HomeMy WebLinkAboutENERGY EFFICIENCY CODE - 11-15-18FORM R405-2017 v
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
i
EIVEp
Project Name: 3505 Ave K
Builder Name: E & B ELITE SERVICES, INC
Street: 3505 Ave K
Permit Office: St Lucie County
NOV 0 5 2018
City, State, Zip: Fort Pierce , FL , 34947
Permit Number:
Pei
Owner: Karleen Watson
Jurisdiction: 611000
Climate
ent
Zone Lu County
Design Location: FL, ST LUCIE_CO_INTL
County:: St. Lucie (Florida y
1. New construction or existing Addition
9. Wall TYP es 629.3sqft.)Insulation Area
(
a. Concrete Block - Int Insul, Exterior R=4.0 629.33 ftz
2. Single family or multiple family Single-family
b. N/A
R= ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of BedroomkBedrms In Addition) 1(1)
1
d. NIA
10. Ceiling Types (776.0 sqft.)
R=
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 776.00 ftz
6. Conditioned floor area above grade (ftz) 776
b. N/A
= ftz
�R17
tfftz
Conditioned floor area below grade (ftz) 0
c. N/A
11. Ducts y,I
;F�,AfA% R ftz
7. Windows( 95.3 sqft.) Description Area
Dbl, U=0.33 77.50 ftz
a. Sup: Attic, Ret: Main, AH: Main-04 6 155.2
Coll,
a. U-Factor:
f
SHGC f SHGC=0.22
b. U-Factor: Dbl, U=0.36 17.78 fta.
12. Cooling systems
Central Unit
kBtu/hr Efficiency
27.6 SEER:16.00
SHGC' SHGC=0.24
c. U-Factor: N/A
SHGC:
13, Heating systems
kBtulhr Efficiency
d. U-Factor: N/A ftz
a. Electric Strip
P Heat
34.0 COPA.00
SHGC:
Area We'ghted Average Overhang Depth: 7.818 ft.
14. Hot water systems- Replacement
equipment
Area Wlghted Average SHGC: 0.224
a. Electric
P� Ca 40 gallons
8. Floor Types (776.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 776.00 ft'
b. Conservation features
b. N/A R= ftz
None
c. NIA R= ftz
15. Credits
Pstat
j Total Proposed Modified Loads: 23.39
�7
PASS
Glass/Floor Area: 0.123 Total Baseline Loads: 24.12
I
I
-
I hereby certify that the plans and specifications covered by
Review of the plans and
t -tilE 5r� ¢
this calculation are in compliance the Florida E�7y
specifications covered by this
AV
�`'' ��' '{�
Code.
calculation indicates compliance
�`��,• ,
a
with the Florida Energy Code.
:,;,r•- _ ,` a�
PREPARED t3Y.
Before construction is completed
DATE: / D
this building will be inspected for
compliance with Section 553.908
I
1 hereby certify that this building, as designed, is in compliance
Florida Statutes.
�0D
with the Florida Energy de.
WE
OWNER/A
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
F� ctj
I
10/22I�01810:56 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4
I
I
FORM R405-201
PROJECT
Title:
3505 Ave K
Bedrooms: 1
Address Type: Street Address
Building Type:
User
Conditioned Area: 776
Lot #
Owner Name:
Karleen Watson
Total Stories: 1
Block/Subdivision:
# of Units: I
1
Worst Case: No
PlatBook:
Builder Name:
E & B ELITE SERVICES, INC Rotate Angle: 0
Street: 3505 Ave K
Permit Office:
St Lucie County
Cross Ventilation:
County: St. Lucie
Jurisdiction: 1
611000
Whole House Fan:
City, State, Zip: Fort Pierce ,
Family Type:
Single-family
FL, 34947
NewlEAsting:
Addition
Comment:
f
i
CLIMATE
Design Temp
Int Design
Temp Heating Design Daily Temp
Design
Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL
FL VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
FNu
Name
Area Volume
Blocks
776 6208
i
SPACES
rNuffbers
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
I
Main
776 6208 No 1
1
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R Value
Area
Tile Wood Carpet
j 1 Slab -On -Grade Edge Insulatio Main 78.8 ft 0
776 ft2
____ 0 0 1
ROOF
Roof Gable Roof
Solar
SA Emitt Emitt Deck Pitch
#
Type
Materials Area Area Color
Absor.
