HomeMy WebLinkAboutPROJECT INFORMATION- wrightsoft® Project Summary Entire House E & B ELITE SERVICES, INC Phcna For. 3505 Ave K Karieen Watson 3505 Ave K, Fort Pierce, FI Notes: RECEIVED NOV_0 5 2010 Per nIttlng Deportm®nt St. LUde County Weather. Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 15804 Btuh Duds 4859 Btuh Central vent (0 dim) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 20663 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heatin Coolin Area (fF) gg 1760_ , 176 Volume (ft3) 14080 14080 Air changes/hour 0.38 0.20 Equiv AVF (cfm) 89, 47 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Airflow factor Static pressure Space thermostat 100 EFF 6.0 kW 20452 Btuh 0 OF 371 cfm 0.018 cfmBtuh 0 in H2O Jot: Date: Oct 18, 2018 By: 00ANX2I}-1 BY 81 Lucie County Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Sensible Cooling Equipment Load Sizing Structure 12380 Btuh Ducts 6519 Btuh Central vent (0 cl m) 0 Btuh (none) Blower 1707 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 19575 Btuh Latent Cooling Equipment Load Sizing Structure 2761 Btuh Ducts 2081 Btuh Central vent (0 cfim) 0 Btuh (none) Equipment latent load 4841 Btuh Equipment Total Load (Sen+Lat) 24416 Btuh Req. total capacity at 0.75 SHR 2.2 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN Cond GSX160301F Coil ASPT30C14A AHRI ref 200825240 Efficiency 13.0 EER,16 SEER Sensible cooling 20700 Btuh Latent cooling 6900 Btuh Total cooling 27600 Btuh Actual airflow 920 dm Air flow factor 0.049 cfrn/Btuh Static pressure 0.10 in H2O Load sensble heat ratio 0.81 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. - wrightsoft- 1-2211:13: m4. RW-Su1b0Un&wW201818.0.31 RSU06570 Page tart rWmuaIM505Ave K-kntw VV tsm rup CaIc= MJ8 FrmffDoorfaces: N Y - - rrlghtsoft- Right=.i@ Worksheet Entire House E & B ELITE SERVICES, INC Fhme:772) 577-0826 CELL Job: Date: Oct 18, 2018 By: 1 l-om name Entire House newbednn 2 Exposedwal 168.0 ft 47.0 ft 3 Room height 8.0 It 8.0 It heaHcool 4 Room dinensons 1.0 x 450.0 ft 5 Room area 1760.0 ttz 450.0 ftz Ty Construction U-vakie Or HTM Area (1F) Load Area M) Load number (Btuhlfl;°� (BtuhAC�) or perimeter (ft) (Btrih) or perimeter (ft) (Bluh) Heat Cool Gross NIPS Heat Cool Gross NIPS Float Cool 6 1N 13A flocs , 0.143 "n 4.60 . 256 320 ". 255 `1021 649 ' 0 0 0 0 E-G 4A42ov 0.470 n 13.16 16AS 44 0 . 579 725 0 0 0 0 D 11P0 0290 .. n 8.12 r ._. 8.41 27 : .._,.. 21 ` _ _171 177 _ :_ 0 .. 0 0 _ 0 w 13A-4ocs 0.143 a 4.00 Z55 352 352 1409 896 264 254 _ ^ 1057 672 I W� _ , 0.143 2.56 320 24111 613 - 112 97 38 8 ' 247 10a s 13.00 2964 4A4-2ov 0.470 s, . 13.16 18.35 30 0 395 1550 15 0 197 275 L—G4A4-2ov, . 0,470 s . 13,16 . 16,48 . `30 30 395 495 ; 0 _ 0 ".0'. 