Loading...
HomeMy WebLinkAboutGENERATOR PAPERWORKINCLUDES: True Power'" Electrical Technology Two Line LCD Multilingual Digital Evolution'"" Controller (English/Spanish/ French/Portuguese) Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. Electronic Governor System Status & Maintenance Interval LED Indicators Sound Attenuated Enclosure Flexible Fuel Line Connector s Direct -To -Dirt Composite Mounting Pad 10 Natural Gas or LP Gas Operation 5 Year Limited Warranty Capability to be installed within 18" (457 mm) of a building* FEATURES • GENERAL' GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine y Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-1. G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Farce series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. 4LISTED)us QUIFT—Tf—ff— Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. 10 TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this ✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. GENERAC _ • • * * Mobil ' I— PROMISE �s.�PP° �q0 Link •aunr m me usa us4ip nnmoenr. ann7mernn vane. GENERAC' 16%20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasma molt' rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. i Generator • evolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation 1 -Regulates the output voltage to ±1 % prevents damaging voltage spikes. • OL 2200 listed For your safety. i Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 313 Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. i Evolution"' Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a i qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • S'mart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System • 1 it (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 9 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. General Information Specifications Generator F7Model 9 kWT 11 kW 16 kW 20 kW 22 kW Rated Voltage 240 Rated Maximum Load — Current (Amps) at Rated 37.5 45.8 66.6 33.3 91.7 Voltage with LP' Main Line Circuit Breaker. (Generator Disconnect) 40 Amp — 50 Amp 70 Amp 00 Amp 100 Amp Phase 1 Rated AC Frequency 60 Hz Battery Requirement 12 volts, Group 26R-540CCA Minimum or Group 35AGM-65OCCA Minimum (Field supplied) (see Replacement Parts) Enclosure Aluminum Weight (lbs/kilos) 340/154 348/158 409/186 448/203 466/211 (Without battery) This unit is tested in accordance to UL 2200 standards with an operating temperature of -20 °F (-29 °C) to 122 °F Normal Operating Range (50 °C). For areas where temperatures fall below 32 °F (0 °C) a cold weather kit is recommended. When operated above 77 °F (25 °C) there may be a decrease in engine power. See Engine. These generators are rated in accordance with UL 2200, Safety Standard for Stationary Engine Generator Assemblies, and CSA-C22.2 No. 100-04 Standard for Motors and Generators. ` Na(ural Gas ratings will depend on specific fuel joules/BTU content. Typical derates are between 10-20% off the LP gas rating. i Engine Model 9 kW 11 kW 16/20/22 kW Type of Engine GH-426 GTH-530 GT-999 Number of Cylinders 1 2 2 Displacement 4266 cc 530 cc 999 cc Cylirj der Block Aluminum w/ cast iron sleeve Recommended Spark Plug See Replacement Parts Spark Plug Gap 0.020 in (0.508 mm) 0.030 in (0.76 mm) 0.040 in (1.02 mm) Valve Clearance 0.002-0.004 in 0.05-0.1 mn1 ( ) 0.002-0.004 in (0.05-0.1 mm) 0.002-0.004 in (0.05-0.1 mm) Starter 12 VDC Oil Capacity Including Filter Approx. '1.1 qt 0.03 L) Approx. 1.7 qt (1.6 L) Approx. 1.9 qt (1.8 L) Recommended Oil Filter See Replacement Parts Recommended Air Filter See Replacement Parts Engine power is subject to and limited by such factors as fuel BTU/joules, ambient temperature and altitude. Engine power decreases about 3.5% for each 1000 ft (304.8 rn) above sea level, and also will decrease about 1 % for each 10 °F (6 `C) above 60 °F (15 °C) ambient temperature. The 'specification sheet for your generator was included in the documentation provided with the unit at the time of purchase. For additional copies, consult your local Independent Authorized Service Dealer (IASD) for your specific generator model. I O',vner'S Manual for 60 Hz Air -Cooled Generators GENERA I C° Service and non -Service rated Automatic Smart Transfer Switches 100 - 400 Amps, Single Phase C @us LISTED��• 'CUL only applies to non -service rated switches Description Gen, erac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'"" or Nexus'"' Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated equipment configuration. Standard Features Service rated (RXSW) General; Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure*, with electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for yeats of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All switches are covered by a 5 year limited warranty. Non -service rated (RXSC) switches are housed in a steel enclosure. DPM Technology Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be managed as well, providing the most installation efficient power management options available. DSO +.,d.. 2008 GENERAC' 100-400 Amps, Single Phase Automatic Smart Transfer Switches Functions All timing and sensing functions originate in the generator controller Utilityvoltage drop -out ..................................... ............................................................................................................. .................................................................... <.65°% Timer to generator start..................................................................................................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer` Enginewarm up delay.................................................................................................................................................................................................................5 seconds Standbyvoltage sensor ............... ............................................................................................................. ............................. ......................................... 65% for 5 seconds Utilityvoltage pickup.........................................................................................................................................................................................................................>80°% Re -transfer time delay...............................................................................................................................................................................................................15 seconds Enginecool -down timer............................................................................................................................................................................................................60 seconds Exerciser..............................................................................................................................................................5 or 12 minutes adjustable weekly/Bi-weekly/Monthly.. The transfer switch can be operated manually without power applied. 'When used in conjunction with units utilizing Evolution'" controls "Adjustable via the controller Specifications Mobel RXSC100A3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW200A3 RXSW300A3 RXSC40OA3 RXSW40OA3 Amps 100 100 150 200 200 300 400 400 Voltage 120/240,lo 120/240,to 120/240,18 120/240,1e 120/240,ta 120/240,1a 120/240,1e 120/240,te Load Transition Type (Automatic) Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Open Transition Service Rated Open Transition Open Transition Service Rated Enclosure Type NEMA/UL 313 NEMA/UL 311 NEMA/UL 3R NEMA/UL 311 NEMA/UL 311 NEMA/UL 3R NEMA/UL 3R NEMA/UL 3R UL Patting UL/CUL UL UL UL/CUL UL UL UL/CUL UL Withstand Rating (Amps) 10,000 10,000 22,000 10,000 22,000 22,000 22,000 22,000 Lugi Range 1/0 - #14 250 MGM - #6 600 MGM - #4 or 1/0 - 250 MGM Dimensions Model RXSC100A3 RXSW100A3 RXSW150A3 RXSC200A3 RXSW200A3 RXSW300A3 RXSC400A3 RXSW400A3 H1 17.24/437.9 17.24/437.9 26.75/679.4 17.24/437.9 26.75/679.4 42,91/1089.9 31.26/793.8 42.91/1089.9 Height (inJinm) H2 20/508 20/508 30/762 20/508 30/762 48/1219.2 36/914.4 48/1219.2 W1 12.5/317.5 12.5/317.5 10.5/266.7 12.5/317.5 10.5/266.7 16.69/423.9 19.18/487.2 16.69/423.9 Width (inJmm) W2 14.6/370.8 14.6/370.8 13.5/342.9 14.6/370.8 13.5/342.9 21.82/554.2 24/609.6 21.82/554.2 Delpth (inJmm) 7.09/180.1 7.09/180.1 6.3/160.1 7.09/180.1 6.3/160.1 10.06/255.5 10.06/255.5 10.06/255.5 weight (lbs./kilos) 20/9.07 22.5/10.21 39/17.69 20/9.07 39/17.69 140/63.5 133/60.33 140/63.5 GEN ERAC Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 10000013459-A 04/24/17 Ht HI