Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GAS PIPING SCHEMATIC
BOARD OF COUNTY COMMISSIONERS GAS PIPING SCHEMATIC [A2] [L4] TANK L1 1.3 LS SIZE L2] [L6] [Al] [A►3] 1 TANK SIZE: GALS. APPLICANCE — TYPE/SIZE Al Wj% '.g A2 jer, A3�w A5 A6 PIPI L1 L3 73 1 I_& FT. L5 I FT. L6 P FT. L7_ / ! FT. L8 FT. L9 FT. L10 FT. L11 FT. L 12 FT. Revised 7/22/14 PLANNING & DEVELOPMENT SERVICES DEPARTMENT Building and Code Regulation Division [A►4] [A6] RFce 1FP o [L8] [L12] 10. �i�'�9 . 13 cu�jPID L7 L9 L11 c�`i Wie 17, [A5] ST. "CIE COUNTY BUILDING DIVISION � REVIEWED FOR C REVIEWED BY MPLIANCE DATE PANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE. BTU d 66 BTU 6 3" t BTU BTU BTU BTU (PIPE E WAS TAKEN FROM INCH DIA. THE 2094 FUEL GAS CODE- INCH DIA. TABLE 402 (�) "d INCH DIA. INCH DIA. oe INCH DIA. V_ INCH DIA. INCH DIA. L INCH DIA. a �— INCH DIA.iC�t1t INCH DIA. INCH DIA. INCH DIA. FILECOPYWebsite: www.stlucieco.aov 2300 Virginia Avenue - Fort Pierce, FL. 34982-5652 Phone (772) 462-1553 FAX (772) 462-1578 T. oee - ` kg 15 )14 161 bS O a wo Grl' \\ () LP TOE I� L)nc)(!r-,,r aQ GAS PIPING INSTALLATIONS 7TENDED USE TABLE 402.28 SCHEDULE 40 METALLIC PIPE between or Gas Undiluted Propane Inlet Pressure 11.0 in. w.c. Pressure Drop 0.5 In, w.c, Specific Gravity 1.50 tags (low pressure) regulator and. oollanca Nominal , PIPE SIZE (inch) Actual ID Length (ft) 0.6Z2 0.624 1 1.049 Jill: 1.360 11/2 2 10 291 608 Capacity in 1.610 Thousands 2.067 of Btu per Hour 20 200 418 1,150 2,350 3,520 6,790 30 160 336 • 787 632 1,620 2,420 4,660 40 137 287 1,300 1,940 3,750 50 122 255 480 11110 1,660 3,210 60 110 231 434 985 1,480 21840 80 101 212 892 1,340 2,570 100 94 197 72 21 1,230 2,370 125 89 185 349 63 716 1,140 2,200 150 84 175 330 1,070 2,070 175 74 155 292 677 677 11010 1,950 200 67 140 265 600 899 1,730 250 62 129 243500 543 814 1,570 300 58 120 227 749 1,440 350 51 107 �01 465 697 1,340 46 97 182 618 1,190 � 44500 1 500 42 89 167 3732 344 560 1,080 550 40 37 83 156 320 515 991 600 35 73 146 300 449 865 1 650 33 70 138 283 424 817 700 32 66 131 125 269 403 776 750 1800 30 61 120 257 246 1850 29 28 115 236 368 354 7009 900 27 59 57 111 227 349 681 656 950 1;000 ?6 55 107 104 220 213 329 634 1,100 25 53 100 213 319 613 1,200 25 24 52 97 200 300 300 595 1,300 23 50 48 95 195 292 578 562 1,400 22 46 90 86 185 277 534 11500 21 44 82 176 264 507 1,600 20 42 79 169 243 468 1,700 19 40 76 162 243 468 11800 19 39 74 156 234 6 451 11900 38 71 151 436 2,000 For SI: 1 inch = 25.4 18 37 146 219 212 422 409 nal 1 foot h hour 1 British thermal unit per hour = 0.2931 W,1 cubic foot per hour = .29 1 pound per square inch = 6.89521cPa, 1-inch water column Note: All table entries have 0 2488 Id?a, been rounded to three significant digits. = 0.0283 m3/h, 1 degree = 0.01745 rad. FLORIDA B IILDING CODE - FUEL GAS, 6th