HomeMy WebLinkAboutPV MODULES ON IRONRIDGE RACKINGB M Ll Q o LU U I— d Z ru U E N U C7 z 3 0 3 0 n u D� a 00 aR 20 O. z ?�H Sze Wgo zog F�> >0u o�z 9 I 8 I 7 6 I 5 I 4 A,, 3 I 1 Ud RESIDENTIAL GENERICS URALPLAN. ICERTIFYTMATT�ESHEETNG&FRAMING OFT CTUREWILLSAFELY W (0 � DESIGNED FOR V _ 170 I ^r! COMMON SOLAR COMPONENf�ciwMPLES SHOWN - ACCOMMODATE CALCULATED WIND UPOFTA' ��L FGRCeSAND FBC 2017 (6TM EDITION) FLORIDA BUILDING CODE Z O V IY r f� ULT— 'v11 - NO PLANS ON FILE -EACH PERMIT REQv"iri" 3 SIGNED 8 ENGINEER APPEARANCE MAY VARY. EQUIPMENT DEAD LOADS.THIS DRAVANG AT THE TOE RI SIGNATUREAND SEAL O RISK it, EXPOSURE C. RAISED SEAL PLAN FROM FOR ON THIS DRAWING AT THE UPPER RIGHT. o ALLEN GEZELMAN IRONRIDGE-PV RAIrGENERICINSTALLATION PLAN - 1. THIS IS A SINGLE SHEET GENERIC STRUCTURAL PLAN INTENDED FOR --- - — GROUNDING PV MODULE GROUNDING MID -CLAMP MID -CLAMP 1sso2 HANNARD. - - LUTZ.FLORIDA 33549 --- A -- — - - - - - - ARRAYS IN ROOF PRESSURE ZONE PZ1, PZ2 & PZ3 REQUIRE SITE -SPECIFIC ENGINEERING. ELECTRICAL PLAN IS SEPARATELY SEALED DOCUMENT. PV RAIL PV RAIL 3/8 - 16 x 3/4 HEX HEAD BOLT PH.8139091956 Allen@GezelmanPE.00m Proper Flashing Placement 2. THIS PLAN OFFERS THREE INSTALLATION METHODS. 3/8-16FLANGE NUT www.GezelmanPE.com a. FRAMING METHOD. SEE DRAWINGS. v PE59180 I �; O Q I gf"c", b. SHEATHING METHOD. SEE DRAWINGS. C. STANDING SEAM/PBR (PURLIN-BEARING) METAL ROOF. USE CLAMP/BRACKET OF CHOICE; ACE. http://www.pmcind.com/aceclamp/ S-5. https://www.s-5.com/products/clamps-brackets/s-5-u-clamps/ L-FOOT ROOF TILE SS METAL PLATE, SQUARE OR ROUND ROO SHEATHING TYPICAL SHEETING-ONLY,SELF-FLASHING, SOLAR ROOF ATTACHMENT WITH OPTIONAL, REDUNDANT WATERPROOFINGAPPEARANCE MAY VARY -DIM SOR RND ETC. ��.. _ 1M.B 19 2919 --=_,:' I https://www.s-5.com/products/clamps-brackets/proteabracket/ EXISTING ASPHALT EXISTING FOAM `>�t ' v. 3. CONTRACTOR SHALL MAKE CLEAR TO AHJ WHICH INSTALLATION DETAILS SHINGLE ROOF FRAMING WILL BE USED. FLORIDAPRODUCTS DUCT ADHESIVE 4 MINIMUM APPROVED SEALANT _ - - ' nscmox¢vuwsstuu°tsvw 4. SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOAD TO STRUCTURE. #12X2-INCH, EXISTING FOUR # 14 CRS 9� COMPLETED LOSLOPE ATTACHMENT aWaLLSrA VVFA EL °S"YL SS, UNDERLAYMENT SCREWS I" BEYOND W-OPTIONAL REDUNDANT WP TARGET eEaavcuuaEaxnamsEu B 5. THERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMP AT EVERY BOTTOM OF DECK SELF FLASHING ATTACHMENT PHOTOS SHINGLE, TILE, SINGLE PLY FLAT TILE ROOF ATTACHMENT 10 SCAIE NTS MODULE/RAIL CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE. 03 9�E: ms 6U E: NT6 ADJOINING MODULES SHALL SHARE MID CLAMPS. MODULES MAY BE LANDSCAPE 3/8- 16x3/4 r DRAFTSMAN: OR PORTRAIT AT CONTRACTOR OPTION. HEX HEAD BOLT, PV RAIL 6. PV MOUNTING RAILS SHALL BE INSTALLED PERPENDICULAR TO ROOF IRONRIDGE 3/8-16 a A 12 0 ALPERICELI FLASHFOOT 2 FLANGE NUT alpedcell@mall.usf.edu FRAMING. SEE ROOF ATTACHMENTSPAN TABLE @ LOWER RIGHT SEE. FIGURE 11 I 7. THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PV MODULE. PV m — 8. RAILS SHALL NOT CANTILEVER BEYOND OUTSIDE OF END ROOF EXISTING MODULE ASPHALT d ATTACHMENT BY MORE THAN 1-FOOT SHINGLE 9. RAILS SHALL ATTACH TO ROOF THRU L-FEET AS SHOWN HEREON. L-FEET ROOF ° REVIEWED2 a E 1 SS PROTEA BRACKET / REQUIRE FLASHINGS WHICH CAN BE SHEATHING -ONLY PCM-PF6 CLIPS INSTALLED " = ss PROTEA DE �I,t.I I TOGETHER WITH PCM FLK-PF FLASHINGS SHOWN HEREON OR MIN 4" x 