jack
4
1
�RENARMORNINGSIDE
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@a1truss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 Mi rek Industries, Inc. Wed Aug 29 15:28:54 2018 Page 1
ID:ld_0OXyyT61Bi TXoljwHHzefvK-CzPX056i8rOhZOiVlcJ8h_YloYOnTD166oiXnzyiyui
4-4-0 2-11-11
1 4_0 2-11-11
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc)
I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL) 0.01
4-7
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.12
Vert(CT) 0.01
4-7
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT) -0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 12 lb FT = 10%
LUMBER- I
TOP CHORD .2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-11-11 oc
puriins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS.' (lb/size)
3 = 60/Mechanical
2 = 201/0-7-10 (min. 0-1-8)
4 = 30/Mechanical
Max Horz
2 = 82(LC 12)
Max Uplift
3 = -43(LC 12)
2 = -72(LC 8)
4 = -27(LC 9)
Max Grav
3 = 60(LC 1)
2 = 201(LC 1)
4 = 49(LC 3)
FORCES. (Ib)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown. I
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=13ft;
Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exted.or(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch left
exposed;C-C for members and forces 8 MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-610 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 43 lb uplift at
joint 3, 72 lb uplift at joint 2 and 27 lb uplift at joint 4.
6) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI(rPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
Cerdg, Nin AwegHs rnirthe%]13CF 117SS!S(-S( iq MEW TIN&(OPITICTS(UPOsArM9') UICdtf Ar, 1—ie,hp$sippatuOr. Wrerd'Aa.N, lrns hsp Dnriy jIrd?¢l IN War 1. ies!> ,11.ldia., tlattbAl ese. Ddess Nhnrst slild tstleIDD,ecry
11frattnmrl, sids4eenlhrthTDDhhtdd.AscTuns Mitt hpnr(!.e,Sp-11hd.!eTL.4aatTOO repetats.1-A-dIII pditsiudtafnrh1,al.011dorIt, hs-rdths-tpeTnssbgrudre lit TOO all, WKPIT. Thdesptnsrnpise.hrt"gmtnxt.smtiiuq Anthony T.TorntoIII, P.E.
clew dhis Trathteglnlrill is tie respwibuly dot Dan.th Owves rlh'hrd IT" rtk l liula Oestprr., M ftared If I", Ild IA: 3flit .1 MI.Thrime dlie TOD m(nrhe!dne ITS, Tms,adt6tslaAi4vgr,issh[dia ul tnfri s4ili4s P, repusi➢ur e1 80083
Rr ka:eep DesiS^e�sd &a;•tnr. A its sdanIsie TOD neliqumnesml Deilelhes etne hiltg(ecpimn SOW110mmn"MrIpe14ishi4 TA a( SKA mtnlr xerhr prr.!ptmr_iN Ahis 1, rapimiftIs atb5sdRe],ns Dirtier. Nis onh Peg..oasrrns AaANrer, Was 4451 St. Lucie Blvd.
skrhse ldirdipo6ll•etl eperd epehwrOigll ds psn.rs lci[hei TlrTnss Oala Eginer is7CT"„t laulap Drs.gsr,rT.•tssSSaex Eajrazrdmr ssiltg FO ty,,.�edkrm trimddaedfalPl1. Fort Piet. Luci, FL Blvd.
Coppighim2016A-1Roof Trusses - Anthony 1.Tomho111,P.I. Reprododionofthis dommenyinany form, isprohibited without the written permission homA-IReofTrusses - Anthony LTamhoIII, P.I.
WRMSCM13131-15X10I D01
Roof Trusses, Fort Pierce, FL
HIP GIRDER
Ply
8.210 s May 18 2018 Print: 8.210 s
Aug 29
A0118584
-1-4-0 5-0-0 10-0-0 15-0-0 16- -0
14-0 5-0-0 5-0-0 5-0-0 1! 0
Sx6
3x4 =
3x4 —
LOADING (psf)
SPACING-
2-0-6
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0 '
Rep Stress Incr
NO
BCDL
10.0
Code FBC2017/TP12014
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
2-0-0 oc purlins (3-8-11 max.)
(Switched from sheeted: Spacing > 2-0-0).
BOT CHORD
Rigid ceiling directly applied or 5-10-9 oc bracing
REACTIONS. (lb/size)
2 =
985/0-8-0 (min.0-1-8)
5 =
985/0-8-0 (min.0-1-8)
Max Horz
2 =
53(LC 7)
Max Uplift
2 =
-592(LC 5)
5 =
-592(LC 4)
Max Grav
2 =
985(LC 1)
5 =
985(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
TOP CHORD
2-3=-1667/1089,3-15=-1464/1016,
15-16=-1464/1016,4-16=-1464/1016,
4-5=-1668/1090
BOT CHORD
2-8=-947/1444, 8-17=-961/1463,
17-18=-961/1463, 7-18=-961/1463,
5-7=-914/1444
WEBS
3-8=-241 /420, 4-7=-240/420
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; porch left and right
exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
CSI.
DEFL.
in
(loc)
I/deft
L/d
TC 0.72
Vert(LL)
0.11
7-8
>999
360
BC 0.52
Vert(CT)
-0.10
7-8
>999
240
WB 0.16
Horz(CT)
0.03
5
n/a
n/a
Matrix -MS
5) ' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 592 lb uplift at
joint 2 and 592 lb uplift at joint 5.
7) Graphical purin representation does not depict the
size or the orientation of the purlin along the top and/or
bottom chord.
8) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s)108
lb down and 144 lb up at 5-0-0, 58 lb down and 86 lb
up at 7-0-0, and 58 lb down and 86 lb up at 8-0-0,
and 108 lb down and 144 lb up at 10-0-0 on top chord
, and 188 lb down and 202 lb up at 5-0-0, 47 lb down
and 68 lb up at 7-0-0, and 47 lb down and 68 lb up at
8-0-0, and 188 lb down and 202 lb up at 9-11-4 on
bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-55, 3-4=-55, 4-6=-55, 9-12=-20
Concentrated Loads (lb)
Vert: 3=-60(F) 4=-60(F) 8=-188(F) 7=-188(F)
15=-58(F) 16=-58(F) 17=-39(F) 18=-39(F)
PLATES GRIP
MT20 244/190
Weight: 65 lb T = 10%
ViTekt •rns'll' 5MItteitstlae'dd1DDf IIDSSt11.AS lEl1 �WEll!IEKlSd(OdrdilDdY(DSIDN{A1BjW(WWCGTED'aNENI'hfK, fe11r dtdP rurndm ra1rWtdnataislits:Des{tBrr+isglf[�;erclltAatlpPT.Tw:laB;rE.Iduene SleslEtaR nt. Ddesstllenize tl°ee tctle IOD,w'p
klhk°amaE:{es sW9lE: redfu t&T7D Ia 6e rdd Aseisns Desllt 6przu{i.e,S�utttr Ft[+ae„tstudnnrTDD regresetismcmpaadMe palssslxdegett;it@rzsrnnllllry6rlQe lesiladlCe s!ereluss fylnte tede lDD adr, aalul7Fl. ttx itsign me°pites, lectagenlinns, sulalilry Anthony y T. Tombo IIle P.E.
.dastdhn fnssl—q ldldirg is th felf"uIlliry ifN P.wr,tle 0—srv7r°e 'r;d K It, IaI&I Duilm-,°thurha l N IK, 6s Wiaeltet Tics[ g aft .1 Mi. TWe sp.r idlle IDD wl rltIsldtu d6driss.W,agW.rcd ln:ge.iuhDdirr.1 H°igstAlWt N,,lJ viddrd '
tM:(ag0es ^se erd[at,rfre. egsRs"IW%It, TAT eaethpula, W pitdoefdne GdWg(tercaat°Sdery la3velin;t(1f!Itllnledig lA tad SIG°enf-cdf°Pit,'I PIma adruss Yredr%.,,r,urts; ,;451 —8WC83 Blvd. rter.1stMtedtic (eaud ryeed psi uwrmq ll dllatc;IstddRe r°ss Csismil ur is ACT@e ladag tesgwuT.vs SrRen Eapw,'..1ttdhq. Ill°p!,d,rq,k:cr Kim defzatOff]. Fort Pierce, ,ci Blvd.
