Nutting Engineers of Florida, Inc. has performed geotechnical engineering services
for the referenced project. The area between the house and the proposed pool was
probed with a Static Cone Penetrometer to determine the level of compaction of the
backfill material. Three probes were performed at the following locations:
1) North elevation of the pool area.
2) South elevation between the house and pool.
3) East elevation of the pool area.
It is our opinion that the pool backfill as indicated by the above test locations has
been compacted to a density of the order of 95 percent modified Proctor.
We appreciate this opportunity to be of service. Should you have any questions,
please contact our office at your convenience.
Respectfully Submitted,
NUTTI OIROgRS OF FLORIDA, INC.: