Loading...
HomeMy WebLinkAboutNOA - 24GA STEEL PANEL OVER PLYWOOD DECK-r MIIAM IM bE o.I'. DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 (NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Extreme Metal Fabricators, L SCANNED 2160 Poma Drive 'PILE COPY BY Palm City, FL 34990 S$ Lucie County SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code j including the High Velocity Hurricane Zone of the Florida Building Code. CONCEALED FASTENERS OR AI IACiHMENTS ARE THE RESPONSIBILITY OF THE DESCRIPTION: DMC 175 S-24GA Steel Panel over Plywood deck CONTRACTOR OR RECORD i LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. i RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change � in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Buildingl+01PNS AND ALL RrtC3s'CS:cLU11^vK This NOA consists of pages 1 through 5. ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT The submitted documentation was reviewed by Gaspar J Rodriguez. MAY BE NECESSARY IN ODDER TO COMPLY WITH ALL APPLICABLE CODES. vc�t5 NOA No.: 15-0309.06 MIAMI•DADE COUNTY (� Ex iratjon Date: 09/17/20 Approval Date:09/17/15 ST. LUCIE COUNTY BUILDING DJ ION 9707:m Page 1 of 5 REVIEWED FOR CQWMPLIANCF,. I iA DATE PLAN AND E MIT MUST BE KEPT N OB SITE OR NO INSPECTION'(S) WILL MADE i ROOFING SYSTEM APPROVAL: Category: Roofing Sub -Category: Metal, Panels (Non -Structural) Material: Steel Deck Type: Wood Maximum Design Pressure -121.75 PSF TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: iTest Product Product Dimensions Specifications Description PMC 175 S — 24GA Length: various TAS 110 Corrosion resistant, galvanized steel or Steel Panel Height: 1 5/8" galvalume metal panel. Width: 18" i Thickness 24GA Min Yield Strength: 49 KSI. Snap Lock Clip Length: 3-3/4" Corrosion resistant, 18 gauge steel clip. Height: 1-7/8" Width: 2" Thickness 18GA EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Akzo Nobel Coatings, Inc. Lab Form ASTM G 153 PRI Asphalt Technologies, Inc. AKZC-001-02-01 ASTM B 117 10/08/02 AKZC-001-02-02 AKZC-001-02-03 AKZC-001-02-04 AKZC-001-02-05 iPRI Asphalt Technologies, Inc. DMC-002-02-01 TAS 100 07/23/07 Hurricane Test Laboratory, Inc. 0287-0706-07 TAS 125 09/28/07 MIAMI-DADE COUNTY • Tel I NOA No.: 15-0309.06 Expiration Date: 09/17/20 Approval Date:09/17/15 Page 2 of 5 APPROVED ASSEMBLIES: ISystem: Snap Lock Panel 24GA 18" wide IDeck Type: Wood, Non -insulated Deck Description: New Construction 19/32" or greater plywood or wood plank. Slope Range: 2": 12" or greater Maximum Uplift See Table A below Pressure: Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d annular ring shank nails spaced 6" OC. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32") the above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12 gauge 1 ''/4" annular ring -shank nails, spaced 6" OC at all laps and two staggered rows 12" OC in the field of the roll or any approved underlayment having a current NOA. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in DMC Association of Regional Manufacturers Installation Manual. Metal Panels and Install the "Snap Lock 24GA Steel Metal Panel" panels including flashing penetrations, Accessories: valleys, end laps and accessories in compliance "DMC Association of Regional Manufacturers" current, published installation instructions and in compliance with the minimum requirements detailed in Roofing Application Standard RAS 133. Panels shall be secured along the male rib with approved clips and two corrosion resistant #10 pancake head fasteners of sufficient length to penetrate through the sheathing a minimum of 3/16'. The panel clips were placed at a spacing listed in Table A below starting 3" from panel end. The female rib of panel is snapped over the male rib of panel. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner' Maximum Design Pressures -84.25 PSF -121.75 PSF Maximum Clip S ac ng 16" OC 8" OC 1. Extrapolation shall not be allowed NOA No.: 15-0309.06 Expiration Date: 09/17/20 Approval Date:09/17/15 Page 3 of 5 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133 14. All panels shall be permanently labeled with the manufacturer's name and/or logo, city and state, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 6. Panels may be jobsite roll formed with machine model #0290414; 3381213; 4260215; 5960197; 10811107, from DMC Association of Regional Manufacturers. NOA No.: 15-0309.06 MIAMI-DAoe couNTr Expiration Date: 09/17/20 Approval Date:09/17/15 Page 4 of 5 1-7/8" PROFILE DRAWINGS 1811 1I 1-5/8" PANEL 1.25 -, 1 1 1.125" CLIP END OF THIS ACCEPTANCE NOA No.: 15-0309.06 Expiration Date: 09/17/20 Approval Date:09/17/15 Page 5 of 5