EV4LUATION REPORT
ICP Adhesives and Sealants, Inc. Evaluation Report 02768.03.06-R8
12 05 NW 44th Street FL6332-R8
Coral Springs, FL 33065 Date of Issuance: 08/08/2008
(888) 774-1419 Revision 8:10/12/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
con, struction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been 6a1A%g,��fRr
compliance with the 6eh Edition (2017) Florida Building Code sections noted herein. "�� ®�
s county
DE tRIPTION: IC AdheslVes,JP lyset® AH-160 St Lucie
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Qui lity Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words `Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INS IECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
1.
2.
3.
4.
5.
Evaluation Report consists of pages 1 through 9.
cared by:
J.M. Nieminen, P.E.
Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 10/12/2017. This does not serve as an
electronically signed document.
'IFICATION OF INDEPENDENCE:
Exterior Research & Design,. LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
u RINI tl ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roof Tile Adhesives
Compliance Statement: ICP Adhesives Polyset® AH-160, as produced by ICP Adhesives and Sealants, Inc., has
demonstrated compliance with the 61h Edition (2017) Florida Building Code through testing in accordance with the
Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of
Use set forth herein.
5�.
STANDARDS:
Sections
1504.2.1.1
REFERENCES:
Enti '
ERD (TST 6049)
ERD (TST 6049)
ICC-ES (EVL2396)
Miami -Dade (CER 1592)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
UL LLC (QUA 9625)
PRODUCT DESCRIPTION:
Property
Overturning resistance
Examination
Static Uplift —SSTD 11
Static Uplift—SSTD 11
20121BC Compliance
HVHZ compliance
Static Uplift —SSTD 11
Static Uplift — SSTD 11
Static Uplift—SSTD 11
Static Uplift — SSTD 11
Static Uplift — SSTD 11
Static Uplift—SSTD 11
Static Uplift —SSTD 11
Static Uplift—SSTD 11
Static Uplift—SSTD 11
Static Uplift—SSTD 11
Static Uplift—SSTD 11
Static Uplift—SSTD 11
Static Uplift—SSTD 11
Static Uplift—SSTD 11
Static Uplift—SSTD 11
Static Uplift—SSTD 11
Static Uplift — SSTD 11
Static Uplift—SSTD 11
Static Uplift — SSTD 11
Quality Assurance
Standard
SSTD 11
Reference
P39740.02.12
P39740.11.13-R1
ESR-1709
17-0322.03
ECM-001-02-01
PFI-006-02-01
PFI-006-02-02
PFI-007-02-01
PFI-008-02-04
PFI-009-02-03
TGRI-001-02-03
TGRI-001-02-03
PFPI-010-02-01
PFPI-011-02-01
PFPI-012-02-01
PFPI-013-02-01
PFPI-014-02-01
ECM-003-02-01
ECM-004-02-01
ECM-005-02-01
ECM-006-02-01
ECM-007-02-01
ECM-008-02-01
Service Confirmation
Year
1997
Date
02/20/2012
01/02/2015
12/01/2016
04/27/2017
09/21/2001
05/09/2005
05/09/2005
10/11/2005
02/21/2006
02/21/2006
10/30/2006
10/30/2006
12/07/2006
12/07/2006
12/07/2006
12/07/2006
12/07/2006
06/13/2008
06/13/2008
06/13/2008
06/13/2008
06/13/2008
06/13/2008
Exp. 06/05/2018
4.1 ICP Adhesives Polyset® AH-160 is a two -component expanding polyurethane roof tile adhesive that is mixed
and dispensed from a dispensing system provided by ICP Adhesives and Sealants, Inc. The components are
available in refillable tanks or disposable cylinders (ICP Adhesives ProPack® 30 & 100).
LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for
permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
Exterior Research and Design, I.I.C.
Cenifimte of Authorization N9503
Evaluation Report 02768.03.06-118
6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset® AH-160, (888) 774-1429 Revision 8:10/12/2017
Page 2 of 9
TRNTY ERR
5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings
of this product and FBC 1505.2.
5.4 ICP Adhesives Polyset° AH-160 can be used with flat, low and high profile tiles or any rigid, discontinuous roof
assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority
Having Jurisdiction.
