HomeMy WebLinkAboutGENERATOR PAPERWORKINCLUDES:
True Power'" Electrical Technology
Two Line LCD Multilingual Digital
Evolution'"" Controller (English/Spanish/
French/Portuguese)
Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Page 4 for Details.
Electronic Governor
System Status & Maintenance Interval LED
Indicators
Sound Attenuated Enclosure
Flexible Fuel Line Connector
s Direct -To -Dirt Composite Mounting Pad
10 Natural Gas or LP Gas Operation
5 Year Limited Warranty
Capability to be installed within 18" (457 mm)
of a building*
FEATURES
•
GENERAL'
GUARDIAN° SERIES
Residential Standby Generators
Air -Cooled Gas Engine
y Standby Power Rating
Models G007036-0, G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz
Model G007035-0 (Aluminum - Bisque) - 16 kW 60 Hz
Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz
Models G007043-1. G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz
O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O
success in providing the most reliable generators possible. Generac's G-Force engine
lineup offers added peace of mind and reliability for when you need it the most. The
G-Farce series engines are purpose built and designed to handle the rigors of
extended run times in high temperatures and extreme operating conditions.
O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O
form produce less than 5% Total Harmonic Distortion for utility quality power. This allows
confident operation of sensitive electronic equipment and micro -chip based appliances,
such as variable speed HVAC systems.
4LISTED)us
QUIFT—Tf—ff—
Note: CUL certification only applies to unbundled units and units packaged with
limited circuit switches. Units packaged with the Smart Switch are UL certified in
the USA only.
*Only if located away from doors, windows and fresh air intakes,
and unless otherwise directed by local codes.
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
This state-of-the-art power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at ±1 %.
SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
10 TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are
PROTOTYPE TESTED J NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this
✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer
systems and controls for total system compatibility.
GENERAC
_ • • * * Mobil '
I—
PROMISE �s.�PP° �q0 Link
•aunr m me usa us4ip nnmoenr. ann7mernn vane.
GENERAC'
16%20/22 kW
features and benefits
Engine
• Generac G-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasma molt' rings helps the engine
run cooler, reducing oil consumption resulting in longer engine life.
• "Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
• Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur-
ing up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown
Prevents damage due to overheating.
i
Generator
• evolving field
Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
• Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation
Maximizes motor starting capability.
• Automatic voltage regulation
1 -Regulates the output voltage to ±1 % prevents damaging voltage spikes.
• OL 2200 listed
For your safety.
i
Transfer Switch (if applicable)
• Fully automatic
Transfers your vital electrical loads to the energized source of power.
• NEMA 313
Can be installed inside or outside for maximum flexibility.
• Remote mounting
Mounts near your existing distribution panel for simple, low-cost installation.
i
Evolution"' Controls
• Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
• Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
• Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
•
Utility voltage sensing
Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
•
Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
•
Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a
i
qualified dealer.
•
Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
•
Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
•
Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every
other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel
costs to the owner.
•
S'mart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
•
Main line circuit breaker
Protects generator from overload.
•
Electronic governor
Maintains constant 60 Hz frequency.
Unit
•
SAE weather protective enclosure
Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150
mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat-
ically applied textured epoxy paint for added durability.
•
Enclosed critical grade muffler
Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
•
Small, compact, attractive
Makes for an easy, eye appealing installation, as close as 18" away from a building.
Installation System
•
1 it (305 mm) flexible fuel line connector
Absorbs any generator vibration when connected to rigid pipe.
•
Direct -to -dirt composite mounting pad
Complex lattice design prevents settling or sinking of the generator system.
9
Integral sediment trap
Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
General Information
Specifications
Generator
F7Model
9 kWT
11 kW
16 kW
20 kW
22 kW
Rated Voltage
240
Rated Maximum Load
—
Current (Amps) at Rated
37.5
45.8
66.6
33.3
91.7
Voltage with LP'
Main Line Circuit Breaker.
(Generator Disconnect)
40 Amp
—
50 Amp
70 Amp
00 Amp
100 Amp
Phase
1
Rated AC Frequency
60 Hz
Battery Requirement
12 volts, Group 26R-540CCA Minimum or Group 35AGM-65OCCA Minimum
(Field supplied)
(see Replacement Parts)
Enclosure
Aluminum
Weight (lbs/kilos)
340/154
348/158
409/186
448/203
466/211
(Without battery)
This unit is tested in accordance to UL 2200 standards with an operating temperature of -20 °F (-29 °C) to 122 °F
Normal Operating Range
(50 °C). For areas where temperatures fall below 32 °F (0 °C) a cold weather kit is recommended. When operated
above 77 °F (25 °C) there may be a decrease in engine power. See Engine.
These generators are rated in accordance with UL 2200, Safety Standard for Stationary Engine Generator Assemblies, and CSA-C22.2 No. 100-04
Standard for Motors and Generators.
