GENERATOR ADDITION RISER DIAGRAM
ABBREVIATIONS: ELECTRICAL LEGEND: (SOME SYMBOLS SHOWN MAY NOT PERTAIN TO THIS PROJECT) GENERAL NOTES: AC^ - _ALTERNATING CURRENT MDP MAIN DISTRIBUTION PANELBOARD__ - 1. LIGHT LINE WORK REPRESENTS EXISTING TO REMAIN. A/C AFG AIR CONDITIONING ABOVE FINISHED GRADE MTS MLO MANUAL TRANSFER SWITCH MAIN LUGS ONLY �_ SURFACE MOUNT 120/204V, 10, 3 WIRE PANELBOARD _ - FRAME SIZE - - 30AR�� -- -- - - 2. DARK AND RED LINE WORK REPRESENT NEW AL ALUMINUM NEC NATIONAL ELECTRICAL CODE NF 3R-- NEMA RATING NON -FUSED DISCONNECT EQUIPMENT, CONDUIT, AND WIRE. AHU AIR HANDLING UNIT NTS NOT TO SCALE FLUSH MOUNT 120/204V, 10, 3-WIRE PANELBOARD NON FUSED ATS AUTOMATIC TRANSFER SWITCH NEMA NATIONAL ELECTRICAL MANUFACTURERS AMP AMPERE ASSOCIATION FRAME SIZE 30AR CONDUIT AND WIRE SCHEDULE AFCI ARC FAULT CIRCUIT INTERRUPTER NFPA NATIONAL FIRE PROTECTION ASSOCIATION _� SURFACE MOUNT 277/480V, 30, 4-WIRE PANELBOARD r7IJ 3Rl f NEMA RATING FUSED DISCONNECT � ANSI AMERICAN NATIONAL STANDARDS INSTITUTE NON -SE NON SERVICE ENTRANCE RATED -�- FUSE SIZE SYMBOL DESCRIPTION C CONDUIT P PLACES (QUANTITY) CU COPPER CONDUCTOR PNL NL PANEL -Q- FLUSH MOUNT 277/480V, 30, 4WIRE PANELBOARD O (EXISTING) 2-PVC UNDERGROUND SERVICE FEEDER COVE CITY OF VERO BEACH PVC POLYVINYL CHLORIDE CONDUIT GENERATOR AND GENERATOR PAD (EXISTING)1/2"PVC #4 BARE CU DC DIRECT CURRENT RMC RIGID METAL CONDUIT ® DISC DISCONNECT RTU ROOF TOP UNIT 2-PVC W/ (4) #6 THHN CU, (1) #6 THHN CU GROUND -EXIST EXISTING _ ______ __ _ SE. SERVICE_ENTRANCE.RATED UTILITY METER CAN OR METER/MAIN COMBO UNIT FPL __ FLORIDA POWER & LIGHT _ _ TYP TYPICAL GAS STORAGE TANK - - - - 2"-PVGWF(3p#2/0-THHN CU - G GFCI GROUND GROUND FAULT CIRCUIT INTERRUPTER TEMP UG TEMPORARY UNDERGROUND C5;Z__1- SURFACE MOUNT AUTOMATIC TRANSFER SWITCH 0 2-PVC W/ (3) #7JO THHN CU, (1) #6 THHN CU GROUND IRC INDIAN RIVER COUNTY UL UNDERWRITERS LABORATORY © 2-PVC W/ #3/0 THHN CU, (1) #6 THHN CU GROUND KVA KILOVOLTAMPERE UON UNLESS OTHERWISE NOTED POINT OF NEW CONNECTION ® NATURAL GAS METER KW KILOWATT V VOLT © 14WPVC W/ (3) #3 THHN CU, (1) #6 THHN CU GROUND MC METAL CLAD CABLE VA VOLTAMPERE MCB MAIN CIRCUIT BREAKER W WATT ® 3/4"PVC W/ BELDEN CONTROL CABLE MCC MOTOR CONTROL CENTER XFMR TRANSFORMER O 1/2-PVC W/ (1)94 BARE CU NOTE: NOT ALL CONDUIT AND WIRE SHOWN ON THIS SCHEDULE MAY PERTAIN TO THIS PROJECT. (E) SCOPE OF WORK: • INSTALL200AMP MAIN BREAKER PANEL WITH FEED THROUGH LUGS INSIDE GARAGE BACK