5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide
Product Approval or approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives
Polyset° AH-160.
5.6 Field tiles, meeting the limitations of FBC 1609.5.3, using ICP Adhesives Polyset® AH-160 are limited to
projects having an Aerodynamic Uplift Moment (M.), determined in accordance with FBC 1609.5.3 or Tables
2A and 26 of FRSA/TRI April 2012 (04-12), not greater than the following Allowable Overturning Moment
values. Refer to Section 10 and ICP Adhesives and Sealants, Inc. published installation instructions for
Adhesive Paddy Placement details.
TABLE 1: FIELD TILES IN ICP ADHESIVES POLYSETO AH-160
ALLOWABLE OVERTURNING MOMENT PERFORMANCE DATA
2 TO I MARGIN OF SAFETYALREADYAPPUED FOR INDEPENDENT (SN6LE OR CONTINUOUS PADDY) PLACEMENT
4 TO 1 MARGIN OFSAFETYALREADYAPPLIED FOR INTERDEPENDENT (TWO PADDY) PLACEMENT
Tile (FBC 1609.5.3)
Adhesive Paddy Placement
Allowable
Overturning
Type
Profile
Moment (ft-lbf)
Independent; Single Paddy, Medium (20-inch, ^30 gram)
60
Clay or
Flat
independent; Single Paddy, Large (2x10-inch, -45 gram)
112
Concrete
Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch at the overlap)
54
Independent; Single Paddy, Medium (2x7-inch, ^30 gram)
39
Clay
Low/
Independent; Single Paddy, Large (WO -inch, -54 gram)
67
te
Concrete
Medium
Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at the overlap)
58
Clay
High
Independent; Single Paddy, Large (2x10-inch, -45 gram)
134
Independent; Single Paddy, Medium (2x7-inch, ^30 gram)
65
Clay
High
Independent; Single Paddy, Large (WO -inch, -63 gram)
109
Concrete
Interdependent; Two Paddy (44-inch on underlayment, 2x4-inch at the overlap)
40
Clay
Barrel
2x10-inch x ^35 gram for pans; 2 @ 1x10-inch x -17 gram for cap
147
Concrete
Barrel
2x10-inch x ^35 gram for pans; 2 @ 1x10-inch x -17 gram for cap
107
Clay
Cap atop 2x
Independent: Continuous Paddy ('"34 gram/ft)
135
stringer
Concrete
Cap atop 2x
Independent: Continuous Paddy ('" 34 gram/ft)
116
stringer
Clay
Cap atop 2x
Interdependent:
105
stringer
Head: One (1) #10 x 2%" screw; Overlap: 1 x 6 inch (-10.5 gram)
Concrete
Cap atop 2x
Interdependent:
76
stringer
Head: One (1) #10 x 2Yz" screw; Overlap: 1 x 6 inch (-10.5 gram)
5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April
2012 (04-12). Alternate underlayment systems include those having a current Florida Statewide Product
Approval and/or approved on a local -level by the Authority Having Jurisdiction specifically for use with ICP
Adhesives Polyset® AH-160.
5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with
ICP Adhesives Polyset® AH-160 shall be tested in accordance with SSTD 11 or Testing Application Standard
TAS 101. For the interdependent two -paddy method, an additional 2-to-1 margin above that specified in
SSTD 11 or Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning
moment'.
Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8
CertTicate afAuthorization #9503 6M EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-RS
ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8: 20/12/2017
Page 3 of 9
l
5.7 Hip and ridge tiles using ICP Adhesives Polyset® AH-160 are limited to projects having hip/ridge design pressure
requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the
following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive
Paddv Placement details.