(nPlTighl02016AdYoofTrusses- AnthonyT.TombaIII, P.E. Reprodurtionofthis document, in°Wyform,is prohibited without the written permission hors A-IAoDilhusses-AnlhonyLTWmhoIII,P.E.34946
Job
Truss
Truss Type
Qty
Ply
RENAR MORNING SIDE
A0118585
WRMSCMB3L15X10
HJ2
DIAGONAL HIP GIRDER
2
1
Job Reference (optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Wed Aug 29 15:28:55 2018 Page 1
I D:ld_OOXyyT6IBi_TXoljwH HzefvK-g9zvDR6Ku98XAAHiJJgNEB4S WyjhCg?FLSS5JQyiyu6
-1-10-10 2-9-3
1-10-10 2-9-3
c
o m
6
1
r
2-9-3
2-9-3
Plate Offsets (X Y)—
[2:0-0-1 0-0-31
LOADING(psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.25
Vert(LL)
0.01 4-7
>999
360
MT20 244/190
TCDL 7.d
Lumber DOL
1.25
BC 0.14
Vert(CT)
-0.01 4-7
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.00
Horz(CT)
0.00 2
n/a
n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix -MP
Weight: 12 lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-9-3 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. i (lb/size)
3 =
45/Mechanical
2 =
242/0-10-7 (min. 0-1-8)
4 =
18/Mechanical
Max Horz
2 =
80(LC 4)
Max Uplift
3 =
-2(LC 9)
2 =
-127(LC 4)
4 =
-15(LC 19)
Max Grav
3 =
47(LC 24)
2 =
242(LC 1)
4 =
63(LC 22)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsf; h=13ft;
Cat. II; Exp B;i Encl., GCpi=0.18; MWFRS (envelope);
cantilever left and right exposed ; end vertical left
exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the
truss only. For studs exposed to wind (normal to the
face), see Standard Industry Gable End Details as
applicable, or 'consult qualified building designer as per
ANSI/TPI1.
3) Gable studs spaced at 2-0-0 oc.
4) This truss Aas been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 2 lb uplift at
joint 3, 127 lb uplift at joint 2 and 15 lb uplift at joint 4.
8) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 75
lb down and 59 lb up at 1-4-9, and 75 lb down and 59
lb up at 1-4-9 on top chord, and 24 lb down and 34 lb
up at 1-4-9, and 24 lb down and 34 lb up at 1-4-9 on
bottom chord. The design/selection of such
connection device(s) is the responsibility of others.
9) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSIlrPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
10) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
, Plate Increase=1.25
Uniform Loads (pig
Vert: 1-3=-54, 4-5=-20
i
Bcliq-rleuenrnlpNTrinxf5e'6-I IDCf fILYSBj SEtIlI�, skis rttk5 a tDpGtlOis nnJx(5n] ;zUlG&IEGauEAr lua Tc-E! dedp erllallm ldseed lull u I'asL•!v Deslgs hl.iy 1fCa}ld tEe lltlwlT. hall Di, I.t Mlrexe Sltsl Ssn e!t. Ddss! Elknitt tlsle! lE tieTDD,ta'y
NJhia¢Emgsts sSil;:+.lsdfis RlT9eb6elllii. Aseiln: eety![lpr:e;i.e,SseltXl Fi-urelr;,flludll orIDD ntresutt to u¢s'�adAt(rilsslndeg!lE*1"Sp lsiMolitor It, ISSVIttv"flmshpad.,fit TDD lat.mits T.rl. Re MIJe sssmpts. hoints6nnuwlsdrs Anthony T. Tomho lII, P.E.
close this Tslsth•nplsildilg iE l'x rn(x!ikllal di1011eL nR OPatlff w0'IZFlIi'A!'I#t lnlrllDtflPSl,01t!llllrll it lhlllt,763IStLltll lm�tu!ligsllEnitF:T.Itl eppllE[alit TDD OSl nTllGlllSlAIStTIHSS.IA�Ibtpl:5�"�.fp.S:ilpF,llfhdehle fetsnfag lStll}i Ill wJZS.5�I4Tlf - 80083
' I ts'!¢eDlspx!rr3(ee9laa.All otsSol 01itthUDlselit polstsmiritIvS.1IV! hNigfem;awtSony i*mfAn;tC¢jothddoyinarAs1Ulte;It- 11.Punt FlAmIPrletrli@:ilsCNv1119eSeed'.'esofflAmstqnpn,TtexDts'ps50-oiI'm Y.dvvm'ee'sss lvd.
ggSlSt. lueie8
lYEmtl iEfilEl 1paCl9:lselgld enlil lmtiq lydlreaxs iest?!el. IieTnss DenEsTneer':; tCT Ce ra ia7.es:per,nl•lss ppE?!a; lnpnlertelT SldLsp lD to ad&tos lrEmtetedwnll.
(opyright®2016Ad Roof Trusses- AnihonyT.TomhoIII, P.E. Reptodd?l oionofthis doomem,inany War, isprohlbortPierce, FL lvd.
BedwhilcutthtStrivenpermissionfloorA-I Roof Trusses- AnthonyAnthonyLTomholll,P.E.
Truss
WRMSCMB3L15X10J HJ5
Diagonal Hip Girder
[INT16Q. M
AO118586
Fort
truss.com
s May 18 2018 Print: 8.210 s A
ID:Id O0XyyT61Bi
-�--- -.,.....-0.-
1-10-10 .... ,..,.....,,.y,,,
3-9-9 7-2
1-10-10 3-9-9 3_2_9
N�
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
4 =
70/Mechanical
2 =
379/0-10-15 (min. 0-1-8)
5 =
178/Mechanical
Max Horz
2 =
• 141(LC 22)
Max Uplift
4 =
-57(LC 4)
2 =
-152(LC 4)
5 =
-100(LC 5)
Max Grav
4 =
77(LC 19)
2 =
379(LC 1)
5 =
178(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (Ib) or less except
when shown.
TOP CHORD
2-11=-392/103, 3-11=-366/131
BOT CHORD
2-13=-165/346, 7-13=-165/346,
7-14=-165/346, 6-14=-165/346
WEBS
3-6=-383/183
grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live
loads.
3) This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-M wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 57 lb uplift at
joint 4, 152 lb uplift at joint 2 and 100 lb uplift at joint 5.
6) Hanger(s) or other connection device(s) shall be
provided sufficient to support concentrated load(s) 77
lb down and 61 lb up at 1-4-9, 77 lb down and 61 lb
up at 1-4-9, and 32 lb down and 41 lb, up at 4-2-8,
and 32 lb down and 41 lb up at 4-2-8 on top chord,
and 63 lb down and 35 lb up at 1-4-9, 63 lb down and
35 lb up at 1-4-9, and 14 lb down and 40 lb up at
4-2-8, and 14 lb down and 40 lb up at 4-2-8 on bottom
chord. The design/selection of such connection
device(s) is the responsibility of others.
7) In the LOAD CASE(S) section, loads applied to the
face of the truss are noted as front (F) or back (B).
