Loading...
HomeMy WebLinkAboutBUILDING SITE PLAN0 --------------------- ---- ------------------------ I 12"x12" REINFORCED FOOTER i I 1 I I I I I i i I I - A I -TO BE TER ITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA BUILDING CODE, 6TH EDITION I R - INI U 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS I I REINFORCING STEEL (REBAR) REQUIREMENTS: -MINIMUM GRADE 40 STEEL -REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED: -THE REBAR IS BENT COLD I -THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6-BAR DIAMETERS: AND -REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED TO BE BENT TO ALIGN WITH A VERTICAL CELL THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1" HORIZONTALLY TO 6" VERTICALLY.- -COVER: -3" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND 1 " ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR I DISTANCE OF J" FOR FINE GROUT, AND }" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL REBAR USED IN MASONRY WALLS SHALL HAVE A MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR WEATHER, AND 14" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER. A ETAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND I NAILS EXPOSED DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. I SWINGING DOOR I I I I I I I I I I I I L--------------------------- FRAME ---------------- OUT —3'-0" 1 O'-0" 2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER MESH) AND 12"x12" REINFORCED FOOTER PERIMETER }"x3"(2,500 LB.) CONCRETE WEDGE ANCHOR WITHIN 6" OF EACH, POST. A___, 2}" EMBEDMENT MIN. 2" MIN. BASE RAIL GRADE - ::.. - - - III ::'Z ( a I...I...I_ I"6" IA° N 2,500 PSI 4" CONCRETE "d I o SLAB WITH W.W.F. OR FIBER MESH �12" (2) #5 REBAR ® 6" O.C. MINIMUM SOIL BEARING CONTINUOUS WITH MINIMUM CAPACITY 2,000 PSF (TYP.) 12"' OVERLAP SPLICE CONCRETE FOUNDATION/BASE RAIL ANCHOR DETAIL PLAN VIEW 2 5" BUILDING FRAMING " RECESS 2If . 3" DOOR WIDTH ELEVATION VIEW BUILDING FRAMING RECESS T" 75"J I DOOR WIDTH ROLL —UP DOOR CONCRETE SPLASH —GUARD RECESS t__3'-0" - — FRAME RECEIVED ST: Woe 16/v - ST, LUOYF eOUt4V/ REVIEWED FOR CO' REVIEWED S . DATE pLANS ANNO Sp IONS) W SITE OR I OCT 11 ,2018 ON 305 BE MADE i i I I I SWINGING DOOR I I I I FILE_C�PY ';� 1 0' CODE VERSION FBC 2017 6th Edition, ASCE- MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II-B FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES I BASIC WIND SPEED Vw-165mph EXPOSURE C ENCLOSURE ENCLOSED / OPEN INTERNAL PRESSURE COEFFICIENT +/— 0.18 / 0.0 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 20PSF OR 3001b POINT LOAD FLOOR DEAD LOAD IOPSF "R" RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE IND HURRICANE SHELTER USAGE NO SQUARE FOOTAGE I 2,080 SO. FT. REVISIONS REV DESCRIPTON DATE 1 1CORRECTED LEAN—TO DETAIL 9/11/18 Dro*n By: MTB Date: 9/10/18 Mocati n rcl �409-114-0004-000-2 Ft Pierce 3498 Model ; 401 X 20/16/16-W 'X 14/10'H ^ENERAL NOTES I. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 1015.22. 2 ALL STEEL TUBING SHALL BE 50 KSI STEEL 3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 4. ROOF AND WALL SHEATHING SECURED WITH #12-14x1" SELF -DRILLING SCREWS WITH SEAL WASHERS 0 6' O.C. MAX. 5. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF -DRILLING SCREWS. 6_ ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. 7. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2"x3", 2,50OL13 TENSILE STRENGTH. 5.14GA FRAMING IS 2.5"x2.5' TUBE STEEL NIPPLES ARE 225"x2.25' TUBE STEEL 0 z i 9/12/18 _LJ z MattheW T. BaldWin P.E. Q Florida License #664608 a Sheet: CA-1 01 6 O O I O -12 Q3 - - - - - — y - - CAMRBANMene CODE INFORMATION CODE VERSION F8c 2017 6th Edition. ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE �b 3'-7F"' 3'-7 3'-7 OCCUPANCY STORAGE I ALLOWABLE NUMBER OF STORIES 1 10'-0" O 10'-0" ED BASIC WIND SPEED Vr 165mph EXPOSURE C ENCLOSURE ENCLOSED /OPEN INTERNAL PRESSURE COEFFICIENT +/— 0.18 / 0.0 IMPORTANCE FACTOR 1.15 0 _ O I ROOF DEAD LOAD fOPSF ., O ROOF LIVE LOAD 20PSF OR 30015 POINT LOAD FRAME FRAME FLOOR DEAD LOAD IOPSF OUT OUT 'R' RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 12 GA. POST 12 GA. POST HURRICANE PROTECTION USAGE NO (EACH SIDE OF ALL ROLL -UP DOORS) (EACH SIDE OF ALL ROLL -UP DOORS) HURRICANE SHELTER USAGE INO SQUARE FOOTAGE 2,080 SQ. FT. J REVISIONS 16'-0" I-3'-0"� 20'-0" 3'-0-3'-0" 16'-0'• -� REV DESCRIPTON DATE BY 1 CORRECTED LEAN—TO DETAIL 9/11/18 MTB FRONT END WALL 12 Q3 Drc*n By: MTB Date: 9/ 10/ 18 Locati n• rcl �409-114-0004-000-2 Ft Pierce 3498 odel : 40'L X 20/16/16'W X 14/10'H - GENERAL NOTES 1. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 1015.22. 2_ ALLSTEEL TUBING SHALL BE 50 KSI STEEL 3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER 4. ROOF AND WALL SHEATHING SECURED WITH Q72-14x1' SELF—DRIWNG SCREWS WITH SEAL WASHERS ® 6' O.C. MAX. - 3'—% " 3'—% " 3'—% " " I 5.FIEUD SELF—DFRRIWING CONNECTIONS SECURED WITH 812-14x3/4' 6, ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. MINIMU M 0'-O 1" �p 7.CONCRETE EXPANSIONS ANCHORS ARE TO BE 1/2'x3', 2,50OLB TENSILE STRENGTH. 8.1FRAMING IS 2.5x2.5' TUBE STEEL NIPPLES ARE " 2.25'x2.25' TUBE STEEL O O W I I O \ / FRAME OUT 0 z 12 GA. POST (EACH SIDE OF ALL ROLL-UP DOORS) Q ly— LL- / I --3'-0 REAR END WALL Of 9/ 12/ 1 8 z Matthew T. BOIdWin P.E. 0 Florida License #64608 Sheet: CA-2 OF 6 LL_ 1= LEFT/RIGHT MAIN SIDE WALL CO 1 3'-0" SWINGING DOOR 1 _24 —11 3'-11j" 3'-11 3'-11 3'-11 3'—itj" 3'-11 LEFT SIDE WALL (RIGHT SIDE- IS MIRRORED) CODE VERSION FBC 2017 6lh EdRTOn. ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE CONSTRUCTION TYPE II-B FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES 1 BASIC WIND SPEED Va-165.ph EXPOSURE C ENCLOSURE ENCLOSED / OPEN INTERNAL PRESSURE COEFFICIENT +/— 0.18 / 0.0 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 20PSF OR 3001b POINT LOAD FLOOR DEAD LOAD 10PSF "R" RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 2,080 SO. FT. REVISIONS REV I DESCRIPTON � DATE I BY 1 1CORRECTED LEAN—TO DETAIL 9/11/18 MTB urown eyc MTB Date: 9/10/18 Locati n rcl �409-114-0004-000-2 Ft Pierce 3498 Model : 401 X 20/16/16'W X 14/10-H - GENERAL NOTES 1. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 1015.22. 2. ALL STEEL TUBING SHALL BE 50 KSI STEEL 3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 4. ROOF AND WALL SHEATHING SECURED WITH /12-140" SELF—DRIWNG SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 5. FIELD FRAMING CONNECTIONS SECURED WITH 812-14x3/4" SELF—DRIWNG SCREWS. 6. ALL SHOP FRAMING CONNECTIONS ARE TO BE 1YELDED. 7. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2"x3", 2.50OLB TENSILE STRENGTH. 8.14GA FRAMING IS 2.5"x2.5' TUBE STEEL. NIPPLES ARE I /'1 225'x225' TUBE STEEL V / :i w z Q Q 9/12/18 W MattheW T. BOIdWin P.E. Q Florida License #664608 (n Sheet: CA-3 OF 6 12 Q3 ' Ago CAMUSANYMME - CODE INFORMATION CODE VERSION FBC 2017 6th Edition, ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE j O O I ' • ' O r^K`1 O I. I CONSTRUCTION TYPE II—B FIRE PROTECTION NONE NONE FIRE SUPPRESSION SYSTEM OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES 1 - BASIC WIND SPEED Vr-165mph EXPOSURE C FRAME OUT _ FRAME OUT ENCLOSURE ENCLOSED / OPEN INTERNAL PRESSURE COEFFICIENT +/— 0.18 / 0.0 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 20PSF OR 3001b POINT LOAD FLOOR DEAD LOAD 1OPSF "R" RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 2.080 SQ. FT. REVISIONS REV DESCRIPTON DATE BY 1 CORRECTED LEAN—TO DETAIL 9/11/18 MT8 FRONT END WALL 12 Q3 • ^ACV to O 1 O O p FRAME OUT W Q W Drohn By: MTB Date: 9/10/18 Locati n rcl3409-114-0004-000-2 Ft Pierce 3498 Model : 40-L X 20/16/16'W X 14/10-H GENERAL NOTES 1. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 1015.22. 2. ALL STEEL TUBING SHALL BE 50 KSI STEEL. 3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 4. ROOF AND WALL SHEATHING SECURED WITH #12-140" SELF —DRILLING SCREWS WITH SEAL WASHERS m 6" O.C. MAX. 5. FIELD FRAMING CONNECTIONS SECURED WITH #12-14x3/4" SELF—DRILUNG SCREWS. 6. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. 7. CONCRETE EXPANSIONS ANCHORS ARE TO BE MINIMUM 1/2"x3", 2,500LB TENSILE STRENGTH. 8. 