Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE - 11-15-18FORM R405-2017 v FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method i EIVEp Project Name: 3505 Ave K Builder Name: E & B ELITE SERVICES, INC Street: 3505 Ave K Permit Office: St Lucie County NOV 0 5 2018 City, State, Zip: Fort Pierce , FL , 34947 Permit Number: Pei Owner: Karleen Watson Jurisdiction: 611000 Climate ent Zone Lu County Design Location: FL, ST LUCIE_CO_INTL County:: St. Lucie (Florida y 1. New construction or existing Addition 9. Wall TYP es 629.3sqft.)Insulation Area ( a. Concrete Block - Int Insul, Exterior R=4.0 629.33 ftz 2. Single family or multiple family Single-family b. N/A R= ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of BedroomkBedrms In Addition) 1(1) 1 d. NIA 10. Ceiling Types (776.0 sqft.) R= Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 776.00 ftz 6. Conditioned floor area above grade (ftz) 776 b. N/A = ftz �R17 tfftz Conditioned floor area below grade (ftz) 0 c. N/A 11. Ducts y,I ;F�,AfA% R ftz 7. Windows( 95.3 sqft.) Description Area Dbl, U=0.33 77.50 ftz a. Sup: Attic, Ret: Main, AH: Main-04 6 155.2 Coll, a. U-Factor: f SHGC f SHGC=0.22 b. U-Factor: Dbl, U=0.36 17.78 fta. 12. Cooling systems Central Unit kBtu/hr Efficiency 27.6 SEER:16.00 SHGC' SHGC=0.24 c. U-Factor: N/A SHGC: 13, Heating systems kBtulhr Efficiency d. U-Factor: N/A ftz a. Electric Strip P Heat 34.0 COPA.00 SHGC: Area We'ghted Average Overhang Depth: 7.818 ft. 14. Hot water systems- Replacement equipment Area Wlghted Average SHGC: 0.224 a. Electric P� Ca 40 gallons 8. Floor Types (776.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 776.00 ft' b. Conservation features b. N/A R= ftz None c. NIA R= ftz 15. Credits Pstat j Total Proposed Modified Loads: 23.39 �7 PASS Glass/Floor Area: 0.123 Total Baseline Loads: 24.12 I I - I hereby certify that the plans and specifications covered by Review of the plans and t -tilE 5r� ¢ this calculation are in compliance the Florida E�7y specifications covered by this AV �`'' ��' '{� Code. calculation indicates compliance �`��,• , a with the Florida Energy Code. :,;,r•- _ ,` a� PREPARED t3Y. Before construction is completed DATE: / D this building will be inspected for compliance with Section 553.908 I 1 hereby certify that this building, as designed, is in compliance Florida Statutes. �0D with the Florida Energy de. WE OWNER/A BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). F� ctj I 10/22I�01810:56 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 I I FORM R405-201 PROJECT Title: 3505 Ave K Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 776 Lot # Owner Name: Karleen Watson Total Stories: 1 Block/Subdivision: # of Units: I 1 Worst Case: No PlatBook: Builder Name: E & B ELITE SERVICES, INC Rotate Angle: 0 Street: 3505 Ave K Permit Office: St Lucie County Cross Ventilation: County: St. Lucie Jurisdiction: 1 611000 Whole House Fan: City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34947 NewlEAsting: Addition Comment: f i CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS FNu Name Area Volume Blocks 776 6208 i SPACES rNuffbers Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated I Main 776 6208 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R Value Area Tile Wood Carpet j 1 Slab -On -Grade Edge Insulatio Main 78.8 ft 0 776 ft2 ____ 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 818 ft2 130 ft2 Medium 0.85 No 0.9 No 0 18.4 ATTIC I i # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 776 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 776 ft2 0.16 Wood 10/22/201 8 10:56 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405 2017 — WALLS Cavity Width Height Sheathing Framing Solar Below o 1 Adjacent Space - -on Ahsnr To Wall Tvpi�p 1 E Exterior Concrete Block - Int Insul Main 4 19 4 8 154.7 ftz 0 0.75 0 _ 2 S Exterior Concrete Block - Int Insul Main 4 26 8 208.0 ft? 0 0.75 0 _ 3 S Exterior Concrete Block - Int Insul Main 4 14 8 112.0 ft2 0 0.75 0 _ — 4 WI Exterior Concrete Block - Int Insul Main 4 19 4 8 154.7 ft2 0 0.75 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall v # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation Int Shade Screening 1 S 2 Vinyl Low-E Double Yes 0.33 0.22 N 31.0 ft2 2 ft0 in 1 ft 0 in None None 2 S 3 Vinyl Low-E Double Yes 0.33 0.22 N 31.0 ft2 14 ft0 in 1 ft0 in None None 3 1 S 3 Vinyl Low-E Double Yes 0.36 0.24 N 17.8 ft2 14 ft0 in 0 ft 6 in None None 4 1 W 4 Vinyl Low-E Double Yes 0.33 0.22 N 15.5 ft2 Oft 0 in Oft0 in None None I INFILTRATION # 7SScoppl Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 