Tested Tested Insul. (deg)
1
Gable or shed
Composition shingles 818 ft2 130 ft2 Medium
0.85
No 0.9 No 0 18.4
ATTIC
I
i #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150
776 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented) Main 30 Blown
776 ft2 0.16 Wood
10/22/201 8 10:56 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405 2017
—
WALLS
Cavity Width Height
Sheathing
Framing Solar
Below
o
1 Adjacent Space
-
-on
Ahsnr
To Wall Tvpi�p
1 E Exterior Concrete Block - Int Insul Main
4 19 4 8
154.7 ftz
0 0.75
0
_
2 S Exterior Concrete Block - Int Insul Main
4 26 8
208.0 ft?
0 0.75
0
_
3 S Exterior Concrete Block - Int Insul Main
4 14 8
112.0 ft2
0 0.75
0
_
— 4 WI Exterior Concrete Block - Int Insul Main
4 19 4 8
154.7 ft2
0 0.75
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
/ Wall
v # Omt ID Frame Panes NFRC
U-Factor SHGC Imp Area
Overhang
Depth Separation
Int Shade
Screening
1 S 2 Vinyl Low-E Double Yes
0.33 0.22 N 31.0 ft2
2 ft0 in 1 ft 0 in
None
None
2 S 3 Vinyl Low-E Double Yes
0.33 0.22 N 31.0 ft2
14 ft0 in 1 ft0 in
None
None
3 1 S 3 Vinyl Low-E Double Yes
0.36 0.24 N 17.8 ft2
14 ft0 in 0 ft 6 in
None
None
4 1 W 4 Vinyl Low-E Double Yes
0.33 0.22 N 15.5 ft2
Oft 0 in Oft0 in
None
None
I
INFILTRATION
# 7SScoppl Method SLA
CFM 50 ELA EgLA
ACH ACH 50
1 Wholehouse Proposed ACH(50) .000254
517.3 28.4 53.41
.1906
5
HEATING SYSTEM
System Type Subtype
Efficiency
Capacity
Block
Ducts
11 Electric Strip Heat/Replaceme None
COP:1
34 kBtuthr
1
sys#1
I
COOLING SYSTEM
1# System Type Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central UnilfReplacement for None
SEER:16 27.6 kBtulhr 828 cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType Location
EF Cap Use
SetPnt
Conservation
1 Electric None Main
I
0.95 40 gal 40 gal
120 deg
None
SOLAR HOT WATER SYSTEM
Collector
Storage
FSEC
1 Cart # Company Name.
System Model # Collector Model # Area
Volume
FEF
1
ft2
None None
I
10/22/201810:56 AM 9Y 9 Ener Gau e® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
1
O
QU
r
ppp
N
000
GDGO
GDCO
GOCD
>
s �
r
r
Got,
nn
COCO
COO
s
LL
U-
COO
r
r
000
Con
GOLD
nn
C08
Coco
OCO
Coco
ZZZ
CY
G0D�
r-ti
mc(o
co co
WW
000
cm
co
0 0
0
v
mn
tiff
mcwo
oom
CLQr
0
y
iC�._,
GD
000
nn
GOLD
nn
GDGD
cOCD
00
COCO
U
I
`m
MOM
m
K
n
tiff
wwww
ww
mm
;n
0
s
��
��
�o
COw
'
w
W
�1
J
f6
N
N
F
c= c
OO
OO
COLD
COLD
nn
nn
Coco
Coto
W
K. _
o
a
ww
nn
pow
com
ww
Coro
M
~
C
��g
E
=
=
c_
U
wwwwCpao
nn
nn
Coco
wwap
COW
0
4QQ
N
nOOD
ww
COO COO
COWOO
s
N
GDO
co Go
COGO
co co
COCO
coc0
Q
O
tiCi-u61.
N
�a
¢a
4n.
¢a
ua
m
s
ui
co
c=c
co
�
r
-10i-mim
.n
a.