TABLE 2: HIP & RIDGE TILES IN ICP ADHESIVES POLYSET® AH-160'
ALLOWABLE UPLIFT RESISTANCE PERFORMANCE DATA
2 TO 1 MARGIN OF SAFETYALREADYAPPLIED FOR INDEPENDENT (CONTINUOUS PADDY) PLACEMENT
4 TO 1 MARGIN OFSAFErYALREADYAPPLIED FOR INTERDEPENDENT PLACEMENT
Allowable
Tile
Substrate
Attachment Method
Design Pressure
(psf)
Clay
2x PT ridge board
Independent: Continuous Paddy (^-34 gram/ft)
116
Concrete
2x PT ridge board
Independent: Continuous Paddy ("- 34 gram/ft)
107
Interdependent: Head: One (1) #10 x 2%" screw;
90
Clay
2x PT ridge board
Overlap: 1 x 6 inch (-10.5 gram)
Interdependent: Head: One (1) #10 x 2%2' screw;
56
Concrete
2x PT ridge board
Overlap: 1 x 6 inch (-10.5 gram)
Clay or
Hip & Ridge Channel Metal (FL5374):
Independent: Continuous Paddy (- g 34 ram/ft)
169
Concrete
galvanized only
Clay or
Trim LockTM' (FL5374): aluminum,
Independent: Continuous Paddy (-34 gram/ft)
173
Concrete
galvanized, Galvalume® or stainless steel
Clay or
Trim LockTM Plus (FL5374): aluminum,
Independent: Continuous Paddy 34 gram/ft)
178
Concrete
galvanized, Galvalume® or stainless steel
Clay
Top Notch (FL8095)
Independent: Continuous Paddy (^ 32 gram/ft)
125
Concrete
Top Notch (FL8095)
Independent: Continuous Paddy (^ 32 gram/ft)
146
INSTALLATION:
6.1 ICP Adhesives Polyset® AH-160 and the tile roof assembly shall be installed in accordance with FRSA/TRI
April 2012 (04-12) and ICP Adhesives and Sealants, Inc. published installation instructions, subject to the
limitations outlined in Section 5.
6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12).
Proprietary hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product
Approval.
6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by ICP
Adhesives and Sealants, Inc.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the
installation of this product.
81 MANUFACTURING PLANTS:
Tomball, TX
91 QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (847) 664-3623; LeAnna.Gradecki@ul.com
I
I
ExtCrior Research and Design, LLC.
Cea9503
6T" EDITION (2017) FBC NON-HVHZ EVALUATION
ICP Adhesives Polyset® AH-160; (888) 774-1429
Evaluation Report 02765.03.06-R8
FL6332-R8
Revision 8:10/12/2017
Page 4 of 9
TRINTYER®
10. PADDY PLACEMENT DETAILS (FROM ICP ADHESIVES AND SEALANTS, INC. PUBLISHED LITERATURE):
I
10.1 Independent, Medium Paddy:
Nail through plastic cement
(when required), j
Underlayment :d
Paddy (Beneath Tile)
�1
1
Battens optional
Eave Course
\ � / Fascia
`rr2 inn,
I Eave Closure-
Flat/Low Profile Tile
Nail through plastic cement
(when required)
( Y� Paddy (Beneath Tile)
Underlayment
+
7 in k �`_zz7ti� i �\
: in
f'
2 .
Battens optional
<.. loin:- �` 21n.
�•-! Eave Closure
Eave Course " �_::"%� Fascia
Medium Profile Tile
Nail through plastic cerrent--
(when required) Paddy (Beneath Tile)
i
Underlayment�,�
2 in. \ "-
Battens optional
Ie
v EaveCourse�
'P
1 o7i.�%2in.
Fasci
Weephole
.'� Eave closure
% Drip edge
High Profile Tile
Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-118
Certificate o¢Authorization #9S03 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-RB
ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8: 10/12/2017
Page 5 of 9
10.2 Independent, Large Paddy:
Nail through plastic cement Paddy (Beneath Tile)
(when required)., j
Underlayment �d
10 in.
Battens optional
Eave Course�,
.-� � -•� �/ Fasda
Eave Closure
riCWL.VVV rl c,e ,uv
I
Ext? rlor Research and Design, LLC.
Ce fcote of Authorization #9503
Nail through plastic cernent
(when required)
:ol - -- Padcly (Beneath Tile)
Underlayment
2in. wide
Battens optional r"
2in�l�*
Eave Closure
Eave Course' �'^'' �'r Fascia
Medium Profile Tile
Nail through plastic certrene-N
(when required) Paddy (BeneathT(le)
I
Underlayment /
t>
Battens \ .1
optional
tr Eave Course
Fascia
Vveephole
f f - Eave closure
10 in'- 2 in- Drip edge
High Profile Tile
e EDITION (2017) FBC NON-HVHZ EVALUATION
ICP Adhesives Polyset® AH-160; (888) 774-1419
Evaluation Report 02768.03.06-R8
FL6332-R8
Revision 8:10/12/2017
Page 6 of 9
l n.-; Interdependent. Two PaddT.