14GA FRAMING IS 2.5x2.6" TUBE STEEL. NIPPLES ARE 2.25"x2.26" TUBE STEEL - REAR END WALL z 0 9/12/18 Matthew T. Baldwin P.E. Florida License #64608 Sheet: CA- 4 0 F 6 CARPORTSANYWHERE CODE INFORMATION CODE VERSION FBC 2017 6th Edition, ASCE-7-10 MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE -� _ COFSTRUCTION TYPE IF—B FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES 1 BASIC WIND SPEED Va-165mph EXPOSURE C ENCLOSURE ENCLOSED / OPEN INTERNAL PRESSURE COEFFICIENT +/— 0.18 / 0.0 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD 10PSF ROOF LIVE LOAD 2OPSF OR 3001b POINT .LOAD FLOOR DEAD LOAD 1OPSF "R" RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 2,080 SQ. FT. REVISIONS REV DESCRIPTON DATE BY 1 CORRECTED LEAN—TO DETAIL 9/11/18 MTB LEFT/RIGHT MAIN SIDE WALL Drawn By: MTB Date: 9/10/18 rcl 09-114-0004-000-2 Ft Pierce 3498 0.VF�4n octal : 40'L X 20/16/16'W X 14/10'H GENERAL NOTES 1. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 1015.22. 2. ALL STEEL TUBING SHALL BE 50 KSI STEEL 3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET —BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 4. ROOF AND WALL SHEATHING SECURED WITH'12-14x1" SELF —DRILLING SCREWS WITH SEAL WASHERS ® 6" O.C. MAX. 5. FIELD FRAMING CONNECTIONS SECURED WITH #12-143/4" SELF—DRILUNG SCREWS. 6. ALL SHOP FRAMING CONNECTIONS ARE TO BE YIELDED. 7. CONCRETE EXPANSIONS ANCHORS ARE TO BE MMINIMUM 1/2"x3", 2,500LB TENSILE STRENGTH. 8.14CA. FRAMING IS 2.5x2.5" TUBE STEEL NIPPLES ARE 2.25"x226" TUBE STEEL SWINGING DOOR LEFT SIDE WALL (RIGHT SIDE IS MIRRORED) to Li > Q W Q LI (n 9/12/18 Matthew T. Baldwin P.E. Florida License #64608 Sheet: CA-5 OF 6 MINIMUM 6" TS NIPPLE. NIPPLE MINIMUM 6" TS NIPPLE NIPPLE SECURED TO WALL POST WITH SECURED TO WALL POST WITH (4)#12-1414' SELF -DRILLING SCREWS 1r (4)e12-14x)' SELF-DRIWNG SCREWS IPPLE TO NIPPLE TO 2"x2"x2' 16 GAL ANGLE CUP SECURED BASE RAIL BASE RAIL WITH (4) 012-14x4" SELF-DRIWNG SCREWS - _iil��Ilil1�1 III- -'ll POST TO TO BASE RAIL CONNECTION MINIMUM 6' TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14x3" SELF-DRIWNG SCREWS kSELF-DRILUNG xV 16 GA ANGLE CLIP RED WITH (4) 812-14xf1" 2"x2"x2" 16 GA ANGLE CUP SECURED SCREWS WITH (4) #12-14x(" SELF -DRILLING SCREWS GLE OR DOUBLE TS HEADER SINGLE OR DOUBLETS HEADER NIPPLE TO RACF RAII INTERMEDIATE POST TO END POST TO BASE RAIL HEADER/BASE RAIL/OR HEADER CONNECTION CONNECTION WINDOW RAIL DETAIL DETAIL OPTION 1 2"x2%2" 16 GA. ANGLE CLIP SECURED WITH (4) #12-14xj" SELF -DRILLING 'SCREWS 16 GA. ANGLE CLIP WITH (4) #12-14x1" LUNG SCREWS NON—STRUCTURAL HEADER OR WINDOW RAIL TO POST DETAIL 26 GAUGE ROOF SHEATHING SECURED WITH (1)#12-14,1" SELF-DRIWNG SCREWS ® 6" O.C. (9' O.C., MAX.) 1' 16 GAUGE FURRING CHANNEL 48' O.C. MAX SECURED WITH (2)012-14x1" SELF-DRIWNG SCREWS TO EACH RAFTER. ROOF PANEL CONNECTION VERTICAL SHEATHING OPTION HEADER CONNECTION DETAIL OPTION 2 NIPPLE TO RAFTER MINIMUM 6'_ TS NIPPLE NIPPLE SECURED TO WALL POST WITH (4)812-14x4' SELF-DRIWNG SCREWS POST TO TRUSS CONNECTION CODE VERSION FBC 2017 6th Edition, ASCE- MANUFACTURER CARPORTS ANYWHERE BUILDING TYPE UTILITY STRUCTURE - - CONSTRUCTION TYPE - 11-B- - - -- FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STORAGE ALLOWABLE NUMBER OF STORIES - 1 BASIC WIND SPEED V.