HomeMy WebLinkAboutIRONRIDGE STRUCTURAL CONNECTIONS FOR PV MODULE ARRAY ON PITCHED ROOF�7 PHOTOVOLTAIC MODULE GENL cc L NOTES: 1. APPLICABLE CODE: 2017 FLORIDA BUILDING CODE 6th ED. & ASCE 7.10 MINIMUM DESIGN LOAI FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER_AND EMB.EDWENLLENG.THS-ARE-DESIGNED-PER-N DS(201.2)-REQUIREMENTS.-ALL CAPACITIES ARE BASED ON A SOUTHERN YELLOW PINE (SYP) WOOD ROOF TRUSS AS EMBEDMENT MATERIAL 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIENTIAL ROOFS, CONSIDERING FROM A 7" TO A MAXIMUM 27" (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOT EXCEED 30'-0" MEAN ROOF HEIGHT. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM, 6511. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. 7. LAG BOLTS SHALL BE ASTM, A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. B. ALL IRONRIDGE RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS_ 9.l CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH FBGBUILDING CHAPTER 16 AND FBGRESIDENTIAL CHAPTER 3. BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED WIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS. ULTIMATE WIND EXPOSURE B WIND EXPOSURE C WIND EXPOSURE D EMBED. WIND SPEED MAX SPAN, MAX MAX SPAN, MAX MAX SPAN, MAX DEPTH Vub (MPH) CANTILEVER CANTILEVER- CANTILEVER REQ. 170 40" O.C.11'-4' O.C. -: `1-07 O.C. , 414" O.C. 2'-0" O.C. , 9" O.C. 3" • FRECIEVED 3..2018., _ nty; Permitting - SCHEDULE REFLECTS COMPONENTS AND -CLADDING (C&C) NOMINAL WIND PRESSURES WITH EXPOSURE "B" - "C' - "DR, RISK CATEGORY II , ENCLOSED BUILDING AND h < 30'-0" PER ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2017 F.B.C. 6th ED ' LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. 3RD RAIL IS REQUIRED PER ROW OR COLUMN FOR SPECIFIED WIND SPEED AND EXPOSURE. INSTALLATION OF MODULES SHALL BE LOCATED IN ROOF WIND ZONE I AND 2. WIND ZONE 3 REQUIRES SITE SPECIFIC STRUCTURAL ENGINEERS APPROVAL 3 2 GABLE END BUILDING Cl ROOF WIND AREA ZONES 3 2 3 2 23 1�1 �teR� 1 �■RiRR9ERi raPw: � 3 2 HIP END BUILDING ROOF 0 WIND AREA ZONES m 4' TYP. L CONCRETE TILE OR COPMPOSITION SHINGLE ROOF FINISH TYPICAL PHOTOVOLTAIC ARRAY PITCHED ROOF LAYOUT - WIND ZONES - SCHEDULE - PLAN SCALE: NONE wm%b 1NO DESCRIPTION OTY, 1 ICA SCREW, SERRATED FLANGE, HEX HEAD5/16'-18 1 ' UNC-2A. GRAD NC 2 POST, 1-1/4' OD X 3-1/4', 1 6663-T5/6063-T6, MILL 3 WASHER, SEALING, /16' ID X 1-1/4' OD EPDM BONDED SS 1 4 FLASHING, REPLACEMENT TILE, 1 b25' CONE ALUMINUM MILL 5 LINT FLASHING, — 1-1/4'-ID-EPDM —1 6 V9RMTTEM,/1 , 111 X L' OD 18-8 SS L 7 18-8 SSUFTOT77m 1 8 HEAD X V UNC-2A 18-8 SS' 1 7 �A 6 'A AL ANGLE AVAILABLE IN RACKING COMPONENTS MILL, AND BLACK NOT INCLUDED FINISHES ` ` 3 �` 7 2 FLASHFOOT2 & QMOUNT TILE REPALCEMENT DETAIL m S.Y.P. 2X4 LOCATE BETWEEN TRUSSES AND NAIL WITH 2-16D NAIL PATTERN AT EACH END TO WOOD TRUSS 1111-0111111001 MISSED TRUSS CONNECTION DETAIL SCALE: 1 ;"=1'-0" #1 ST STL SELF TAPPING 12" ALUI.'� �!�'M INTERNAL SCREW TYP 4 PLCS PER BEAM SPLICE SPLICE BAR (USE WHEN __ SPUCE AT MID -SPAN W/ TYP XR100 ALUM RAIL TYP. TYPICAL SOLAR RAIL BEAM SPLICE DETAIL 5 SCALE: 1 �'=1'-0" $-01 CUT OUT OR REMOVE TILE TO INSTALL "ROOF ATTACHMENT. RE -FILL AND RE -SEAL TILES AFFECTED WITH APPROVED ROOF TIGHTEN TO TORQUE PER MANUF. INSTRUCTIONS PHOTOVOLTAIC MODULE TYP. IRONRIDGE MID OR ALUM L-FOOT TYP EACH END CLAMP STANDOFF 8" - 16 HEX CAP ST STL : _ IRONRIDGE XR100 BOLT AND ST STL RAIL SERRATED FLANGE NUT TYP. - ' -, QMOUNT TILE REPLACEMENT FLASHING AMOUNT TILE REPLACEMENT ATTACHMENT FLAT OR BARREL - - = ROOF TILES TYP. WOOD WOOD ROOF (2)16" ST STL LAG BOLT -SEE SHEATHING TRUSS TYP. SCH FOR EMBED DEPTH REQ. CONC TILE CONNECTION DETAIL 2 SCALE: 1 i"=1'-0" � END -CLAMP OR MID CLAMP S-01" T.-. 8" - 16 HEX CAP ST STL _--= BOLT AND ST STL IRONRIDGE SERRATED FLANGE -NUT XR100 TYP. TYP. PHOTOVOLTAIC' =-- ! MODULE TYP. - - =- COMPOSITION S.Y.P. 2X4 LOCATE BETWEEN -- SHINGLE/METAL —TRUSSES AND NAIL WITH - — ROOF (DET 2-16D NAIL PATTERN AT EACH OMITTED FOR END TO WOOD TRUSS CLARITY) (1)16" ST STL IRONRIDGE LAG BOLT - FLASHFOOT2 TYP. WOOD ----=" SEE SCH FOR SHEATHING —= WOOD ROOF EMBED DEPTH TRUSS TYP. REQUIRED 4 COMPOSITI N SHINGLE METAL ROOF FINISH 3 S-01 CONNECTION DETAIL SCALE: 12"=V-D" S-o1, COPYRIGHTED BY CASTILLO ENGINEERING SERVICES, LLC C a s t i H o Engineering DESIGNED TO PERMITS CASTILLO ENGINEERING SERVICES, LLC CAA 11 M45 2381 CREST RIDGE COURT SANFORD, FL 32771 T& 407474.91815 MORATES E WIM0-R PE 525M REVISIONS DESCRIPTION DATE REV PROJECT DEVELOPER SEP 2 1 2018 Signatm with SeDI - 9 O Z u- o LU �C orev -sgLUde ®ur Z �o V } N Q W W Z � las a SHEET NAME DATA SHEET SHEET SIZE ANSI B 1 111 X 1711 SHEET NUMBER 5-01 ST.LUCIE COUdHY PLAN REVIEW BLDG: DATE: _ ELE DAT � - - - PLUMB. DATE: t MECK