Nail through plastic cement Paddy (between tiles)
twhen required)
Battens optional"'A t
a PadJy(undertile)
y ; Single paddy \d
\\' on top of tile
Single paddp` 1) ',
under the \
Singlepaddy \ `i
on underlayment 2 x 4 in.
loin` j 'fascia
Eave Closure
cr..an —, 0-4r1e TH.
I
Exterior Research and Design, I.I.C.
Cer I tificate of Authorization #9503
I
I
Hail through plastic cement Single paddy under tile
(when required)
/ Paddy (between tiles)
Battens j: Paddy (under tile)
optional
/ Smgle
on top of tile.:��
y4 x 4 in.
Single naddv on f
underlayment�� �i \
Eave Couure
Eave Closure
/ Fascia
Medium Profile Tile
Hail through plastic cerem ,` Single paddy under tile
(when required) ;
Paddy (between tiles)
e/ r
Battens �' , ' . ` paddy (under tile)
optional
Y ' 'Single paddy �' r
r' onunderlaymeni>,
Single 2x4in.
paddy on
top of tile'—
' }-
Eave Course —; > 1 Y /.
i '" Fascia
Weephole
�y Eave closure
10 in.\
��� Drip edge
High ProfileTile
6T" EDITION (2017) FBC NON-HVHZ EVALUATION
ICP Adhesives Polyset® AH-160; (888) 774-1419
Evaluation Report 02768.03.06-118
FL6332-RB
Revision 8:10/12/2017
Page 7of9
TRINITY ER®
10.4 Two Piece Barrel (Cap & Pan) Tile:
i) Place enough adhesive to achieve 65 to 70 sq.in. Steep pitch applications
in contact with thepan tile. (when required)
2) Tom Covers upside down. Place ndhesivo
112 in. to I Inch in from outside ed0o of cover tile.
Inclail cover tile.
Ensure 20 to 25 sq. in, contact area on
each side of cover tile.
Underlayment
1�
-Sheathing
• tom,
Eave closure
(motar shown)
Weephole Fascia Board
Remove top portion of the eave course cover tile.Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at eave line.
Two Piece Barrel - High Profile Tile
10.5 Hip and Ridge (independent placement):
A hrnd ofICP Poh,111 AII• Inu Tnat be apptcd :dx+m• lhr- li•61 "to att:ah ILp!ritlecfiba. a brad of ICP NO, T.Al:All• I etlua;.
til::ml:ace ou ba!h 5:t:C3 a t$C hip ude: b.=J of gal, LLfdJ 1,,• vppLrd do++n Ih - center of the hilmulu 1hmr.l ar ❑ahTn:r,•,1 be:d l?•d rf. ,: d:e 5il 1,�.•h'1 6, elt-A-; r * r.:hc �::inr ,g' in•hr5 cm
I 1.d haor. to profidr r: r:uhrlbloc6m: Inure. :ur.-.a-d,f,:-
Exti erior Research and Design, I.I.C.
Cer r,tiffcate of Authorization #9503
6T" EDITION (2017) FBC NON-HVHZ EVALUATION
ICP Adhesives PolVset® AH-160; (888) 774-1419
Evaluation Report 02768.03.06-R8
FL6332-R8
Revision 8:10/12/2017
Page 8 of 9
TRINTY ER®
10.6 Hip and Ridge (interdependent placement):
1" X 6" Bead of ICP
..
PolysetOAH-160
roof tile adhesive
_
#10 x 2-1/2" Screw
Code Approved
i
-y.
Fastener
Adhere starter
:p
tile with a 2" x 7"
Paddy placed 3"
r;
down from head
r
of the
W
x.
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-R8
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL6332-R8
ICP Adhesives Polyset® AH-160; (888) 774-1419 Revision 8:10/12/2017
Page 9 of 9