HomeMy WebLinkAboutPRODUCT APPROVAL - 1 INCH NAILSTRIPL
Palm City, FL 34990
Compliant with Florida'Building Code 2017 (fith ed.)
Compliant with Florida Product Approval Rule# 61G20-3 aletb
Compliant: Keystone Certifications We c®L,ro,
Pro�uct: 1" Nailstrip 26GA Steel Standing Seam Roof Panel FBC Sec.1507.4.2
Yield strength 40ksi: Attached to Wood Deck with screws.
16" Coverage
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener for Method 1 Attachment # 10 x 1" Pancake Head wood screw to penetrate
3/16" thru 15/32" min. plywood deck
Sean :Adhesive:. Bostik Chem Chalk 915, one component, polyurethane adhesive
along male flange the full ength of panel.
UndIerlayment: To be compliant with FBC Sec.1507
Slope: Shall be in compliance with FBC Sec.1507. 1.1
_.
Install Details: Table.A Allowable Loads METHOD 1 main field METHOD 2 perimeter
DESIGN ,PRESSURE* 69.25PSF 121.75 PSF
FASTENER SPACING -ALONG ROWS 6" O.C. 6" O.C.
EISIVE:. I NOT REQUIRED
Reference Data: HURRICANE TEST LABORATORY, L.L.C. #fTST ID:
o rt #:0223-0313-02 TAS1.26-03(UL 58o-o6luL 9897-o4l)
ort#: 0223-1015-06 TAS125-03(UL 58o-o6luL 9897-o4l)
VALENCY: UL 2897.04 IS EQUIVALENTTO UL 289722 TEST STANDARD *DES)
Locke Bowden, P.E. does not have, not will acquire a financial interest inoany,
under this evaluation. �g� 0
c .L
Locke Bowden, P.E. is not owned, operated, -or controlled by any`an
v , J v4"®
p IR , � •
> x^. •
BEAD (refer to
MARGIN OFSAFETY2.9
ufacturing or distributing products
7
products under this
S
FL 20378.2 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
Limitations:
1. Undelayment to be compliance with current Florida Building Code (FBC)2017 61h ed..
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference.
3. Prodcts are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.