-165mph EXPOSURE C ENCLOSURE ENCLOSED / OPEN INTERNAL PRESSURE COEFFICIENT +/- 0.18 / 0.0 IMPORTANCE FACTOR 1.15 ROOF DEAD LOAD IOPSF ROOF LIVE LOAD 20PSF OR 3001h POINT LOAD FLOOR DEAD LOAD 1OPSF "R" RATING OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 ' HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SQUARE FOOTAGE Z080 SO. FT. INSTALL PER MANUFACTURERS INSTRUCTIONS 26 GA RIDGE CAP #12-14.4' SELF-DRIWNG SCREWS O 1a' O.C. MAX., 3" MAX. FROM CORNERS HORIZONTALLY/ 4" MAX. FROM 8141" SELF-DRIWNG SCREWS O 6" D.C. MAX. & 6" MAX. FROM CORNERS NIPPLE TO RAFTER MAIN STRUCTURE POST/TRUSS 3" (.ONE CORNERS VERTICALLY 26 GA ROOF SHEATHING MINIMUM 6" TS NIPPLE NIPPLE INTERIOR EXTERIOR ��•� 26 GAUGE ROOF SHEATHING SECURED SECURED TO WALL POST WITH (4)d12-14x3" SELF-DRIWNG SCREWS TYP DOOR FRAME TO POST ROLL —UP DOOR. TO POST CONNECTION WITH (1)#12-144' SELF-DRIWNG SCREWS ® 9' O.C. MAX. ROOF RIDGE CAP REINFORCEMENT BOX EAVE RAFTER TO LEAN—TO OVER 14' CONNECTION DETAIL CONNECTION POST CONNECTION DETAIL DESIGN PRESSURES — 165 Mph ROOF +23.3/-51.6 WALLS +27.2/-25.8 DOORS +27.2/-25.8 WINDOWS +27.2/-25.8 1 2 3 4 5 ZONE +12.0 —26.8 +14.9 —40.7 +23.3 —51.6 +27.2 —25.4 +25.8 —22.4 1 'J r A P (l CT / APPROVED PRODUCTS APPROVAL NO. ROOF SHEATHING Carolina Carports, Inc. FL6596.1 26 Ga. AG Roof Panel WALL SHEATHING Carolina Carports, Inc. FL6702.3 26 Ga. Dutch Lap SWINGING DOOR ELIXER DOOR AND METAL COMPANY FL17996.5 407 STEEL DOOR I I CORRECTED LEAN-TO DETAIL 1 x/" / i I — II Urown By: MTB Date: 9/10/18 LocaU n 'rcl409-114-0004-000-2 Ft Pierce 349E Model : 40-L X 20/16/16-W X 14/10'H GENERAL NOTES 1. THIS BUILDING IS EXEMPT FROM THE FBC ENERGY CONSERVATION CODE PER SECTION 101522. 2. ALL STEEL TUBING SWILL BE 50 KSI STEEL 3. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, AND/OR OTHER LOCAL CODE REQUIREMENTS ARE THE RESPONSIBILITY OF THE OWNER. 4. ROOF AND WALL SHEATHING SECURED WITH 812-14x1" SELF-DRIWNG SCREWS WITH SEAL WASHERS ® 6" O.C. MAX 5. FIELD FRAMING CONNECTIONS SECURED WITH (112-14x3/4" SELF-DRIWNG SCREWS. 6. ALL SHOP FRAMING CONNECTIONS ARE TO BE WELDED. 7. CONCRETE EXPANSIONS ANCHORS ARE TO 'BE MINIMUM 1/2"x3", 2,500LB TENSILE STRENGTH. 8.14GA FRAMING IS 2.5"x2.5' TUBE STEEL NIPPLES ARE 225'x226" TUBE STEEL... CAM 9/ 12/ 18 U) J Q Matthew T. Baldwin P.E. Florida License #64608 Ld o Sheet: CA-6 OF 6