LOAD CASE(S)
Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25
Plate Increase=1.25
Uniform Loads (pin
Vert: 1-4=-54, 5-8=-20
Concentrated Loads (lb)
Vert: 14=-9(F=-4, B=-4)
Aug 29 15:28:56 2018 Page 1
1 McnPddGL2px6iPa5Bersyiyu5
strwq-Valk.'!e(refitnke•aa,ae(nussnruua-bs?ai=tntnsamtanetsnslontana;au+ewcmturI'm
rFrnrltgttoFod,ta�sFaf�ifneffofpot>r.,tin;FttrntFrr.ras>c.rt.matotusets,t:.aoltf3Fa.iftvetFtnttuo,ay
U{TekeasFfnrpf:s;6di ke tfeditr lk Tga la 6e rdil. tsttrrss Detip 6yirxnii.e,S}tfislt(D[{st?F?.®?t!sInFF(1DD ntresatt Fe tmp7;xt AlSF pr¢MFlosciFasFFrit€rtqufililAph; Nae ltsyrtet ttesernss 6!pinel tstleTM!al(, ualerlr�l.Talas?y�nfmtnFss.itrt;e(feFrrnwf.smd�lry Anthony. Tombo III, P.E.
ad of dt5is lsss.`fer u( idlditi is lke restnfililA(dP.a OrY?r,@t Oraitr:sdzF1 F{e9F; 11e ttinits OFsitFrtr,mPxfnhst Fl lie lK, 3s R. sD1t1e 6fdla Fie ¢l MI. itt nsdc11hTD0.dte.fiellrse dN inss. i ,6q iadf sw t, weelFfio FdeMr skAii, n! i:'hFl Y e
' ; f r s H r° w 80083
tti trikrti DFs;ex! F!d QaBtAc. d!' nks sew a dt NO M 1'n psaues®! gnddns ddt tnlGy (tepfam Sdep Ide�nFan(t(7f pN!sEddg l?i cad SIG n. M�tsedfn itFml aaAme n{I h5asftnsiF3.>nlsies n1G'Ia d;:tlnss Dediretlns gnis Faiis?nwlrnss kassltCenr,nsc
rifflln dFfisally0ild'N cirlMti1FVsratlirg1(dl pafFf le0al. rttrnsstnipfi)iFttr I3tcrmFsilsitF11i3tr,Frrnff((y?!9 bjitkfdejfi+ilLca 111 e4 �!1M.t!1 tatm 111AIsnll. 4451 St. Lucie Blvd.
• Fort Pierce, FL 34946
(optTigMQ2pI6A•IRoof imsses-Amhaoyi.Tom6aIII, P.E, teprodoainaofIbis domment,inaarfotm,ispmbi60edwit6ctdthe wFittenparmissionlwmA-Ifluallmsses-Aathonyi.Tam6oIII, P.E.
Job
Truss Type
aty
Ply
RENAR MORNINGSIDE
A0118587
WRMSCMB3L15X10
�Truss
J2
JACK -OPEN STRUCTURAL
9
1
Job Reference (-optional)
A-1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com
Run: 8.210 s May 18 2u18 runt: 13.21u s May is zu11s Mr I eK inaustnes, Inc. vvea Aug la
2018 Pagel
2-0-0
2-0-0
LOADING(psf)
SPACING-
2-0-0
CS1.
DEFL.
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.18
Vert(LL)
-0.00
7
>999
360
MT20 244/190
TCDL 7,0
Lumber DOL
1.25
BC 0.04
Vert(CT)
-0.00
7
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.00
Horz(CT)
0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 9 lb FT = 10%
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 2-0-0 oc
pudins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. i (lb/size)
2 =
176/0-7-10 (min. 0-1-8)
4 =
14/Mechanical
3 =
33/Mechanical
Max Horz
2 =
63(LC 12)
Max Uplift
2 =
-60(LC 12)
3 =
-24(LC 12)
Max Grav
2 =
176(LC 1)
4 =
31(LC 3)
3 =
33(LC 1)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES- i
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsf; h=13ft;
Cat. II; Exp B;lEncl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed; end vertical left exposed;C-C for members
and forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the
truss only. For studs exposed to wind (normal to the
face), see Standard Industry Gable End Details as
applicable, or'consult qualified building designer as per
ANSI/TPl 1. 1
3) Gable studs spaced at 2-0-0 oc.
4) This truss Has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 60 lb uplift at
joint 2 and 24 lb uplift at joint 3.
8) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI/ 'PI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
iP;uriq rlFeseH3nrrFlrEnitatle"AIIDD; IrdSSFSii(Ilfl'16EA9tL1E1i1S6[DXCi11ChS(ISTDM.j dli]';S(ClGG,Eu:IdEMi lFms h-dyhop J...ohnFElrtd mL•sw15i3rre33 i!:p7Freiy(Tfvj rtIlk,dtl{ur7. resa3^;I.LIFfIF!xe Sk;st EF`.ere rtr. DFIFss Ftkt k,tltldro StTDD,w!I
tliTeitereeditlissiiltit rent Ito TODIt ie edol.As aTFess MIT. F,V.uilo.Ssei.De bdwr'�TL.4 to nyTDD npesttls c scort dOr JnMsudFqu!1rJ rml."13di brM!hs:PCIal, VIP Tn3s cry!atofit TOD*,Iyx.In-1. lit brpnvoplw. 1!1:.13namn,"MiD7 Anthony T. Tombo III, P.E.
,id nedfor rnss(e!ul idlibl is 11,.31,'snly d!',0-1,It, Orris'Arta .piOtt ldlli.i Dols,®C!Retool Its K6!IS(nd fie Tito IASl51h.1KI. lerylmF dra TOD.1.aefiell uedti, Tn iaddog imf;wgr,ltfilldi.e Wkmrlsidlit hA te3Jmw1gd «. 80083
I&L;A:6e1 Dtti.gm:.d III! ..Is s0wr a fi2lw ni lit Ima'asmlpielees.11h kory(u!Jw3tl Uhl l»msm.M1(irjplusW i1I710 dSlLi rt!:dnemwhs p.no�,rAmn. lFFl r.SresM!rs Jeu ibe.s�ld!i!sNt!Lrss DRIli.m,Tln3 Dt3�1a F81i1!Hmi rR3iksullh!ela:t3i 4451. St. Lucie Blvd.
.tEnla ldiedlpe{D9'N.nldap.urrti.J lJ dliMiF31Ee:I3eSBoTn33No. Etleeet is NOT tiela'-0A1 Usiper,w7rc3 Sp!!m l imi el.1 t4iil.All["a-id l!i`<;Clr ae os aeradlaRll. Fort Pierce, FL 34946
(opyrighl02016A-I Roof Trusses-AnlbanyLTomba111,P.T. ReproduoionofThis dommeni,inany Turns, isprohibited withoutthewriltempermission from A-1RaofTrasses-AnthonyT,Tomhatll,p,T.
Job
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE
WRMSCMB3L15X10
J5
Jack -Open
4
1
A0118588
A
Job Reference (optional)
1 Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MiTek industries, Inc. Wed Aug 29 15:28:57 2018 Page 1
ID:Id OOXyyT61Bi_TXoljwHHzefvK-dY5fe78aQmOFQTQ4QktrJcAk91KOgaVYolxCOlyiyu4
-14-0 5-0-0 1
1-4-0 5-0-0
BOT CHORD 2x4 SP No.2
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 5-0-0 oc
purlins.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
- MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
3 =
113/Mechanical
2 =
269/0-8-0 (min.0-1-8)
4 =
59/Mechanical
Max Horz
2 =
123(LC 12)
Max Uplift
3 =
-81(LC 12)
2 =
-98(LC 9)
4 =
48(LC 9)
Max Grav
3 =
113(LC 1)
2 =
269(LC 1)
4 =
88(LC 3)
FORCES. (lb)
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; end vertical left exposed; porch left
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
2) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
3) ` This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 81 lb uplift at
joint 3, 98 lb uplift at joint 2 and 48 lb uplift at joint 4.
