HomeMy WebLinkAboutPRODUCT APPROVAL - 1 INCH NAIL STRIP - 10-9-18FILE C 1 c r�v%%-' I 2160 SW Poma Drive Palm City, FL 34990 jj3to'ot Compliant with Florida Building Code 2017 (611 ed.) ST. LUCIE COUNTY BUILDING Compliant with Florida Product Approval Rule # 61G20-3tEVIEWEEpED FOR COMPLIANC Compliant: Keystone Certifications DATEREVIE1 U o � PLANS AND PERMIT MUST BE KI SITE OR NO INSPECTIONS) WI Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec.1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" JJOB MADE SCANNED) By St Lucie County Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru bottom of support. Adhesive/Sealant : Bostik 9151 Chem -Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 CONCEALED FASTENERS OR ATTACHMVTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OR RECORD Slope: Shall be in compliance with FBC Sec.1S07. 1 Install Details: Table A Allowable Loads METHOD 1 METHOD 2 (' DESIGN PRESSURE* _f86 PSF Main tell 97.25 PSF Perimeter FASTENER SPACING 6 O.C. _. __. - Ir O.C. ry YW SEAM ADHESIVE Not required 3/16» continuous bead Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2 ULI897-04 is equivalent to Test Standard ULI897-12. Certificate of Independence: ' Locke Bowden, P.E. does not have, not will acquire a financial W@mItbttagy�company manufacturing or distributing products under this evaluation. ����� D • BO Locke Bowden, P.E. is not owned, operated, or controlle mR r, ►any'aurer, or distributing products under this report. .' �• '� 12 • '� seal THESE PLANS AND ALL PROPOSED WORK -a ARE SUBJECT TO ANY CORRECTIONS ��� STATE OF •• i�r t REQUIRED BY FIELD INSPECTORS THAT y ,r . Fi OR10�' • +� MAY BE NECESSARY IN ORDER TO s,',° • • • • " �,�? COMP WITH ALL APPLICABLE CODES. Pi, ' ,ONAL � :••' .t..:::►►►�' Limitations: 1. Onderiayment to be compliance with current Florida Building Code (FBC)2017 6"' ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 6�' ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities wfJurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6°i ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. FL 17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details 16" Panel Profile 1 6".o.c. 3/4" 1 Deck: 15/32" or greater Plywood, or - Wood plank Snap Lock For METHOD 2: Apply 3/16" Bead Bostik 915TM Sealant Continuous Along Male Rib Vertical Flange \\\ i.\ `�\ �` - Fastener #10 x 1" Min. per Table "A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) 1" FL 17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details YGN\. 15/32" or greater Plywood, or - Wood plank Pnatanar Isometric View FUI MUL' 1Uu c Apply 3116" Bead Bostik 915TM Sealant Continuous Along Male Rib Vertical Flange (Refer to Table "A")