0 13AAocs 0.143 w 4.00 2.55 352 316 1265 804 0 0 0 0 E—G 4A4-2ov 0.470 w 13,16 5029 15 0 197 754 0 0 0 0 t D 11P0 0.290 w 8.12 8.41 21 21 171 177 0 0 0 0 C 16B-30ad; D032 " . ,- 0 0 1.68 1760 ,1760 .' ,15n 2957 ;- '" 450 450 403 . 756 F 22A tl 0989 . - . 27.69 0.00 1760 168 4652, -0 450 47 1302 0 6 c)A®excursion 0 -17 Envelope bss/gan 13060 8986 3348 1933' 12 a) InTration 2744 774 768 216 0) Room ventlatbn 0 0 0 0 13 I�rtemalgans: Occupants@ 230 4 920 2 460 Appliances/other 1700 0 Subtotal (Ines 61013) 15804 12360 4115 2610 111essex.malload 0 0 0 0 Less transfer 0 0 0 0 Redistrbu6Dn 0 0 4 7 14 Subtotal 15804 12380 4119 2616 15 Ductbads 31% 53-/.j 4859 6519 31% 53% 1266 1378 Total room bad 20663 18899 1 5385 3994 A r r eg4ed (ctim) 371 920 97 194 Calculations approved byACCAto wrGg^Frtso_ft^ - Rght-Su1e9Universa1201818.0.31 RSU06570 ransierVNarualJ3505AveK-IarleenVV smrup Cab=MJ8 Front Doorfaoes: N 2018-Oct 2211:13:47 page 1 - wrlghtsoft' Right-:iO Worksheet J zo,a Oct ,a, Entire House By. E & B ELITE SERVICES, INC i Phone:772) 577-0826 CELL 1 Room name bth ully 2 Exposedwal O ft O ft 3 Room height 8.0 It heat(cool 8.0 ft heat/cool 4 Ioom d'mensnns 5.0 x 11.0 ft 5.0 x 11.0 It 5 Room area 55.0 1F 55.0 T Ty Construction llvatJe Or HTM Area (it-) Load Area T) Load number (Btuh/ItL°F) (BtuhfF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NlP/S Heat Cool Gross NIP/S Heat Cool 6 W I. C 13A-4ocs 0.143 n 4.00 256 0 0 0 0 0 0 0 0 .4A4-2ov 0.470 n. 13:16 16.48 0 0 0 0 0 0: 0 0 D 11P0 0.290.-n....: Al2 -. • .BA1 0 0 .._ .,-.0 0 -0 . 0 - "0' -. 0 w, 13A-4ocs 0.143 e, 4.00 _ 255 0 . _ 0 0 _ - 0 0 0 0 0 11 13A-0ocs .. - 0.143 s' 4.00 255 0 0 0 0 0 0 0 0 t 10D•v 0.490 13.72 -9.84 0 "0 0 0 0 0 0 0 4A4-2ov .. 0.470 ,s s 13.16 18.36 6 0 0 0 6 0' 0 0 AA4-2ov ` .-`... - 0.470 . s : 13.16 16.48 - •0 ' 0, 0 . ',0 0 -. 0 VL13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 4A4-2ov 0.470 w 13.16 50.29 0 0 0 0 0 0 0 0 D 11P0 0,290 8A2 8.41 0 0 0 0 0 0 0 C I 166-_ d 0.032 -w ' - 0.90 - t 1.68 _ .0 55 55 . 49• ,. , " . -92 55 55 ., , .. 49 ._ 92 F 22A-ti _ .- 0.989 - . 27.69 . 0.00 ... 55 0 ... 0 _ —0 55 _ 0 _ - _ .0 0 6 c)A®excursion -2 -15 Envebpe loss/gain 49 90 49 77 12 a) Inffir lion 0 0 0 0 b) Room ventilation 0 0 0 0 13 InItemalgains: Occupants@ 230 0 0 0 0 Applances/other 0 500 Subtotal (Fes 6 to 13) 49 90 49 577 Less external bad 0 0 0 0 Less transfer 0 0 0 0 Redistrbufim 4 7 0 0 14 Subtotal 53 97 49 5T7 15 Ductbads 31% 53% 16 51 31% 53% 15 304 Totalroombad 69 147 64 881 Au required (cfrn) 1 7 1 43 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -4- wrGg"tsoft- 2018-Cci 2211:13:47 Rght-Suie®Univesa1201818.0.31 RSU06570 Page2 '4C��' -rmsftrWlmualJW05AveK-i®risenVl&w.rup Cab =MJ8 Front Door