is NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
;umentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
:d in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
is NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
duct or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
inner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
Spend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
luirements of the applicable building code.
its product is approved as described herein, and has been designed to comply with the Florida Building Code
,luding the High Velocity Hurricane Zone of the Florida Building Code.
: Plantation Roof Tile
1G: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
"Miami -Dade County Product Control Approved", unless otherwise noted herein.
ENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
the applicable building code negatively affecting the performance of this product.
ZRMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
aerials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
this NOA shall be cause for termination and removal of NOA.
DVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
piration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
its entirety.
'ECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
be available for inspection at the job site at the request of the Building Official.
NOA renews NOA #14-1120.04 and consists of pages 1 through 7.
submitted documentation was reviewed by Gaspar J Rodriguez.
NOA No:: 15-0721.04
Expiration Date: 12/08/20
Approval Date: 11/05/15
Page 1 of 7
ram,
IOFING ASSEMBLY APPROVAL
:egory: Roofing
i-Category: Roofing Tiles
terial: Concrete
1 j PRODUCT DESCRIPTION
_Manufactured by Dimensions
Applicant
11 ntation Tile Length: 16%2'
Width: 13"
Trim Pieces L = varies
W = varies
Varying thickness
i
21. MANUFACTURING LOCATION
1. Okeechobee, FL
ii.2 SUBMITTED EVIDENCE:
Test
Product
Specifications
Description
TAS 112
Flat concrete roof tile for direct deck or
battened nail -on, mortar or adhesive set
applications.
TAS 112
Accessory trim, concrete roof pieces for
use at hips, rakes, ridges and valley
terminations. Manufactured for each tile
profile.
Test Agency
Test Identifier
Test Name/Report
Date
American Test Lab of South
RT0624.05-14
TAS 112
07/03/14
Florida
i
Redland Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
PA 102 & PA 102(A)
The Center for Applied
94-060B
Static Uplift Testing
March, 1994
Engineering, Inc.
94-084
PA 101 (Adhesive Set)
May 1994
(Mortar Set)
�Iedland Technologies
7161-03
Wind Tunnel Testing
Dec. 1991
Appendix II
PA 108 (Nail -On)
Redland Technologies
Letter Dated Aug. 1, 1994
Wind Tunnel Testing
Aug. 1994
PA 108 (Nail -On)
Redland Technologies
P0631-01
Wind Tunnel Testing
July 1994
PA 108 (Mortar Set)
Redland Technologies
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
The Center -for Applied
Project No. 307025
Wind Driven Rain
Oct. 1994
Engineering, Inc.
Test #MDC-76
PA 100
1Valker Engineering, Inc.
Calculations
Aerodynamic Multiplier
March 1999
April 1999
�Nalker Engineering, Inc.
Calculations
25-7183
March 1995
25-7094
February 1996
25-7496
April 1996
NOA No.: 15-0721.04
MAM4DADE COUN7Y
Expiration
Date:12/08/20
Approval Date: 11/05/15
Page 2 of 7
SUBMITTED EVIDENCE:
Test Agency
Engineering, Inc.
Engineering, Inc.
igh Engineering and
Inc.
Igh Engineering and
Inc.
igh Engineering and
Inc.
Test Identifier
Test Name/Renort
Date
Calculations
25-7584
December 1996
25-7804b-8
25-7804-4 & 5
25-7848-6
Calculations
Two Patty Adhesive Set System
April 1999
T295.11
TAS-108
10/05/11
T306-11
TAS-108
10/04/11
T279-11
TAS-108
09/23/11
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix W. Such testing shall be submitted to the Miami -Dade Product
Control office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4..1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61 G20-3 of the Florida Administrative Code.
I
MIAMI-DADS COUNTY
I
NOA No.: 15-0721.04
Expiration Date:12/08/20
Approval Date: 11/05/15
Page 3 of 7
v
INSTALLATION
4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application
Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (Ibf)
Length-[ (ft)
Width-w (ft)
Plantation
Tile
11.6
1,375
1.08
Table 2: Aerodynamic Multipliers - 1 (0)
Tile
Profile
;L (ft3)
Batten Application
X (ft3)
Direct Deck Application
Plantation
Tile
0.267
0.289
Table 3: Restoring
Moments due to Gravity - M (ft-Ibf)
lie
Greater than
ofile
2"• 12"
3". 12"
• 12"
IV:
SIN: 12"
V., 12"
7"• 12"
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Deck
Deck
Deck
Deck
Deck
Deck
Plantation
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Tile
I
I
MFAMt•DADB COUNTY
,...1 1
NOA No.:15-0721.04
Expiration Date: 12/08/20
Approval Date: 11/05/15
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-lbf)
For Nall -On Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Battens
Profile
(Min 15132"
(Min.19132"
plywood)
plywood)
Plantation Tile
2-10d Ring Shank
30.9
38.1
17.2
Nails
1-10d Smooth or
7.3
9.8
4.9
Screw Shank Nail
2-10d Smooth or
14.0
18.8
7.4
Screw Shank Nails
1 #8 Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
l
1=10d Smooth or
24.3
24.3
24.2
Screw Shank Nail
Field Clip)
1-10d Smooth or
19.0
19.0
22.1
Screw Shank Nail
Eave Clip)
2-10d Smooth or
35.5
35.5
34.8
Screw Shank Nails
Field Clip)
2-10d Smooth or
31.9
31.9
32.2
Screw Shank Nails
Eave Clip)
2-10d Ring Shank
50.3
65.5
48.3
Nails'
1 Installation with a N' the
headlap and fasteners are located a minimum of 2W from the head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mr (ft-lbf)
For Two Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment
Resistance
Plantation
Tile
Adhesive
31.33
2
See manufactures component approval for installation requirements.
3
Flexible Products Company TileBond Average weights per patty 13.9 grams.
3M- 2-Component Foam Roof Tile Adhesive Ali-160. Average weight pera 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
For Single Patty Adhesive Set S stems
Tile Profile
Tile Application
Minimum Attachment Resistance
Plantation Tile
3M'° 2-Component Foam Roof Tile Adhesive AH-160
118.94
3M'" 2-Component Foam Roof Tile Adhesive AH-160
40.46
4 I Lame r)addy placement of 45 grams of W" 2-Component Foam Roof Tile Adhesive AH-160
5 ! Medium � addy placement of 24 grams of Wm 2-Component Foam Roof Tile Adhesive AH-160.
MIAMI-DADE COUNTY
NOA No.: 15-0721.04
Expiration Date:12/08/20
Approval Date: 11/05/15
Page 5 of 7
Table 7: Attachment Resistance Expressed as a Moment - Mi(ft-lbf)
for Mortar Set Systems
Tile Profile
Tile Application
Attachment
Resistance
Seespecific mortar manufacturer's Notice of Acceptance.
51 LABELING
A11 tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
OR
v.�7ENTEGRA v.�7
PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
61. Bun DING PERMIT REQUIRm—PNTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
MIAMI•DADE COUNTY
i
NOA No.: 15-0721,04
Expiration Date:12108/20
Approval Date: 11/05/15
Page 6 of 7
PROFILE DRAWING
PLANTATION FLAT CONCRETE TILE
END OF THIS ACCEPTANCE