HomeMy WebLinkAboutPLOT PLAN - 9-7-18PROJECT DESCII P''TION: 09x290 SOLARWORLD SW 290 MODULES ROOF MOUNT SOLAR PHOTOVOLTAIC MODULES V I V I LIYI VILL. L.V 1 Avv VV V I V ARRAY AREA #1: 162.36 SQ FT. EQUIPMENT SUMMARY 09 SOLARWORLD SW 290 MODULES 01 SB 3.0-1SP-US-40 INVERTER SHEETINDEX A-00 PLOT PLAN & VICINITY MAP A-01 SYMBOLS & SYSTEM DESCRIPTION -S-01- -ROOF PLAN-&-MODUL-ES S-02 STRUCTURAL ATTACHMENT DETAILS E-01 ELECTRICAL LINE DIAGRAM E-02 WIRING CALCULATIONS E-03 SYSTEM LABELING GOVEi: ;3 CODES: FLORI''.;- z�_'�ECTRIC CODE, 6TH EDITION 2017 EDITION (FEC) FLORIDA RESIDENTIAL CODE, 6TH EDITION 2017 (FRC) FLORIDA PLUMBING CODE, 6TH EDITION 2017 (FPC) -FLORIDA BUILDING -CODE 6TH-EDITION 2017 EDITION-(FBC-) FLORIDA MECHANICAL CODE, 6TH EDITION 2017 (FMC) NEC 2014 CODE BOOK NOTE TO INSTALLER: FIELD ADJUSTMENTS CAN BE MADE TO THE LAYOUT OF THE ARRAY DS-01 DATA SHEET DS-02 DATA SHEET DS-03 DATA SHEET (E) MAIN DISTRIBUTION PANEL DS-04 DATA SHEET 0 MO `s. 00 I 1-STI �p I HOL I 19'-311 51 AEI = E 0 r 126'-0" ROOF #1 (09) SOLARWORLD SW-290 MODULES SATE 1 PLOT PLAN WITH ROOF PLAN A-00 SCALE: 1/16" = 11-0" a ST.LUCIE COUNTY PLAN REVIEW DATE• ELEe j DATE PLUMB: DATE: MECH: 126'-1 " DATE: 7-, _U RY I a0 D 3E �J EXISTING DRIVEWAY I 29'-11" COPYRIGHTED BY CA ENGINEERING SERVIC CAE. } � f r— NRUdECT SITE A,� % �l 2 HOUSE PHOTO A-00 SCALE: NTS 7J �0 I PROJECT Sift 10 6tt f Fort Pierce -South - V`Jfiit� r r l: t. g�E SHEET SIZE ANSI B 11" X 17" 3 VICINITY MAP SHEET NUMBER ESQ LLC A-00 SCALE: NTS A-00 Castillo Engineering kia DESIGNED TO PERWTI' CASTILLO ENGINEERING SERVICES, LLC COA F 28345 2925 W. STATE ROAD 434, SURE 111 LONGWOOD. FL 32779 TEL:(407)474-9181 ERMOCRATES E. CASTILLO-FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJEC,,D VELOPER� rL� Y P .0 7 ,2010 ���C• % �. -N 25 90 TE -� DNA L U 04 W v � J U) U_ Of QU Z (L W_ W O q E-L Z 20 O LL SHEET NAME PLOT PLAN & VICINITY MAP Symbols: Abbreviations: Sheet where Section .............. x section is located x-xx AC Alternating Current Detail ID Letter APPROX Approximate Elevation ........... *��section Sheet where System Description is located AWG American Wire Gauge —Detail_]D-Letter --CBCo-tY►biner Box - Thfs-system-is-a grid=tied—PV system, —with PV generation consisting of-9 &OLA-RWORLD Detail ................ x Txx Sheetwhere SW 290 MODULES (29OW) MODULES PV modules with a combined STC rated do section is located DC Direct Current output power of 2,610 W. The modules are connected into 01 SB 3.0-1 SP-US-40 Detail ................ x DCD Direct Current Disconnect OD etail EAreail ID Letter a to be enlarged INVERTER. The inverter has electronic maximum power point tracking to maximize (Enlarged Plan) x'xx where DISC Disconnect energy captured by the PV modules. The inverter also has an internal ground fault section is located (E) Existing detection and interruption device that is set to disconnect the array in the event that a Keyed Notes.......... O Keyed note designation ground fault that exceeds one ampere should occur. The inverter has DC and AC on applicable sheet EL Elevation disconnect integrated system and labels are provided as required by the National Ground Terminal..... EQ Equal Electric Code JB Junction Box PV Modules ....... 