Loading...
HomeMy WebLinkAboutGRID TIED SOLAR POWER SYSTEM 10-3-18i DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE -LINE DIAGRAM PV-4 SAFETY LABELS PV-5 ATTACHMENT PLAN PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN MODULE DATASHEET X OPTIMIZER DATASHEET INVERTER DATASHEET z w MOUNTING SYSTEM DATASHEET SMOUNTING SYSTEM ENGINEERING LETTER UL 2703 GROUND AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY OWNER COVETSKIE PROPERTY ADDRESS 308 SE CAMINO CT, PORT ST. LUCIE, FL 34952 US APN ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE -OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ UTILITY COMPANY FLORIDA POWER& LIGHT CO ELECTRICAL CODE 2014 NEC (NFPA 70) FIRE CODE 2015 NFPA 1 CONTRACTOR INFORMATION COMPANY BAY AREA PROJECT SOLUTIONS LICENSE NUMBER ADDRESS 2512 BAY FIELD CT, HOLIDAY, FL 34691 PHONE NUMBER (727) 543-8361 CONTRACTOR SIGNATURE RECEIVED SIDANNED By Luse County I Q 3 2018 SCOPE OF WORK P-98269 • COUIIt yi Permittin g �,fn„ ..,, THIS PROJECT INVOLVES THE INSTALLATION OF SOLAR PANELS. THE SOLAR PANELS WILL BE RACKED USING A PREENGINEERED RACKING SYSTEM. THE RACKED MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER _> • INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY ` "i USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. C� THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH t �' ',,,'•` - r ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT .... ,, .} SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR -... FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS ,- LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL S APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. �tw•s daM �,eEF+.6 Gtazxl*i 1 PLOT PV-1 SCALE:NTS 2 LOCALE PV-1 SCALE: NTS SYSTEM DETAILS DESCRIPTION NEW GRID -INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE DC RATING OF SYSTEM 8,850W AC RATING OF SYSTEM 7,600W AC OUTPUT CURRENT 32.0A INVERTER(S) 1 X SOLAR EDGE SE760OH-US MODULE JINKO JKM295M-60 ARRAY WIRING (2) STRINGS OF 15 INTERCONNECTION DETAILS POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECTION PER NEC 705.12(A) UTILITY SERVICE 1201240V 10 SOLAR DISCONNECT EATON DG222NRB , 2-POLE, 60A, 240VAC SITE DETAILS ASHRAE EXTREME LOW 0°C (32°F) ASHRAE 21% HIGH 33'C (91-F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORT (KVRB) WIND SPEED RISKCATEGORY II WIND EXPOSURE CATEGORY GROUND SNOW LOAD W f— T- U m flr� W U c') J L.L �S &5 Z W 0 w W U Q J Y C� J U) i,­ ♦—U) co cf) cl O O M H U O elf PROJECT l� PV-1 P-98269 (, h W ��yy//�� W Lo U m e ° d Vi Z F M ,s of W U rs Y ° LLI 0 J O LL s� n x: Z t t O Lu LL ` Q y " Of LU Q YLu J O U) ~ (N)PROPOSED ROOF -MOUNTED PHOTOVOLTAIC ARRAY. 8:12 SLOPED ROOF, 30 PV MODULES f!J tO (34°) (SILVER FRAME),172°AZIMUTH 0 L u > M LEI O H 11 t 0 CD 1 SITE PLAN AERIAL VIE PV-2 SCALE: 1' = 20' SITE PLAN DOC ID: 98269-123488-1 DATE: 9/25118 CREATOR: S.S. REVIEWER: REVISIONS PV-2 GENERAL NOTES EQUIPMENT LIKELY TO BE WORKED UPON WHILE 1 ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 1101fi. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL 3 EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. WHERE DC PV SOURCE OR DC PV OUTPUT CIRCUITS ARE RUN INSIDE THE BUILDING, THEY SHALL BE 4 CONTAINED IN METAL RACEWAYS, TYPE MC CLAD CABLE, OR METAL ENCLOSURES FROM THE POINT OF PENETRATION INTO THE BUILDING TO THE FIRST READILY ACCESSIBLE MEANS, PER NEC 690.31(Gj. 5 ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE A RAINTIGHT FIT, PER NEC 358.42. PV MODULE — 1 I MODULES OPTIMQER REF. pTY. MAKE AND MODEL pdfAX PTC ISO IMP VOC VMP TEMP.COEFF.OFNOC FUSE RATING i PM130 30 JINKO JI0.1285M80 295W 271W 9bIA 9.10.A 39.7V 32AV 41.f 15V1'C I-0D°U•C) USA t PM130 INVERTERS I ( 295W 1Q Q2 EF. tt MPl(E M'D MODEL ACVOLTAGE GROUND MAXWPORATING RATED POWER MAX OUTLt CURRENT MAX INPUT CURRENT MAX WPM VOLTAGE CEC WEIGHTED EFFICIENCY ISW { "IN 11 I SOLAR EDGE SE7600H-US 24�V UNGROUNDED 40A I.BIKI 32.OA 20AA 480V 99.0% IETRWG �BTPING QQ I 1 POWER OPTIMIZERS I ! REF. OTY. MODEL RATED INPUTPOWER MAC OUTPUT CURRENT MPX INPUT ISO MAXOC VOLTAGE WEIGHTED EFFICIENCY ( PO1.30 30 SOLAREWE MO ]20W IY Ii.OA 4AV 98S% I' t 1 - DISCONNECTS OCPDS Rff. Ctt. MAKEANDMWEL RATED CURRFN7 MAX MTED VOLTAGE REF. Ctt. RAIEDCURRENT MA%VOLTAGE SW1 1 FATOY W222NPB OR ECUIV. EDA 240VAC Ft-2 2 40A 240VAC 1 SYSTEM SUMMARY NOTES JUNCTION BO% STRWGI STRWG2 ©OPTOTQERS PROVIDE PAPIDENUf00WNNNCPONAIIiY REWIRED BYNEC690.t2 PIIAIfZERS MAI(CIIIP/T CURRENT IM 15p JBT PTIN IN SERIES 15 15 THE SPEGFIEDOPTOAl2ER CAN BE SUBSTITUTED PATH A PQ(). P405, MO. OR F505. THESE OPPMZERS HAVE AN INPUT VOLTAGE WINDOW ME ENOUGH TO IONWALSTRWGVOLTAGE dODJ dOpV � 2 ACCOMMODATETHEOUTPUTVWTAGERMIGEOFIEIEMODULEATTFIEDESIGNTELIPERATURES.HAVEAL%XWFWCURRENTRATWGTHAT6ABOVETHEN OUTPUT YOPEPATINO WRRf:NT 11.tA 11.tA CURRENT OF THE MODUIE,ANDA MAXPOYIER INPUT THAT IS ABCVE7HE RATED POWER OMPUTOF THE MODULE INVERTER YSTC POWER BMW -- YPTCPOWER 8.142W ® UNGROUNDED SYSTEM W CONDUCTORS SHALL BE CDUORLWED AS FDLLOWS DC PDSMVESHALL BE RED (OR MARKED RED) ANDDC NEGATIVE SHALL BE BULK(OR II TAM IAC CURRENT 32A MARKED BUCK) ACPOWER 7.MVI — — i QN ERATED(CEC) AC POWER TAM A, MAX DC VOLTAGE OF ARRAY FIXED BY THE INVERTER AT 400V REGARDLESS OF TEMPERATURE. THE MAX DC VOLTAGE OF THE MODULE AT O-C IS EXPECTED TO BE 42.6V (O'C-2a C)X-0.11 SVIC-39.N=42.6V). INVERTER IS NON -ISOLATED. NO DC GEC IS REOUIREO. POINT-0FL NNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT. W COMPLIANCE WITH NEC 705.12(A). rvd lSwl 60A i _1_ 4 AC GEC SERVICE DISCONNECT AND MAIN DIST. PANEL (200A MSP W12DOA MBR) KNJHR UTILITY METER 240/120V 1¢, 3W CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS CUPREMCARSIIN TEMP. CORR CONOUITFILL CONT. MAX.CURRENT BABE CERAM TERM, AMP.