tax&- N wrightsoft° Right=,,J Worksheet Job. - Entire House Date: Oct 18, 2018 By: E & B ELITE SERVICES, INC Fhme:772) 577-0826 CELL 1 Room name bedrm kkhen&iTng 2 Exposed wal 39.0 ft 37.0 It 3 Room height 8.0 ft heatfcool 8.0 it heathool 4 Room dinensuns 28.0 x 11.0 ft 1.0 x 398.0 ft 5 Room area 308.0 tt= 398.0 T Ty Construction LLvalue Or HTM Area (W) Load Area OF) Load number (BhrhfiF -°F) (BtuhtY) or perimeter (ft) (Btuh) or perimeter (ft) (Bhih) Heat Cool Gross "PIS Heat Cool Gross NIPS Heat Cool 6 W 13A-flocs .4A4-2ov 11 PO ` 0143 0.476 0290 , n " n . n 4.00 13.16 8:12 �. `255 16.48 , 8:41 224 .24 0 2bo 0 ... 0 .. " 801" . 316 `0 .509 396 .. 0 96 ' 20 21 55 '0 21 220 253 - - " ' 171 140 330 ... 177 L— �� D w 13A-4ocs 0.143 a 4.00 2-55 88 88 352 224 0 0 0 0 11 13A-0acs` 0143 s.- 4.00 265 0 0- 0 0 0, 0 0 0 1013-v 0490 s 13.72 9.84 .0 , 0 0 0 0 0 0 0 4A4-2ov 0.470 s 13.16 18.35 0 0 0 0 A 0 '0 0 —G 4A4-2ov ";. . _ 0.470 , s' 13.16, . 16.48 '0 0 : 0 "0 0 0 0 0 1/ G 134-4ocs 0.143 w 4.00 255 0 0 0 0 200 179 717 456 4A4-2ov 0.470 w 13.16 5029 0 0 0 0 0 0 0 0 D 11 PO 16B-30ad` ., . '- 0.290 0032 w `'= 8.12 , , . 0.90 8A1 ::9.68 0 ; 308 0 308 0 � „ ,.: '276 _ 0 _ �517 21 ; 398 21 398 171 , , 357 177 ' 669 O. F .. 22A mt 0.989 - 27.69 _ .. 0.00 . 368 39 .. 1080 ... _ 0 ... . 398 . - 37 1025 0 61 c)AEDexcursion 58 -85 Envelope bss/gan 2825 1588 2922 1863 12 a) Inflation 637 180 604 170 ti) Room wntlatbn 0 0 0 0 13 16malgans: Occupants@ 230 2 460 0 0 Applances/other 0 1200 Subtotal(ines6to13) 3462 2228 3527 3233 Less external bad 0 0 0 0 Less transfer 0 0 0 0 Redistribufim 0 0 0 0 14 Subtahal 3462 2228 3527 3233 15 Ductbads 31% 53% 1064 1173 31% 53% 1084 1702 Total room bad 1 4526 3400 1 4611 4935 Air required (cfm) 81 166 83 240 all requirements of Manual J 8th Ed. Rght-9uie1DUnivasd201818.0.31 RSU06570 ransferW ualJ13505AveK-karbenWalsmxup Cab=MJ8 FrontDoorf om N 2018-W 2211:13:47 Page 3 I. wrightsoft° Phone:772) 577-0826 CELL Righf-A, Worksheet Entire House E & B ELITE SERVICES, INC Job: Date: Oct 18, 2018 By: 1 Room name alh ding 2 Exposed me] 0 ft 17.0 ft 3 Room height 8.0 ft heaUcool 8.0 ft heatbool 4 5 Roomdimensbns Room area 4.0 x 4.0 ft 16.0 ft2 1.0 x 2830 ft 283.0 fg Construction U-value Or HTM Area (f8) Load Area (fe) Load ly number (Bhihill;-T) (BtuhAt2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S heat Cool Gross NIP/S Heat Cool 6 11 W. �L---G 13A-flocs ; 4A42ov - 11 PO 13A4oc's , 13A flocs` 10D v :im-2ov _ 4A4-26v _. 0.143 '•0.470 0.290 0.143 0.143 0.490 0.470 6.470 n ' n' n _ e s s ' s s 4'.00 13.16 8.12 4.00 4.00 13.72 13.16 13.16 ", -55 16.48 8.41 255 2.55 0.84 18.35 16A8 0 0 , . 0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 . 0 .0 0 .. 0 0, 0 0 - 0 . ': 0 0 0 0 .:. 