517.3 28.4 53.41 .1906 5 HEATING SYSTEM System Type Subtype Efficiency Capacity Block Ducts 11 Electric Strip Heat/Replaceme None COP:1 34 kBtuthr 1 sys#1 I COOLING SYSTEM 1# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central UnilfReplacement for None SEER:16 27.6 kBtulhr 828 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main I 0.95 40 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM Collector Storage FSEC 1 Cart # Company Name. System Model # Collector Model # Area Volume FEF 1 ft2 None None I 10/22/201810:56 AM 9Y 9 Ener Gau e® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 1 O QU r ppp N 000 GDGO GDCO GOCD > s � r r Got, nn COCO COO s LL U- COO r r 000 Con GOLD nn C08 Coco OCO Coco ZZZ CY G0D� r-ti mc(o co co WW 000 cm co 0 0 0 v mn tiff mcwo oom CLQr 0 y iC�._, GD 000 nn GOLD nn GDGD cOCD 00 COCO U I `m MOM m K n tiff wwww ww mm ;n 0 s �� �� �o COw ' w W �1 J f6 N N F c= c OO OO COLD COLD nn nn Coco Coto W K. _ o a ww nn pow com ww Coro M ~ C ��g E = = c_ U wwwwCpao nn nn Coco wwap COW 0 4QQ N nOOD ww COO COO COWOO s N GDO co Go COGO co co COCO coc0 Q O tiCi-u61. N �a ¢a 4n. ¢a ua m s ui co c=c co � r -10i-mim .n a. C] W 0 —W-- Y E c=c o E _ _ a 0 i i cn ci Q co 1p 0 co 0 FORM R40�-2017 - ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. I i 3505 Ave K, Fort Pierce, FL, 34947 II 1. New construction or eAsting Addition 9. Wall Types Insulation Area I a. Concrete Block - Int Insul, Exterior R=4.0 629.33 ft2 2. Single fatuity or multiple family Single-family b. N/A R= ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 1(1) d. N/A R= ft2 1orst 10. Ceiling Types Insulation Area 5. Is this a case? No a. Under Attic (Vented) R=30.0 776.00 ft2 6. Conditioned floor area (ft2) 776 b. N/A R= ft2 c. N/A R= fF 7. Windows" Description Area 11. Ducts R a. U-Factor: Dbl, U=0.33 77.50 ftZ a. Sup: Attic, Ret: Main, AH: Main 6 155.2 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.36 17.78 ft2 SHGC: SHGC=0.24 12. Cooling systems kBtu/hr Efficiency c. U-Factor: NIA ftZ a. Central Unit 27.6 SEER:16.00 SHGC: d. U-Factor: N/A ftZ 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COPA .00 Area Weighted Average Overhang Depth: 7.818 ft. Area Weighted Average SHGC: 0.224 8. Floor Types Insulation Area 14. Hot water systems - Replacement equipment a. Siab-On-Grade Edge Insulation R=0.0 776.00 ftZ a. Electric b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits I I I certify in, aI t this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on !installed Colempliant featur>3s. Builder Signature: �CZ��zpr� Date: Address of New Home: City/FL Zip: Cap: 40 gallons EF: 0.95 Pstat '''Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. kLabel required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I 10122l201810:56 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 I i FORM t1405-2017 Envelope Leakage `rt Report Performance f FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method e: 3505 Ave K Builder Name: E & B ELITE SERVICES, INC I FDesign 3505 Ave K Permit Office: St Lucie County ip: Fort Pierce , FL, 34947 Permit Number: tion: FL, ST LUCfE_CO_INTL Jurisdiction: 611000 Cond. Floor �ea:: 776 sq.ft. Cond. Volume: 6208 cu ft. Envelope Leakage Regression Data: C: n: Test Results Cinnlc nr�Midfi Pnint Test Data R: j HOUSE PRESSURE FLOW: 1 Pa cfm 2 Pa cfm 3 Pa Cfm 4 Pa cfm 5 I Pa cfm 6 Pa cfm Leakage Characteristics Required ACH(50) from FORM R405-2017 : Tested ACH(50) * : *Tested leakage must be less than or equal to the required ACH(50) shown on Form R405-2017 for this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation system. R402.4.112 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2 ... Testing shall be conducted with a blower doof at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (f) or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Dud I g testing: 11. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be dosed, but not sealed beyond intended infiltration control measures; 3. Interior doors, if installed at the time of the test, shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed; 5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the time of the test, shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordi nce with Section R402.4.1.2. SIGNATURE: PRIN 7 NAME: DATE: 10I221201810:56 AM Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the third party conducting the test and provided to the code official. BUILDING OFFICIAL: DATE: 1tE S?A��®. WES�' EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1