LOAD CASE(S)
Standard
6ndry�tlnse lhu-rytJrmhntfe'A1 tGGpnlSssl`>Enn�Gre:atrtuuamrtnGestusTGns ruie�;uenGat �>xinr hrz feifr ktlys ratmdmtNned nsltsplsis LessiesirftDs�iylfk;;t�ntatsari.tnp>a!r.E.rdntatu>srh;tt�:. Ddtt: drn.iee dddtenemD,vay
XPtkasrmup!des stdi Ea atedLrth19D 1-htdll. ee tlrr, Dili- T-pl—e e,Speddlt hilts-ei,tit stil to mpTOD uprestdut nnpsardIs, rrdewndegxr:I,Ju4us!10ot..! It, dwyndno sttpsTrus04 d n 6, TOD alp, esfuIN. Th Mips nsmpti-c. l-edapmente, stnd!II¢ Anthony T! Tombo III, P.E.
ad -n dthis rrtss4rtephdld--is lh nspit!itilnr drkOw-r.lh GWdlst°WidlpW wlit dditi-E Oedgv,nhastarts dta IK,A-!p; ulth 6til WfigmhadMI. Thelpmei d lie TOD esI-nhillis, dNe sR:rye,i-awidi-- oil hnspstill4t t!a ngaslt_e:¢ d t80083
i
sit hlegOr$"?AQ"dl!. All rEIssdalkrteTDDnllhplcdiusrrdd}.if9msdtetldfiqfrtpaedSfglismmnR('A;pdhsh:tifiNSKAiiW—o9htpem!ptidm_1tHk9asAertsp.A61esudd">sd9-LntDtnpti.1woap',P,r®Irnssu„dtaen;wxss 4451St. Lucie Blvd.
sinrlu lsti-dtpDCe9:�-pesd->•tuxdnry lT dipmnlndreL 6eTnu Nit;i[q eer is 101b I4:227 Cetgaer,nThss sish. Ea w,01. of hDtispFort Pierce, FL 34946
EopTTight 0 2016 A-] RooETmsses-AnlhonyL Tembe 111, P.E. litomdudion alibis domment, in onyhrm, is prohibiied without the written permission from A-] RoolTmsses-AuhonyL TomhD 111, P.E.
Job r
Truss
Truss Type
Qty
Ply
RENAR MORNINGSIDE
A0118589
WRMSCMB3L15X10
T01GE
COMMON
1
1
Job Reference (optional)
A-i mooT Iuusses, ron rterce, rl svuvo, oesigntaalwss.com
rtun:o.cIl/5 Witty ,ocUtonnls.o.4IVA
ID:ld 00XvvT61Bi
I
14 3-0-2 4-8-0
111 1-7-14 1-7-14
U4 =
ya:><eslse�e
10—IU svn,— ueuuauew, uw. XXeae.Xuy— w--- -- ,
4-8-0 6-3-14 1 7-11-12
9-4-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
TCLL 20.6
Plate Grip DOL
1.25
TC 0.35
Vert(LL)
0.05
13
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.40
Vert(CT)
-0.04
13
>999
240
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.10
Horz(CT)
0.00
11
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MR
LUMBER- i
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3
BRACING -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc
purlins, excep( end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required
cross bracing be installed during truss erection, in
accordance with Stabilizer Installation guide.
REACTIONS. (lb/size)
15 = 418/0-3-8 (min.0-1-8)
11 = 418/0-3-8 (min.0-1-8)
Max Horz
15 = 76(LC 11)
Max Uplift
15 =-170(LC 8)
11 =-170(LC 9)
Max Grav
15 = 418(LC 1)
11 = 418(LC 1)
FORCES. (lb)I
Max. Comp./Max. Ten. - All forces 250 (lb) or less except
when shown.
WEBS
3-15=-200/335, 7-11=-200/335
NOTES-
1) Unbalanced roof live loads have been considered for
this design.
2) Wind: ASCE 7-10; Vult=160mph (3-second gust)
Vasd=124mph';, TCDL=4.2psf; BCDL=5.Opsf; h=13ft;
Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope)
and C-C Exterior(2) zone; cantilever left and right
exposed ; endi vertical left and right exposed; porch left
and right exposed;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) All plates are 1.5x4 MT20 unless otherwise indicated.
4) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
5)' This truss has been designed for a live load of
20.Opsf on the bottom chord in all areas where a
rectangle 3-6-0 tall by 2-0-0 wide will fit between the
bottom chord and any other members.
6) Provide mechanical connection (by others) of truss
to bearing plate capable of withstanding 170 lb uplift at
joint 15 and 170 lb uplift at joint 11.
7) This truss is designed for a creep factor of 1.50,
which is used to calculate the Vert(CT) deflection per
ANSI(TPI 1. The building designer shall verify that this
parameter fits with the intended use of this
component.
LOAD CASE(S)
Standard
1-4-0
PLATES GRIP
MT20 244/190
Weight: 47 lb FT = 10%
11"Weg-finse tk nall4t nitwtke'Ad loci IM53 SE11E11 Df4:1111r1NS 6 [Ogrd005t (DSi01ly LltP:l'j i(CIOBLD MENi hrx. rut¢ desip FrIa.0m ea! al An WAslars ont, ir¢.iy I((G;; W de Aticsrl.leal¢Ci, I' Lletmae Site i:5, K!. DdF33 f3(e!a:e a!Sd FenF1oD,�y
MlTekmet!prjfes sldile oaf forite TDD10 ienhf. hlLns Desigt itgieujl e,5re:hDr Ftprelrrf!!s!tlnnJ lDD reputtls le u¢}f�ssi@e iratst9nd egaeritg r±stFFsilOtt('¢;!11eK!pa ElCe f+fFrmsf!r;n!I lerielrlD alr,.>terirl. Rx iK!p n3mg3ilc.iFc{xgm6nx!. nn¢lilr( Anthony T. Tombo Ill, P.E.
mine ifsfsns`1rt¢rtelki if It, minsiHnh AN 0.1"th Owuiseaaitrtlp¢ir. ik ldllin Despr,at" rnhddlL let, 5!IS: aide asd kwfz,all Sxl Mi. It, qpn'. A tke IDD¢sl FnAddKatttainss,od'dglM-.su-ge,10,11din Fld kste.q sith hs re!rsaekryo S$0083
' Ilt,.a.:DFsig'ir4crwcAll..its311Mitthmoiliepsiiasiadpie6rsilk±Gileiq[scyaen SdFrylxnmm¢tjr(SPplti3Ee1lJPIallSiusarthae lhap¢nrlp:dmc±.TPHEeSnsl±rssp^s4rhisWiStiKN!!LKsDmilimlissDes'.rsrngtrermilrnsWsret!,mns 4451St0083 Lucie Blvd.
tlI-aldildllnC.Aredipe[dtgl¢a Xldlep lr siliM:Ff IEtEliFd. lkelmiD<Slgl(H(RlrlS eDlt%,AA9)DKIpK,irl'F!SSfL!A [¢j0Y1fC¢J le�i1�. iJl lu"p .�!d tP31(F¢S dF�9P�hlrl1,
(opxighl02016A-ltoollrusses-AnihonyLTomhoIII, P.E. Reproduction of thisdommenl,inaoyfmnn,isptobibiadwithoutthewrittelpermissionfromA-1RoofTresses-AnthonyLTorrhoIII,P.L Fort Pierce, FL 34946
JAN UARY 17, 2017
TYPICAL HIP / KING JACK CONNECTION
STDTLOI
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
CORNERSET GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 175 mph, ASCE
7-10, Exp. B, C up to 60' Mean Roof Height
and Exposure D up to 30' Mean Roof Height.