0>� Grounding Point/rod.... Jr MCB Main Combiner Box m Junction Point of O MFR Manufacturer Inverter Box Utility gmm Solar Panel ......... or R—m, odulewith Source MIN Minimum Centralized AC to Connectioncrcuit number DC Inverter Utility Meter MISC Miscellaneous Combiner Box .......... Cg (N) New OCPD OverCurrent Protection Device Figure 1: PV System Block Diagram DC Disconnect .......... DCD POCC Point Of Common Coupling When the sun is shining, power from the PV array is fed into the inverter, where Main Distribution FMP Pv Photovoltaic it is converted from DC to AC. The inverter output is then used to contribute to the Panel ...................... SF Squarefoot/feet power requirements of the occupancy. If PV power meets the requirements of the Fuse ... STC Standard Test Conditions loads of the occupancy, any remaining PV power is sold back to the utility. When utility -�— power is available, but PV power is not available, building loads are supplied by the TBD To Be Determined utility. OvercurrentBreaker.. _ Tryp Typical The inverter meets the requirements of IEEE 1547 and UL 1741. This means that if it detects a loss of utility power, it will automatically disconnect from the utility. VIF Verify In Field When utility voltage is restored the inverter automatically reconnects to the utility grid Inverter .................... - i ti WP Weather Proof after verifying utility voltage and frequency stability. Transformer ............. On a day with average Florida sunshine, this system outputs 11.10 kWh per day on site. Automatic ............... ATs Transfer Switch COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC Castillo Engineering DESIGNED TO PERMITn CASTILLO ENGINEERING SERVICES, LLC COA a 28.345 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL 32779 TE' (4M 474.9181 ERMOCRATES E CASTILLO - FL PE S2590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER EF 0.7 2010 • �1 E/jrS. �� N 52590 T!_ fi 19 W U C%j LIJ � J V- QU Z o' �- W O �a Z "' w o O SHEET NAME SYMBOLS & SYSTEM DESCRIPTION SHEET SIZE ANSI B 11" X 17' SHEET NUMBER A-01 MODULE TYPE, DIMENSI1, <1 &WEIGHT NUMBER OF MODULES = 09 MODULES MODULE TYPE = SOLARWORLD SW-290 MODULES WEIGHT = 39.7 LBS / 18 KG. UNIT WEIGHT OF ARRAY = 2.20 PSF 3/4" PVC CONDUIT RUN (N) RAPID SHUTDOWN BOX _ "IMU4 sr (E) MAIN DISTRIBUTION PANEL (N) AC DISCONNECT (IF REQUIRED) (N) PV METER (IF REQUIRED) (N) SB 3.0-1SP-US-40 INVERTER 1 ROOF PLAN & MODULES S71 SCALE: 1/8" =1'-0" INV 00 ARRAY #1 61'-611 TILT - 22.6P ROOF #1 AZIM. - 180° (09) SOLARWORLD SW-290 MODULES _ (16) PV ROOF ATTACHMENT @ 48" O.C. MAX (N) IRONRIDGE XR 10 RAIL (TYP.) ARRAY & ROOF AREA CALC'S (ROOF #1) ARRAY AREA=162.36 SQ. FT. WC ROOFFACE AREA = 645_89_SQ_FT.—ri 162.36 / 645.89 = 25.14% OF ROOF FACE AREA COVERED BY ARRAY DESCRIPTION (ROOF #1) ROOF TYPE - ASPHALT SHINGLE ROOF ROOF TILT - 22.6° ROOF AZIMUTH - 180' RAFTER SIZE - 2"x4" @ 24" O.C. GENERAL INSTALLATION PLAN NOTES: 1) DRAWINGS SHOWN MAY NOT REFLECT FIELD CONDITIONS. -CONTRACTOR TO FIELD VERIFY CONDITIONS PRIOR TO INSTALLATION. 2) CONTRACTOR MAY LOCATE PV MODULES TO DIFFERENT LOCATION THAN SHOWN, BUT SHALL NOT PLACE PV MODULES IN WIND ZONE 3. UNLESS NOTED OTHERWISE IN NOTE 3 BELOW. 3) ROOF ATTACHMENTS TO SYP RAFTERS SHALL BE INSTALLED AS SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND e WIND ZONE 1: 4'-0" O.C. WIND ZONE 2: 2'-0" O.C. WIND ZONE 3: 2'-0" O.C. SEE SHEET S-02 FOR SUPPORTING CALCULATIONS. 4) EXISTING RESIDENTIAL BUILDING IS ASSUMED TO BE A ASPHALT SHINGLE ROOF FINISH WITH MEAN ROOF HEIGHT LESS THAN 30 FT AND SYP 2X4 WOOD ROOF RAFTERS SPACED 24" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEM RETROFIT IS ASSUMED TO BE BETWEEN 7 TO 27 DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND IN FIELD CONDITIONS. I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3. BUILDING a STRUCTURE WILL SAFELY ACCOMMODATE CALCULATION WIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS. ' s 39.40" 11 _n � O co SOLARWORLD - H 41-011 ,747 SW-290 MODULES -70 LEGEND IRSRAPID SHUTDOWN WIND ZONE 3 (TYP.) -INVERTER % WIND ZONE 1 (TYP.) oc - INTEGRATED DC DISCONNECT WIND ZONE 2 (TYP.) PM _ PRODUCTION METER / WIND ZONE 3 (TYP.) MOP - MAIN DISTRIBUTION PANEL 41-011 O ❑ -VENT, ATTIC FAN (ROOF OBSTRUCTION) O - PV ROOF ATTACHMENT --- - - -RAFTERS COPYRIGHTED BY CASTILLO ----- -CONDUIT ENGINEERING SERVICES, LLC Castillo Engineering DESIGNED TO PERMITS CASTILLO ENGINEERING SERVICES, LLC COA#2894S 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD. FL 32779 TEL: (407) 474-9181 ERMOCRATES E. CASTILLO -FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER SEP 07,2o18 I 25 9 to- AT F �� ,' .o �NA.L.. �o0fillfl U N Z co Lu � J U- QU z a. �- w O �a z o O SHEET NAME ROOF PLAN & MODULES SHEET SIZE ANSI B 11" X 17" SHEETNUMBER S-01 SOLAR MODULE SEE (2/S-02) FOR ENLARGED VIEW 7 I A=Af%L1KACAIT 11ICTA11 (E) ASPHALT SHINGLE ROOF (E) 2" X 4" RAFTERS @ 24" O.C. AP ) IRONRIDGE XR10 RAIL ONRIDGE FLASH FOOT2 (E) ROOF SHEATHING (E) 2" X 4" RAFTERS @ 24" O.C. 5/16"x3" SS LAG BOLT WITH MIN ZY2" THREAD EMBEDMENT, SEALED PENETRATION 'HTED BY CASTILLO RING SERVICES, LLC 130 115 120 130 IL 115 •- _ b C— o1m - San 4�•'" tson .G ).�� -g( f ,d, 140 t ,;' -1 158 1 Values ore uRtraato design 3 secold gust — 1 r 179 wltd speeds an files per hour tt (10.) abovi srouad for'Expesure'C tow ji 2 ttnea interpo]atian betweon contours 160 r 1s Peratted .s � 3 � tslanaand coastal areas outside the cast Contour s"11 use theilast wind �3Peed 179 m eers x• <enteu of the_coastal Brea , - _ � 4. "� pountefimus terrain„_gorges ticeen .a _ pro—ncories:; and special winE„regions , ahnil be exar�ned fx umisusl'wind Bondi 180 liars F J 5.. tdad speeds -.pond, to apprbxi-toly _ i` •a�71t probability of ex_ceedarEe:.in ¢0 years, r!-, a,_,(agnwlEaceedaxteProbabillty '.'o:001a3 r� '� HRI- ]00 years) " FIGURE 1609.319) ` �: v "� ULTIMATE DESIGN WIND SPEEDS V(KT `FOR RISK CA7EGGRY 11'®UILDINOVAND OTHER STRUC7URks Wind Speed UIt (mph) 17D Risk Category II Wind Speed ASD (mph) 14t3 Exposure Category Mean Roof Height (ft) OF275M Roof Slope (degrees) Module Area (sq ft) 111120 KA 1 Height Adjustment Factor,A 1 RoofZone Pnet (30) 1 18.5 -31.4 2 18.5 -51.7 3 18.5 P net=[MI-aP (net(30)) Roof Zone Pnet 1 18.5 1IMIIII 2 18:5 51.7 3 18.5 11MIIII 22.6 Maximum Uplift per *fastener Wind Zone 1 345.4 Per American Wood Council - NDS Max Withdraw Load for 5/16" LAG with 25' 476 Embedment *Roof attachements w 2 rails at; . 4 _ft O/C Maximum Uplift per *fastener Wind Zone 2 284.4 Per American Wood Council - NDS Max Withdraw Load for 5/16" LAG with 2.5" 476 Embedment *Roof attachements w 2 tails -at: 2 ft O/C Maximum Uplift per *fastener Wind Zone 3 427.4 Per American Wood Council - NDS Max Withdraw Load for 5/16" LAG with 2.5" 476 Embedment *Roof attachements w 2 rails at: 2 ft O/C Castillo fr ngineering CASTILLO ENGINEERING SERVICES, LLC COA A 28345 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL32779 TEL (407) 474.9181 ERMOCRATES E CASTILLO - FL PE 52590 REVISIONS DESCRIPTION I DATE RD PROJECT DEVELOPER SEP 0 ,2018 ��ettlllle��ii i "Y'®�� �81/1l111t W U N Z 00 W � U) ,J LL QU Z a W o r— W � a Z W O SHEET NAME STRUCTURAL ATTACHMENT SHEET SIZE ANSI B 11" X 17" SHEET NUMBER S-02 I j— — — — I I I I I I I I rl I I I I I I I I I (1) #12 AWG USE-2/PV WIRE + Red (1) #12 AWG USE-2/PV WIRE - Black EGC #10 BARE CU IN FREE AIR (09) SOLARWORLD SW 290 MODULES TOTAL (01) STRING OF 09 MODULES CONNECTED TO MPPT #1 PV MODULE GROUNDING SYSTEM RAPID SHUTDOWN CONTROLLER MOUNTED OUTSIDE IN ACCESSIBLE LOCATION NEXT TO ELECTRICAL METER OR OPTIONAL PV AC DISCONNECT ----------------------------- ----------------- (N) SMA RAPID (4) #18 AWG THWN-2 IN 1/2" PVC CONDUIT RUN NIKOMY 11110)1 (1) #10 AWG THWN-2 + RED (1) #10 AWG THWN-2 - BLACK EGC #10 AWG THWN-2 IN 3/4" PVC OR EMT CONDUIT RUN USE METAL RACEWAYS FOR ANY DC CIRCUITS ENTERING BUILDING PRIOR TO INVERTER DC DISCONNECTING MEANS PER 690.31 1 ELECTRICAL LINE DIAGRAM E-01 SCALE: NTS (N) INVERTER: #1 SB 3.0-1SP-US-40 OUTPUT: 