8" x 26 - BRACKET ROOF'Cl �Y EXSTING I r 0.032 ALUM, OR INDUST ATTACHMENTS LAGGED INTO ROOFR FRAMING, E.G. SOLAR MOUNT,STANDARD OEM FLASHINGSOVER IRONRIDGE SHEATHING FRAI MING META T� 1 E C� i 1 x � I L���� FLASHFOOT 1 OR 2, OTHER ACCEPTABLE TO AHJ. 5/16" CRS. LAG W/ 3" 6MM X 25 MM BI- PBR PROFILE 5/16 THREAD EMBEDMENT IN METAL SHEET SCREW IACE CLAMP (t"t 10. PCM PF-6 CLIP ATTACHMENTS ARE INTENDED TO BE INSTALLED INTO BLOCKING, JOIST, OR TRUSS THREAD `/ SHEATHING ALONE, HAVE BEEN SO TESTED AND ARE RATED AT 500-POUNDS EMBEDMENT z z FLASHFOOT 2SHINGLE ROOF ATTACHMENT SS PROTEA BRACKET METAL ROOF ATTACHMENT ��.-P� O ALLOWABLE PER ROOF ATTACHMENT. 9�LE:NTs De s�E:NT3 11. ALL FLASHINGS SHALL BE INSTALLED IN A GENEROUS BED OF FLORIDA �� IRON RIDGEFLASHF00T2 &� PROVED METALROOFCLAMPS B BRACKET PRODUCT CONTROL APPROVED (PCA) POLYURETHANE ROOF SEALANT. PV RAIL MID CLAMP STALE: NT6 SCA � J W Q 12. LONG L-FEET &/OR STANDOFFS ARE PERMITTED AS NEEDED FOR ROOF EXIST. 3/8 - 16 x 3/4 HEX HEAD BOLT PV RAIL CLEARANCE. ROOF TIAq- 3/8- 16 FLANGE NUT 13. ENGINEER OF RECORD (EOR) PREFERS EMAIL COMMUNICATION: --- ---- PV MODULE _ _ alien@gezelmanne.COm!1ENGINEERING NOTES. — — — EXIST. METAL 2 PCM PF6 CLIP PV RAIL ISOMETRIC VIEW TO BE INSTALLED TOGETHER WITH PCM FLK-PF FLASHING (NOT SHOWN) O PCM PF6 CLIP TOP VIEW MID -CLAMP 3/8 - 16 X 3/4 HEX HEAD BOLT �` 3/8 -16 FLANGE NUT PV RAIL PCM PF6 CLIP LOCFAST # 14 WOOD FASTENERS EXTENDING MIN. 1-INCH BELOW ROOF SHEATHING. ROOF EXISTING PCM FLK-PF EXISTING SHEATHING I 1 FLASHING UNDERLAYMENT PCM PF-6 CLIP ROOF ATTACHMENT S PCM FLK-PF FLASHING STALE: NTs 8 7 DECKING SERRATED L ON ROOF ROOF MOUNT SHEATHING e e v ROOF SHEATHING 1 OPTIONAL FILL CAVITY WITH WATER TILE ROOF DOW FOAM PROOFING STANDOFF WATER PROOFING OR LONG WITH SONOLA517C EXISTING FRAMING L-FOOT MIN. 4 #14 X 2" SMS -SS NP-1 OR EQUAL 5/16" CRS. LAG W/ 3" THREAD EMBEDMENT 1" BEYOND BOTTOM OF DECK POLYURETHANE CAULK IN BLOCKING, JOIST, OR TRUSS 1FRAMING-METAL ROOF ATTACHMENT; BARREL TILE ROOF ATTACHMENT r, ROOF COVERING COULD BE SHINGLE,TILE, OR SINGLE -PLY. swe: rns l 08j,suU nits ,Flat Roof Hip <6527°) Gable Roof(857°) Gable Roof PZ1: ROOF INTERIOR PZ2: ROOF PERIMETER (MIN. 3' & LEAST OF 40% EAVE HEIGHT OR 10% BUILDING LAN. PZ3: OUTSIDE CORNERS L & W = PZ2, a = PZ2 WIDTH., h = EAVE HEIGHT. gCE 7-10 COMPONENT 8 CLADDING WIND PRESSURE ZONES. 09 IE; NiS. 5 4 A low -profile mounting call The ultimate reeldential A haavywalght mounting Ali ralle use Internal splices for regions with fight snow. solar mounting rall. rag for commercial projects. for seamless connections. • 8'spanning eapablllty • 81 spanning capability • 12'spanning capability • Bell-drlllIng screws • Moderate load capability • Heavy load capability • Extreme load capablMy • Varying veralons for calls • Clear and blade flnieh • Clear and bleak flnieh • Clear anodized finish • Forms secure bonding UFOs StopperSleoves grounding Lugs hllicrotnvseterl0h flI FNshFocts SlotW L-Feet Sending Hardware 'ff ftnlfh % FLORIDA ROOF ATTACHMENT SPACING (FEET): ROOF HEIGHT < 30 FT !Ak WIND (MPH) PZ1 PZ2 PZ3 jQf&RML-- 110 8 6 4 XR-10 120 8 6 2 0 130 2 140 r 4 2 R-100 150 p _' 4 2 4 2 XR-1000 0 4 4 XR-1000 180 3 ROOFMOUNT SYSTEM COMPONENTS 01 J = D W M O� i2 p CONTRACTOR: V_EH S nk Efficient Home Services 4897 W Waters Ave (SWte E) Tampa, FL 33634 Phone 844.77M 10 Emall seMceQehs6.com It E C AHR-EHSF 18.DEC.18 F 1