/'
Attach End Jack's
w/ (4) 16d Toe Nails @ TC
& (3) 16d Toe Nails @ BC
Attach King Jack w/ (3) 16d Toe
,Nails @ TC & 24" Strap w/ (6)
10d x 1.5" ea. end @ BC
i
0
J
ti
ttach Corner Jack's
r/ (2) 16d Toe Nails
@ TC & BC (Typ)
Attach Corner J,
w/ (2) 16d Toe Nails
BC (Typ)
MA
IioWltlrosit�o-'f+Smirr'1 I:JI,RCS;Sj'it!(Q`561�ii11f%diaS[[CR1;K C�4lhJ}U'jhJ!WWEn:�ht hiM1 fug[uPlstaie:TTizrarttin'k.&�}Fv�g2-reJ70�ei4 lupgT.isn3Jtf.hatedJdce eit lk.etavr t64iat�.IHJ.w¢
r;duk 3i�sss ieruE �itemJer .:t:a4ssoiH [is F.spvnfta #aa sa rm.reu�ane nest �exa�ec sgrtmatiraras rin�kPe rsa�ckaro t ml.�e nl.ertnjannli isegsdr.e�umiuf AnthwyLjjb bo11I PX.
.. cidast$s irsss4rce+fullivp6:+n7cm5.:maf!a6.0:ce�rntWnttiz3raintGrt+Atstesm.;.titktck!usl rstMutfin9lhs m;dlrilCnl uErm.tli1.:§tq[:ara!Ra P�.�csi �:.II uMd+tTsu. r.�r'seaalaS�ptptrge. asc3?cerGNwrg+sdi 4eKarrcyrat30ryd. .".189083� .
' r,erua [� as oci�r;i r s,rl�sn ie as+klm es�sy�x ra�rt�;111L sd h +x�[sq► uwt ,n�ex��e nano[ r , a*I;, r e un�d r d,t ,jna yuw 5 e�ze�T sa ;,aa„ 4451 St..tuele Sivd:.
�ussi:�tti`a�kr,r*utspss�era�w.rwg4r�+ax m drtd issTttnLss�+fg3isnXfee(e.i'gGrsi�mv.n[cn�^�Gtok.dn 6a7�5 S:ier�a t+ama!ie}dzRw�RFf, fotYPiet[e, FL 3a9db�.
Tap,dpEt W1lest[toss.sAn>cony7:Ta�aIIEP.F,Sl�0�9tl19P0I1t�Siouo",inooyhfvjhp-�IEitPAiO*0140-evi"Titape(.04thfAA..WOTfQ41tSAESI00YI.Tpphd01,P.f;
�i
�FEBRUARY 17, 2017 I ALTERNATE GABLE END BRACING DETAIL I STDTLO
A-1 ROOF TRUSSES
4451 St. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
I
ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORO
I'-3'MAX.
DIAG. BRACE
AT 1/3 POINTS
IF NEEDED
I
IT IS THE RESPONSIBILITY OF THE BLDG.
DESIGNER OR THE PROJECT ENGINEER/ARCH
TO 13ESIGNITHE CEILING DIAPHRAGM AND IT
ATTACHMENT TO THE TRUSSES TO RESIST /
OUT OF PLANE LOADS THAT MAY RESULT FI
THE BRACING OF THE GABLE ENDS.
i
2X6 DIAGONAL BRACE SPACED 48'
O.C. ATTACHED TO VERTICAL WITH
(4) - 16d NAILS, AND ATTACHED TO
BLOCKING WITH (5) - 10d COMMONS.
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO 16d NAILS.
2X4 PURLIN FASTENED TO FOUR
TRUSSES WITH (2) - 16d NAILS
EACH. FASTEN PURLIN TO BLOCKING
W/ (2) - 16d NAILS (MIND.
PROVIDE 2X4 BLOCKING BETWEEN
THE TRUSSES SUPPORTING THE
BRACE AND THE TWO TRUSSES ON
EITHER SIDE AS NOTED. TOENAIL
BLOCKING TO TRUSSES WITH (2) -
10d NAILS AT EACH END. ATTACH
DIAGONAL BRACE TO BLOCKING WITH
(5) - lOd COMMON WIRE NAILS.
CEILING SHEATHING
BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1:IATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE
OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAIL SCHEDULE.
METHOD 2:1ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL
MEMBER ON -THE STRUCTURAL GABLE PER THE FOLLOWING
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG
SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL
NAILING SCHEDULE:
- FOR WIND SPEEDS 120 MPH (ASCE 7-96, 02, 05), 150 MPH (ASCE
7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131'
X 3') NAILS SPACED G' O.C.
- FOR WILD SPEEDS GREATER 120 MPH (ASCE 7-9B, 02, 05), 150
MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d
(J31'X3'J NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM).
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI
BRACING METHODS SHOWN ON PAGE 1 ARE VALID
AND ARE TO BE FASTENED TO THE SCABS OR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
URAL
TRUSS
2TIIn
STRUCTURAL AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING
GABLE TRUSS MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF
/ THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS.
THE BRACING SHOWN IN THIS DETAIL IS FOR
VERTICAL/STUDS ONLY.
NOTE: THIS DETAIL IS TO BE USED ONLY FOR V
STRUCTURAL GABLES WITH INLAYED /
STUDS. TRUSSES WITHOUT INLAYED
STUDS ARE NOT ADDRESSED HERE.
j / .
STANDARD GABLE /
TRUSS
JULY 17, 2017 STANDARD PIGGYBACK TRUSS
CONNECTION DETAIL STDTL04 -,
r.
THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS:
ASCE 7-98, ASCE 7-02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSUR`E�
CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN)
DRAWING FOR UPLIFTS.
-- -- --•-~~ NOTE: THIS DETAIL IS VALID FOR ONE PLY TRUSSES SPACED 24" O.C. OR LESS.
rw.Nw�:
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
PIGGYBACK TRUSS
REFER TO ACTUAL TRUSS DESIGN DRAWING FOR
ADDITIONAL PIGGYBACK TRUSS INFORMATION.
SPACE PURLINS ACCORDING TO THE MAXIMUM
SPACING ON THE TOP CHORD OF THE BASE TRUSS
(SPACING NOT TO EXCEED 24' O.C.) A PURLIN
TO BE LOCATED AT EACH BASE TRUSS JOINT.
1n:an mia
ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2" X 8"
TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48" O.CI PLATES
SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48" O.Cj
STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH
FOUR (4) 6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHIEVE ,'MAXIMUM
UPLIFT CAPACITY OF 377 LBS. AT EACH 2" X 8" TEE -LOCK MU lTWSE
CONNECTION PLATE. (MINIMUM OF 2 PLATES)
I Rooflissses:pdayL
ATTACH EACH PURLIN TO THE TOP (CHORD OF
THE BASE TRUSS.
(PURLINS AND CONNECTION BY OTHERS)
BASE TRUSS
REFER TO ACTUAL TRUSS DESIGN DRAWING �(
ADDITIONAL BASE TRUSS INFORMATION.
Anthony T. Tombo.I11;,P.E.
' $00831
4451 St. Lucie 810.
Eori,Perce, FL 34946
JULY-17,' 2017
TRUSSED VALLEY SET DETAIL -SHEATHED I STDTL05
�i
A-1 ROOF TRUSSES
44 1 rn- of ,ate
FOF
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 4.5" WS45 USP OR EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL "A".
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NDS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
-E END, COMMON
iS, OR GIRDER TRUSS
TRUSS CRITERIA:
SECURE VALLEY TRUSS WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
W/ ONE ROW OF 10d WIND DESIGN PER ASCE 7-10: 170 MPH
NAILS 6" O.C. MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24" O.C. (BASE AND VALLEY)
SYP TO THE ROOF W/ TWO USP MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
WS45 (1/4" X 4.5") WOOD SCREWS
INTO EACH BASE TRUSS.