®TERM . VOLTAGE TYPICAL CONOUCIOR CONOUR GLONDUCTORSW CONOUR OCPD EGC FACTOR FACTOR CURRENT (125%) AMP, pMp, TEMP. RATNG TEMP. RATWG LENGTH DROP 1 2 IOACOPPER FREE AW N)A WA 6 COPPER WG BARE 0.76(SS'C) 1.0 1S4 1Bi5A SSl 41.BA TS'C SOP SOFT 0.91% 2 1 10ACOPPER 0fATYIGTH�90 4 WA 10AAPPE 0.76(SS'C) OS 15A f675A 404 243M 60'C 30A SOFT O.47% 3 1 BA COPPER 2, 0EMT 2 WA 6ACO ER 0MEVC) 1.0 37A dOA SS4 52E4 fi0'G 40A 10FT 011% 4 1 BAYK3 N 2. &FDIA 2 40AX2 IDAWGTHW 2, Om (33'C) 1.0 32A 40A 55A U-M 75-C SOA 1OFT 031% COPPER EMT COPPER GENERAL ELECTRICAL NOTES UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL 1 PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 IMODULES CONFORM TO AND ARE LISTED UNDER UL 1703. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS 3 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.8 (D). CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE 4 SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). GROUNDING NOTES ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE 1 REQUIREMENTS OF NEC ARTICLES 250 & 690 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY -IN LUGS. INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 3 "GROUNDING AND BONDING' WHEN USED WITH PROPOSED PV MODULE. ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED 4 FOR THEIR PURPOSE IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A 5 VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) 6 SHALL BEA MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF 7 #IOAWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE GROUNDING AND BONDING CONDUCTORS, IF INSULATED, 8 SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER m 7 cU F-- U �Lu m O O C/) :if d � uj U O cYLu u5 U) I— LLJ Lu O M � U ckf CFI SINGLE -LINE I DIAGRAM DATE: 09/25/18 CREATED BY: S.S. CHECKED BY: REVISIONS SINGLE -LINE DIAGRAM PV-3 SCALE: NTS _ D�/� THO WON/EO FLYS SEEN tlEATED FOR MEIDPOS PE a DESCR6W­ON ON OF A PROPOSED FN0T0lMTAC POM14PSYSTEN M EN—H—TO DENONST—Ml�Y.V31511HA APftG9LE O(MSANO REGIMTTO£ THE OOLIrvFNT SHODUx 9E NE11LD UPON AS A v.IeSTN1E FOR r J HlLLOAWG MANDFALNRFA WSIAWNON NNIWti N9TK1EPSHNLW6igLLALLEWiFUEM W ACCOXM SE151M NAM1LFACRIRER WSTP11AlIDN W+MLLLS. NOTIIIHG W 1NL5OSIIUFNTSHOND BE WIENPIQ:TED W AwAY Du}OVERRYIES MEIxSDNGTI0N5M WJNFACIUf�R PiSFAOATON NANWLS. DC RACEWAYS O JB1 -TRANSITION BOX MODEL NOT SPECIFIED O O 11 -INVERTER SOLAR EDGE SE7600H-US O O O SW1 - DISCONNECT EATON DG222NR8 O O O O UTILITY METER O 0 SEE NOTE NO.4 (DC RACEWAYS) NEC 690.31(G)(3) AND IFC 605.11.1 OOC DISCONNECT (11) NEC 690.53 OANY AC ELECTRICAL PANEL THAT IS FED BY 7 BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (SW1, UTILITY METER) NEC 705.12(D)(3) 2 EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (JBI,11) e'ELECTR(v`�Skt()CKHAZARfl flON07TQUCH " �'CERMIIVN.S` TERMINALS ON BOTH L1NEAj}(1 � LOAD SIDES MAYBE.ENERGIZEOlN T}iDPEN PO$1i10�1, �s z-u NEC 690.17(E) PH0T0VOL_TA(C`SYSTEM EIZILOpED WITH. RAPID SHUTDOWN° OAC SOLAR DISCONNECT (SW1) OEACH DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE (JB1 11) ` ELECTRIC SHOCK HA7.AVR0 THEDG 7{.`,ONRUCTOR3fl�TNIS PNOTOVOLTLdG.�YSTEM ` ARE UNGROUNDED ¢NDMAY BE ENERGIZED NEC 690.35(F) OAC DISCONNECT(SW1) NEC 690.54 LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. LABELS, WARNINGS) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD 2 HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50%TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(8). A PERMANENT PLAQUE OR DIRECTORY SHALL BE 3 INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). LABEL(S) WITH MARKING, 'WARNING PHOTOVOLTAIC POWER SOURCE; SHALL BE LOCATED AT EVERY 10 FEET OF EACH DC RACEWAY AND WITHIN ONE FOOT OF 4 EVERY TURN OR BEND AND WITHIN ONE FOOT ABOVE AND BELOW ALL PENETRATIONS OF ROOFICEIUNG ASSEMBLIES, WALLS AND BARRIERS. THE LABEL SHALL HAVE 318° TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND LABEL(S) WITH MARKING, "PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN; SHALL BE LOCATED 5 AT POINT -OF -INTERCONNECTION OR AT MAIN SERVICE DISCONNECT THE LABEL SHALL HAVE 318- TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A REDBACKGROUND Lu ~ } W CV Lo m af W U c Fn J LL a_ 0' Z 0 QLu U J J 0 Y ui Lu " co cl LLIO M U a_ ctf SAFETY LABELS PV-4 P-98269 f� W �-{ Cn U W LN[� U rn !` � Z W U ch W 0 OW Z y W Q � U r' i a W U J Y W H (n W pp O M U 1 ATTACHMENT PLAN OBLIQUE PROJECTION I PV-5 SCALE: 1' = 20' f� ATTACHMENT PLAN DOC ID: 98269-123488-1 DATE: 9/25/18 CREATOR: S.S. REVIEWER: REVISIONS PV-5 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 8/12(33.7°) MEAN ROOF HEIGHT 38.8FT DECK SHEATHING 7116° OR THICKER OSB OR PLYWOOD CONSTRUCTION TRUSSES (2X4TQP-CHORD), 241N OC MODULE MECHANICAL PROPERTIES MODEL JINKOJKM295M-60 DIMENSIONS (AREA) 65.OIN X 39.11N X 1.61N (17.6 SO FT) WEIGHT 41.9L6 MOUNTING SYSTEM PROPERTIES 112.BIN (ZONE 1) MAX. ALLOW. RAIL SPAN 104.41N (ZONE 2) 87.61N (ZONE 3) NOTES RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED'MAX. MOUNT SPACING" I' Ai`:, RACKING ELEVATION RANSVERSE VIEW) `•,PV-6 ` SCALE: NTS i 'AN -� Ie RACKING ELEVATION (LONGITUDINAL VIEW) '111V- j•' SCALE: NTS - - - IRONRIDGE PV MODULES XR10 RAIL QUICKMOUNTQMLM l" j �•- COMP. SHINGLE - - ROOFING MATERIAL W le"... jY-.---(- FLASHING INSTALLED U j W04 BETWEEN UPPER AND >- U) Lo U m LOWER COURSE OF z C) M SHINGLES W 0 O FASTENER EMBEDDED i�:O W Z LL- INTO ROOF FRAMING d Q [if W U J — C ``, ATTACHMENT DETAILS (TRANSVERSE VIEW) --� YLLJ SCALE: NTS Wco(/) i MOUNTING NOTES p O M W FLASHING SHALL BE APPLIED IN ACCORDANCE WITH Lu U MANUFACTURERS'PRINTEDINSTRUCTIONS. F— IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED Q 2 HERE AND INSTRUCTIONS PROVIDED BY THE MANUFACTURER MANUFACTURERS' INSTRUCTIONS SHALL SUPERCEDE. PV MODULE r ' IRONRIDGE XR100 RAIL -- QUICKMOUNT 101 QMLM i ATTACHMENT COMP. SHINGLE DETAILS ROOFING MATERIAL DOC ID: 98269-123488-1 i DATE: 9/25118 CREATOR: S.S. - FASTENER EMBEDDED ~ REVIEWER: --- ' INTO ROOF FRAMING REVISIONS o` \ ATTACHMENT DETAIL (LONGITUDINAL VIEW) J\PV-6� F:� SCALE: NTS PV-6 l FIRE SAFETY PLAN PV-7 SCALE: 1 ° = 20' FIRE SAFETY REQUIREMENTS EXTERIOR -MOUNTED DC CONDUITS, WIRING SYSTEMS, AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, 1 HIP, OR VALLEY, AND FROM THE HIP OR VALLEY AS DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES (NFPA 1 11.12.2.2A.1) ROOFACCESS POINTS SHALL BE DEFINED AS AREAS WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED 2 OVER OPENINGS S INDOWS OR DOORS), ARE LOCATED AT STRONG POIN OF BUILDING CONSTRUCTION, AND ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS (TREE LIMBS, WIRES, OR SIGNS). (NFPA 111.12.2.2.1.3) PHOTOVOLTAIC MODULES SHALL BE LOCATED IN A MANNER THAT PROVIDES A3 FT WIDE CLEAR ACCESS PATHWAY FROM THE EAVE TO THE RIDGE OF EACH 3 ROOF SLOPE WHERE THE PHOTOVOLTAIC MODULES ARE LOCATED. THE ACCESS PATHWAY SHALL BE LOCATED AT A STRUCTURALLY STRONG LOCATION OF THE BUILDING, SUCH AS A BEARING WALL, EXCEPT WHERE ADJOINING ROOF PLANES PROVIDE A 3 FT WIDE CLEARACCESS PATHWAY. (NFPA 111.10.2.2.2.1.1) 4 PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS THAN 3 FT BELOW THE RIDGE. (NFPA 111.10.2.2.2.2) FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 O3.0 11.10.2.2.2.1.1 02 ROOF ACCESS POINT, PER NFPA 111.12.2.2.1.3 O3 0 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11.102.2.2.1.1 04 ROOF ACCESS POINT, PER NFPA 111.12.2.2.1.3 5 CABLES, WHEN RUN BETWEEN ARRAYS, SHALL BE ENCLOSED IN CONDUIT. Ll! H C/J CV o-, w U co Lli 0 J LL 0 Z ILLI LJJ U Of L1J C) J Y cl) c J 0 W OD C/) O M H U O a FIRE SAFETY PV-7 4 flusbar Solar Cell: l busbcr solar cell edcots Raw technology to improve the efficiency of :r!oa,ies . olfers ci butler aasinelic apperm rice, rnokir:g it perfect for rooftop in:tallalion. High Efficiency: Higher module conveaian efric-iency(up to 18.33%) benefit from PasstvateJ Emmiter Rear Contact(PERC) fachnclogy. PID RESISTANT: Lim'tec power degradation of Ecgle module ccused Dy PID affect is gL•arantrtF;d tlndP.r St(ICt tP.St!!lg COnditlan (65C/85`RRH.Y6noars)ror moss proJuc!ioe QLow -light Performance: Ad•Janced gloss and color call surface toxtunng allow for o-oilent performance in low-tgh' environmerns. tY1 Severe Weather Resilience: Certified to withstand: •.rind Toad (2410-3 Pascal) end snow loco (5400 Pascal). Durability against extreme environmental conditions: High sari mist and ammonia resiiancc certilied by TUV NORD. LINEAR PERFORMANCE WARRANTY 10 Year Product Warranty • 25 Year Uaear Power Wamanty .5 www.3ikoso41r.coln ' r. PV CYCLE CC ENC E `& COUNCfL "- PC6RIVEQU,ll.!Ty" P?EYecA -----_+^^^-'+•^.a.}.�W 6nearpetformancawarranty �x 9>R AdOtAanory Ua L__+r Stanticrtl Pertortnance wortanry 9sA a/ � rn'neo vw y 5 for's lb or h'orronh, m zx MEMMESSEMEM C,trme!•YCT:Dg a Po,•m V_n' TemPcrayry Depertlmx Curv-mom tdru_ya•,N( ,a'..-.7......__...._ _- ! i rs .._........ -7 x :C � 1 , :.-.w• ' 12 _ 1 1 I K Cell Type Mpno::ys10!lin:!PF.RC 156�156mm{6 inchl i j"rof ..L-_»,..... :..€. �Za.....•a �tGst ii._: ;,.P,s. Dimznsiors �165C.R02,:4Un:m(65.00<39.05.e157 indi,' 137nG4441Ys) root Gl3s H' I T 2 l ss an Lnt I r T mF 3c G 1 ;Dn<tion 0cx IP67 Resod Module Type JKl.W0M-i3U .11(1,1296M-e Jh?J OOhYuO JKM295M4,0 J10,13701.1.0 6TC 5}C AISCT SiC. YJC ilE NLCiy SC' E7{YT �j A It P 1 80YD 0 'p 2850ip 21 "9 hp 21' D 2Vip 220NF 30owl, 22,Wp ax Va ileum Poxe: Cumtnt V:rP) 6.61A 7.01A 9.90A 7.12A 9.02A 7.15A 9.10A 7.24A 9.21A 7.32A short-circuit Curt (Isc) P.49A 7.62r. 9.51A 7.72n 9,55A 7.61A 9.61A 7.ts9A 912A 6.01A ucle r�l cy,3 z' z 1tsa'3, X Ooeraina Temper wWVC) A9¢ u. 3�r Suet.!:...,..,,..... _3 _., ..:- ,... _..-... �, ,, ..,.,..e n........... ...1J0 0 IIEC)...�..-. __._._... .. .....c.,•.. _. ..v ..._.........., Mn?imam:;+rie5 f—'etin(i 15A Tamperlture coefficients of Pmm! a1.39',6r t Tenac 7tt-t`a off tens aE.c .._.........._....�..,,. �..a.._ .,..b,..._......, _. �a..,_W..a._..._..F._.,......,.�.,.,..r .............._..._ _... Tempe: Dture c:oeffi<ir nts ul ixc v...+ WC. $TC: ik zl(radiance 1000L`!/m' Cell Temperature 25`C AN1=1.5 NOCT: •:Irradiance 8004Y!m iAmbent Temperatwe 2LT°C AM-1.5 Wind Speed ln1/s - —Power m-`sspr--t tolerantc.•. 3K -- - --- - - - 'rh.� co.-mv-v ft.: riont k[ ec^Is'neG,!...., any of file M.- r.3non pr.=,en.a„ nemb.. Et-. ;Kh4 JJ%?.° .0.PER::_ re•201. solar.®® SolarEdge Power Optimizer Module Add -On For North America P320 / P370 / P400 / P405 / P505 U:;A.:.iM:JAG[:'.ht.tNriUK�iTA;^':iE4r:nt.f:`:aNv:�!J•.?Ah-^,.t:Nr.......'kSJ.in>tini.l�5{I.Y.Ci�:'6o:,.GiUM�l;r:k;:b:..;!z�3UiCi?.n... ry;+ir!gN4ViiiGi:,r .s ,,..>n <i1'e IWF. DD,`S0 . • At: iCA PO: 4 :: :511t Solar=@9 SolarEdge Power Optimizer Module Add -On for North America P320 / P370 / P400 / P405 / P505 — — P3T0 - ` OPTIMIZER MODE! P320 ( high-powe (for higher-powe C P400 P405 (pr 928,16-ce0 (fo !n fitm -P505 (f higher (typical mod Iec npadbllhy) (f !I bCmnd tf f. 6C ellm d le ). IZs modtJ s) odulcs} currentm doles) Pa d I Cut DC Pc er ......... 320 37G T" ........ ......................... 0 i IC5 .... ......... OS ......... .... VJ ..;. ...... Absolute Maximum Input Vaittge 96 1 60 36 125 i............ 83 Vdc ("vec at lowast temperaturel:............ ...................;....................! ! ....................:............. .. MPPT Cprradr., Ranpe .....,............. 1 848 E-60 �,............,.... 880 326-Su6 12593 Vdc MUximum Shc[Ci ............................... ..........._.................:............... ,.. a�,1................. ......... Maximum DC lnpu[Current i... �.... `................. 12 63_ .................. _.. .......17;'...... ...... .Adc ... .............................:................... MaximumLtfic enc'i ...................................................... i...................................... 99:5. ...................... .....,...... .... ... .....'...... . ..! WeighedEil'c enc........... ....... I..:......... ......... 99.9 .... I ........................ ......... ...... ............... .....!....... 08.6 . I....... .... �.... .. ..'�...... Maximum Output Current. ........ ... ... y... Adc ... ... ........... i.......... ............................... ..................... .:.... .............. .. Maximum Output Vc ta8e 60 85 Vdc �OU(PUT DURING SMNDRY:(POVJEROPTIMIZER DISCONNECTED FROM SOLAREDGE1NVfRTER,OR:SOLAREDGE IN rER1'ER OFFI. ..._:.._._..._..._._...._....._._.._._...._...._..._........_...;......__.___......._..,......_......_..__....._........_.._..._..._.._.._....____........_._..._...._.m..._......_._......_.__......_ ....... SafM.y Output Vcl:age per Power Gacmixer 110.1 Vdc STANDARD COMPLIANCE .:._.. .__._._.. ._..__._ .......... ............ .. _.._.:.. ... _.......... .......a. .... ,........ m. __._�_, _....0 EMt. FCC PartlS Class B, IEC61000.6-2, IECG100C- -3 r ..............._......_............. ......, ..................... _.._..._.q ...`..9........� ........................._ .......... Sat?ty ... �, IfC6210_-Klass 11 sa4ety). Uii79i, ,..... blaxin .um Allowed System Voltage lnfn� i Vdc i Ccntpatihlr. inverters All Sn'arEd1p51 r,R.I.d Thre Phase ierte' 1 ......`. ..... ..... ......... ...... Di-;=nsiors;VJx LxYI 128x 152x 23/Sxo.9?xl.l .le..h. .. 123x152x36/ 18x1S2x50/ : .... ...... ........ .. 128x152x59/ •nir/n i Sx 5.97x.... cx5.97 x1.95 5x5.97x 2.:i2 Wai�ht yindudine cablas;_ `30/34........ 7501t.7.....:,.... 3a5f ]r9...... ....1061?23... ...Ib,_„ Input Ccnneanr ........................................... i.. ..................................................,....................................,............ r........,.... Output V{Irft Type / Conneccnr { Dcuh'e Insulated: MC" Cu ,nut Wire Length R55 / 3:0....,..................................... �: '!.�''.�.`� ' m / �.... ........................... O_,rating,e:nFcraureRanaS........i.............. ,,,,.-40-+85i-•]0-+135 .................... ............................................... .. •.,-I-C/'F..,. Protection Radn&......... ...................... .............. IP6g y NEFAA6P .,.......................................... i......' . ;....... ...... ............................ ............ 1...................................................'............,.......................................:...,......... ;, "':L-:etl Stt poworer the maaute.:iiVu:a: of •�a Ic+SR; Vasuc: MNran<r a!'ewrd 'S Far a+ter ceanMer ;pei ataase cttract Sala�aee Minimum String Length z .. :........... ................ .................. ;cower Optimirersi P4L'S /PSOS........i....... ................ �.......... g........... i.......... i-....... . I.......... ........... Maximum Stnng Lengdt 25 25 su. (r'ower.,ptrmizersi .. ............ � ........ i ........... ......... .......... ........... ................. ............... ,...................... ' ..... . .... Maximom Pa er per String SEY600H-U5, 5250 6000 12750 W .............................:........... ..............:............ ............:....... ........ ......... i............. Paral!al Strings of DiHzrent Lengths ravel......sofD er Crrntations yes ...............................................J........,................,.......................... ,...... .............. ........ ................ ............ zed:; m¢.matlms,.m r.,F::;.: nma�dw redsa:a:lsi�x!der_aeiriv4m::,g_::ere.aa.;yr. at al:w.ed to mix=c!KjYSU'vov i:h Y3lJIYa)O/YxUU(YG4•wYYa�/YtlW In one srr:-tl. T st:lar, u:th morn na�+. SCaCbm'Isnduz oat mun NEC rani! sbuL'axm:ea�ia_��as; safety vatase x+li a abwethe 1e's'rmu.emert Single Phase Inverters for North America SE300OH-US i SE380OH-US 1 SE500OH-US 1 SE6000H-US; SE7600H-US/SE1000OH-US C �:�> fqk.! L:'. ra ,..YY..>.. :i t3... iRG:itiS i;,'aria✓•lhs.:..iSIR;(.kr>.R:,,:i. f. +i£ N,...0 i ."f _.;f .ia 3t _..X n. k0+!rk F :iit. nrC'! i'xi•{N':k Y.'itiV.'.$� 13iC(igC.li.', solar =11 Single Phase Inverters for North America SE3000H-USISE3909H-US!SE5090H-US! SE6000H-US1SE7n09H-US!SE1030OH-US SE3..... US SEs6tICH US .€ SESWI}ti US,. _ SE6tiWH t!S - 5E760gH US - :563flDtiCH U5 __ . _,.._ SAC Pn E CY tp K, 3CL'u 3SrA t.., €.JC GGCl7. 71)(1 ?AQ'Rl id •R_N .... ., Mnz A pnr(C'i1 t ..., ,.. 33(:L'Yn ., :... .. AC Ca•Pt VAug*e M!;..Nom: ...... .... , .,. .. ........ .. ..... �. �., �. .. ... .. .. ... ,.tac... M1!3z x t x4o x�a3 ..,.• .. ..... AC Fre�uC.L _Ncm al) ............. ......... ........12.5 .... .. 59a EG cG.S'" .., ... E....i+z , .. tfsx;mu^t C+rainuoiu Ci!tpai , •� 23 25 32 .. 42 A 251�tc.,.,.._...............:.. ........ ........_,......,.... ................ E ..... ...... ... ........._.^......,,..,...,..,..., .. ,.. ... - G� i hri:5ho13 AMh2*Rl ip...................s..............:...... ..................... .... ...... ...=:.............:...: ,. .................... I , . . Proteaiait Cooney Ca:fig::tpire. ve; E ............ :.......:...,....,............ 1 mnSfnmtPr•iP.55, '.?nt;ro:;nded :.::.......:........:......._.:,..,.,,::.::..............,:::.:...... ...... ....,... . ............. ... ...... ........... .................... Na na •'?C 1. 4oEWi.S... r. :. .... .. _.-.. .. 3kiC... .......... .. .. .................... i...4x .> tzta<m! nvutC T� t y 4Gb. ..� .....,.•. C'?... :.. `'........; iE�.S '.........�G 2 t A� ... D.A -nii thu F. Ctr t. !......... ............. ..•................ . ..Is .... - 45 - ..... ........... .. .....•..,.. ., ., •: x. RP 2^$P Ya)dfPy P PfttOn ..... ............................... C3. .. ......... ... .................... t.. .._ Cv;:nd•We!Y:sa?sea't Oeteutinn ,,. 6ElG"wt SemtSsrt ...,. ... ....................,..., . M man. nee to N a x ............ 99. ........................ 9<J .. ........, 4 x, _ C:CWf gh ed tf.cet .. ....... ... ................,... .. .. ... .. .. .... ..... ..... .,. ......: .... ..J.... Wihtttt aW'>r Ca .w. P' n. <. ZS a.Ihn pf !SilparedCam int . R54+ c he" Pe lnptia Ce uls apta 1 P a) i ftevarue G^ade Ua'a ANSC12.20 fiptivnaE BeP�J s*<.tenwn NEC Ct4 0. d .... 11 Automatic Rap d Sfi.tdo sip.s, AC Grid L{xpnnecf ........... (.......... , 5TAtdDARD_____CQMPUANCE' ._..__.._ , .,+„ U 47 UL27 41 SA. ULi C'i3R CS!1 Cxx.7 Ctmd a F E aC' cr'1 ..... y, W TI t F4 G7 C.,Ccrnemvc5ta darts ........ tEEE Si7, F`uEe 21 Pile IkU , .......... ........;.. ... . En ssioiti FCC Par• 15''It :; ti _ ;th}STAI;tAT8pA1 SPEGi:•tC,ATiCNS AC Gutp;.t Cvrd.it Si.a; Ai'JG 3j4 nim'm 2C4At YG . ..> ............................,...... ! ............... ........ OC bmu•, Camiait Si:r. (ri of Str;nRc 'Jd" r,Onmmn! j 1.2 uryss j to b AYJG i /1.3 ,trines £ l Range i t4-6:14V(i MmP :si,mt with 5 cty5 :i<fl 77z G8 45Cx3.Gx'7•' t�..',: 11.3 146x 73 iCx37G E: i'rm i EHxYraUj %iRS 1 .... .' ....._ ....... ..... .22!1G .. ..,.. ....._ .....,.... t x51 li.:,...<- 2fiZr319....... .... ... .... .. ,. ,. ... .... , ...... (....j,9,.8,t2 5„•. i.. bl kg,,, riaae f.. <x <a faa ... .......................... Cp_:auog Temaeratu eRanpe � .......:.... Na•urair'an•=^�n i ,.............................. ... ..... 131o+>1Gi-7S to •G(X"�4C'G J.:tQ'C egtian}u ................... Ha•.urai rvM:echod ... F... ...... .. ,'F(,C•„ Protectlnn !iating .....,.. ........... .... REt to 3R jinvzffer v;iFh Sall t, Saitdl) ............... ..................- ....................... . ..... o!Merepm.^.i sr:�ecji [;iemerar!:xF£ri: xtyz k:avn; �dc 7'd �e N' ELSd. fl `�.r�6da¢ tlC ::tt:�i�t.r:*:nie R ro nh .;.taw tea!xAR"d,t;•ii+tt;t^.R •' -W y.Rien P^L :UaN%:.'lr.+tl)iHJa Y:N It s�e-+pear,!a Ge'aG C.::.?e.•yCC: IRONRIDGE Built for .solar's toughest roofs. Flush Mount System IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 20-year warranty. Strength Tested PE Certified All components evaluated for superior Pre -stamped engineering letters structural performance. available in most states. -- X R Ralfs <3 XR10 Rail XR100 Rail XR1000 Rail Bonded Splices A low -profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. 6'spanning capability 8'spanning capability 12'spanning capability Self -drilling screws Moderate load capability Heavy load capability Extreme load capability Varying versions for rails Clear & black anod. finish Clear & black anod. finish Clear anodized finish Forms secure bonding --- Clamps & Grounding r, UFOs Stopper Sleeves Grounding Lugs Microinverter Kits Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount Mls or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. Fully assembled & lubed Bonds modules to rails Low profile Bonds devices to rails Single, universal size 6 different sizes Single tool installation Kit comes assembled Clear & black finish Clear & black anod. finish Mounts in any direction Listed to UL 2703 FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs , i tf: , , " - Wi, Flash and mount XR Rails Drop -in design for rapid rail Bond and attach XR Rails Raise Flush Mount System with superior waterproofing. attachment. to certified attachments. to various heights. Twist -on Cap eases install Secure rail connections T & Square Bolt options Works with vent flashing Wind -driven rain tested Slot for vertical adjusting Nut uses 7/16" socket 4" and 7" lengths Class A Fire Rating Design Assistant Mill &black finish Clear & black anod. finish Assembled & lubricated Ships assembled Certified to maintain the fire resistance r Online software makes it simple to rating of the existing roof. 7create, share, and price projects. Resources Design Assistant NABCEP Certified Training LIL 2703 Listed System 20-Year Warranty Go from rough layout to fully �' —,' Earn free continuing education credits, W—competitors.— engineered sys tem. For free. �" i� while learning more about our systems. Entire system and components meet Twice the protection offered byCsc to Ora€iRicirfe.com,'design izS 4v ironRiciye,Dornt_newest_effective_UL2703_standard. __ IRONRIDGE 11495Zephyr ,CA9Avenue 544 Hayward, - 94544 ?1-800-2279523 I IronRidge.com Attn: Corey Geiger, VP New Markets, IronRidge Inc. Date: December 2011, 2017 Re: Structural Certification and Span Tables for IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3l8" stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion at is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core ,mponents are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the following reference standards for the load conditions and configurations tabulated in the attached span tables: ASCE/SEI 7-10 Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) 2015 International Building Code (IBC-2015) Florida Building Code 61" Edition (2017) Building 2015 Aluminum Design Manual (ADM-2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones 1, 2 & 3, and roof slopes from 0° to 45°. The span tables are applicable provided that the following conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener) 2. The underlying roof pitch, measured between roof surface and horizontal plane, is 450 or less. 3. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module width shall not exceed 40". 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount installation manual and other applicable standards for general roof construction practice. 1495 Zephyr Avenue I layward, CA 94544 1-800-227-9523 IronRidge.com The span tables provided in this: letter are certified based on the structural performance of IronRidge XR ,Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. j* 7ara}u¢aatae Sincerely, �'°0w6 xvq"f�.y� _ �•t'L•�Oh.F' C�;(/kr '41 Gang Xuan, PE, LEED AP ��r aNt sacra Senior Structural Engineer 0 2017 IronRidge, Inc. FL Flush Mount System Certification Letter- 1 U 2017 IronRidge, Inc. FL Flush Mount System Certification Letter- 3 The Flush Mount System may be used to ground and/or mount a PV module complying with UL 1703 only when the specific module has been evaluated for grounding and/or mounting in compliance with the included instructions. Unless otherwise noted, "tax" refers to the module power rating and both black and silver frames are included in the certification. Modules with 35, 40, or 45mm frames and model identifier aaSM66yyPzz-xxx; where "aa" is CH Astronergy Solar j or A; "yy" is either 10 or 12; and "zz" is blank or (BL). Frameless modules with model identifier CHSM6610P(DG)-xxx. Axitec Modules with 35 or 40mm frames and model identifier AC-xxxY/aa-ZZ; where "Y" is M or P; "aa" is 125 or156; and "ZZ" is 54S 60S or 72S. Modules with 35 and 40mm frames and model identifier CSbY-xxxZ; where "b" can be 1, 3 or 6; "Y" can Canadian Solar be K, P, U, V, or X; and "Z" can be M, P, AG, MS, PX , M-SD, P-AG, P-FG or P-SD, MS -AG, MS-FG, or MS -SD. Frameless modules with model identifier CSbY-xxx-FG; where V' can be 3 or 6; "Y" is K, X, or P; and Z' can be M-FG or P=FG. i Modules with 35, 40, or 50mm frames and model identifier ET-Y6ZZxxxAA; where "Y" is P, L, or M; "ZZ" IET Solar _ is 60 or 72; and "AA" is WB, WW, BB, WBG, WWG, WBAC, WBCO, WWCO, WWBCO or BBAC. Modules with 35, 40, or 50mm frames and model identifier FXS-xxxYY-ZZ; where "xxx" is the module Flex power ratin • "YY" is BB or BC; and "ZZ" is MAA 1 B MAA1W MA81W SAA1B SAA1W SAC1B '.SAC1W SAD1W SBA1B SBA1W SBC1B orSBC1W. GCL Modules with 35 and 40mm frames and and model identifier GCL-a6/YY xxx; where' a" can be M or P; and YY" can be 60, 72, or 72H. GigaWatt Solar