TO BACK FROM EXISTING UTILITY METER. • RELOCATE EXISTING TANK LESS WATER HEATER CIRCUIT TO NEW PANEL. • INSTALL20DAMP NON SERVICE ENTRANCE RATED KOHLER RXT ATS BELOW NEW 20DAMP PANEL AND EXISTING HOUSE PANEL • INSTALL COLD WATER BOND FROM ATS TO NEAREST CU WATER PIPING. • FORM AND POUR CONCRETE PAD FOR GENERATOR. • PROVIDE AND INSTALL (1) 20kW KOHLER LP GAS GENERATOR WITH COMPOSITE HOUSING. • PROVIDE AND INSTALL CONDUIT AND CONDUCTORS FOR FROM ATS TO GENERATOR. • LOAD SHED PER SIZING DATA THIS SHEET. • GENERATOR LP GAS CONNECTION BY FERRELLGAS AS A SUBCONTRACTOR UNDER THIS PERMIT. • NEW LP TANK TO BE PROVIDED AND INSTALLED BY FERRELLGAS UNDER A SEPARATE PERMIT. • NO NEW BRANCH CIRCUIT LOADS SHALL BE ADDED TO HOUSE PANEL UNDER THIS SCOPE OF WORK. GENERAL NOTES: • THE ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL SERVICIJ ROUGH IN AND INSTALLATION DETAIL WITH THE LOCAL UTILITY POWER COMPANY. • THIS ELECTRICAL INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017), LOCAL ORDINANCE, AND THE NATIONAL ELECTRIC CODE THIRTEENTH EDITION NFPA 70 (2014). • ALL ELECTRICAL WORK FOR THE ENTIRE PROJECT SHALL BE PERFORMED IN A NEAT AND CRAFTSMAN LIKE MANNER BY PERSONS SKILLED IN THE ELECTRICAL TRADE, AND SHALL BE DONE UNDER THE SUPERVISION OF MASTER ELECTRICIAN LICENSED IN THE STATE OF FLORIDA. • THIS ELECTRICAL INSTALLATION SHALL BE PROTECTED FROM PHYSICAL DAMAGE AND SEC RELY SUPPORTED AND FASTENED, WITH WORKING SPACE PER NEC 11026. • PVC SCHEDULE 40 CONDUIT SHALL BE USED UNDERGROUND, IN OR BELOW CONCRETE AND WHERE EXPOSED NOT SUBJECT TO DAMAGE. PVC SCHEDULE 80 CONDUIT SHALL BE USED WHERE EXPOSED, SUBJECT TO DAMAGE. • ALL MATERIAL SHALL BE NEW, FREE FROM DEFECT AND SHALL BE LISTED AND BEAR THE LABEL OF A RECOGNIZED TESTING LABORATORY. I • GROUNDING PER NEC ARTICLE 250. • STANDBY SYSTEM INSTALLATION PER NEC ARTICLE 702, AND MANUFACTURER INSTALLATION INSTRUCTIONS. LOAD MANAGEMENT I "LCM" LOAD SHED LOAD MANAGEMENT TECHNOLOGY ALLOWS THE LOAD CONTROL MODULE TO MONITOR GENERATOR PERFORMANCE AND ONLY SHED LOADS WHEN ABSOLUTELY NECESSARY BY MONITORING GENERATOR CURRENT AND FREQUENCY. BY ONLY SHEDDING THE NONESSENTIAL CIRCUITS, THE ESSENTIAL CIRCUITS ARE ALWAYS POWERED. LOADS ARE SHED THROUGH INTERRUPTION OF INDIVIDUAL CONTROL CIRCUITS (AHU/AC) AND POWER CIRCUITS (RANGE AND WATER HEATER). GENERATOR ADDITION RISER DIAGRAM KOHLER. GENERATORS COMPLETE ELECTRIC INC. 637 SEBASTIAN BLVD. SEBASTIAN, FL 32958 (772)388-0533 /O