DETAIL A
IEpb�CiOstb!ttP=�11,¢rR�te;'!-I l�jt iOh?ii„EiiE�'E.6iMrlf1[tilidtOEK.rsStC;f9lt,ES?ti''tt�;l:U1SLtT hra eidp t��;ntmnr'ss saI[e.�'.est-saaszs7;zs}CiaylEwuagj.0,mltulaeasi ic�ti,lt ld ic�elasi bt6.�eu, 5olns e'�iesM dmagip0:iaEr .
fiii¢i:aar"fei� bslrr'frattdil3 tla i!dlslr rCd Iil iFiSf[Yd�vlgnrl}ri„Sp(m7f Eapi?t.+>?�a FBd asm e0D?aiff ?1'saxjiiixt tatK eS:�sae Ng>atri RtE:d7ak1 1t tIds7..tam3¢.L]jl{itrase iykiw fu?<'m7f�p N 1. I�t dS�Ja#11 EC+>gb?E>bl�Ur�esatir tis!p?i3p Anthbh 4, TOmbo III, P.E
ndaa ai6:sTussMap3 da.aq 3s 5ieispaaxia0iry al K>t O�sie :t Q�ntlsesdisittf e;e ee C:r dx. ,;tnssrur at5t ¢qr tlSasiCfi .3: iidU�a �avf'amt4:tt�taiiifl .ldt apF'srm'a!C,t iTPuf mT!;sNasapcie Taus;tivedir; kna .ad tkraji;n tllCsmm6 its x+nitbt6s ujatilllspat T 80083
fa/a;9ts} eaflhaRxfa[nstlaimnes33adta7iMas3gczbzdeLelidauyas3C tda�w{lSfjppbtI5rFImdR}�atncua}4rinauy'a¢.Rlir•`cs¢[seyem4?umJAnsuetrnssltpae.krisCsyE�eZairrltxdakn,eas .4451 St, Lude Blvd.
' s5q"atea aadlT+u'a�Es ead�Ta+v r n;E.tAla(iiss%raijsd Sb ?sifm'D fs.aeniscJ;snatwt�Prnta r gtmi;psha:Fpsrdmi�dda .4flnKK!iri�;Etratirea ti+elblPt4.. Fott P.iei.ciell FL- 34946.
�CopTragkt�`J1ilEGA•iRo�tTrsses-Amt6nagt,TuTrbulA,P.E.Rep:oduaiaaeiltis`dcrosem,innsyietm;np�E.aoad�;ESoxifhe�6tienFetr.�ssi�ntrumk-Eioc(frnsscs•pnrboa?yE;Tom4dtll;P.E
FEBRUARY 5, 2018
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6" O.C.
TRUSSED VALLEY SET DETAIL I STDTL06
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 3" WS3 USP OR EQUIVALENT.
3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL
"A•
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
DRAWINGS.
5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
6. NAILING DONE PER NDS - 01.
GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
TRUSS, OR GIRDER 1 TRUSS I
DETAIL A
(NO SHEATHING) N.T.S.
BASE TRUSSES
VALLEY TRUSS
GABLE END, COMMON
TRUSS, OR GIRDER
TRI I.¢St
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
ATTACH 2X4 CONTINUOUS #2
MAX TOP CHORD TOTAL LOAD = 50 PSF '
SYP,TO THE ROOF W/ TWO USP
MAX SPACING = 24" O.C. (BASE AND VALLEY)
WS3 (1/4" X'3") WOOD SCREWS
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
INTO EACH BASE TRUSS.
Ycar77 5ailig�t w� I!•'1-I ICSt tliki{'RiI;I�:EEIrIStiEUlSS4FSli aii (@itdR{Y!?Ei'j7: [41f.�Sdist'Cnm t �'lievjepume;:l wl:idwgralk� ms@�i#i.ciT(3-lnl i�l irflwyF aa�,A:lI:1{r.n'k�difct ne�less i5s.::iesM:taex_Igms
YTak s�ra:llees si2J#r s,t'rrtitiP#6r.C;l. Iarrriisnas�p tq:lzls{ri,�li�{,gyur Mi!'edar �gi#sigaxesm,,rpai�'�{pok;aa+dagrukt�ie prsivaj��fM,'ullrtH+ic.�;Ciser iim Gi iUiler.culiKi. Tel dliensrnt�s:�kp#rdhii�l,!-rii';N;
isitip6 sTlasslen8 �skeii �mrtR�o.rer,:�so.ussaaeiapxRnet�ar ,ri nvpo-l5{[,.aluuaeixrunti�i€asair�tiugpa;amdurtn�r An
r@elFuedaernsxla i��n:,ugr,n«;aainafruigs 5iealesr aget ii{onl'T.'orgI11"O.E.
ZE
eM @±� (t'�fYliL(w(!{f{p A,.Ip4$N{ifglipit"�4+ARi rfid:t4lMp�ifrallSid Al@�:3` (iRjlid6 gaNj �j(¢7flp. p¢2{rJ1§rf SriNpEi$ii Rt'/a:N�fi4$11( (Il$411t'ji{)¢ .lilil ll'A,teS: Uli064. yirRp.iAESi1E.�A1r,SIKS@ti'Qt: j(3{i 9."G'+,L'6f:�1tii1{ 800
3aervuat `a IFy rGskadsRcriip!®.rajgh drNus aei.{3 Tbi lnSstaigl 1poerrss.I!iikS#iq Fe p{r.rr inaSm 4FmlydnJbtGsg ii'ta Irefkia{areee fAlzik€RC 4451:Sf Lucie Blvd.
(cpF�,htO.Dl64-lFailltessrs-A01h, .ie�9otpPf:Ft�otunman{tknEosupamltcnyteimisp{o�IFirdwhmrteernenpecalssia�mmA•IFeefT{'esser;Act6anyT.Tamk�(pF,i Fort Pierce" FL 344A6
JULY17, 2017 I I1%V%'%.71__L' MILLI_ 1 1 lIIL
(HIGH WIND VELOCITY)
STDTL07
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE; FL 34946
772-409-,1010
ATTA(
I
WIND DESIGN PER ASCE 7-98, ASCE 7
WIND DESIGN PER ASCE 7-10: 170 MPI
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY II BUILDING
EXPOSURE B ORC
WIND DURATIONIOF LOAD INCREASE:
MAX TOP CHORD TOTAL LOAD = 50 PSI
MAX SPACING = 24" O.C. (BASE AND VP
SUPPORTING TRUSSES DIRECTLY UNCICK VALLCT I KUJJCJ MUJ I Or —
DESIGNED WITHiA MAXIMUM UNBRACED LENGTH OF 2' - 10" ON AFFECTED
TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER.
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
NON -BEVELED
BOTTOM CHORD
CLIP MAY BE APPLIED
TO THIS FACE UP TO A
MAXIMUM 6112 PITCH
FBI
CLIP MUST BE APPLIE
THIS FACE WHEN I
EXCEEDS 6/12 (MAX
12/12 P
NpG6j Pgit aiP+p
hfhtirtata^mpuYsjl
- Ai
st4a�sdPn U ss Q>
At EalbStasglx�si
t5e>; cidiiPJ i?Pf
IE
IfPRin atSWsr�2P jrtmces poip .�J�as�ste lai3's}la�gmeaSee7od nusl�t*.�P'aPeE6'TfN^-+iSN�t ¢tnfeit2ftdd la�l *s VI,4hutrtetupnzE»ma[uA €aln dot
tt: f7aipn5nkt5w' lbs a+ssA w�FsgnxsnoMJTd l 6[ pe a;T tsi�nrnGS�ntt�slFtMd{aq Sim�]6�P.mmsvga Hmim'P i
Antliony T. Tombo
80083
4451 SL Lude Blvd.
Fart Pike, FL '34946,
FEBRUARY 17, 2017
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
STANDARD GABLE END DETAIL
TYPICAL 2X4 L-BRACE
NAILED TO 2X4 VERTICALS
7z;
VERT
STUD
SECTION B-B
VERTICAL
STUD
(4) - 16d
NAILS
(2) 10d NAILS
INTO 2X6
2X4 SP OR
SPF #2
TRUSS GEOMETRY AND CONDITIONS SECTION A -A
SHOWN ARE FOR ILLUSTRATION ONLY.
DIAGONAL BRACE 4' - 0' D.C. MAX.
SEE INDIVIDUAL ENGINEERING DRAWINGS
FOR TRUSS DESIGN CRITERIA.
