HomeMy WebLinkAboutNOA - SHINGLESKIAM
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
'ICE OF ACCEPTANCE (NO
GAF
1 Campus Drive
Parsippany, NJ 07054
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
t Lucie County 5 �, 1
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used ih Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD®, Timberline' Natural Shadow®, Timberline® American Harvest®, and
FortitudeTM Shingles
LABIELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
I
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TER, VIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
'ISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall The available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA # 14-1022.20 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera. FILE
COPY
MIAMI•DADE COUNTY "+1,NOA No.: 16-0811.11
Expiration Date: 02/21/22 '
Approval Date: 02/09/17
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
�ategory: Roofing
Sub -Category: Asphalt Shingles
Materials: Laminate
)eck Tvne: Wood
This approves GAF Timberline HD®, Timberline® Natural Shadow®, Timberline American® Harvest®, and
FortitudeTM Shingles as manufactured by GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Timberline HD® 13 '/a . x 39 3/8
., TAS 110 Fiberglass reinforced heavy weight asphalt
Manufacturing roof shingle, with a laminate profile
Locations #1, 2, 3, 4, 5, 6, 7
GAF Timberline Natural 13 '/a , x 39 3/8, TAS 1.10 Fiberglass reinforced heavy weight asphalt
Shadow® roof shingle, with a laminate profile
Locatio�7s #1, 2, 3, 4, 5, 6, 7
GAF Timberline® American
Locations #2, 4, 5, 6
GAF FortitudeTM
Location 04
13 '/4" x 39 34" TAS 110
13 '/4"x 39 3/8" TAS 110
MANi7FACTURING LOCATION
1.
FL
2.
-�ampa,
IV�ichigan City, IN
3.
4.
Baltimore, MD
l�yerstown, PA
5.
Ennis, TX
6.
1 uscaloosa, AL
7.
Dallas, TX
i
MIAMI•DADE COUNTY
Fiberglass reinforced heavy weight asphalt
roof shingle, with a laminate profile
Fiberglass reinforced heavy weight asphalt
roof shingle, with a laminate profile
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 2 of 6
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
Underwriters
Laboratories,LLC
ASTM D3462
4787344101
07/25/16
Underwriters
Laboratories, Inc.
ASTM D3462
I ICA48924
10/24/11
Underwriters
Laboratories, Inc
ASTM D3462
10CA21994
04/22/11
Underwriters
Laboratories, Inc
ASTM D3462
10CA28717
07/26/11
Underwriters
Laboratories, Inc.
ASTM D3462
05CA47541
11/10/06
Underwriters
Laboratories, Inc.
ASTM D3462
06CA31580
11/30/06
PRI Asphalt
Technologies, Inc.
ASTM D3462
GAF-101-02-02
11/02/05
Underwriters
Laboratories, Inc.
ASTM D3462
06NK05159
08/09/06
PRI Asphalt
Technologies, Inc.
ASTM D3462
GAF-098-02-02
11/08/05
Underwriters
Laboratories, Inc.
ASTM D3462
02NK41809
08/11/02
Underwriters
Laboratories, Inc.
ASTM D3462
03NK26444
10/17/03
Center for
Applied Engineering
ASTM D3462
257989
05/13/97
Underwriters
Laboratories, Inc.
TAS 107
01NK45803
04/13/94
Underwriters
Laboratories, Inc.
TAS 107
06NK05159
08/09/06
Underwriters
Laboratories, Inc.
TAS 107
04NK04273
02/20/04
Underwriters
Laboratories, Inc.
TAS 107
05CA42840
11/11/05
Underwriters
Laboratories, Inc.
TAS 107
02NK41811
11/11/02
Underwriters
Laboratories, Inc.
TAS 107
03CA35209
10/17/03
Underwriters
Laboratories, Inc.
TAS 107
04CA13850
08/30/04
Center for
Applied Engineering
TAS 100
257989
04/01/97
PRI Asphalt
Technologies, Inc.
TAS 100
GAF-044-02-01
01/13/04
PRI Asphalt
Technologies, Inc.
TAS 100
GAF-098-02-01
11/08/05
PRI Asphalt
Technologies, Inc.
TAS 100
GAF-101-02-01
11/09/05
PRI Asphalt
Technologies, Inc.
TAS 100
GAF-116-02-02
03/23/06
PRI Asphalt
Technologies, Inc.
TAS-100
ELK-083-02-01
10/16/02
ELK-084-02-01
10/15/02
ELK-0 85 -02-01
10/ 14/02
ELK-0 8 6-02-01
10/24/02
ELK-0 8 7-02-01
10/21 /02
ELK-0 8 8 -02-01
10/ 16/02
ELK-107-02-01
10/09/03
ELK-108-02-01
10/09/03
ELK-109-02-01
10/09/03
✓II ATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 3 of 6
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
Shingles shall bear the imprint or identifiab]
manufacturing facility, and following statement:
County] Product Control Seal as shown below.
C
BUILDING PERMIT REQUIREMENTS
marking of the manufacturer's name or logo, city and state of
"Miami -Dade County Product Control Approved" or the Miami -Dade
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 4 of 6
DETAIL A
COURSE LAYOUT
NOA No.: 16-0811.11
MIAMI•DAD; COUNTY Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 5 of 6
DETAIL B
OVERALL DIlVII woNs AND NAILING PATTERN
39-3/8"
low I
I 14-1/2"-17-1%2" 14-1/2"-17-1/2" —
j (368-445mm) (36.8="5mm) .
I(337mm)4!-
1!2" - 2-1/2'
(19-84
f
f ENHANCED NAILING. PATTERN'- six nails per shingle*
' required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for demis.
These shingles MUST be nailed a nominal 6 (152mm) from bottom of
of shingle, above the cut outs, as shown. Nails'must not be exposed.
END OF THIS ACCEPTANCE
Nail guide line
5-314" 6-1/4"
(146mm-159mm)
from bottom of shingle
Self seal
adhesive .
on back
NOA .No.: 16-0811.11
Expiration Date: 02/21/22