Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - ROOFINGun/as C t Meta/ Value Engineered Metal Roofing FLORIDA, PRODUCT APPROVAL SCANNED, Product Evaluation Report. BY S$ Lucie County 1.0 Nail Strip/SnopLock Seam Roof Parcel over 15132" Plywood Florida Product Approval # 21423.8 Florida Building Code 2017 6th ed Per Rule 61G20-3 Method: 1—D Category: Roofing Subcategory: Metal Roofing.Compliance Method: Rule 61G20-3 HVHZ Product Manufacturer: Sunlast Metal 2120SW 'Poma Drive Palm City, Florida 34990 Engineer Evaluator .Mane G. Marotta, P.E. FL reg # 82591 1915 NE 45eiST. #107 Fort Lauderdale, FL 33308 954.776-8004 Validator: Locke Bowden, P.E., FL H49704 9450Alysbury Place Montgomery, AL 36117 Diane G. Marotta, P.E. FL reg # 82591 seal ```�tunnrn:rtrrr, ti✓.uVI ��•'• Cr10 �l.• ` ID Page 1 of 4 , ce Statement: The product as described in this report has demonstrated compliance with the Building Code 2017, Sections 1504.3.2, 1507.1.1, 1507.4.3, 1518.9, 1523.6.5.2.4 Product Description: 24GA Panel,16" Nail Strip/snap lock mechanical attached 16" Coverage Width Roof panels 1.0" Rib height Panel thru fastened; into 15/32" APA Plywood decking. Non-structural Application. FOR USE IN HVHZ. Material: 24GA Steel, Galvalume conforming to Florida Building Code 2017 Section 1507.4.3 56ksi Iield strength min. Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3 and Section 1517 for HVHZ #10 X 1" Pancake -Head wood fasteners or equivalent. 3/16" minimum penetration through support. Corrosion Per Florida Building Code 2017, Section 1506.6, 1507.4.4 I Sealant: Bostick Chem Calk 915 (Silyl modified polymer (SMP) apply 1/16" bead atop rear leg of male joint, adjacent to fasteners continuously along entire length of panel. 15/32�' APA plywood, plywood supports at maximum 24' O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017 and RAS 133. TABLE A Safety factor of 2:1 included Design Pressures Field Perimeter/Corner Max Design Pressure-84.25psf -136.75psf Fastener Spacing 12" o.c. 6" o.c. Fastener Size #10 # 10 I Insulation: Optional Rigid Insulation board, 3" max thickness compliant with FBC 2017 section 1508.2 Quality !Assurance: In accordance with FBC 2017 and Rule # 61620-3: Keystone Certification, Inc. QUA 1824 Test References: Hurricane Test Laboratory (TST1527) 0412-0306-06 RATAS 125-2003 Architectural Testing Inc (TST 1527) # 0412-1203-07 and 0412-0621-07 TAS 125-2003 Architectural Testing Inc. (TST 1527) C6413.01-450-18 REV 1 TAS 125-2003 PRI Construction Material Technologies(TST5878) SFMS-002-02-01 R1 TAS 100-1995 PRI Construction Material Technologies(TST5878) AKZC-001-02-01/05 ASTM B 117-2002 PRI Construction Material Technologies(TST5878) AKZC-001-02-01/05 TAS 110-2000 A O Nobel Coatings, Inc. Lab Form ASTM G 153 Code Compliance: The product described herein demonstrated compliance with The Florida Building Code (FBC) 2017 Section 1504.31.2.,1523.6.5.2.4.1. The product evaluation is limited to compliance with the structural wind load requirements of the FBC 2017, as relates to Rule 61G20-3. Minim m Slope Range 2/12 Minimum Slope per Florida Building Code 2017, and in accordance with Manufacturers recomT endations. Installation: Install per manufacturer's recommended details in compliance with FBC 2017 and RAS 133 i Underl�yment: Per Manufacturer's installation guidelines per Florida Building Code 2017, Chapter 1507 Chart 1507.1.1 Roof Pa�el Fire Classification: No classification. I Shear Diaphragm: values are outside the scope of this report. i Page 2 of 4 I Design Procedure: Based on the dimensions of the structure, applicable wind loads are determined using Chapter 16 of the Florida Building Code 2017 -roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. Design professional shall select the applicable erection details to reference in drawings for correct fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be complia1 t with Florida Building Code 2017 Chapter 22 for steel, Chapter 23 for wood and Chapter 16 for structural loading. Required wind loads shall be determined per project per FBC 2017 and any rational analysis computation shall be prepared by a licensedldesign professional. Certificate of Independence: Diane G. Marotta, P.E. does not have nor will acquire financial interest in any company manufacturing or distributing products under this evaluation. Diane G. Marotta, P.E. is not owned or operated or controlled by any company manufacturing or distributing product under this report. PRODUCT EVALUATION REPORT Page 3 of 4 unlast Metal Value Engineered Meta/ Roofing Tm 'FLORIDA PRODUCT APPROVAL TABLE A #10 X V Pancake -Head wood fasteners or equivalent. 3/16" minimum penetration through support Roof Areas Field Perimeters and Corners Maximum Design Pressures -84.25psf -136.75 psf Screw Spacing 12" o,c, 6" o.c. INSTALLATION METHOD DRAWINGS TYPICAL ASSEMBLY PROFILE VIEW 16" Coverage Striations Optional TYPICAL ASSEMBLY ISOMETRIC VIEW Bead of Bostlk JI Chem -Caulk 915 adhesive Fastener Spacing as per Table A herein Page 4 of 4