12 PROVIDE 2X4 BLOCKING BETWEEN
Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED.
TOENAIL BLOCKING TO TRUSSES
* WITH (2) - 10d NAILS AT EACH END.
ATTACH DIAGONAL BRACE TO
BLOCKING WITH (5) - 10d NAILS
'A
STDTL08
i
2X6 SP OR SPF
#2 'DIAGONAL
BR CE
\ I
16d NAILS
SPACED 6' O.C.
r- 2X6 SP OR
SPF #2
I
TYPICAL HORIZONTAL
BRACE NAILED TO
2X4 VERTICALS
W/(4) - 10d WAILS
/
Bd MINIMUM, ROOF
3X4=
P(4)
LYWO DNAILS SHEATHING TO SHEATHING
B
2X4 STD SPF BLOCK
*
DIAGONAL BRACING ** L - BRACING REFER
REFER TO SECTION A -A TO SECTION B-B 24' MAX.
NOTE:
/
1.
2.
MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS.
CONNECTION BETWEEN BOTTOM CHORD
I (2)- 10d
/
OF GABLE END TRUSS AND WALL TO
12'NAILS
BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3.
BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG.
ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF
-
4.
SYSTEM.
'LBRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR
/
BETTER WITH ONE ROW OF 10d NAILS SPACED G' O.C.
oTRUSSES @ 24. O.C.
5.
DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM
AT4'-0' O.C.
S.
CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN
2X6 DIAGONAL BRACE
WITH 16d NAILS SPACED 6. O.C. HORIZONTAL BRACE TO BE LOCATED AT
SPACED 48' O.C. ATTACHED
THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE
_ TO VERTICAL WITH (4) -
STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A)
- 16d NAILS, ANDI ATTACHED
7.
GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240.
TO BLOCKING WITH (5) -
B.
THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAG. BRACE 10d NAILS.
9.
DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3
POINTS
TRUSSES. IF
NEEDED
10.10d
AND 16d NAILS ARE 0131'X3.0' AND 0131'X3.5' COMMON WIRE NAILS
HORIZONTAL BRACE
RESPECTIVELY.
(SEE SECTION A -A)
11.
SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12
BY SPIB/ALSC.
MINIMUM STUD
SIZE SPECIES
AND GRADE
STUD
SPACING
WITHOUT
BRACE
2X4
L - BRACE
DIAGONAL
BRACE
1
(2) DIAGONAL
BRACES AT
1 1/3 POINTS
MAXIMUM STUD LENGTH
2X4 SP 43 / STUD
12" O.C.
3-8-10
'5-6-11
6-6-11
11-1-13
2X4 SP #31 STUD
16" O.C.
3-3-10
4-9-12
6.6-11
9-10-15
2X4 SP #3 / STUD
24" O.C.
2-8-6
3-11-3
54-12
8.1-2
2X4SP#2
12"O.C.
3-10-15
5-&-11
6-6-11
11-8-14
2X4 SP #2
16" O.C.
3-6-11
4-9-12
6-6-11
10-8.0
2X4 SP #2
24" O.C.
3-14
3-11-3
1 6-2-9 1
9-3-13
DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE
EDGE. DIAGONAL BRACES OVER 12' - G' REQUIRE 2X4 I -BRACES ATTACHED TO
BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE
WITH 10d NAILS 6' D.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER
9OX OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2.
END WALL
MAX MEAN ROOF HEIGHT = 30 FEET
EXPOSURE B OR C
ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS.
T-BRACE / I -BRACE DETAIL I
FEBRUARY 17, 2017 WITH 2X BRACE ONLY STDTL09
i
NOTES:
T-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING
IS IMPRACTICAL. T-BRACE / I -BRACE MUST COVER SOX OF WEB LENGTH.
THIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS TO
CONTINUOUS LATERAL BRACED WEBS.
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT RIERCE. FL 34946
NAILING PATTERN
T-BRACE SIZE
NAIL SIZE
NAIL SPACING
2X4 OR 2X6 OR 2X8
10d
6' O.C.
NOTE: NAIL ALONG ENTIRE LENGTH OF T-BRACE / I -BRACE (ON
TWO-PLY TRUSSES NAIL TO BOTH PLIES)
NAILS
SPACING
k
BRACE
SIZE FOR ONE -PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T-BRACE
2X4 I -BRACE
2X6
2X6 T-BRACE
2X6 I -BRACE
2X8
2X8 T-BRACE
2X8 I -BRACE
BRACE
SIZE FOR TWO-PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T-BRACE
2X4 I -BRACE
2X6
2X6 T-BRACE
2X6 I -BRACE
2X8
2X8 T-BRACE
2X8 I -BRACE
T-BRACE / I -BRACE MUST BE SAME SPECIES
AND GRADE (OR BETTER) AS WEB MEMBER.
NAILS NAILS
WEB 1(
NAILS WEB
I -BRACE T-BRACE
SECTION DETAILS
FEBRUARY 17, 2017 I LATERAL BRACING RECOMMENDATIONS STDTL10
r.,
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS
2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET
ALONG A FLOOR TRUSS.
NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE'POSITIONED DIRECTLY UNDER THE
rr.rr� TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING
A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW.
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR 1
772-409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOI
FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPEI
CONNECTED, BY OTHERS, AT THE ENDS.
USE METAL FRAMING
ANCHOR TO ATTACH
TO TOP CHORD
BLOCKING BEHIND THE VERTICAL
WEB IS RECOMMENDED WHILE
NAILING THE STRONGBACK
ATTACH TO VERTICAL
WEB WITH (3) - 10d
NAILS (0.131' X 3')
USE METAL FRAMING - ATTACH TO VERTICAL
ANCHOR TO ATTACH WEB WITH (3) - 10d
TO BOTTOM CHORD NAILS (0131' X 3')
ATTACH TO VERTICAL
SCAB WITH (3) - 10d
NAILS (0131' X 3').
INSERT WOOD SC
OUTSIDE FACE Of
EDGE OF STRONG
USE DRYWALL TN
rATTACH
WEB WI
NAILS (
ATTACH 2X4 VERTICAL
TO FACE OF TRUSS.
FASTEN TO TOP AND
BOTTOM CHORD WITH
(2) - 10d NAILS (0131'
X 7) IN EACH CHORD
ATTACF
WITH
WOOD !
(0.216'
ATTACH TO VERTICAL L INSERT SCREW THROU[
SCAB WITH (3) - 10d OUTSIDE FACE OF CHC
NAILS (0131' X 3') EDGE OF STRONGBACK
USE DRYWALL TYPE Si
TRUSS 2X6 4' - 0' WALL
STRONGBACK (TYPICAL SPLICE) (BY OTHERS)
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT,
DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB
CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3')
EQUALLY SPACED.
ALTERNATE METHOD OF SPLICING:
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) -
10d NAILS (0131' X 31 STAGGERED AND EQUALLY SPACED (TO BE USED ONLY
WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL).
BLOCKING
(BY OTHERS)
THROUGH
CORD INTO
K (DO NOT
SCREWS)
VERTICAL
(3) - 10d
I' X 3')
TO CHORD
'.) # 12 X 3'
INTO
NOT
I
FEBRUARY 17, 2017 LATERAL TOE -NAIL DETAIL STDTL11
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT OIERCE. FL 34946
Pi
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45" WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN
THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS
SHOWN).
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL
BE SUCH AS TO AVOID UNUSUAL SPLITTING OF. THE WOOD.
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO
SPECIES FOR MEMBERS -OF DIFFERENT SPECIES.