Modules with 40mm frames and model identifier GWxxxYY; where "YY" is either PB or MB. Hanwha Solar i Modules with 40, 45, or 50mm frames and model identifier HSLaaP6-YY-1-xxxZ; where "aa" is either 60 or 72; "YY" is PA or PB; and "Z" is blank or B. I Modules with 32, 35, 40, and 42mm frames and model identifier aaYY-ZZ-xxx; where "aa" can be Q. or E B.; "YY" can be PLUS, PRO, PEAK, LINE PRO, LINE PLUS, or PEAK DUO; and "ZZ" can be G3, G3.1, Hanwha Q CELLS ' G4 G4.1, L-G2, L-G2.3, L-G3, L-G3.1, L-G3y, L-G4, L-G4.2, L-G4y, LG4.2/TAA, BFR-03, BLK-G3, BFR-G4, BFR-G4.1, BFR G4.3, BLK-G4.1, G4/SC, G4.1/SC, G4.1/TAA, G4.1/ BFR-G3.1, BLK•G3.11 MAX, BFR G4.1/TAA, BFR G4.1/MAX, BLK G4.1/TAA, BLK G4.1/SC, EC-G4.4, G5, BLK-G5, L-G5.2, or L-G5.2/H. Heliene Modules with 40mm frames and model identifier YYZZxxx; where "W" is 36, 60, 72, or 96; and "ZZ" is _..._........... ....... _....... M, P, or MBLK. g.........._-_-._..._.._.......... __._..__..._.._.._....... ... ............... _........................... ....._.........,._..__...__.._....... ._...___....__.___....__._... _ ........... _..____..._.... ......... Hyundai Modules with 35, 40 and 50mm frames and model identifier HiS-YxxxZZ; where Y' can be M or S; and "ZZ" can be MI, MF, MG, SG, RI, RG(BF), RG(BK), TI, or TG. Itek Modules with 40 or 50mm frames and model identifier IT-xxx-YY; where "YY" is blank, HE, or SE, or SE72. _ ! Modules with 35, 40 and 45mm frames and model identifier JAyyzz-bb-xxx/aa; where "yy" can be M, P, NIA Solar s M6 or P6; "zz" can be blank, (K), (L), (R), (V), (BK), (FA), (TG), (FA)(R), (L)(BK), (L)(TG), (R)(BK), (R) t, (TG), (V)(BK), (BK)(TG), or (L)(BK)(TG); "lob" can be 48, 60, 72, 60501 or 72501; and "aa" can be MP, ` __..............___._._......._...........,_..._....._._..... SI, SC, PR, RE, 3BB, 4BB, 4B6/RE, 5B8. _..__....... __........... _._..._................_...._.........._......_............................. _ _...._..... __.......................... _.._..:.......... _..... ...... Modules with 40mm frames and model identifier JKMYxxxZZ-aa; where "Y" is blank or S; "ZZ" is P, Jinko PP, M; and "aa" is 60. 60B, 60-J4, 606-J4, 60(Plus), 60-V, 72, or 724. Frameless modules with model identifier JKMxxxPP-DV. Modules with 46mm frames and model identifier KYxxxZZ-AA; where "Y" is D or U; "ZZ" is blank, GX, or Kyocera I SX; and "AA" is LPU, LFU, UPU, LPS, LPB, LFB, LFBS, LFB2, LPB2, 3AC, 3BC, 3FC, 4AC, 413C, 4FC, 4UC, 5AC, 5BC, 5FC, 5UC, BBC, 6FC, BBC, 6MCA, or 6MPA._...W..._._._._...._._....... ............. _......_.......... ....... _._. _ LG _._._....................._....._....._....... _.........._......_.................. ..... _._.----..__._.........._..............._..._._.......... _...... Modules with 35, 40, and 46mm frames and model identifier LGxxxYaZ-bb; where Y' is A, E, N, O, S; a is 1 or 2; "Z" is C, K, T, or W; and "bb" is A3, A5, 133, G3, 04, or K4. Longi I Modules with 40mm frames and model identifier LR6-YY-xxxM; where "W" can be 60, 72, or 72HV. Mission Solar 1 Modules with 40mm frames and model identifier MSExxxZZaa; where "ZZ' can be MM, SE, SO or SO; and "aa" can be 1 J, 4J, 4S, 5K, 5T, 6J, 6S, or 6W. I Modules with 46mm frames and model identifier PV-MYYxxxZZ; where "YY" is LE or JE; and "ZZ" MoteMitsubishi is either HD, HD2, or FB. ch IM and XS series modules with 40, 45, or 50mm frames. �Pan7a..nic r € Modules with 35mm frames and model identifier DBYxxxZZaa; where Y' can be M or P; "ZZ" can be B3A, B4A, E3A, E4A, H3A, H4A; and "aa" can be blank, (TF), ME or ME (TF). ..........__.... ______.____._.._____.�.._____ _._._---- _.____ W._.__.__._____.__._...._._.___._._._._ .._._____.._._.__....._..... Modules with 35 or 40mm frames and model identifier VBHNxxxYYzz; where "W" is SA or KA; and "zz" is 01, 02, 03, 04, 06, 06B, 11, 11 B, 15,1513, 16, 16B, 17, or 18. Phono Solar Modules with 35, 40, or 45mm frames and model identifier PSxxxY-ZZ/A; where "Y" is M or P; "ZZ" is 20 or 24; and "A" is F, T or U. Prism Solar Frameless modules with model identifier BiYY-xxxBSTC; where "YY" is 48 or 60. REC Solar Modules with 30, 38 and 45mm frames and model identifier RECxxxYYZZ; where "Y.Y" is M, PE, TP, or TP2S; and "ZZ" is blank, BLK, SLV, or 72. i Renesola Modules with 35, 40 or 50mm frames and model identifier JCxxxY-ZZ; where "Y" is F, M or S; and "ZZ" is Ab, Ab-b, Abh, Abh-b, Abv, Abv-b, Bb, Bb-b, Bbh, Bbh-b, Bbv, Bbv-b, Db, or Db-b. ( „ Renogy Modules with 40 or 50mm frames and model identifier RNG-xxxY. where Y is D or P. ' S-Energy Modules with 40mm frames and model identifier SNxxxY--ZZ; where "Y" is M or P; and "ZZ" is 10, or 15. Seraphim Energy Group Modules with 40mm frames and model identifier SEG-6YY xxxZZ; where W" can be MA, MB, PA, PB; and "ZZ" can be BB, WB, or WW. �� Modules with 40 and 50mm frames and model identifier SRP-xxx-6YY; where "YY" can be MA, MB, Seraphim USA A PB, QA-XX-XX, and QB-XX-XX. __...._.......... .... .. ........ .._._.._........................................................................_........_....._........_......_.........__._...._.._....._......._............