240 VAC, 12.5A 96.5% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT �� INTERCONNECTION 120% RULE - CEC 705.12(13)(2)(3)(b) UTILITY FEED + SOLAR BACKFEED 200.0 A + 20A = 220A BUSS RATING x 120% 200.0 A x 120% = 240A (N) AC DISCONNECT: (N) PV METER 240V, 60AMP NON FUSED (SMUD/GRIDLEY ONLY) NEMA 3R, UL LISTED (IF REQUIRED) (IF REQUIRED) L1 L1 L1 L1 ° ° ° L2 L2 • J%— L2 N °�° — N N N ---AGI r I I ' (3) #10 AWG THWN-2 (1) #10 AWG THWN-2 GND IN 1/2" PVC OR EMT CONDUIT RUN PROVIDE GROUNDING ELECTRODE CONDUCTOR FROM THE INVERTER TO AN EXISTING SERVICE GROUNDING ELECTRODE PER 690.47(B) 1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC 2014, AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, AS APPLICABLE. 2. RAPID SHUT DOWN BOX IS A COMBINER BOX WITH GROUND FAULT PROTECTION AS PER NEC 690.5, ARC FAULT PROTECTION AS PER NEC 690.11, RAPID SHUT DOWN PROTECTION AS PER NEC 690.12, AND MANUAL DISCONNECT AS PER NEC - 690.17. L TO UTILITY GRID BI-DIRECTIONAL (91 UTILITY METER 1-PHASE, 240V (E) MAIN DISTRIBUTION PANEL, 200A RATED, 240V. (E) MAIN BREAKER 240V, 20OAl2P EXISTING GROUNDING ELECTRODE SYSTEM COPYRIGHTED BY CASTILLO ENGINEERING SERVICES. LLC Castillo Engineering DESIGNED TO PERMIT. CASTILLO ENGINEERING SERVICES, LLC COA#28345 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL32779 TEL•(407)474.9181 ERMOCRATES E CASTILLO - FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER SEP 0 7 2010 a� S a re �'� • 1 ENsf<<O 0 590 SAT f�'.• OR BB��p�Plllltl\\\\ Lu U N z 0) W dt 0 J V- QU z aw- W O u')a Z L0 � O 0 SHEET NAME ELECTRICAL LINE DIAGRAM SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-01 DC CONDUCTOR AMPAa , -1rY CALCULATIONS: ARRAY TO RAPID SHUTDOWN BOX (INV #1): EXPECTED WIRE TEMP (In Celsius 33' TEMP. CORRECTION PER TABLE (310.16) 0.94 NO. OF CURRENT CARRYING CONDUCTORS 2 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 1.0 CIRCUIT CONDUCTOR SIZE 12 AWG CIRCUIT CONDUCTOR AMPACITY 25A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X 1.25 X Isc 15.58A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 23.5A TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (15.58A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM RAPID SHUTDOWN BOX TO INVERTER (INV #1): AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c) +� EXPECTED WIRE TEMP (In Celsius) 3T+2Z = 5T TEMP. CORRECTION PER TABLE (310.16) 0.67 NO. OF CURRENT CARRYING CONDUCTORS 2 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) 1.0 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 35A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 1.25 X 1.25 X Isc 15.58A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP. CORRECTION PER TABLE (310.16) X 23.45A CONDUIT FILL CORRECTION PER NEC 310.15(8)(2)(8) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (15.58A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: -No.-OF-INVERTER EXPECTED WIRE TEMP (In Celsius) 33• TEMP. CORRECTION PER TABLE (310.16) 0.94 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC 310.15(8)(2)(a) 1 #1 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 35A INVERTER OUTPUT CONDUCTORS REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 15.63A 1.25 X MAX INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 32 9A TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (15.63A) otherwise less the entry for circuit conductor size and ampacity ELECTRICAL NOTES 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. 10. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 11. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. 12. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 13. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.8 (D). 14. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). DC PHOTOVOLTAIC POWER SOURCE TO BE INSTALLED AT-INVERTER-rPER-WG-690.53 & 690.54 OPERATING CURRENT 11.66A OPERATING VOLTAGE 282.6V SHORT CIRCUIT CURRENT 9.97A MAXIMUM SYSTEM VOLTAGE 430.92V SOLAR MODULE SPECIFICATIONS MANUFACTURER_ _ _ __ SOLARWORLD- MODEL # SW 290 PMAX 290W VMP 31AV IMP 9.33A VOC 39.9V ISC 9.97A MODULE DIMENSION 65.95"L x 39.4"W x 1.26"D (In Inch) INVERTER #1 SPECIFICATIONS MANUFACTURER SUNNY BOY INVERTER MODEL # SB 3.0-1 SP-US40 NOMINAL AC POWER 3.0 KW NOMINAL OUTPUT VOLTAGE 240V NOMINAL OUTPUT CURRENT 12.5A PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 0.80 4-6 0.70 7-9 0.50 10-20 COPYRIGHTED BY CASTILLO ENGINEERING SERVICES. LLC Castillo Engineering DESIGNED TO PERMIT- CASTILLO ENGINEERING SERVICES, LLC CQA028345 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL 32779 TEL (407) 474-9181 ERMOCRATES E. CASTILLO - FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER SEP .0 7 T201 tb fe .� •C E/ji 0 N 590 S Tq E F ENS; .. U N Z 00 W I;t J 0LU QU Z alz r W z `� 2 O O LL SHEET NAME WIRING CALCULATIONS SHEET SIZE ANSI B 11 EE X 17EE SHEET NUMBER E-02 ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: NEC 690.35(F)) [Po be used when inverter is ungrounded] ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: NEC 690.35(F)) [To be used when inverter is ungrounded] ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 690.17(E), CB ADHESIVE FASTENED SIGNS: • THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. • WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535A [NEC 110.21(B) FIELD MARKING]. • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.31 LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.54) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(4)) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC690.15, 690.13(B)) INVERTER #1 LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: NEC690.53) LABEL LOCATION: AC DISCONNECT, DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC690.56(C)) POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT:® METER AND MAIN DISTRIBUTION PANEL AC DISCONNECT PV METER - --INVERTER— NINEb MARKING CONTENT AND FORMAT • RED BACKGROUND e • WHITE LETTERING - • MINIMUM 3/8" LETTER HEIGHT • ALL CAPITAL LETTERS • ARIAL OR SIMILAR FONT, NON -BOLD • REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT) COPYRIGHTED BY CASTILLO ENGINEERING SERVICES. LLC Castillo Engineering -D£ $tBNfD-Y'O-}'EA-A�TTr -- CASTILLO ENGINEERING SERVICES, LLC Can # 28345 2925 W. STATE ROAD 434, SURE 111 LONGWOOD, FL32T79 TEL• (407) 4748187 ERMOCRATES E.CASTILLO - FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER SEP 0 2018 ttttllll 6� � O N F'•. S2590 S q .T OF N ell /VA L �� Illltlttt w U N z 0) w Nt 0 J Il LU QU z aLU �w O L0a zto = O O w SHEET NAME SYSTEM LABELING SHEET SIZE ANSI B 11" X 17" SHEET NUMBER E-03 TUV Power controlled: I Lowest measuring tolerance in industry Every component is tested to meet 3 times IEC requirements J ® Designed to withstand heavy accumulations of snow and ice Sunmodule Plus: Positive performance tolerance •r 'J 2�7 �+7 25-year linear performance warranty and 10 year product warranty J " Glass with anti -reflective coating ar J World -class quality Fully -automated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites worldwide. SolarWorld Plus -Sorting Plus -Sorting guarantees highest system efficiency. SolarWorld only delivers modules that have greater than or equal to the nameplate rated power. 25-year linear performance guarantee and extension of product warrantyto 10 years SolarWorld guarantees a maximum performance digression of 0.7% p.a. in the course of25years, a significant added value compared tothetwo-phase warranties common in the industry, along with our industry -first 10 year product warranty. - Solar cells manufactured in U.S.A. or Germany. Modules assembled in U.S.A. 