0 0 . : 0 _ 0 . 104 19 0 30 r 0 0. 0 -_ 0 55 ` 19 0 30 "0. 0 . 0 0 :. 219 264 0, 395 0 0 . 0, - 0 ' . 139 190 0 495 `D W, ! V�fI I13A-flocs - 4A42ov 11 p0 166-30ad 0.143 0.470 0.290 am w w w - .. 4.00 13.16 8.12 ' 0.90 255 5029 8.41 _- -' AM 0 0 0- - '. 16 0 0 0 16 0 0 0 14 0 0 0 27 32 0 0 . 283 32 0 0 2W 128 0 0 ' 254 81 0 0 475 �-G D C � F 2 0.989 - 27.69 _. 0.00 - 16 . - . 0 _. ._ .0 0 _ .. 283 _ 17 - 471 0 6 c)AEDexcursion -1 -37 Envelope loss/gab 14 26 1731 1343 12 a) I. ation 0 0 278 78 b) Room ventilation 0 0 0 0 13 InlItemalgaiis: Occupants@ 230 0 0 0 0 Appfances/other 0 0 Subtrrtal (fines 6 to 13) 14 26 2008 1421 Less exlemal bad 0 0 0 0 Less transfer Redistrtbufim 0 -14 0 -26 0 7 0 13 14 15 Subbtal Duct bads 31% 53% 0 0 0 0 31% 53% 2016 620 1435 755 Tolalroom bad 0 0 2635 2190 A'r, required (cfm) 0 0 47 107 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. _ I A- wrioft*so_ft:- 2018-�2211.13:47 Rght-8 k&Universal201818.0.31 RSU06570 p�4 AC�fa'...ransfeNJtualJW05Ave K-IarleenWblsonxup Cab=W8 FrontDcorfaxs: N -��- virrightsoft° Phone: 772) 577-0826 CELL Righti ;J Worksheet Entire House E & B ELITE SERVICES, INC Job: Date: Oct 18, 2018 By: 1 Room name game rm 2 Exposed wal 28.0 It 3 Room heght 8.0 ft heaUcool 4 Room d'mensbns %0 x 15.0 ft 5 Room area 195.0 W Ty Construction U- akje Or HTM Area (f) Load Area Load number (BtuhlfP-°F) (BtuhAP) or perimeter (ft) (Btuh) or perineter Heat Cool Gross N(P/S Heat Cool Gross NIPlS Heat Cool 6 :W� 13A-0ocs +: 0.143 . n .° 4.00 " Z55 0 ",, 0 1 0 0 4A4-2ov 0.470 'n 13.16 16.48 0 0 . .0 0 D 11 FO " 0290. n 8.12 8.41 0 0 . 0 .. 0 _ W; 13A4ocs 0.143 a 4.00 2.55 0 0, 0 0_ 11 I 13AAocs 0.143 is . 4.00 265 104 Eb 356 227 0 _ 1013-v' , 4A4-2ov 0.490 V0.470 s' s 13.72 1516 " " 9.84 18.35 0 15 0 0 _ 0 197 : M :. 4A4-2ov 0.470 s ,1316 16.48 0 , 0 0 0 • \ItJj 13AAccs 0.143 w 4.00 2.55 120 105 420 267 �L'_O 4A42ov 0.470 w 13.16 5029 15 0 197 754 D_ 11 PO 0290 w 8.12 8.41 0 0 0_ 0 g `,: 968 30ad .: : 0.032 ,. -".. ... ' 0.90 1:68 195 ...,. 195 :- •` .175 r •, . 328 F 1 22A4p1 0.989. - 27.69 0.00 195. - 28 -_ 775 0 " Envelope loss/gain 2122 2066 12 a) Inl1 ation 457 129 b)I Room ventilation 0 0 13 Intemalgains: Occupants@ 230 0 0 1 Applances/other 0 Subtotal(lines 6to13) 2579 2195 Less external bad 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2579 2195 15 Duct bads 31% 53% 793 1156 Total room bad 3372 3350 Ailrequied (cfm) 611 163 I Calculations approved byACCAto meet all requirements of Manual J 8th Ed. arvrYghtsoffY 5 R'ghtSu�Un'iversa1201818.0.31 RSU06570 2018O:t2211Page ��` I_.ransferWa,ualJG505Ave K-IarleenWdsm.rup Calo=MJ8 Front Door faces: N � i Ste, 1 Job P Performed for. 3505A%eK 3505 AeeK FortPiaop, R E & B ELITE