__......._._................................._.._...................... Sharp Modules with 35 or 40mm frames and model identifier NUYYxxx; where "YY" is SA or SC. Silfab Modules with 38mm frames and model identifier SYY-Z-xxx; where "YY" is SA or LA; SG or LG; and IIII "Z" is M, P, or X. Solaria Modules with 40mm frames and model identifier PowerXT xxxY-ZZ; where Y' can be R or C; and "ZZ" is BX, BY, PX, PZ, WX or WZ. SolarTech Modules with 42mm frames and model identifier STU-xxxYY; where "W" can be PERC or HJT. SolarWorld Sunmodule Plus, Protect, XL, Bisun, Bisun XL, may be followed by mono, poly or duo and/or black or bk; modules with 31, 33 or 46mm frames and model identifier SW-xxx. Stion Thin film modules with 35mm frames and model identifier STO-xxx or STO-xxxA. Thin film frameless modules with model identifier STL-xxx or STL-xxxA. t___..._._. €_ I Modules with 35, 40, or 50mm frames and model identifier SE-YxxxZABCDE; where -Fs B, F, H, j SunEdison ( P, R, or Z; "Z" is 0 or 4; "A" is B, C, D, E, H, I, J, K, L, M, or N; "B" is B or W; "C" is A or C; "D" is 3, . 7, 8, or 9; and "E" is 0, 1 or 2. _ Modules with 35, 38, 40, 46, or 50mm frames and model identifiers OPTxxx-AA-B-YYY-Z Suniva or MVXxxx-AA-B-YYY-Z; where "AA" is either 60 or 72; "B" is either 4 or 5; "WY" is either 100,101,700,1 BO, or 1B1; and 'W is blank or B. Modules with model identifier Ab-xxx-YY and standard (G3) or InvisiMount (G5) 46mm frame; Sunpower where "A" is either E P or X• "b" can be 17 18 19 20 21 or 22• and "YY" can be blank NE BLK COM_C-AC D-AC BLK-C-AC, or BLK-D-AC. Sunpreme Frameless modules with model identifier GXB-xxxYY; where "W" is blank or SL. _ Suntech Vd, Vem, Wdb, Wde, and Wd series modules with 35, 40, or 50mm frames. .................. _._.......................... _......_............... ....... -........ _... _........... __..... ......... ..... --.........__..........................._.._..._..._......._..._....__._...._........_._.................__.._.....__....._.._._....__..__._........................._-- Modules with 35, 40 or 46mm frames and model identifier TSM-xxxYYZZ; where 'YY" is PA05, PC05, PD05, PA14, PC14, PD14, PE14, or DD05; and "ZZ" is blank, A, A.05, A.OB, A.10, A.18, .05, Trina .08, .10, .18, .08D, .18D, 0.82, A.082(11), .002, .00S, 055, OBS, A(II), A.08(11), A.05(11), A.10(11), or A.1Bill). Frameless modules with model identifier TSM-xxxYY; and "YY" is either PEGS, PEG5.07, PEG14, DEG5(II), DEG5.07(II), or DEG14(11). I Winaico Modules with 35 or 40mm frames and model identifier Wsy-xxxz6; where "y" is either P or T, and I 'z is either M or P. ,_Yingli Panda YGE and1GE-1Lseriesmodules with 35,40_oL50 mm_frame_ L-Mount I QMLM / QMLM2 Elevated Water SealTechnologyrlit EDGE TOWARDS ROOF RIDGE .................._._....__............._......_._ ITEM NO. . . . ._...._._.. ........._............................_._._...._......_.._.._......................_...., DESCRIPTION CITY. I 1 FLASHING, ROUNDED CORNERS, 9" X 12' X .040", 5052, MILL 1 2 L-FOOL TX 3.30" FOR .438" O.D. FASTENER, 6061-T6/6005A-T61, MILL I 3 WASHER. SEALING. 5/16" ID X 3/4" OD, EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD, 5116' x 4", 18-8 SS 1 L-FOOT 2'X3.30",2X.75"SLOT FOR.438"O.D. FASTENER, 6061- T6/6005A-T61 MILL I I iw— ................... _.. 47 ..._..._..._....._r ......; 2.1301 ... I i . t ...... ....... _.5.........1._. 75...: +...............�............._P.... QMLM2: 4 2 X .75 SLOT VERSION ' OPTIONAL 3 Il��f 0 n AVAILABLE IN MILL, AND BLACK FINISHES TITLE: ;, 4 2.50 QMLM2 QMLM: L-MOUNT, 5/16" LAG, 9" i................._............_p.... X 12" FLASHING QMLM uniles;omfxwucsven:i_n: ; SIZE DRAMJsf: RAD REV ......... .._..... ...... C O _ A A DATE 6/]2/101J 5 r mau.^ u•v*at oanw a raaum.oa v. wOraa,:.sneo CO GM01060N OVMrV r0&, r Da, SC IE WFIGM IOMJ 5f£tl Cfl / 5 4 3 2 1 L-Mount Installation Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with 7/32" bit, drill or impact gun with 1/2" socket. Locate, choose, and mark centers of rafters to be Carefully liftcomposition roofshingle with roofing Insert Flashing between 1st and 2nd course. Slide mounted. Select the courses of shingles where bar, just above placement of mount. Remove up so top edge of flashing is at least 3/4" higher mounts will be placed. nails as required and backfill holes with aproved than the butt -edge of the 3rd course and lower sealant. See "Proper Flashing Placement" on nerd flashing edge is above the butt -edge of Zst course. page. Mark center for drilling. Using drill with 7/32" bit, drill pilot hole into roof Clean off anysawdust, and fill hole with sealant Place L-foot onto elevated flute and rotate L-root to and rafter, taking care to drill square to the roof. compatible with roofing materials. desired orientation. Do not use mount as a drill guide. Drill a 2" deep hole into rafter. Prepare lag bolt with sealing washer. Using a 1/2 You are now ready for the rack of your choice. inch socket on an impact gun, drive prepared lag Follow all the directions of the rack manufacturer bolt through L-foct until L-foot can no longer easily as well as the module manufacturer. NOTE: Make BI 7.2.3-44 Jun-2017 Rev 2 BI 7.2.3-44 Jun-2017 Rev 2