CANNFID .Sizing Report a-V st Lucia County Rated Nominal Voltage 240 Generator Fuel Choice Propane Sizing Method (NEC 220) Part IV (Part III required for selected circuit implementation, Both valid for whole house) General Lighting & Receptacles Load (kW) Square Footage Being Covered (ftA2) 2000 6 Small Appliance Circuits (20 amps) , Kitchen Circuits 2 3 Laundry Circuits 1 1.5 Managed Estimated Nameplate Fixed -In -Place Appliances & Motors Loads (kW) (amps) 240 V Load (kW) Dryer 5.5 X 5.5 Microwave 1.3 1.3 Cook Top X 3.0 X 0.0 Oven 5.0 X 5.0 Pool Heater X 5.0 X 0.0 Dishwasher 1.5 1.5 Freezer 0.8 0.8 Refrigerator 0.8 0.8 Pool Pump 2.0 2.0 Refrigerator 0.8 0.8 , Pool Pump 2.0 2.0 Pool Pump 2.0 2.0 Managed Estimated Nameplate Air Conditioning & Cooling Loads (kW) (amps) 240 V Load (kW) 3.0 Ton Unit X 3.0 X 0.0 Managed Estimated Nameplate Heating & Heat Pumps Loads (kW) (amps) 240 V Load (kW) Heat Pump (3 Ton) X 3.0 32 X 0.0 Estimated Actual Utilized Transient Requirement (LRA) (LRA) (LRA) Largest Motor's Starting Amps (LRA) 221 77 77 Load NEC Summary NEC Load (kW) Required General Lighting & Receptacles 10.5 Fixed -in -Place Appliances & Motors 21.7 Sum of all General Loads 32.2 18.9 Cooling 0 0 Heating (w/demand factors) 0 0 Larger of Heating & Cooling 0 0 Sizing based on requirements of NEC Article 220, Part IV 18.9 Elevation 0 it Minimum size generator for motor sterling requirements 11 BTU load required 324000 20 kW Kohler Model Generator Recommended z «< < Do r. 1.0 UD'N Z Ih t7 U Q '� o LL WQZcco o I- LU J I" a v m f0 W O co LLJ J 4K, Up off W QO WO0 Z P 5 W 5 ❑ C7 p Q 0 co LL 3 0 =) �W 2 LL C n C.) W It Z W w�?a �gCD� W 00 Z 0) LL E1 rA 09/26/2018 Sirr' 1 OF 2 I SINGLE FAMILY \ RESIDENCE i909 S. INDIAN RIVER DR FORT PIERCE, FL. 34982 (NEW) 200AMP FEED THROUGH PANEL PROPERTY LINE 891.41' N 1 '- _1 101-011GENERATOR SITE PLAN W E S PROPERTY LINE 90.00' +/ PROPERTY LINE 95.00' +/- DRILL CLEAN DRIVE TIGHTEN 35 X DRILL 1/4" DEEPER THAN •.. .'. •.:. ...... .'. a q' ANCHOR EMBEDMENT ' 1/4" MI . .' . :` 54' DRILL BIT SIZE:1/2" 'TIGHTENING MIN. ANCHOR TORQUE:45ft.lbs. EMBEDMENT.2-1/2" NOTE: THE USE OF A CARBIDE DRILL BIT CONFORMING TO ANSI STANDARD B212.15 IS RECOMMENDED. �34"� TOP VIEW ® 6" MIN. 34" 54" �{ LEFT ELEVATION FRONT ELEVATION 1,2"�1'-o„ GENERATOR PAD DETAIL }� z Zco uo N �ZV) U Q J o' Ll. J Z m WmgN w U C m � co W O LLJ a �� �a w ro O m LLwW 0=)— �orz U)ZZLu w� Z 9 W ELI W�o0 Z MO E2 ,A 09/26/2018 "FF- 2OF2