'in accordance with the applicable SolarWorld Limited Warranty at purchase. www.solarworld.com/warranty solarworld.com o..0.. n:c 6U11 •.11,8sled, nc 6Tr30 c. V •Blowin salts rcsisNnc<.IEC 60068-2-6E D E •Ammanla rcYlLanee.IFC6m6 I``1 •San mill lonosion.IEC 61i01 . Pa1ladlslmPalltan \■ c us UL 1703 ��=- •Pa uonae Ln • ,111• C E © Horn :lio. GS MADE .�� OF US & IMPORTED PARTS' Sunmodule%Plus I Jilail, SGURWORLD SW 285-300 MONO (5-busbar) • . - ----PERfORMANGEUNDER-STANDARDTESTCONDITIONS {STC)' - - -- SW 285 SW 290 SW 295 SW 300 Maximum power P,,,,, 285 Wp 290 Wp 295 Wp 300 Wp Open circuit voltage V., 39.7 V 39.9 V 40.0 V 40.1 V Maximum power point voltage VmPp 31.3 V 31.4 V 31.5 V 31.6 V Short circuit current IK 9.84 A 9.97 A 10.10 A 10.23 A Maximum power point current Imp 9.20 A 9.33 A 9.45 A 9.57 A Moduleefflclency R. 17.00 % 17.30 % 17.59 % 17.89 'STC: 1000W/m� 25'C•AM 1.5 PERFORMANCE AT 800 W/Mt, NOCT, AM 1.5 SW 285 SW 290 SW 295 SW 300• Maximumpower P,,,a„ 213.1 Wp 217.1 Wp 220.5Wp 224.1 Wp Open circuit voltage va 36.4 V 36.6 V 36.7 V 36.9 V Maximum power point voltage Vm% 28.7 V 28.B V 28.9 V 31.1 V Short circuit current Iu 7.96 A 8.06 A 8.17 A 8.27 A Maximum power point current ImpP 7.43A 7.54A 7.64A 7.75A Minor reduction in efficiency under partial load conditions at 25 °C: at 200 W/mz, 100%ofthe STC efficiency (1000 Vail is achieved. *Preliminary val u es. subject to change. COMPONENT MATERIALS l000 w/m= Cells per module 60 Front Low -iron temp ered glass Boo W/ma with ARC (EN 12150) 600 W/m ' 5•bsbar Celltype MonocrystuSbar Frame Clear anodized aluminum 400 W/mr 6.17inx6.17in Cell dimensions (156.75 x 15635 mm) Weight 39.7lbs (18.0 kg) 20ow/mr THERMAL CHARACTERISTICS ADDITIONALDATA 100 W/ma NOCT 46 •C Powersorting -0 Wp/+5 Wp ModulewltageM °` TO. 0.04 % / •C PBox IP65 378 (961) TC � -0.30 % /'C PV wire per UL4703 Connector with H4/UTX connectors a.20 0o (106.65) Operating temp -40 to +85 •C Modulefire performance (U L 1703) Type I a><� 7.12 0026(6.6) (180.85) PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION 00.35(9) o Maximum system voltage SC II/NEC 1000 V Maximum reverse current 25 A Number ofbypass diodes 3 Design loads' Two rail system 113 psf downward, 64 psf upward m {I n1 Design loads' Three rail system 178 psf downward, 64 psf upward Design loads* Edgemounting 178p5fdownward,41psfupward 'Please refer to the Sunmodule installation instructions for the details associated with these load cases. adT OA • Compatible with both "Top -Down' and "Bottom' mounting methods 11.32 n!fg • LGrounding Locations: (2szso) of;ll -4 locations along the length of the module in the extended flange. �-- 39.4 (1001) 1.30 (33) .11_ II All units provided are imperial. 51 units provided in parentheses. SolarWorld AC reserves the right to make specification changes without notice. SW-01-751OUS 160324 Castillo Engineering GC1 DESIGNED TO orn MrTn CASTILLO ENGINEERING SERVICES, LLC COAS2e34S 2925 W. STATE ROAD 434, SUITE III LONGWOOD, FL 32779 TEL (407) 474-9181 ERMOCRATES E CAS71LLO-FL PE S2590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER SEP .0 7.2010 Si Ifed eal /V 5 F'•. 