SERVICES, INC Phone: 772) 577-0826 CELL Scale.1: 69 Pagel R1ght&ha@ Universd 20l 8 18.0.31 RSU06570 2018-Oct-2211:1639 _M505 Are K-kadeen Watson rup -- wrightsoft® Manual S Compliance Report Entire House E & B ELITE SERVICES, INC Phone 772) 577-w26,-=L For. 3505Ave K, Karteen Watson 3505Ave K, Fort Pierce, FI Conditions or design DB: 90.0°F Sensible gain: 20605 Btuh or design WB: 78.0°F Latent gain: 4841 Btuh design DB: 75.0°F Total gain: 25447 Btuh RH: 50% Estimated airflow: 920 ch acturees Performance Data at Actual Design Conditions )menttype: SpIitAC afacturer. Goodman Mfg. Model: GSX160301 F+ASPT30C14A al airflow: 920 c fm ;ible capacity: 21806 Btuh 106 % of load it capacity: 5515 Btuh 114 % of load capacity: 27320 Btuh 107% of load SHR: 80% Conditions x design DB: 42.0°F Heat loss: 20663 Btuh design DB: 70.0°F Aurer's Performance Data at Actual Design Conditions nent type: Elec strip acturer. Model: airflow: 371 cam : capacity: 6.0 kW 99% of load Is all requirements ofACCA Manual S. Job: Data: Oct 18, 2018 By: Entering coil DB: 79.1 OF Entering coil WE 64.5°F Entering coil DB: 67.7°F Temp. rise: 50 OF wrightsoft- 2018-Oct 2211:13A8 RghtSuMSUnNersd201818.031 RSU06570 1 rant rVmualJl3505Ave K-larlm VV&m.rup Cak= MJ8 Front Door faces: N J +wrightsoft Phone: 772) 577-0826 CELL A Duct System Summary Entire House E & B ELITE SERVICES, INC ror. 3bubAve K, Kaneen watson 3505Ave K Fort Pierce, FI Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowestfriction rate Actual air flow Heating 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 371 cfm Job: Date: Oct 18, 2018 By: Cooling 0.10 in H2O 0 in H2O 0.10 in H2O 0.050/0.050 in H2O 0.069 in/100ft 920 ch Name Design (Btuh) Htg (CFM) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk i c 3400 81 166 0.069 7.0 Ox 0 VIFx 24.7 120.0 st1 bth c 147 1 7 0.077 4.0 Ox 0 MFx 15.7 115.0 st1 &rt9 c 2190 47 107 0.093 6.0 Ox 0 VIFx 8.0 100.0 gane,rm c 3350 61 163 0.083 7.0 Ox 0 VIFx 21.0 100.0 iaa,,9 C 2468 41 120 0.069 6.0 Ox 0 MFx 24.1 120.0 st1 Idchm/1&9-A C 2468 41 120 0.083 6.0 Ox 0 VIFx 21.1 100.0 new Wan C 1997 48 97 0.088 6.0 Ox 0 VIFx 14.2 100.0 new"rFA C 1997 48 97 0.089 6.0 Ox 0 VIFx 12.1 100.0 Uwv C 881 1 43 0.073 4.0 Ox 0 VIFx 16.5 120.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FIR 00m) (in) (in) Material Trunk st1 PeakAVF 125 336 0.069 616 10.0 0 x 0 VinlFlx Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (Cfm) (Cfm) (ft) FIR (fpm) (in) (in) Opening (in) Mat Trunk rb1 Ox 0 178 360 0 0 0 0 Ox 0 MFx rb5 Ox 0 193 560 0 0 0 0 Ox 0 MFx Boldlrtal/c values have been manually overridden wrightSOft" 20184Dct-2211:13:48 Rght-SLfe6UnNen;d201818.0.31 RSU06570 paw _.rarsWWarua1JWWAveK-W@enWdsonrup Calc=MJ8 FrontDoorfaoes: N