C]
W
0
—W--
Y
E
c=c
o
E
_
_
a
0
i
i
cn
ci
Q
co
1p
0
co
0
FORM R40�-2017 -
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
I
i
3505 Ave K, Fort Pierce, FL, 34947
II
1. New construction or eAsting
Addition 9. Wall Types
Insulation
Area
I
a. Concrete Block - Int Insul, Exterior
R=4.0
629.33 ft2
2. Single fatuity or multiple family
Single-family b. N/A
R=
ft2
3. Number of units, if multiple family
1 c. NIA
R=
ft2
4. Number of Bedrooms
1(1) d. N/A
R=
ft2
1orst
10. Ceiling Types
Insulation
Area
5. Is this a case?
No a. Under Attic (Vented)
R=30.0
776.00 ft2
6. Conditioned floor area (ft2)
776 b. N/A
R=
ft2
c. N/A
R=
fF
7. Windows" Description
Area
11. Ducts
R
a. U-Factor: Dbl, U=0.33
77.50 ftZ a. Sup: Attic, Ret: Main, AH: Main
6 155.2
SHGC: SHGC=0.22
b. U-Factor: Dbl, U=0.36
17.78 ft2
SHGC: SHGC=0.24
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: NIA
ftZ a. Central Unit
27.6
SEER:16.00
SHGC:
d. U-Factor: N/A
ftZ 13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
34.0 COPA .00
Area Weighted Average Overhang Depth:
7.818 ft.
Area Weighted Average SHGC:
0.224
8. Floor Types Insulation Area 14. Hot water systems - Replacement equipment
a. Siab-On-Grade Edge Insulation R=0.0 776.00 ftZ a. Electric
b. N/A R= ft2
c. N/A R= ft2 b. Conservation features
None
15. Credits
I
I
I certify in, aI t this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on !installed Colempliant featur>3s.
Builder Signature: �CZ��zpr� Date:
Address of New Home: City/FL Zip:
Cap: 40 gallons
EF: 0.95
Pstat
'''Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
kLabel required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I
10122l201810:56 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
I
i
FORM t1405-2017 Envelope Leakage `rt Report Performance
f
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Performance Method
e:
3505 Ave K
Builder Name: E & B ELITE SERVICES, INC
I
FDesign
3505 Ave K
Permit Office: St Lucie County
ip:
Fort Pierce , FL, 34947
Permit Number:
tion:
FL, ST LUCfE_CO_INTL
Jurisdiction: 611000
Cond. Floor �ea::
776 sq.ft.
Cond. Volume: 6208 cu ft.
Envelope Leakage
Regression Data:
C:
n:
Test Results
Cinnlc nr�Midfi Pnint Test Data
R:
j
HOUSE PRESSURE
FLOW:
1
Pa
cfm
2
Pa
cfm
3
Pa
Cfm
4
Pa
cfm
5 I
Pa
cfm
6
Pa
cfm
Leakage Characteristics
Required ACH(50) from
FORM R405-2017 :
Tested ACH(50) * :
*Tested leakage must be less than or equal to the
required ACH(50) shown on Form R405-2017 for
this building. If the tested ACH(50) is less than 3
the building must have a mechanical ventilation
system.
R402.4.112 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in
Climate Zones 1 and 2 ... Testing shall be conducted with a blower doof at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (f) or an approved
third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be
performed at any time after creation of all penetrations of the building thermal envelope.
Dud I g testing:
11. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be dosed, but not sealed beyond intended infiltration
control measures;
3. Interior doors, if installed at the time of the test, shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed;
5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and
6. Supply and return registers, if installed at the time of the test, shall be fully open.
I hereby certify that the above envelope leakage
performance results demonstrate compliance
with Florida Energy Code requirements in
accordi nce with Section R402.4.1.2.
SIGNATURE:
PRIN 7 NAME:
DATE:
10I221201810:56 AM
Testing shall be conducted by either
individuals as defined in Section
553.993(5) or (7), Florida Statutes or
individuals licensed as set forth in
Section 489.105(3)(f), (g), or (i) or an
approved third party. A written report of
the results of the test shall be signed
by the third party conducting the test
and provided to the code official.
BUILDING OFFICIAL:
DATE:
1tE S?A��®.
WES�'
EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1