90 ST T NAME UF s Z 00 W d ''^�^ 0 J V! U- aC) Z a W LU O LLO Z o O LL SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-01 A SUININY BOY Value-Added;lmprovements Reduced Labor. • Superior integration with SMA's New Installation Assistant with MLPE Power+ Solution direct access via smartphone • World's first Secure Power Supply' minimizes time in the field now offers up to 2,000 W Integrated disconnect simplifies • Full grid management capabilities equipment stocking and speeds ensure a ufilitycompliont solution installation for any market Unmatched Flexibility • SMA's proprietary OptiTrael Global Peak technology mitigates shade with ease • Multiple independent MPPTs accommodate hundreds of stringing possibilities Trouble -Free Servicing • Two-part enclosure concept allows foe simple, expedited servicing • Enhanced AFCI technology reduces false tripping while improving sensitivity in real arcs SUNNY BOY 3.o-us / 3.8-US / 5.0-US / 6.0-US / 7.0-US / 7.7-US Reduce costs across your entire residential business model The residential PV market is changing rapidly. Your bottom line matters more than ever -so we've designed a superior residential solution to help you decrease costs at every stage of your business operations. The Sunny Boy 3.0-US/3.8- US/5.0-US/6.0-US/7.0-US/7.7-US join the SMA lineup of field -proven solar. technology backed by the world's #1 service team, along with a wealth of improvements. Simple design, improved stocking and ordering, value -driven sales support and streamlined installation are just some of the ways that SMA helps your business operate more efficiently. And, Sunny Boy's superior integration with the innovative Power+ Solution means installers have even more flexibility in addressing their toughest challenges. www.SMA-America.com Technical data bunny Boy 3.Od15 Sunny Boy 3.8-US Sunny Boy 5.0-US 208 V 240 Y 208 V 240 Y 208 V 240 Y Input(DCI Max. usable DC power 3100 W 3100 W 3450 W 4000 W 5150 W 5150 W Max, DC voltage 600 V Rated MPP voltage range 155 - 480'V 195 -480 V 220 - 480 V MPPT operating voltage range 100 - 550 V Min. DC voltage / start voltage 100 V / 125 V Max:.pperating input current per MPPT - 10 A Max. short circuit current per MPPT 18 A N !nbecof.MPPT_tracker./-stnng.pecMP.PTtracker ----2/1 - -`- .. 3-/-1 --- Output (AC) AC nominal power 3000 W 3600 W 3330 W 3800 W S000 W 5000 W Max, AC apparent power . 3000 VA 3600 VA 3330 VA 3800 VA 5000 VA 5000 VA Nominal voltage / adjustable 208 V / • 246 V / • W8 V / • 240 V / • 208 V / • 240 V% e- AC voltage range 183 - 229 V 211, - 264 V. 183' - 229 V 211 - 264 V 183 - 229 V 211 - 264 V AC grid frequency 60 Hz / 50 Hz Max. output current 14.5 A 12.5 A 16.6 A 16,0 A 24.0 A 24.0 A , Power Factor (cos rp)- ' Output, phases /line connections - 1/2 ". Harmonics .2 4 % .... Efficiency Max efficiency 97.2 % 97.6 % 97.2 % 97.5 % 97.2 % 97:5 CEC efficiency 96 % 96.5 % 06.5 % 96.5 % 96.5 % 97 % Protection devices DC disconnect device • DGreverse polarity protection Ground Fault monitoring / Grid monitoring • AC. short circuit protection., Allpole sensitive residual current monitoring unit (RCMU), ' _ • - , Arc fault circuit interrupter [AFCI) • Protection clas§ / overvoltage category _ .. - - I / IV _ General data Dimensions (W / H / D)Jn mm (in) 535 x 730 x 198 (21.1 'x 28.5 x 7.8) Packaging dimensions (W / H / D) in min (in) 600 x 800 x 300.(23.6 x 31.5 x 11.8) Weight / packaging weight - 26 kg (57161 / 30 kg (66161 - Operafingtemperaturerange - - .- 25•C..+60•C Noise emission (typical) 39 dB(A) Internal power consumption atnight. - _ - - 5,w Topology - - - Trgnsformedess Coolingconcept convection Features Ethernet ports Secure Power Supply.. • Display (2 x 16 choractersl- - - - - • - - - - _ - - WLAN Sensor module / External WLAN antenna. 6/0, Warrant); 10 / 15 / 20 years - •/O/O - Certificates and approvals - UL 1741, UL 1998„ UL 1699B, IEEE1547, FCC Port 15 (Gass A & B), CAN/CSAV22.2 107.1-1 • Standard Featuros O Optional features - Not available Data at nominal conditions NOTE: US.invertets ship with gray lids., • Not functional with Power+ Solution- Typedesignation SB3.0-1SP-US•40 S113-8-1SP-US-40, SB5.01SRU540 Accessories -Sensor module ?