EDITION (2017) cy2 3 4 2.41 3.066 4.026 10,800 19,100 39,000 7,430 13,100 26,800 5,970 10,600 21,500 51110 9,030 18,400 4,530 81000 16,300 4,100 7,250 14,800 3,770 6,670 13,600 3,510 6,210 12,700 3,290 5,820 11,900 3,110 51500 11,200 2,760 4,880 9,950 2,500 4,420 91010 4300 4,060 81290 2,140 3,780 7,710 1,900 3,350 6,840 1,720 3,040 6,190 1,580 2,790 5,700 1,470 2,600 5,300 11380 2,440 4,970 11300 2,300 4,700 1,240 2,190 4,460 11180 2,090 4,260 1,139 2,000 4,080 11090 1,920 3,920 11050 1,850 3,770 11010 1,790 3,640 978 1,730 3,530 948 1,680 3,420 921 1,630 3,320 895 1,580 3,230 850 11500 3,070 811 1,430 2,930 777 1,370 2,800 746 1,320 2,690 719 1,270 2,590 694 1,230 2,500 672 1$190 2,420 652 1,150 1) acn 53 .-. -"�-'" t..r "",.+�Y'.:'�F'-""K'' ?�T�� �.�r^.�+t'ye F'' T:���'^`£`'...a �a-r r'W. �r•�'�{};a� � ,3`,..,�'"' �'�'-'Y�rf� �� -,r'1 �`Y.. r^ zr:,T"�"y 7��. � "R'>*`T':�.F—'a. � :fir � 3) 30 Table P-1 Propane Low Pressure (Standard) Maximum Capacity ofOmegaFlexTrdcPipe CSST in Thousands of BTU per Hour Propane Gas t1Aln Gas Pressure y.1 r 3 i W c* :< Pre�sureDrop <0'S min we �� (Based on a 1.52 Specific Gravity / 2520 BTU per cubic foot Gas) Tubing Length (feet) 1 40 50 60 70 75 81 91 100 125 150 200 250 300 400 500 .11 700 811 900 1000 1100 1200 1300 1400 1500 318" 15 100 71 59 52 46 43 36 33 30 28 27 27 25 24 22 19 17 16 14 13 11 9 9 8 8 8 8 6 6 6 6 1/2:; -19- •.218y �157 ' :, ,t � :. r.. ,, ,i� tc � ;. . r , .. , . , � , :< , 71 128 ... - q 65 59;, 57 46,-.- �3 p; � }: - .: ,.z60 .;.54 . �5'1. 41 ..3 �•�>19 _77 17 76 76 i 1_4 _74 74 s 13 3/4" 25 545 388 318 277 249 226 198 177 161 150 146 141 133 127 112 103 90 81 73 63 57 52 49 464 43 41,. 38 36 35 35 33Ot 663 543.. '.'4Z2i Y tf :. _::.386 � >:336 ,$01-:' ' ; 275 55 247 2 239 225 ' ,$23 , :, -. 219 , J92 a 176 . 152 .136 J25- 108 9Lei 89 -.82 J6fi 73 ,".6 6 1114' 39 1756 1249 1023 888 796 728 632 567 518 480 464 450 424 402 361 329 287 256 234 203 182 166 154 144 136 130 123- 119 114 109 106 4 1997 7626. 1406 1256 885 • 746 Z20;: 697 622 333 ,1145 _.990 ,806 • .657 ,556=r, . 507 :z- 39 _ .3 . ;..,, t. 4 91. 358". 309a 275x 252 217 204 795 185' j77 : 789 163 ' 158: 62 6558 4645 3797 3290 2945 2688 2331 2085 1905 1764 1704 1650 1556 1477 1322 1206 1047 936 855 741 663 605 560 524 494 469 448 429 412 39s: LZ' Tables above include losses for four 90-degree bends and two end fittings. Tubing runs with larger numbers of bends and/or fittings shall be increased by theequivalent length oftubing to the following equatiom n where Lis the additional length of tubing and n Is the number of additional fittings and/or bends. Table P-1A Propane Low Pressure Maximum Capacity ofTracPipeCSST in Thousands of BTU per Hour Propane Gas Min Gas Pressure �P%essureDrop 10' mwu' (Based on a 1.52 Specific Gravity / 2520 BTU per cubic foot Gas) Tubing Length (feet) 15 1138 1100 I 82 I 71 I 65 I 59 I 52 146 I 43 I 40 I 38 136 I 35 I 33 I 30 I 27 I 24 122 I 19 I 17 116 I 14 I 13 I 13 I 11 111 111 I 9 I 9 I 9 I • 9 13/4" 125 1763 1545 1446 1388 1348 1318 1277 1249 1226 1211 1204 1 1981187 I 177 I 158 1146 1127 1112 1103 I 90 181 I 73 I 68 I 63 160 157 154 152 151 149 I 47 1 1/1" 39 12467 11756 11438 11249 111191 1023 1 888 1 796 1 728 1674 1652 1 632 1597 1 567 I 507 1464 1402 1361 1329 1287 1256 1234 1217 1203 1192 1182 1174 1166 1160 1 154 1 149 2" 162 19259 16558 15361 14645 14158 13797 13290 1 2945 1 2688 1 2490 1 2407 1 2331 1 2198 1 2085 1 1867 1 1704 1 1477 1322 1206 1 1047 1 936 1 855 1 792 1 741 1 698 1 663 1 632 1 605 1 581 1 560 541 Notes: EHD (Equivalent Hydraulic Diameter) A theoretical size which reflects the hydraulic performance of the tubing. It Is not a true physical measure. This numberis used to compare Individual sizes between different manufactures The higher the EHD number the greater the now capacity of the piping. Tables above include losses for four 90-0egree bends and two end fittings. Tubing runs with larger numbers of bends and/or fittings shall be increased by the equivalent length of tubing to the following equation: L=i 3n where Lis the additional length of tubing and n is the number of additional fittings and/or bends. E Maximum Capacity of PE Pipe in Thousands of BTU per Hour of Liquefied Petroleum Gas with a Gas Pressure of 11.0 in. WC and a Pressure Drop of 0.5 in. WC (based on a 1.52 specific gravity gas) 187 125 99 84 74 67 56 1073 720 571 484 425 383 26 25 86 257 235 218 204 192 69 152 1391 934 740 627 551 497 421 370 333 305 283 264 249 219 197 1983 1331 1054 893 786 708 600 528 475 435 403 376 354 311 280 3563 2391 1894 1605 1412 1272 1078 948 854 781 723 676 636 560 504 4724 3247 2608 2232 1978 1792 1534 1359 1232 1133 1054 989 934 828 750 10063 6755 5351 4535 3989 3592 3044 2678 2411 2207 2044 1910 1797 1581 1424 22 20 18 15 13 12 11 10 9 q 8 ®®®® 129 113 102 86 76 68 63 58 54 51 48 46 44 42 40 167 147 132 112 99 89 81 75 70 66 63 60 57 54 52 238 209 188 160 140 126 116 107 100 94 89 85 81 78 75 427 376 338 287 252 227 208 192 180 169 160 15.2 146 140 134 642 569 516 441 391 354 326 303 285 269 255 244 233 224 216 1207 1061 956 810 712 642 587 544 508 478 453 431 411 394 379 Maximum Capacity of PE Pipe in Thousands of BTU per Hour of Liquefied Petroleum Gas 516BTUh=1 CFH with a Gas Pressure of 2.0 psi and a Pressure Drop of 1.0 psi (based on a 1.52 specific gravity gas) 1966 1�M 1045 ® 8=86 702 5® • 5® 471—4� 3® 3® 351 ® 11300 7586 6008 5092 4479 4033 3418 3007 2707 2478 2295 2144 2018 170 5 1599 14652 9835 7790 6602 5807 5229 4432 3898 3510 3213 2975 2780 2617 2302 2073 20877 14014 11100 9408 8275 7451 6315 5555 5002 4578 4239 3962 3729 3280 2953 37514 25183 19946 16905 14869 13389 11348 9982 8988 