HomeMy WebLinkAboutLOAD CALCULATIONOptional Load Calculation
Heat Larger Than Air
163 SF x 3VA Living Only
(2) Small appliance ckts @ 1500VA each
Refrigerator @ 1500
Refrigerator @ 1500
Freezer @ 1500
Washing Machine @ 1500
Dishwasher @ 1500
Disposal @ 1500
Mini Sewer @ 1500
Clothes Dryer @ 5000
Range @ 12000
Water heater @ 4500
Fixed icrowave @ 1500
Vacuu @ 1500
Trash �ompactor @ 1500
Pool Heater @ 'name plate'
Spa @ 'name plate'
Motor 746VA per HP Pie>o j
Garage Door Opener X 2—
Tota I
First 10 KVA of general load @ 100%
Subtract line 2 from J.
Multiply line 3 @ 40%
Add lines 2 and 4
60/50amp breaker for heat (10000)
40/30amp breaker for heat (5000)
Total heat- Add lines 6 and 7
Multiply line 8 @ 65%
Add lines 5 and 9
Divide line 10 by 240
Summary:
Line 10 is the total KW
Line 11 is the total Amps
3000
- 3
:'cad
P500
wit��
2. (Generator Size Needed)
_ (Breaker Size Needed)