� Ed-.1 WIAN antenna / \ SMA RooBop MMSEN-U540 EXTANT-US40 , Commu :.P n IGr V 1 ! ROOKOMMIOrFI-us ,. __-------------- - -----------: .-•---------------: EfftaencycumSUNNYBOY6.0-1SP-US-40 i- ------------------------------- 98 - _-__,.. .. i .• 94 Ti 92 F i 90 - F._ .....-., ._-,.._-__. _ __-_ 88.E-...._.._._.. t •a ------- dPrv,.-22ov1 _ Fm tV„-375Y1 szP 86 _.._ _ -.. E..(V„-4BOVI _M -0.0 0.2 OA 0.6 0.8 1.0 Output pourer / Rated power Castillo Engineering DESIGNED TO P AM1T• CASTILLO ENGINEERING SERVICES, LLC COA # 28345 2925 W. STATE ROAD 434, SUITE 111 LONGWOOD, FL32779 TEL; (407) 474-9181 ERMOCRATES E CASTILLO - FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER SEP V 7 ,2010 a0\\\\\111111 Q e, oI ♦ Sign egl� . � 0 2590 it ST T �s�' � o R I P..•� � '���jflt ill\\\, W CN W d � J rA�r VJ QU Z a W W O U') a. �W Z = 0 0 LL SHEET NAME DATA SHEET SHEET SIZE ANSI B 11rr X 17° SHEET NUMBER DS-02 N RI DGE Built for solar's toughest roofs. Flush Mount System IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested All components evaluated for superior structural performance. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. PE Certified Pre -stamped engineering letters available in most states. Design Assistant Online software makes it simple to create, share, and price projects. 20-Year Warranty Twice the protection offered by competitors. XR10 Rail Al A low -profile mounting rail for regions with light snow. • 6' spanning capability • Moderate load capability • Clear & black anod. finish --Aitachrrtents- FlashFoot f- f Anchor, flash, and mount with all -in -one attachments. • Ships with all hardware • IBC & IRC compliant • Certified with XR Rails Clamps & Grounding End Clamps XR100 Rail The ultimate residential solar mounting rail. • 8'spanning capability • Heavy load capability • Clear & black anod. finish Slotted L-Feet Drop -in design for rapid rail attachment. • High -friction serrated face • Heavy-duty profile shape • Clear & black anod. finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12' spanning capability • Extreme load capability • Clear anodized finish Standoffs Raise flush or tilted systems to various heights. • Works with vent flashing • Ships pre -assembled • 4" and 7" Lengths Internal Splices All rails use internal splices for seamless connections. • Self -tapping screws • Varying versions for rails • Grounding Straps offered Tilt Legs Tilt assembly to desired angle, up to 45 degrees. • Attaches directly to rail • Ships with all hardware • Fixed and adjustable Grounding Mid Clamps (E) T Bolt Grounding Lugs (j) Accessories impt LIS BMW , LI& Slide in clamps and secure Attach and ground modules Ground system using the Provide a finished and modules at ends of rails. in the middle of the rail. rail's top slot. organized look for rails. • Mill finish & black anod. - Parallel bonding T bolt Easy top -slot mounting • Snap -in Wire Clips • Sizes from 1.22" to 2.3" • Reusable up to 10 times Eliminates pre -drilling • Perfected End Caps • Optional Under Clamps • Mill & black stainless Swivels in any direction • UV -protected polymer Free Resources Design Assistant A � NABCEP Certified Training Go from rough layout to fully ► Earn free continuing education credits, engineered system. For free. A A, while learning more about our systems. Go to IronRidge.com/rm ♦ Go to IronRidge.com/training Castillo Engineering 1t - CASTILLO ENGINEERING SERVICES, LLC COAB2M45 2925 W. STATE ROAD 434. SUITE 111 LONGWOOD, FL 32779 TEL (407) 474-9181 ERMOCRATES E. CASTILLO - FL PE 52590 REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER SEP 0 7 Sign re with Se�� �foers o C� �� /V� .. C).0 5 0 htO CT IREOF s••.ORIDP•'•��. . NA L W 0 J 0) U_ � QU Z aW W Z IX = O O L` SHEET NAME DATA SHEET SHEET SIZE ANSI B 11" X 17" SHEET NUMBER DS-03