8226 7618 7119 6700 5894 5307 43429 29848 23969 20516 18182 16474 14100 12496 11322 10417 9691 9092 8589 7612 6897 105963 71131 56339 47750 42000 37820 32054 28194 25388 23234 21517 20108 18926 16647 14990 1 236 207 187 158 l�� lr� 1� 15 lii�a�L'� ��e " " 11 11 1� 1355 1192 1073 910 800 720 659 611 571 537 508 484 462 443 425 1757 1545 1391 1179 1037 934 855 792 740 696 659 627 599 574 551 2603 2202 1983 1680 1478 1331 1218 1128 1054 992 939 893 853 818 786 4498 3956 3563 3019 2656 2391 2189 2027 1894 1783 1688 1605 1533 1469 1412 5903 5232 4740 4057 3596 3258 2997 2788 2616 2471 2347 2239 2144 2060 1985 12705 11175 10063 8529 7502 6755 6182 5725 5350 5036 4767 4535 4331 4150 3988 Maximum Capacity of PE Pipe in Thousands of BTU per Hour of Liquefied Petroleum Gas 16BTUh=1CFH with a Gas Pressure of 10.0 psi and a Pressure Drop of 1.0 psi (based on a 1.52 specific gravity gas) 2476 1662 1316 1116 981 884 749 659 593 543 503 470 442 389 350 14234 9555 7568 6414 5642 5080 4306 3787 3410 3121 2890 2701 2542 2236 2014 18455 12388 9812 8316 7315 6587 5583 4910 4422 4047 3747 3502 3296 2899 2611 26296 17652 13981 11849 10423 9385 7954 6997 6300 5766 5340 4990 4697 4131 3720 47252 31720 25123 21293 18729 16865 14294 12572 11321 10361 9595 8967 8440 7423 6685 53960 37087 29782 25489 22591 20469 17519 15527 14068 12943 12041 11297 10671 9458 8569 133476 89601 70967 60148 52905 47640 40376 35514 31980 29267 27104 25329 23840 20970 18882 297 261- 235 199 �� 1707 1501 1352 1146 1008 2213 1946 1753 1485 1306 3153 2773 2497 2116 1862 5665 4983 4487 3803 3345 7334 6500 5890 5041 4468 16004 14077 12676 10743 9449 158 144 134 1-2� l�jg� l�l�WAp 907 830 769 719 676 ' 640 609 1176 1077 997 932 877 830 790 1676 1534 1421 1328 1250 1183 1125 3012 2757 2553 2386 2246 2126 2022 4048 3724 3465 3251 3071 2916 2782 8509 7787 7212 6739 6343 f 6005 5712 Ph: 1.800.662.0208 • Fax: 615.325.9407 • Web: www.gastitg.com 101 97 93 582 557 536 754 723 695 1075 1030 990 1931 1851 1779 2664 2560 2466 5455 5227 5024 2516BTUh=ICFH, (TYPICAL) - -► KINGFISHER -WATERWAY FOUND DRILIHOLE •, (NO IDENTIFICATION) o CONCRETE SEAWALL .r i BRICK PLANTER ^ NCRETE LIGHT PAST S ' CONCRETE WALL in CONCREIE N 9.45 y� � E!K 22'AC !�B Nti n'y STORY RESIDENCE' AN N �p /1,1t� N0.238 = !0.\4��\\� p a d 41 i \ :� .;,CONCERED 20 23. 1 LOT -CONCRETE- I BLOCK3 BLOCKS LOT 5DRIVEWAY.," f FOUND 1/2' IRON ROD S CAP'RLS 2391- 0 , 00' GUY WIRE TELEPHONE PEDISTAL H ASPHALTROAAD - r *• / This Survey is for the benefit of only the following parties: 1) CHRISTOPHER M. WORKMAN 2) EDWARD W. BECHT, PA. 3) OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY ee r Date of Survey: APRIL 25, 2018 PropertyAddress• FOUND DRILLHOLE 238 BIMINI DRIVE :(No IDENTIFICATION) FORT PIERCE, FL. 34949- /,i GmodaBcafiP. LEGEND CAN = CABLE TELEVISION BOX 238 Bimini Dr.'Fart A/C = AIR CONDITIONER Pie— FLS4949 4.