` Na(ural Gas ratings will depend on specific fuel joules/BTU content. Typical derates are between 10-20% off the LP gas rating.
i
Engine
Model
9 kW
11 kW
16/20/22 kW
Type of Engine
GH-426
GTH-530
GT-999
Number of Cylinders
1
2
2
Displacement
4266 cc
530 cc
999 cc
Cylirj der Block
Aluminum w/ cast iron sleeve
Recommended Spark Plug
See Replacement Parts
Spark Plug Gap
0.020 in (0.508 mm)
0.030 in (0.76 mm)
0.040 in (1.02 mm)
Valve Clearance
0.002-0.004 in
0.05-0.1 mn1 ( )
0.002-0.004 in
(0.05-0.1 mm)
0.002-0.004 in
(0.05-0.1 mm)
Starter
12 VDC
Oil Capacity Including Filter
Approx. '1.1 qt 0.03 L)
Approx. 1.7 qt (1.6 L)
Approx. 1.9 qt (1.8 L)
Recommended Oil Filter
See Replacement Parts
Recommended Air Filter
See Replacement Parts
Engine power is subject to and limited by such factors as fuel BTU/joules, ambient temperature and altitude. Engine power decreases about 3.5% for
each 1000 ft (304.8 rn) above sea level, and also will decrease about 1 % for each 10 °F (6 `C) above 60 °F (15 °C) ambient temperature.
The 'specification sheet for your generator was included in the documentation provided with the unit at the time of
purchase. For additional copies, consult your local Independent Authorized Service Dealer (IASD) for your specific
generator model.
I
O',vner'S Manual for 60 Hz Air -Cooled Generators
GENERA I C°
Service and non -Service rated
Automatic Smart Transfer Switches
100 - 400 Amps, Single Phase
C @us
LISTED��•
'CUL only applies to non -service rated switches
Description
Gen, erac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'"" or Nexus'"'
Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and
non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated
equipment configuration.
Standard Features
Service rated (RXSW) General; Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure*, with
electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for
yeats of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All
switches are covered by a 5 year limited warranty.
Non -service rated (RXSC) switches are housed in a steel enclosure.
DPM Technology
Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC
controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to 8 more loads can be
managed as well, providing the most installation efficient power management options available.
DSO
+.,d.. 2008
GENERAC'
100-400 Amps, Single Phase Automatic Smart Transfer Switches
Functions
All timing and sensing functions originate in the generator controller
Utilityvoltage drop -out ..................................... ............................................................................................................. .................................................................... <.65°%
Timer to generator start..................................................................................................10 second factory set, adjustable between 2-1500 seconds by a qualified dealer`
Enginewarm up delay.................................................................................................................................................................................................................5 seconds
Standbyvoltage sensor ............... ............................................................................................................. ............................. ......................................... 65% for 5 seconds
Utilityvoltage pickup.........................................................................................................................................................................................................................>80°%
Re -transfer time delay...............................................................................................................................................................................................................15 seconds
Enginecool -down timer............................................................................................................................................................................................................60 seconds
Exerciser..............................................................................................................................................................5 or 12 minutes adjustable weekly/Bi-weekly/Monthly..
The transfer switch can be operated manually without power applied.
'When used in conjunction with units utilizing Evolution'" controls "Adjustable via the controller
Specifications
Mobel
RXSC100A3
RXSW100A3
RXSW150A3
RXSC200A3
RXSW200A3
RXSW300A3
RXSC40OA3
RXSW40OA3
Amps
100
100
150
200
200
300
400
400
Voltage
120/240,lo
120/240,to
120/240,18
120/240,1e
120/240,ta
120/240,1a
120/240,1e
120/240,te
Load Transition Type
(Automatic)
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Enclosure Type
NEMA/UL 313
NEMA/UL 311
NEMA/UL 3R
NEMA/UL 311
NEMA/UL 311
NEMA/UL 3R
NEMA/UL 3R
NEMA/UL 3R
UL Patting
UL/CUL
UL
UL
UL/CUL
UL
UL
UL/CUL
UL
Withstand Rating
(Amps)
10,000
10,000
22,000
10,000
22,000
22,000
22,000
22,000
Lugi Range
1/0 - #14
250 MGM - #6
600 MGM
- #4 or 1/0 - 250 MGM
Dimensions
Model
RXSC100A3
RXSW100A3
RXSW150A3
RXSC200A3
RXSW200A3
RXSW300A3
RXSC400A3
RXSW400A3
H1
17.24/437.9
17.24/437.9
26.75/679.4
17.24/437.9
26.75/679.4
42,91/1089.9
31.26/793.8
42.91/1089.9
Height
(inJinm)
H2
20/508
20/508
30/762
20/508
30/762
48/1219.2
36/914.4
48/1219.2
W1
12.5/317.5
12.5/317.5
10.5/266.7
12.5/317.5
10.5/266.7
16.69/423.9
19.18/487.2
16.69/423.9
Width
(inJmm)
W2
14.6/370.8
14.6/370.8
13.5/342.9
14.6/370.8
13.5/342.9
21.82/554.2
24/609.6
21.82/554.2
Delpth (inJmm)
7.09/180.1
7.09/180.1
6.3/160.1
7.09/180.1
6.3/160.1
10.06/255.5
10.06/255.5
10.06/255.5
weight (lbs./kilos)
20/9.07
22.5/10.21
39/17.69
20/9.07
39/17.69
140/63.5
133/60.33
140/63.5
GEN ERAC Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com
02017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 10000013459-A 04/24/17
Ht