I '
TOE -NAIL SINGLE SHEAR VALUES
PER NOS 2001 (LB/NAIL)
DIA
SP
OF
HF
SPF
SPF-S
.131
88.0
80.6
69.9
68.4
59.7
z
135
93.5
85.6
74.2
72.6
63.4
J
in
.162
108.8
99.6
13
84.5
73.8
ri
128
74.2
67.9
58.9
57.6
50.3
o
z
0
J
1 .131
75.9
69.5
60.3
59.0
51.1
N6
1 .148
81.4
74.5
64.6
3.2
52.5
"
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0162' OIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD
FOR LOAD DURATION INCREASE OF 115:
3 (NAILS) X B4.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY
45.00'
THIS DETAIL IS ONLY APPLICABLE TO
THE THREE END DETAILS SHOWN BELOW.
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
NEAR SIDE
SIDE VIEW
(2X4) 3 NAILS
NEAR SIDE
FVT-NEAR SIDE
NEAR SIDE
0°
SIDE VIEW
(2X3) 2 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
NEAR SIDE
DO°
FEBRUARY 17, 2017 UPLIFT TOE -NAIL DETAIL STDTL12
I
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
THIS DETAIL SHALL BE USED FOR A CONNECTION
RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER
IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS.
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30• WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM TIE
MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AV DID UNUSUAL SPLITTING OF THE WOUD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION.
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE
FOR WIND DOL OF 1.33:
3 (NAILS) X 37 (LB/NAIL) X 1.33 (DOL FOR WIND) = 146 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
FOR WIND DOL OF 1.60:
3 (NAILS) X 37 (LB/NAIL) X 1.6D COOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LEIS (177 LBS) BUILDING
DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION.
USE (3) TOE -NAILS ON 2X4 BEARING WALL
�!* USE (4) TOE -NAILS ON 2X5 BEARING WALL
NEAR SIDE
FAR S]
)E
TOE -NAIL WITHDRAWAL VALUES .
PER NOS 2005 (LB/NAIL)
OIA.
SP
OF
HF
SPF
SP�F-S
L7
I
.131
59
46
32
30
20
Z
O
J
.135
60
48
33
30
20
('7
.162
72
58
39
37
25
J
=
F-
O
.128
54
42
28
27
I
19
L7
Z
Z
OJ
.131
55
43
29
28
19
LU
.148
62
48
34
31
21
-I
Lo
J
CV
Q
M
Z
.120
51
39
27
26
17
�
O
Z
.128
49
38
26
25
17
O
.131
51
39
27
26
17
J
.148
57
44
31
28
20
I
TOP PLATE
OF WALL
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
IL:
NAIL
NAIL
SIDE VIEW END VIEW
4.1
F�BRUARY 5, 2016
TYP 2x2 NAILER ATTACHMENT STDTL13
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
April 11, 2016
TYPICAL ALTERNATE BRACING DETAIL I STDTLI4
FO EXTERIOR FLAT GIRDER TRUSS
A-1 ROOF TRUSSES:
4451 ST. LUCIE'BLVD.
FORT PIERCE, FL 34946
772-40971010
(4) 12d
TRUSS 2411 O.C.
UPLIFT CONNECTION
(SEE ROOF TRUSS)
EXTERIOR FLAT
GIRDER
12
VARIES L��
(4) 12d
MAX '3011 (21-61)
2x6 #2 SP (Both Faces)
2411 O.C.
SIMPSON H5
i
x+'ra3•l7mtem 7�..'>•Ik•e.i kG�7ItP44FS'.19Cft'j6[iitA; TilYtktCt➢l�JziCiisiCYy'k4tf1 EAPICY,:S tiN^lus. Ixfii huPlnaatM, oinNaht Airs rAt u�.nT41T ;atrM ieaw.r.7+skel/.E,kAeiuw,SeNkkt rm. ➢il+NrMn•N t?eNaM log, W. .
kIN smon,iwa is knN!tt hF hk uM. li.tr Dropt ataea s,« ykz�ian 6t I tq lDDrgrnxntn wu/asAM,a!n4rai nj'tMy Ns s:;a: to rta s kem,hg: toss e. a<,a,taatd,..:talna, terhnir rs,t„ate ca-ns:r zi', q,rthony T. Tam:o III, P.E. ei n lf;-T•niW s.;sta3starg sc-3ndM1e➢.m W➢neheeiuulax&ppftcg➢use!,uan,aaim ti 6x l:.�M.aNf,t hx'ledtW iW na ni irnpm5d De 3➢Ga�trti;dsu dbe lhikdsy%ealiayti%ye.WhlliGn asnrhi slel kYauip"lyd 9$0093 ' ;ffi Wtsk w,mad,x.nmlAmhstgsaaaeTasnt Nadi bslgmh:arsst»at 8�'d+gtersteail,slAhlermmw 7[sCplHseN4t1s1oySltta:t rdetmd kro rymdsi,.dnrs.r7>t lRwskrn+y.siJrvsMd+>esdettsnAFasspars.tms'nup&p�rrsdTnn Awha•xtr,ment
mmsrise NGMkA (etxmi tpxNeµn aaswq k)e2,a` 4'r!rN It, tems NTEap. is rwt a vuOjF t�,,m,al s t,s', E )iaen deei9 hat. iAtgihAxeaMaa mta, idhNp'<JI i. 44$1 St. I:uCie. Blvd.
• Fort Pierce, FL 34946
C➢CfsEAM Stt9iAAd Asa! Lassa• AotAcar i. Tamks llh P:E. cepradust:aa 0 teis dssami t,,a ea, firm is pralFded r�ith➢ai thew, petmttiosisam A �i Roof Trarsa: • Aslka➢rT, Tsmha tlt: P.E.
.�1
STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDTL15
FEBRUARY 17, 2017 DAMAGED OR MISSING CHORD SPLICE PLATES
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TOTAL NUMBER
OF NAILS EACH
SIDE OF BREAK *
X
(INCHES)
MAXIMUM FORCE (LBS) 15% LOAD DURATION
SP
OF
SPF
HF
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
20
30
24•
1706
2559
1561
2342
1320
1980
1352
2028
26
39
30•
2194
3291
2007
3011
1697
2546
173E
2608
32
48
36•
2681
4022
2454
3681
2074
3111
2125
3187
38
57
42•
3169
4754
2900
4350
2451
3677
2511
3767
44
66
48•
3657
5485
3346
5019
21129
4243
2898
4347
+� DIVIDE EQUALLY FRONT AND BACK
ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF
THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE
ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (131' DIA. X 3').
STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' D.C. SPACING IN
THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE.
THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS)
THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C
G C 2
BREAK
i
C�,lel
3
'• lOd NAILS NEAR SIDE �1r1
+ 10d NAILS FAR SIDE y'
6' MIN
X' MIN
TRUSS CONFIGURATION
AND BREAK LOCATIONS
FOR ILLUSTRATIONS ONLY
THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO
THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT
AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE).
DO NOT USE REPAIR FOR JOINT SPLICES
NOTES:
1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR
DOES INOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE
TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN
THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF
SUPPORTING THE LOADS INDICATED.
2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR
AND HELD IN PLACE DURING APPLICATION OF REPAIR.
3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID
UNUSUAL SPLITTING OF THE WOOD.
4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID
LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
5. THIS,REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY.
G. THIS'REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS.
FEBRUARY 17, 2017
SCAB APPLIED OVERHANGS
STDT�L16
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TRUSS CRITERIA:
LOADING: 40-10-0-10
DURATION FACTOR: 115
SPACING: 24' O.C.
TOP CHORD: 2X4 OR 2X6
PITCH: 4/12 - 12/12
HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL
END BEARING CONDITION
NOTES:
1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS
WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148' DIA. X 3') SPACED G' O.C.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO
AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
2X SC
NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED
WHEN OVERHANG HAS BEEN BROKEN OFF.
IMPORTANT
THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS. LESS THAN 400 SPACED 24'
O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD
LOADS NOT EXCEEDING 50 PSF.
TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.
REFER TO INDIVIDUAL TRUSS DESIGN
FOR PLATE SIZES AND LUMBER GRADES