Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - ROOFINGa zglsbs x .z t' w 'ems ,=v i � �3 4 BCIS Home Log In User Registration Hot Topics i Submit Surcharge Stats & Facts Publications Contact Us BCIs Site Map Links Search FILEA - 1 Product Approv CONCEALED FASTENERS OR AI i ACHMENTS ^;'� >� , USER: Public User ARE THE RESPONSIBILITY OF THE S E P 2 2018 CONTRACTOR OR RECORD Product Approval Menu > Product or App IJ_catlon Search > APp Ieatlon List `aa, .±4 ST. Lucie County, Permitting (\��p Search Criteria 4Y Refine Search /� Code Version 2017 FL# �°.��% 17022.1 Application Type ALL Product Manufacturer coup fa ALL L Category ALL Subcategory ly Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL -FL# Type Manufacturer Validated Status ..... .... ... _.-_... ..... ..g.�...................._.................. ............ ......._..............� ........... .......... FL17022- .................... --....... _ Revision i .........._.._............ .... _.... ...._............ _................._......_.... ...._...._..... ..... .... _..... ..... ._..... _....... _........ _._....... ....._-.._...... _........... ............. -..................... Extreme Metal Fabricators, LLC FL#: FL17022.1 Zachary R. Priest, P.E. Approved i 77 ist ry, Model: 1 - "5V Crimp" (116) (813) 480- Description: 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel 3421 mechanically attached to 15/32" plywood or Wood Deck with fasteners Category: Roofing Subcategory: Metal Roofing �Approveo oy ubFK. Approvais oy UtlrK snap oe rev{eweu anu rauneu uy cne ru� enutur uie winmjeawu 11 no­y. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyraght 2007-2013 State of Florida.:: Pr yacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact B50.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, FS., please click here . Product Approval Accepts: in RhEtfc M CreditCard = secau-i't��1i•r;<>es,. THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. ?C1 ST. COUNTY BUILDING DI ON D F R COURLIANCE � DATE PLANS , D PER IT MUST BE KEPT ON B SITE OR NO INSPECTION(S) WILL �E ADE Cor 3/1 req 160 SW Poma Drive Palm City, FL 34990 _ (772)872-8034 pliant with Florida Building Code 2017 (6" ed.) pliant with Florida Product Approval Rule # 61G20-3 pliant: Keystone Certifications uct: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" ;ion Resistant Compliant: FBC Sec.1507.4.3 ier 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate min. thru deck or 5/8" embedment into wood plank. (*or sufficient, length to meet rements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to `7. eet requirements) Undprlayment: To be compliant with FBC Sec. Chart 1507.1.1 Shall be in compliance with FBC Sec. 1507. Seeasteqer4affaq ent specifications above Install Details: Table A Allowable Loads METHOD 1 / METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" o.c. 16" o.c. 8" O.C. 6" ox FASTENER SPACING (ALONG Panel width) 12" o.c. 12" D.C. 12" o.c. 12" o.c. FASTENER SIZE #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: UL 580-06 & 1897-041 Test Report D05893.01�-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 25-03 Test Report D05893.02-450-18 '07/22/14 *EQ 'VALENCY--UL 1897-04 is equivalent to test standard UL 1897-1*Design pressure margin of safety 2:1 \\��� O. JOY •��/,! Locke Bowden, P.E. does not have, not will acquire a financial in l�ry' � 4V'; qy Y. Wacturing or distributing products under this evaluation. ° Locke 3owden, P.E. is not owned, operated, or controlled by a jA► coaiparNprnAifAturer, or distributing products under this report. a ' r S ', • 4 r� FL17022.1 5V Crimp (2I,- --4 Steel), 24" Wide Roof Panel - L� ,Ails Limitation 1, Linde 2. Minin 3. Prodt 4. Engir 5. Fire c 6. Supp Struc 7. This t iyment to be compliance with current Florida Building Code (FBC)2017 6th ed. m slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. is are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D Bring analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. ssification is not part of this acceptance. Shear diaphragm values are outside this report. t framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for ral Loading. port does not imply warranty, installation, recommended product use outside of this report. — Fasteners - #9 x 1.112" Min. or #10 x 1-1/2" Min. per Table A' for Row Spacing and Design Pressures Hex Washer Head Wood Screws Deck: 15/32" or greater Plywood, or Wood plank 24" iz' 3f8" N*_1''— 4PT1ON4L STRIATIONS Nominal 12" O.C. Panel Profile Nominal 12" O.C. 5-V Crimp Roof Panel il Fasten 9 x 1-1/2" Min, or #10 x 1-1/2" Min, per -Table "A" Hex Washer Head Screw Panel Spaced 12" o,c. across the Panel Width Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or -Wood plank