• `. R1W = RIGHT OF WAY $. 1, a •. _. - •�ocyr e.cn � =CENTERLINE `�.,, �� ' f �•� r" 3 �• ; = ARC LENGTH W/ 14 R = RADIUSLOCATION MAF`�. D ='CENTRAL ANGLE R. ® = WATER METER DESCRIPTION OHW = OVERHEAD WIRES LOT 5, BLOCK 3, CORAL COVE BEACH, SECTION ONE, ACCORDING TO = WOOD POWER POLE THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 11, PAGE 30A, PUBLIC RECORDS OF SAINT LUCIE COUNTY, FLORIDA. SURVEYOR'S CERTIFICATION This drawing and the prerequisite field survey have been prepared to conform with the applicable Standards of Practice as set forth by the Florida Board of Professional Surveyors and Mappers in Chapter 5J-17, Florida Administrative Code, pursuant to ® 31 q 1 Section 472.027, Florida Statutes and is based on documentary evidence as provided to the undersigned surveyor and existing Q field evidence. This certification is a statement of professional opinion and is not an expressed or implied warranty or guarantee. This survey is for the sole and exclusive benefit of the parties named hereon and for the specific i relied upon by any other individual er entity whatsoever, and is not transferable under any rccmst daces. noted, and or ust not be responsibility is assumed by the undersigned surveyor for any other use of this survey or to any party not specifically named BLOCK 3 a Q Gc.,l)atq ( 17 hereon. This drawing Is not valid without the signature and the original raised embossed seal of the undersigned surveyor and 't(t V nbL r6 r�vn reproduction of this drawing without the written permission of the undersigned surveyor is hereby forbidden. c) -FOUND S/B• IRON ROD SURVEY y NOTES (NO IDENTIFICATION t 7n • + Onv 1. THIS IS A BOUNDARY SURVEY AS DEFINED IN CHAPTER 5J-17 OF THE FLORIDA ADMINISTRATIVE CODE. 2. BEARINGS BASE: N87'00'47°W RELATIVE TO THE CENTERLINE OF BIMINI DRIVE. 3MBJECT PARCEL IS LOCATED IN FLOOD ZONE AE and X, PANEL No.12111 C 0161 J, DATED: 2/6/2012. d. ALL DISTANCES ARE MEASURED UNLESS OTHERWISE NOTED. 5. UNLESS IT BEARS THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LI -0F MAPPER THIS SURVEY IS NOT VALID. CENSED SURVEYOR AND FWND RAILROAD 6. UNDERGROUND IMPROVEMENTS, UTILITIES AND FOUNDATIONS ARE NOT LOCATED UNLESS OTHERWISE NOTE FOUND NAIL (ND IDENRFICATION) 7• ADDITIONS OR DELETIONS TO THE SURVEY MAPS OR REPORT BY OTHER THAN THE SIGNING PARTY OR PARTIES (NO�FlCAA7INTFRSECTION IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. 8. NO SEARCH OF THE PUBLIC RECORDS WAS MADE BY THIS OFFICE. 9. SURVEY BASED ON LEGAL DESCRIPTION PROVIDED BY CLIENT. N87'0847"W 348 72' . 0 e Surveying &Mapping, Inc. 920 920Belvedere Road, Ste 114 Royal Palm Beach, FL 33411 Phone: 561.790.5515 Fax: 561.790.6557 Thomas E. Whidden www.whiddensurveying.com Professional Surveyor and Mapper Licensed Business No. 7232 Florida License No. 6225