Loading...
HomeMy WebLinkAboutPROPANE TANK PAPERWORKSuRaRHM Quality Steel Corporation AG/UG Propane Tanks OVERALL LENGTCLa H /b OVERALL HEIGHT LEG WIDTH �- �1 1411VV . LEG WIDTH 1450 wg. AND UP APPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS WATER CAPACITY DIAMETER (OD) HEAD TYPE OVERALL LENGTH OVERALL HEIGHT LEG* WIDTH LEG** SPACING WEIGHT (lbs.) **QUANTITY FLILLLOAD PERSTACK *120 wg. 24" Ellip. 5'-8" 3' 1'-11/2" 2'-101/2" or 3'-11" 260 108 196 ' 16 1 12 *1250 wg. 30" Hem!. 7'-10" 3'-8" 1 1'-5" 4'41" 480 54 9 *320 wg. 30" Hemi. 9'-7" 3'-8" 1'-5" 5' 620 45 9 $00 wg. 37 1/2" Hemi. 10, 4'-2" 1'-8" 5' 950 37130 8 1 6 1,000 wg. 41" Hemi. 16' 4'-5" 1'-8" 10'-1" 1,800 171 15 6 15 11450 wg. 46 1/2" 1 Ellip. 17'-4" 4'-11" 1'-9" 11'-7" 1 2,650 1 12 4 1,,990 wg. 1 46 1/2" 1 Ellip. 23'-11" 1 4'-11" V-9" 16' 1 3,520 1 8 4 Dimensions and specifications shown are approximate. Individual vessels may vary. I * Leg spacing+/- 2". Leg widths and spacing may vary based on mfg. location. Check with your salesperson for details. 120, 250, 320 wg. standard tanks no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks - 2 holes 16" on center. 1450 wg. and up as shown above. *' jFull load and stack quantities vary by shipping location. Check with your salesperson for details. General Specifications - Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section Vlll, Division 1. I Complies with NFPA 58. - Rated at 250 psig from -20* F to 125* F. All vessels registered with National Board. -Two service options available: Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/UG dome. Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy rimer coat followed b urethane to coat supplied with steel AG/UG dome. � Pp� p YP Y p pP� - All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. i i Updated June 30, 2015 I PROPANE CONSTRUCTION NOTES 1 1. All pipe and fittings above ground and inside building shall be SCH..40 Galvanized ASTM A120 or AGA approved. corrugated stainless steel •(C.S.S.T.) •pipe. ;. 2. All polypipe and fittings shall be ASTM D251.3 orASTM D2517 and shall be buried -outside underground at a depth of 18" with warning tape and tracer wire. -3. All pipe and meter locations are approximate and subject to change.- .4. Ali polypipe shall be joined by heat fusion or approved mechanical . couplings. 5. All"galvanized pipe shall be threaded. 1 6. All. pipe. shall be pressure tested to 20 PSI -for a period of 24 hours. I 1 jy I F1 ir 1 7 ra J 1HEM,�v.-�!1TV�4 OffrAl. e �OVFAAW U W FjNG3, N 1'. NEERING wo a via Witter t .49 fivag loll? 964cdo A UNDERGROUND YANK INSTALLATION "• 2" to G" ' DOWNGRADED AWAY ' FROM DOME .` .• ._.__ .•.�.'— . •WIN. .� f ANODE CABLE •�'',;� ; ;_� SACRIFICIAL ANODE - ; �.�%• • • �..;.•; (MAGNESIUM ti U••}f1 � T i REGULATOR r SRUT GAS OFF AT Q'UfiSIDE VA.I;YE %� .;� N ABOVE GRADE .._.. RISER O ,j ! HARNIIfG TAPE • :,. 1 t RISEt GRAbE/CONCRETE SLEEVE J. ' 44 j� •► • •O . I •'• '•• • s uNOEnano010 tr•aAs coy+ultren SEriY(C6 WN-E t `° • TRACE 11IRE